688 resultados para vena cava


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and Objectives - A controversy exists in the literature regarding the effects of the acute administration of magnesium on the cardiovascular system of animals and humans. The purpose of this study was to evaluate the effects of hypermagnesemia on the cardiovascular hemodynamics of dogs. Methods - Sixteen mongrel dogs were anesthetized with pentobarbitone 30 mg.kg-1 and submitted to volume expansion with Ringer's solution (0.4 ml.kg-1.min-1 and mechanical ventilation with room air. In this model, the hemodynamic repercussions of the following drugs and doses were studied. pentobarbitone 5 mg.kg-1 Group 1, control - and the association of pentobarbitone and magnesium sulphate (MS), at the dose of 140 mg.kg-1 injected in 15 minutes, followed by an infusion of 80 mg.kg-1.h-1 - Group 2. The parameters studied were: heart rate, blood pressure, inferior vena cava pressure, cardiac index, systolic index and peripheral resistance index, evaluated at 5 different moments: 15(M1), 30(M2), 60(M3) and 75(M4) minutes after the first suppplementary dose of pentobarbitone and 15 minutes (M5) after the second supplementary dose. In Group 2, the moments M3, M4, M5 corresponded to 15, 30 and 60 minutes after the priming dose of magnesium sulphate. Results - Group 1 animals exhibited tachycardia since the beginning of the experiment. There was a decrease in the cardiac index, in the systolic index and an increase in the inferior vena cava pressure. Group 2 animals also exhibited tachycardia, but heart rate decreased after MS infusion. The blood pressure and the peripheral resistance index decreased. The systolic index increased and the cardiac index decreased only at the end of the experiment. Conclusions: The antiadrenergic effects of MS could have been responsible for the decrease in heart rate. The vasodilating effects of the magnesium induced the decrease in the peripheral resistance index. The systolic index increased, showing that myocardial depression did not occur.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors admit that the conjunctive-muscular constitution of the walls of the superior venae cavae throughout the length of the intrapericardium segment and the debouchement in the right atrium, associated with the presence of a myocardium sheath can be made up of a functional device of sphincter form able to act on the control of the blood flow to the interior of the arterial chamber as well as stopping blood flow during the arterial systole. The fixation of the venous wall to the deep chamber of the serous pericardium, contributes to growth in resistance during the elevation of venous pressure, making possible the preservation of integrity of the superior venae cavae. The expansion of fasciculi of nodal fibers in the right wall of the superior venae cavae permits that the unlocked impulse in the S-A node also reaches the vascular wall contributing to the shortening and diminution in caliber of the vein.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and Objectives - Allopurinol is a drug which inhibits the formation of noxious renal free radicals. The aim of this study was to evaluate the protecting renal effects of allopurinol in ischemic kidneys of dogs. Methods - Sixteen dogs were anesthetized with sodium pentobarbital and submitted to extracellular volume expansion (1.4 ml.kg-1.min-1), to mechanic ventilation with air, to right nephrectomy and to left renal artery clamping. Changes which might occur in renal morphology and function after 30 min of total ischemia and posterior reperfusion were studied in Group 1 (G1), in addition to the action of allopurinol (50 mg.kg-1) on those kidneys, when administered 24 h before the experiment and 1 h before the ischemic procedure in Group 2 (G2). The following parameters: heart rate, inferior vena cava pressure, mean blood pressure, PAH clearance (PAH(c)), renal blood flow (RBF), renal vascular resistance (RVR), creatinine clearance (Cr(c)), filtration fraction, urine output, plasma and urine osmolality, osmolar clearance, free water, sodium and potassium clearance, urine and fractional sodium and potassium excretion, hematocrit, rectal temperature, and left kidney histology were evaluated in four moments: M1 control, and M2, M3, M4 obtained immediately, 15 and 30 min after unclamping of the left renal artery. In G2, M1, M2, M3 and M4 were obtained 45, 90, 105, and 120 min after the second allopurinol dose. Results - Both groups showed the highest values for PAH(c), RBF, and Cr(c), and the lowest values for RVR in M1. Animals were tachycardiac since the beginning of the experiment both in G1 and in G2. The other parameters were not changed. Left kidney histological