983 resultados para vídeo-EEG


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several clinical studies have reported that EEG synchrony is affected by Alzheimer’s disease (AD). In this paper a frequency band analysis of AD EEG signals is presented, with the aim of improving the diagnosis of AD using EEG signals. In this paper, multiple synchrony measures are assessed through statistical tests (Mann–Whitney U test), including correlation, phase synchrony and Granger causality measures. Moreover, linear discriminant analysis (LDA) is conducted with those synchrony measures as features. For the data set at hand, the frequency range (5-6Hz) yields the best accuracy for diagnosing AD, which lies within the classical theta band (4-8Hz). The corresponding classification error is 4.88% for directed transfer function (DTF) Granger causality measure. Interestingly, results show that EEG of AD patients is more synchronous than in healthy subjects within the optimized range 5-6Hz, which is in sharp contrast with the loss of synchrony in AD EEG reported in many earlier studies. This new finding may provide new insights about the neurophysiology of AD. Additional testing on larger AD datasets is required to verify the effectiveness of the proposed approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroencephalographic (EEG) recordings are, most of the times, corrupted by spurious artifacts, which should be rejected or cleaned by the practitioner. As human scalp EEG screening is error-prone, automatic artifact detection is an issue of capital importance, to ensure objective and reliable results. In this paper we propose a new approach for discrimination of muscular activity in the human scalp quantitative EEG (QEEG), based on the time-frequency shape analysis. The impact of the muscular activity on the EEG can be evaluated from this methodology. We present an application of this scoring as a preprocessing step for EEG signal analysis, in order to evaluate the amount of muscular activity for two set of EEG recordings for dementia patients with early stage of Alzheimer’s disease and control age-matched subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Does Independent Component Analysis (ICA) denature EEG signals? We applied ICA to two groups of subjects (mild Alzheimer patients and control subjects). The aim of this study was to examine whether or not the ICA method can reduce both group di®erences and within-subject variability. We found that ICA diminished Leave-One- Out root mean square error (RMSE) of validation (from 0.32 to 0.28), indicative of the reduction of group di®erence. More interestingly, ICA reduced the inter-subject variability within each group (¾ = 2:54 in the ± range before ICA, ¾ = 1:56 after, Bartlett p = 0.046 after Bonfer- roni correction). Additionally, we present a method to limit the impact of human error (' 13:8%, with 75.6% inter-cleaner agreement) during ICA cleaning, and reduce human bias. These ¯ndings suggests the novel usefulness of ICA in clinical EEG in Alzheimer's disease for reduction of subject variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop systems in order to detect Alzheimer’s disease we want to use EEG signals. Available database is raw, so the first step must be to clean signals properly. We propose a new way of ICA cleaning on a database recorded from patients with Alzheimer's disease (mildAD, early stage). Two researchers visually inspected all the signals (EEG channels), and each recording's least corrupted (artefact-clean) continuous 20 sec interval were chosen for the analysis. Each trial was then decomposed using ICA. Sources were ordered using a kurtosis measure, and the researchers cleared up to seven sources per trial corresponding to artefacts (eye movements, EMG corruption, EKG, etc), using three criteria: (i) Isolated source on the scalp (only a few electrodes contribute to the source), (ii) Abnormal wave shape (drifts, eye blinks, sharp waves, etc.), (iii) Source of abnormally high amplitude ( �100 �V). We then evaluated the outcome of this cleaning by means of the classification of patients using multilayer perceptron neural networks. Results are very satisfactory and performance is increased from 50.9% to 73.1% correctly classified data using ICA cleaning procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Electroencephalogram (EEG) background reactivity is a potentially interesting outcome predictor in comatose patients, especially after cardiac arrest, but recent studies report only fair interrater reliability. Furthermore, there are no definite guidelines for its testing. We therefore investigated the EEG effect of standardized noxious stimuli in comatose patients not reactive to auditory stimuli. METHODS: In this prospective study we applied a protocol using three different painful stimuli (bilateral nipple pinching, pinprick at the nose base, finger-nail compression on each side), grouped in three