936 resultados para Aerobic deterioration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective This study investigated how consumption of orange juice associated with aerobic training affected serum lipids and physical characteristics of overweight middle-aged womenMethods The experimental group consisted of 13 women who consumed 500 mL/d of orange juice and did 1 h aerobic training 3 times a week for 3 months The control group consisted of another 13 women who did the same aerobic training program but did not consume orange juiceResults At the end of the experiment the control group lost an average of 15% of fat mass (P < 0 05) and 25% of weight (P < 0 05) whereas the experimental group lost 11% of fat mass and 1 2% of weight (P < 0 05) Consumption of orange juice by the experimental group was associated with Increased dietary intake of vitamin C and folate by 126% and 61% respectively Serum LDL-C decreased 15% (P < 0 05) and HDL-C increased 18% (P < 0 05) in the experimental group but no significant change was observed in the control group Both groups improved the anaerobic threshold by 20% (P < 0 05) but blood lactate concentration decreased 27% in the experimental group compared to the 17% control group suggesting that experimental group has less muscle fatigue and better response to trainingConclusions The consumption of 500 mL/d of orange juice associated with aerobic training in overweight women decreased cardiovascular disease risk by reducing LDL-C levels and increasing HDL-C levels This association also decreased blood lactate concentration and increased anaerobic threshold showing some improvement in the physical performance (C) 2010 Elsevier B.V. All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The toothbrush is an effective instrument for oral diseases prevention. The flexibility and status of bristles, as well as the size of the handle are fundamental for an effective toothbrushing. Thus, the assessment of physical characteristics of toothbrushes is important. This study evaluated the deterioration and wear of bristles of toothbrushes used by preschool children. For the sample selection, five elementary schools were assorted from a city of the São Paulo State northwest region, one from each city area. All toothbrushes used by preschool children who aged between 5 and 6 years old and who attended the assorted schools were visually analysed by two calibrated examiners, according to the criteria proposed by Rawls HR, Mkwayi-Tulloch NJ, Casella R, Cosgrove R (J Dent Res 1989; 12: 1781): 0 - it is impossible to state if the toothbrush was used or not; 1 - the bristles seem to be separated within some tufts; 2 - most tufts are separated, many cover other tufts and present a large number of curved and inclined bristles; 3 - most tufts are covered by others and bristles are folded and tipped. In total, 333 toothbrushes were evaluated. The data obtained revealed that 57.96% of the toothbrushes presented adequate condition for utilization (scores 0 and 1), whereas 42.04% presented inadequate bristles for their function (scores 2 and 3). It was concluded that a great number of toothbrushes presented deterioration of the bristles. Thus, there is the need to guide and promote awareness among teachers, parents and children as well as the need to replace toothbrushes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed to assess the aerobic biodegradation of butanol/gasoline, blends (5; 10; 15 and 20% v/v), being the latter compared to the ethanol/gasoline blend (20% v/v). Two experimental techniques were employed, namely the respirometric method and the redox indicator DCPIP test. in the former, experiments simulating the contamination of natural environments (addition of 50 mL of fuel kg(-1) of soil from a non-contaminated site and 20 mL of fuel L(-1) of water from a river) were carried out in biometer flasks (250 mL), used to measure the microbial CO(2) production. The DCPIP test assessed the capability of four inocula to biodegrade the blends of 20%. The addition of butanol at different concentrations enhanced the biodegradation of gasoline in soil. However, no practical gains were observed for concentrations of butanol above 10%. Ethanol showed to have a much faster biodegradation rate than butanol, particularly in water, and the following order of biodegradability was found: ethanol > butanol > gasoline. The addition of the alcohols to the gasoline resulted in positive synergic effects on the biodegradation of the fuels in soil and water matrices. Furthermore, results suggest that, in soil, butanol better enhanced the biodegradation of gasoline than ethanol. (C) 2009 Elsevier Ltd. All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maximal lactate steady state (MLSS) is the highest blood lactate concentration that can be identified as maintaining a steady state during a prolonged submaximal constant workload. The objective of the present study was to analyze the influence of the aerobic capacity on the validity of anaerobic threshold (AT) to estimate the exercise intensity at MLSS (MLSS intensity) during cycling. Ten untrained males (UC) and 9 male endurance cyclists (EC) matched for age, weight and height performed one incremental maximal load test to determine AT and two to four 30-min constant submaximal load tests on a mechanically braked cycle ergometer to determine MLSS and MLSS intensity. AT was determined as the intensity corresponding to 3.5 mM blood lactate. MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. MLSS intensity (EC = 282.1 ± 23.8 W; UC = 180.2 ± 24.5 W) and AT (EC = 274.8 ± 24.9 W; UC = 187.2 ± 28.0 W) were significantly higher in trained group. However, there was no significant difference in MLSS between EC (5.0 ± 1.2 mM) and UC (4.9 ± 1.7 mM). The MLSS intensity and AT were not different and significantly correlated in both groups (EC: r = 0.77; UC: r = 0.81). We conclude that MLSS and the validity of AT to estimate MLSS intensity during cycling, analyzed in a cross-sectional design (trained x sedentary), do not depend on the aerobic capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)