904 resultados para AGEING PERSONS
Resumo:
BACKGROUND. Transsexual persons afford a very suitable model to study the effect of sex steroids on uric acid metabolism. DESIGN. This was a prospective study to evaluate the uric acid levels and fractional excretion of uric acid (FEUA) in a cohort of 69 healthy transsexual persons, 22 male-to-female transsexuals (MFTs) and 47 female-to-male transsexuals (FMTs).The subjects were studied at baseline and 1 and 2 yr after starting cross-sex hormone treatment. RESULTS. The baseline levels of uric acid were higher in the MFT group.Compared with baseline, uric acid levels had fallen significantly after 1 yr of hormone therapy in the MFT group and had risen significantly in the FMT group. The baseline FEUA was greater in the FMT group. After 2 yr of cross-sex hormone therapy, the FEUA had increased in MFTs (P = 0.001) and fallen in FMTs (P = 0.004).In MFTs, the levels of uric acid at 2 yr were lower in those who had received higher doses of estrogens (P = 0.03),and the FEUA was higher (P = 0.04).The FEUA at 2 yr was associated with both the estrogen dose (P = 0.02) and the serum levels of estradiol-17beta (P =0.03).In MFTs, a correlation was found after 2 yr of therapy between the homeostasis model assessment of insulin resistance and the serum uric acid (r = 0.59; P = 0.01). CONCLUSIONS. Serum levels of uric acid and the FEUA are altered in transsexuals as a result of cross-sex hormone therapy.The results concerning the MFT group support the hypothesis that the lower levels of uric acid in women are due to estrogen-induced increases in FEUA.
Resumo:
OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.
Resumo:
BACKGROUND In the actual context of population ageing and extension of working age, programs for health promotion at the workplace are a key and necessary tool to promote an active and healthy ageing. This work presents the methodological process followed to elaborate a checklist tool, within the framework of the European project Progress, that contributes to orientate planning, implementation and evaluation of good practices in this field, to be applicable to a variety of programs, countries and workplaces. METHODS A Delphi technique has been applied in three rounds in which experts in the area from five European countries participated. A questionnaire created from a list of criteria and indicators was adapted throughout the rounds, with the use of webmail, to the evaluation of interventions in the field of interest. Through processes of assessment and consensus, criteria and indicators most relevant were prioritized. RESULTS From the nine starting criteria and after the implementation of the technique, four key criteria were prioritized: relevance: 62, adequacy to objective: 57, innovation: 50 and guarantee of quality: 41. Using this group of criteria and indicators, a checklist was designed containing the key information that should be collected for planning, implementation and evaluation of good practices in interventions in this field. CONCLUSIONS The checklist tool helps to systematize the global methodology for the implementation of interventions which could be very useful for persons responsible of programmes to promote active and healthy ageing in the workplace.
Resumo:
PURPOSE: Self-administered questionnaires continue to be the most widely used type of physical activity assessment in epidemiological studies. However, test-retest reliability and validity of physical activity questionnaires have to be determined. In this study, three short physical activity questionnaires already used in Switzerland and the International Physical Activity Questionnaire (IPAQ) were validated. METHODS: Test-retest reliability was assessed by repeated administration of all questionnaires within 3 wk in 178 volunteers (77 women, 46.1+/-14.8 yr; 101 men 46.8+/-13.2 yr). Validity of categorical and continuous data was studied in a subsample of 35 persons in relation to 7-d accelerometer readings, percent body fat, and cardiorespiratory fitness. RESULTS: Reliability was fair to good with a Spearman correlation coefficient range of 0.43-0.68 for measures of continuous data and moderate to fair with Kappa values between 0.32 and 0.46 for dichotomous measures active/inactive. Total physical activity reported in the IPAQ and the Office in Motion Questionnaire (OIMQ) correlated with accelerometry readings (r=0.39 and 0.44, respectively). In contrast, correlations of self-reported physical data with percent body fat and cardiorespiratory fitness were low (r=-0.26-0.29). Participants categorized as active by the Swiss HEPA Survey 1999 instrument (HEPA99) accumulated significantly more days of the recommended physical activities than their inactive counterparts (4.4 and 2.7 d.wk, respectively, P<0.05). However, compared with accelerometer data, vigorous physical activities were overreported in investigated questionnaires. CONCLUSION: Collecting valid data on physical activity remains a challenging issue for questionnaire surveys. The IPAQ and the three other questionnaires are characterized to inform decisions about their appropriate use.
Resumo:
Agency Performance Plan
Resumo:
Annual Report for Departmemnt of Human Rights
Resumo:
Missing persons summary
Resumo:
Missing persons summary