936 resultados para 1088


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Boletín semanal para profesionales sanitarios de la Secretaría General de Salud Pública y Participación Social de la Consejería de Salud

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epidemiological surveillance systems are essential and require efficient collaborations between family doctors and public health services. Such a system has to take into account the increase in the number of health problems to be studied. Information gathered at an individual level should imply decisions at a population level which in turn should impact on the individual patient. Epidemiological surveillance requires a well organized, representative and constantly revised system led by motivated, adequately trained doctors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSION: Chronic subjective dizziness (CSD) is frequent and affects twice as many women as men. Anxiety is a strong predisposing factor. The pathophysiologic concept of this disorder assumes that balance function and emotion share common neurologic pathways, which might explain that the balance disorder can provoke fear and vice versa, giving rise to a problem in perception of space and motion. In anxious patients this can turn into a space and motion phobia, with avoidance behaviour. OBJECTIVE: CSD is a diagnosis based on the hypothesis of an interaction between the vestibular system and the psychiatric sphere. Patients complain of chronic imbalance, worsened by visual motion stimulation, and frequently suffer from anxiety. Vestibular examination reveals no anomalies. We evaluated the incidence and characteristics of CSD in patients referred to our neuro-otology centre (tertiary hospital outpatient clinic). SUBJECTS AND METHODS: This was a retrospective study of 1552 consecutive patients presenting with vertigo. CSD was diagnosed in 164 patients (female:male=111:53). RESULTS: CSD represents 10.6% of the dizzy patients in our clinic. Psychiatric disorder, mainly anxiety, was found in 79.3% of the cases. Other frequently associated factors were fear of heights and former vestibular lesion (healed). In all, 79.0% of the patients with CSD had poor balance performance on dynamic posturography testing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inspired by experiments that use single-particle tracking to measure the regions of confinement of selected chromosomal regions within cell nuclei, we have developed an analytical approach that takes into account various possible positions and shapes of the confinement regions. We show, in particular, that confinement of a particle into a subregion that is entirely enclosed within a spherical volume can lead to a higher limit of the mean radial square displacement value than the one associated with a particle that can explore the entire spherical volume. Finally, we apply the theory to analyse the motion of extrachromosomal chromatin rings within nuclei of living yeast.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Probably the most natural energy functional to be considered for knotted strings is that given by electrostatic repulsion. In the absence of counter-charges, a charged, knotted string evolving along the energy gradient of electrostatic repulsion would progressively tighten its knotted domain into a point on a perfectly circular string. However, in the presence of charge screening self-repelling knotted strings can be stabilized. It is known that energy functionals in which repulsive forces between repelling charges grow inversely proportionally to the third or higher power of their relative distance stabilize self-repelling knots. Especially interesting is the case of the third power since the repulsive energy becomes scale invariant and does not change upon Mobius transformations (reflections in spheres) of knotted trajectories. We observe here that knots minimizing their repulsive Mobius energy show quantization of the energy and writhe (measure of chirality) within several tested families of knots.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we study the average inter-crossing number between two random walks and two random polygons in the three-dimensional space. The random walks and polygons in this paper are the so-called equilateral random walks and polygons in which each segment of the walk or polygon is of unit length. We show that the mean average inter-crossing number ICN between two equilateral random walks of the same length n is approximately linear in terms of n and we were able to determine the prefactor of the linear term, which is a = (3 In 2)/(8) approximate to 0.2599. In the case of two random polygons of length n, the mean average inter-crossing number ICN is also linear, but the prefactor of the linear term is different from that of the random walks. These approximations apply when the starting points of the random walks and polygons are of a distance p apart and p is small compared to n. We propose a fitting model that would capture the theoretical asymptotic behaviour of the mean average ICN for large values of p. Our simulation result shows that the model in fact works very well for the entire range of p. We also study the mean ICN between two equilateral random walks and polygons of different lengths. An interesting result is that even if one random walk (polygon) has a fixed length, the mean average ICN between the two random walks (polygons) would still approach infinity if the length of the other random walk (polygon) approached infinity. The data provided by our simulations match our theoretical predictions very well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The publication of a draft of the human genome and of large collections of transcribed sequences has made it possible to study the complex relationship between the transcriptome and the genome. In the work presented here, we have focused on mapping mRNA 3' ends onto the genome by use of the raw data generated by the expressed sequence tag (EST) sequencing projects. We find that at least half of the human genes encode multiple transcripts whose polyadenylation is driven by multiple signals. The corresponding transcript 3' ends are spread over distances in the kilobase range. This finding has profound implications for our understanding of gene expression regulation and of the diversity of human transcripts, for the design of cDNA microarray probes, and for the interpretation of gene expression profiling experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

