949 resultados para “One-to-One”
Resumo:
PURPOSE: To compare objective fellow and expert efficiency indices for an interventional radiology renal artery stenosis skill set with the use of a high-fidelity simulator. MATERIALS AND METHODS: The Mentice VIST simulator was used for three different renal artery stenosis simulations of varying difficulty, which were used to grade performance. Fellows' indices at three intervals throughout 1 year were compared to expert baseline performance. Seventy-four simulated procedures were performed, 63 of which were captured as audiovisual recordings. Three levels of fellow experience were analyzed: 1, 6, and 12 months of dedicated interventional radiology fellowship. The recordings were compiled on a computer workstation and analyzed. Distinct measurable events in the procedures were identified with task analysis, and data regarding efficiency were extracted. Total scores were calculated as the product of procedure time, fluoroscopy time, tools, and contrast agent volume. The lowest scores, which reflected efficient use of tools, radiation, and time, were considered to indicate proficiency. Subjective analysis of participants' procedural errors was not included in this analysis. RESULTS: Fellows' mean scores diminished from 1 month to 12 months (42,960 at 1 month, 18,726 at 6 months, and 9,636 at 12 months). The experts' mean score was 4,660. In addition, the range of variance in score diminished with increasing experience (from a range of 5,940-120,156 at 1 month to 2,436-85,272 at 6 months and 2,160-32,400 at 12 months). Expert scores ranged from 1,450 to 10,800. CONCLUSIONS: Objective efficiency indices for simulated procedures can demonstrate scores directly comparable to the level of clinical experience.
Resumo:
From Bush’s September 20, 2001 “War on Terror” speech to Congress to President-Elect Barack Obama’s acceptance speech on November 4, 2008, the U.S. Army produced visual recruitment material that addressed the concerns of falling enlistment numbers—due to the prolonged and difficult war in Iraq—with quickly-evolving and compelling rhetorical appeals: from the introduction of an “Army of One” (2001) to “Army Strong” (2006); from messages focused on education and individual identity to high-energy adventure and simulated combat scenarios, distributed through everything from printed posters and music videos to first-person tactical-shooter video games. These highly polished, professional visual appeals introduced to the American public during a time of an unpopular war fought by volunteers provide rich subject matter for research and analysis. This dissertation takes a multidisciplinary approach to the visual media utilized as part of the Army’s recruitment efforts during the War on Terror, focusing on American myths—as defined by Barthes—and how these myths are both revealed and reinforced through design across media platforms. Placing each selection in its historical context, this dissertation analyzes how printed materials changed as the War on Terror continued. It examines the television ad that introduced “Army Strong” to the American public, considering how the combination of moving image, text, and music structure the message and the way we receive it. This dissertation also analyzes the video game America’s Army, focusing on how the interaction of the human player and the computer-generated player combine to enhance the persuasive qualities of the recruitment message. Each chapter discusses how the design of the particular medium facilitates engagement/interactivity of the viewer. The conclusion considers what recruitment material produced during this time period suggests about the persuasive strategies of different media and how they create distinct relationships with their spectators. It also addresses how theoretical frameworks and critical concepts used by a variety of disciplines can be combined to analyze recruitment media utilizing a Selber inspired three literacy framework (functional, critical, rhetorical) and how this framework can contribute to the multimodal classroom by allowing instructors and students to do a comparative analysis of multiple forms of visual media with similar content.
Resumo:
We report on our experiences with the Spy project, including implementation details and benchmark results. Spy is a re-implementation of the Squeak (i.e., Smalltalk-80) VM using the PyPy toolchain. The PyPy project allows code written in RPython, a subset of Python, to be translated to a multitude of different backends and architectures. During the translation, many aspects of the implementation can be independently tuned, such as the garbage collection algorithm or threading implementation. In this way, a whole host of interpreters can be derived from one abstract interpreter definition. Spy aims to bring these benefits to Squeak, allowing for greater portability and, eventually, improved performance. The current Spy codebase is able to run a small set of benchmarks that demonstrate performance superior to many similar Smalltalk VMs, but which still run slower than in Squeak itself. Spy was built from scratch over the course of a week during a joint Squeak-PyPy Sprint in Bern last autumn.
Resumo:
Oxford University Press 2011, ISBN 978-0-19-958037-8
Resumo:
OBJECTIVE to compare the vascular healing process between the sirolimus-eluting NEVO and the everolimus-eluting Xience stent by optical coherence tomography (OCT) at 1-year follow-up. BACKGROUND Presence of durable polymer on a drug-eluting metallic stent may be the basis of an inflammatory reaction with abnormal healing response. The NEVO stent, having a bioresorbable polymer eluted by reservoir technology, may overcome this problem. METHODS All consecutive patients, who received NEVO or Xience stent implantation between September 2010 and October 2010 in our institution, were included. Vascular healing was assessed at 1-year as percentage of uncovered struts, neointimal thickness (NIT), in-stent/stent area obstruction and pattern of neointima. RESULTS A total 47 patients (2:1 randomization, n = 32 NEVO, n = 15 Xience) were included. Eighteen patients underwent angiographic follow-up (eight patients with nine lesions for NEVO vs. 10 patients with 11 lesions for Xience). The angiographic late loss was numerically higher but not statistically different in NEVO compared with Xience treated lesions (0.38 ± 0.47 mm vs. 0.18 ± 0.27 mm; P = 0.171). OCT analysis of 4,912 struts demonstrated similar rates of uncovered struts (0.5 vs. 0.7%, P = 0.462), higher mean NIT (177.76 ± 87.76 µm vs. 132.22 ± 30.91 µm; P = 0.170) and in stent/stent area obstruction (23.02 ± 14.74% vs. 14.17 ± 5.94%, P = 0.120) in the NEVO as compared with Xience. CONCLUSION The NEVO stent with a reservoir technology seems to exhibit more neointimal proliferation as compared to Xience stent. The findings of our study, which currently represent the unique data existing on this reservoir technology, would need to be confirmed in a large population.
Resumo:
OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.