evaluation showed alterations compatible with acute tubular necrosis in both experimental groups. Conclusions - Alterations found in renal hemodynamics were compatible with the release of vasoconstrictor substances due to renal ischemia. Allopurinol was not effective in preventing renal alterations caused by ischemia and reperfusion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Cardiovascular diseases remain leaders as the major causes of mortality in Western society. Restoration of the circulation through construction of bypass surgical treatment is regarded as the gold standard treatment of peripheral vascular diseases, and grafts are necessary for this purpose. The great saphenous vein is often not available and synthetic grafts have their limitations. Therefore, new techniques to produce alternative grafts have been developed and, in this sense, tissue engineering is a promising alternative to provide biocompatible grafts. This study objective was to reconstruct the endothelium layer of decellularized vein scaffolds, using mesenchymal stem cells (MSCs) and growth factors obtained from platelets. Methods: Fifteen nonpregnant female adult rabbits were used for all experiments. Adipose tissue and vena cava were obtained and subjected to MSCs isolation and tissue decellularization, respectively. MSCs were subjected to differentiation using endothelial inductor growth factor (EIGF) obtained from human platelet lysates. Immunofluorescence, histological and immunohistochemical analyses were employed for the final characterization of the obtained blood vessel substitute. Results: The scaffolds were successfully decellularized with sodium dodecyl sulfate. MSCs actively adhered at the scaffolds, and through stimulation with EIGF were differentiated into functional endothelial cells, secreting significantly higher quantities of von Willebrand factor (0.85 μg/mL; P < .05) than cells cultivated under the same conditions, without EIGF (0.085 μg/mL). Cells with evident morphologic characteristics of endothelium were seen at the lumen of the scaffolds. These cells also stained positive for fascin protein, which is highly expressed by differentiated endothelial cells. Conclusions: Taken together, the use of decellularized bioscaffold and subcutaneous MSCs seems to be a potential approach to obtain bioengineered blood vessels, in the presence of EIGF supplementation. © 2013 Society for Vascular Surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The knowledge of the mechanisms underlying circulating volume control may be achieved by stretching a balloon placed at the junction of the superior vena cava-right atrial junction (SVC-RAJ). We investigated whether the inflation of a balloon at the SVC-RAJ inhibits the intake of 0.3M NaCl induced by GABAA receptor activation in the lateral parabrachial nucleus (LPBN) in euhydrated and satiated rats. Male Wistar rats (280-300g) with bilateral stainless steel LPBN cannulae and balloons implanted at the SVC-RAJ were used. Bilateral injections of the GABAA receptor agonist muscimol (0.5ηmol/0.2l) in the LPBN with deflated balloons increased intake of 0.3M NaCl (30.1±3.9 vs. saline: 2.2±0.7)ml/210min, n=8) and water (17.7±1.9 vs. saline: 2.9±0.5ml/210min). Conversely, 0.3M NaCl (27.8±2.1ml/210min) and water (22.8±2.3ml/210min) intake were not affected in rats with inflated balloons at the SVC-RAJ. The results show that sodium and water intake induced by muscimol injected into the LPBN was not affected by balloon inflation at the SVC-RAJ. We suggest that the blockade of LPBN neuronal activity with muscimol injections impairs inhibitory mechanisms activated by signals from cardiopulmonary volume receptors determined by balloon inflation. © 2013 The Authors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Farmacologia) - IBB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Anestesiologia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Training in rats adapts the portal vein to respond vigorously to sympathetic stimuli even when the animal is re-exposed to exercise. Moreover, changes in the exercise-induced effects of angiotensin II, a potent venoconstrictor agonist, in venous beds remain to be investigated. Therefore, the present study aimed to assess the effects of angiotensin II in the portal vein and vena cava from sedentary and trained rats at rest or submitted to an exercise session immediately before organ bath experiments. We found that training or exposure of sedentary animals to a single bout of running exercise does not significantly change the responses of the rat portal vein to angiotensin II. However, the exposure of trained animals to a single bout of running exercise enhanced the response of the rat portal vein to angiotensin II. This