City Audit Report

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using a numerical approach, we explore wave-induced fluid flow effects in partially saturated porous rocks in which the gas-water saturation patterns are governed by mesoscopic heterogeneities associated with the dry frame properties. The link between the dry frame properties and the gas saturation is defined by the assumption of capillary pressure equilibrium, which in the presence of heterogeneity implies that neighbouring regions can exhibit different levels of saturation. To determine the equivalent attenuation and phase velocity of the synthetic rock samples considered in this study, we apply a numerical upscaling procedure, which permits to take into account mesoscopic heterogeneities associated with the dry frame properties as well as spatially continuous variations of the pore fluid properties. The multiscale nature of the fluid saturation is taken into account by locally computing the physical properties of an effective fluid, which are then used for the larger-scale simulations. We consider two sets of numerical experiments to analyse such effects in heterogeneous partially saturated porous media, where the saturation field is determined by variations in porosity and clay content, respectively. In both cases we also evaluate the seismic responses of corresponding binary, patchy-type saturation patterns. Our results indicate that significant attenuation and modest velocity dispersion effects take place in this kind of media for both binary patchy-type and spatially continuous gas saturation patterns and in particular in the presence of relatively small amounts of gas. The numerical experiments also show that the nature of the gas distribution patterns is a critical parameter controlling the seismic responses of these environments, since attenuation and velocity dispersion effects are much more significant and occur over a broader saturation range for binary patchy-type gas-water distributions. This analysis therefore suggests that the physical mechanisms governing partial saturation should be accounted for when analysing seismic data in a poroelastic framework. In this context, heterogeneities associated with the dry frame properties, which do not play important roles in wave-induced fluid flow processes per se, should be taken into account since they may determine the kind of gas distribution pattern taking place in the porous rock.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les spécialistes en santé au travail ont très tôt insisté pour établir des lois et des mesures de protection contre la fumée passive pour les employés, comme l'article de J. Perrenoud ["Tabagisme passif : avancées et pièges dans l'évolution du droit suisse"] le montre. Dans la recherche également, les premières études sur les effets nocifs et gênants ont été réalisées par les spécialistes en santé au travail. Dans les années 70 et 80, c'est plus particulièrement A. Weber et ses collègues de l'IHA ETH Zurich qui ont montré que l'irritation des yeux, le clignement des paupières et la sensation de gêne augmentent en fonction de la concentration de la fumée passive et de la durée de l'exposition. Ces travaux ont été pris en compte dans le fameux rapport américain du Surgeon General sur la nocivité de la fumée passive : le point de départ de la lutte contre la fumée passive aux Etats-Unis. Au niveau de l'exposition, les hygiénistes de l'Institut universitaire romand de santé au travail (IST) ont développé des techniques de mesure et de prélèvement. [Auteure (extrait)]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A traditional photonic-force microscope (PFM) results in huge sets of data, which requires tedious numerical analysis. In this paper, we propose instead an analog signal processor to attain real-time capabilities while retaining the richness of the traditional PFM data. Our system is devoted to intracellular measurements and is fully interactive through the use of a haptic joystick. Using our specialized analog hardware along with a dedicated algorithm, we can extract the full 3D stiffness matrix of the optical trap in real time, including the off-diagonal cross-terms. Our system is also capable of simultaneously recording data for subsequent offline analysis. This allows us to check that a good correlation exists between the classical analysis of stiffness and our real-time measurements. We monitor the PFM beads using an optical microscope. The force-feedback mechanism of the haptic joystick helps us in interactively guiding the bead inside living cells and collecting information from its (possibly anisotropic) environment. The instantaneous stiffness measurements are also displayed in real time on a graphical user interface. The whole system has been built and is operational; here we present early results that confirm the consistency of the real-time measurements with offline computations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.