distinct clusters with an alternated sequence, during EEG recordings in comatose patients. We only analyzed recordings showing any reactivity to pain. Fisher and χ2 tests were used as needed to assess contingency tables. RESULTS: Of 42 studies, 12 did not show any background reactivity, 2 presented SIRPIDs, and 2 had massive artefacts; we thus analyzed 26 EEGs recorded in 17 patients (4 women, 24%). Nipple pinching more frequently induced a change in EEG background activity (p<0.001), with a sensitivity of 97.4% for reactivity. Neither the order of the stimuli in the cluster (p=0.723), nor the cluster order (p=0.901) influenced the results. CONCLUSION: In this pilot study, bilateral, synchronous nipple pinching seems to be the most efficient method to test nociceptive EEG reactivity in comatose patients. This approach may enhance interrater reliability, but deserves confirmation in larger cohorts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: EEG is widely used to predict outcome in comatose cardiac arrest patients, but its value has been limited by lack of a uniform classification. We used the EEG terminology proposed by the American Clinical Neurophysiology Society (ACNS) to assess interrater variability in a cohort of cardiac arrest patients included in the Target Temperature Management trial. The main objective was to evaluate if malignant EEG-patterns could reliably be identified. METHODS: Full-length EEGs from 103 comatose cardiac arrest patients were interpreted by four EEG-specialists with different nationalities who were blinded for patient outcome. Percent agreement and kappa (κ) for the categories in the ACNS EEG terminology and for prespecified malignant EEG-patterns were calculated. RESULTS: There was substantial interrater agreement (κ 0.71) for highly malignant patterns and moderate agreement (κ 0.42) for malignant patterns. Substantial agreement was found for malignant periodic or rhythmic patterns (κ 0.72) while agreement for identifying an unreactive EEG was fair (κ 0.26). CONCLUSIONS: The ACNS EEG terminology can be used to identify highly malignant EEG-patterns in post cardiac arrest patients in an international context with high reliability. SIGNIFICANCE: The establishment of strict criteria with high transferability between interpreters will increase the usefulness of routine EEG to assess neurological prognosis after cardiac arrest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postanoxic coma after cardiac arrest is one of the most serious acute cerebral conditions and a frequent cause of admission to critical care units. Given substantial improvement of outcome over the recent years, a reliable and timely assessment of clinical evolution and prognosis is essential in this context, but may be challenging. In addition to the classic neurologic examination, EEG is increasingly emerging as an important tool to assess cerebral functions noninvasively. Although targeted temperature management and related sedation may delay clinical assessment, EEG provides accurate prognostic information in the early phase of coma. Here, the most frequently encountered EEG patterns in postanoxic coma are summarized and their relations with outcome prediction are discussed. This article also addresses the influence of targeted temperature management on brain signals and the implication of the evolution of EEG patterns over time. Finally, the article ends with a view of the future prospects for EEG in postanoxic management and prognostication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurophysiology is an essential tool for clinicians dealing with patients in the intensive care unit. Because of consciousness disorders, clinical examination is frequently limited. In this setting, neurophysiological examination provides valuable information about seizure detection, treatment guidance, and neurological outcome. However, to acquire reliable signals, some technical precautions need to be known. EEG is prone to artifacts, and the intensive care unit environment is rich in artifact sources (electrical devices including mechanical ventilation, dialysis, and sedative medications, and frequent noise, etc.). This review will discuss and summarize the current technical guidelines for EEG acquisition and also some practical pitfalls specific for the intensive care unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify the clinical determinants of occurrence of postictal generalized EEG suppression (PGES) after generalized convulsive seizures (GCS). METHODS: We reviewed the video-EEG recordings of 417 patients included in the REPO2MSE study, a multicenter prospective cohort study of patients with drug-resistant focal epilepsy. According to ictal semiology, we classified GCS into 3 types: tonic-clonic GCS with bilateral and symmetric tonic arm extension (type 1), clonic GCS without tonic arm extension or flexion (type 2), and GCS with unilateral or asymmetric tonic