enhancement appeared to be territory-specific because it was not observed in the vena cava. Moreover, it was not observed inendothelium-disrupted preparations and in preparations treated with Nω-nitro-l-arginine methyl esterhydrochloride, indomethacin, BQ-123 or BQ-788. These data indicate that training causes adaptations in the rat portal vein that respond vigorously to angiotensin II even upon re-exposure to exercise. This increased response to angiotensin II requires an enhancement of the vasocontractile influence of endothelin beyond the influence of nitric oxide and vasodilator prostanoids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rats bearing lesions in the septal area followed by lesions in the subfornical organ were submitted to various thirst-eliciting procedures. The rats with hyperdipsia induced by lesions of the septal area drank more water than either during the control period or after lesion of the subfornical organ under the same thirst-eliciting or angiotensin-liberating stimuli (polyethyleneglycol, isoproterenol, water deprivation and ligation of the inferior vena cava). The overdrinking elicited by lesions in the septal area was blocked after lesion of the subfornical organ. Neither hypovolemia, nor hypotension or water deprivation could elicit increased water intake in animals whose subfornical organ had been destroyed. Animals with lesions in the subfornical organ showed decreased water intake after cellular dehydration. The results obtained suggest that the subfornical organ acts as a more important structure than the septal area in the regulation of water intake elicited by angiotensin, with two opposite effects: a direct one facilitating water intake, and an indirect one inhibiting the septal area. The septal area has an inhibitory effect on the subfornical organ and on water intake. © 1980.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To present a model for research and training in multivisceral transplantation in pigs. Methods: Eight Large White pigs (four donors and four recipients) were operated. The multivisceral transplant with stomach, duodenum, pancreas, liver and intestine was performed similarly to transplantation in humans with a few differences, described below. Anastomoses were performed as follows: end-to-end from the supra-hepatic vena cava of the graft to the recipient juxta diaphragmatic vena cava; end-to-end from the infra-hepatic vena cava of the graft to the inferior (suprarenal) vena cava of the recipient; and endto-side patch of the aorta of the graft to the infrarenal aorta of the recipient plus digestive reconstruction. Results: The performance of the multivisceral transplantion was possible in all four animals. Reperfusions of the multivisceral graft led to a severe ischemia-reperfusion syndrome, despite flushing of the graft. The animals presented with hypotension and the need for high doses of vasoactive drugs, and all of them were sacrificed after discontinuing these drugs. Conclusion: Some alternatives to minimize the ischemia-reperfusion syndrome, such as the use of another vasoactive drug, use of a third pig merely for blood transfusion, presence of an anesthesia team in the operating room, and reduction of the graft, will be the next steps to enable experimental studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The diameters and areas of portal vein, caudal vena cava and abdominal aorta are useful measurements in dogs. These values can be easily measured by ultrasonographic exam, and variations of normality can be an important indicator of hepatic or extra-hepatic alterations. This study aimed to measure the diameter and areas of portal vein, caudal vena cava and abdominal aorta inhealthy dogs, with normal corporal score, divided in groups according to the body weight, and assess whether the data are influenced by animal weight. Thirty dogs were examined and divided into three groups (Group A: ≤ 10 kg Group B: from 10.1 to 20.0 kg; Group C: ≥ 20.1 kg). To measure thediameters and areas of portal vein, caudal vena cava and abdominal aorta, the animal was kept in left lateral decubitus position and the transducer was placed on the right lateral abdominal wall, at approximately the 10th or 11th intercostal space, in the porta hepatis region. The diameters and areas of the portal vein, caudal vena cava and abdominal aorta were significantly lower for dogs in Group A with respect to other groups and the dogs from Groups B and C had similar results with each other. The diameters and areas of the portal vein, caudal vena cava and abdominal aorta may vary with the animal size, and reference values must be specific for small, medium and large dogs. Key words: abdominal vessels; area; diameter; measurement; ultrasonographic exam