arm extension or flexion (type 3). Association between PGES and person-specific or seizure-specific variables was analyzed after correction for individual effects and the varying number of seizures. RESULTS: A total of 99 GCS in 69 patients were included. Occurrence of PGES was independently associated with GCS type (p < 0.001) and lack of early administration of oxygen (p < 0.001). Odds ratio (OR) for GCS type 1 in comparison with GCS type 2 was 66.0 (95% confidence interval [CI 5.4-801.6]). In GCS type 1, risk of PGES was significantly increased when the seizure occurred during sleep (OR 5.0, 95% CI 1.2-20.9) and when oxygen was not administered early (OR 13.4, 95% CI 3.2-55.9). CONCLUSION: The risk of PGES dramatically varied as a function of GCS semiologic characteristics. Whatever the type of GCS, occurrence of PGES was prevented by early administration of oxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify reliable predictors of outcome in comatose patients after cardiac arrest using a single routine EEG and standardized interpretation according to the terminology proposed by the American Clinical Neurophysiology Society. METHODS: In this cohort study, 4 EEG specialists, blinded to outcome, evaluated prospectively recorded EEGs in the Target Temperature Management trial (TTM trial) that randomized patients to 33°C vs 36°C. Routine EEG was performed in patients still comatose after rewarming. EEGs were classified into highly malignant (suppression, suppression with periodic discharges, burst-suppression), malignant (periodic or rhythmic patterns, pathological or nonreactive background), and benign EEG (absence of malignant features). Poor outcome was defined as best Cerebral Performance Category score 3-5 until 180 days. RESULTS: Eight TTM sites randomized 202 patients. EEGs were recorded in 103 patients at a median 77 hours after cardiac arrest; 37% had a highly malignant EEG and all had a poor outcome (specificity 100%, sensitivity 50%). Any malignant EEG feature had a low specificity to predict poor prognosis (48%) but if 2 malignant EEG features were present specificity increased to 96% (p < 0.001). Specificity and sensitivity were not significantly affected by targeted temperature or sedation. A benign EEG was found in 1% of the patients with a poor outcome. CONCLUSIONS: Highly malignant EEG after rewarming reliably predicted poor outcome in half of patients without false predictions. An isolated finding of a single malignant feature did not predict poor outcome whereas a benign EEG was highly predictive of a good outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite recent advances, early diagnosis of Alzheimer’s disease (AD) from electroencephalography (EEG) remains a difficult task. In this paper, we offer an added measure through which such early diagnoses can potentially be improved. One feature that has been used for discriminative classification is changes in EEG synchrony. So far, only the decrease of synchrony in the higher frequencies has been deeply analyzed. In this paper, we investigate the increase of synchrony found in narrow frequency ranges within the θ band. This particular increase of synchrony is used with the well-known decrease of synchrony in the band to enhance detectable differences between AD patients and healthy subjects. We propose a new synchrony ratio that maximizes the differences between two populations. The ratio is tested using two different data sets, one of them containing mild cognitive impairment patients and healthy subjects, and another one, containing mild AD patients and healthy subjects. The results presented in this paper show that classification rate is improved, and the statistical difference between AD patients and healthy subjects is increased using the proposed ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mismatch negativity is an electrophysiological marker of auditory change detection in the event-related brain potential and has been proposed to reflect an automatic comparison process between an incoming stimulus and the representation of prior items in a sequence. There is evidence for two main functional subcomponents comprising the MMN, generated by temporal and frontal brain areas, respectively. Using data obtained in an MMN paradigm, we performed time-frequency analysis to reveal the changes in oscillatory neural activity in the theta band. The results suggest that the frontal component of the MMN is brought about by an increase in theta power for the deviant trials and, possibly, by an additional contribution of theta phase alignment. By contrast, the temporal component of the MMN, best seen in recordings from mastoid electrodes, is generated by phase resetting of theta rhythm with no concomitant power modulation. Thus, frontal and temporal MMN components do not only differ with regard to their functional significance but also appear to be generated by distinct neurophysiological mechanisms.