977 resultados para ultrasonic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic vocalization plays an important role in intraspecies communication for rats. It has been well demonstrated that rats will emit 22kHz vocalization in stressfiil or threatening situations. Although the neural mechanism underlying vocahzation is not well understood, it is known that chohnergic input to the basal forebrain induces such alarm calls. A number of experiments have found that intracerebral injection of carbachol, a predominantly muscarinic agonist, into die anterior hypothalamic/preoptic area (AH/POA) rehably induces vocalization similar to naturally emitted ultrasonic calls. It has also been shown that carbachol has extensive inhibitory effects on neuronal firing in the same area. This result impUes that the inhibitory effects of carbachol in the AH/POA could trigger vocahzation, and that the GABAergic system could be involved. The purpose of this study is to investigate the effects ofGABA agonists and antagonists on flie production of carbachol induced 22kHz vocalization. The following hypotheses were examined: 1) apphcation ofGABA (a naturally occurring inhibitory neurotransmitter) will have a synergistic effect with carbachol, increasing vocalization; and 2) tiie apphcation ofGABA antagonists (picrotoxin or bicuculline) will reduce caibachol-induced vocalization. A total of sixty rats were implanted with stainless steel guide cannulae in the AH/POA area. After recovery, animals were locally pretreated with 1) GABA (l-40ng), 2) picrotoxin (1 .5^g) or bicuculhne (0.03ng), or 3) sahne; before injection with carbachol (1 .5^g). The resulting vocalization was measured and quantitated. The results indicate that pretreatment with GABA or GABA antagonists had no significant effect on vocalization. Local pretreatment with GABA did not potentiate the vocal response as measured by its duration, latraicy, and total number of calls. Similarly, pretreatment with picrotoxin or bicuculline had no effects on the same measures of vocalization. The results suggest tfiat chohnoceptive neurons involved in the production of alarm calls are not under direct GABAergic control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rats produce ultrasonic vocalizations that can be categorized into two types of ultrasonic calls based on their sonographic structure. One group contains 22-kHz ultrasonic vocalization (USVs), characterized by relatively constant (flat) frequency with peak frequency ranging from 19 to 28-kHz, and a call duration ranging between 100 – 3000 ms. These vocalization can be induced by cholinomimetic agents injected into the ascending mesolimbic cholinergic system that terminates in the anterior hypothalamic-preoptic area (AH-MPO) and lateral septum (LS). The other group of USVs contains 50-kHz USVs, characterized by high peak frequency, ranging from 39 to 90-kHz, short duration ranging from 10-90 ms, and varying frequency and complex sonographic morphology. These vocalizations can be induced by dopaminergic agents injected into the nucleus accumbens, the target area for the mesolimbic dopaminergic system. 22-kHz USVs are emitted in situations that are highly aversive, such as proximity of a predator or anticipation of a foot shock, while 50 kHz USVs are emitted in rewarding and appetitive situations, such as juvenile play behaviour or anticipation of rewarding electrical brain stimulation. The activities of these two mesolimbic systems were postulated to be antagonistic to each other. The current thesis is focused on the interaction of these systems indexed by emission of relevant USVs. It was hypothesized that emission of 22 kHz USVs will be antagonized by prior activation of the dopaminergic system while emission of 50 kHz will be antagonized by prior activation of the cholinergic system. It was found that injection of apomorphine into the shell of the nucleus accumbens significantly decreased the number of carbachol-induced 22 kHz USVs from both AH-MPO and LS. Injection of carbachol into the LS significantly decreased the number of apomorphine-induced 50 kHz USVs from the shell of the nucleus accumbens. The results of the study supported the main hypotheses that the mesolimbic dopaminergic and cholinergic systems function in antagonism to each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rats produce ultrasonic vocalizations that can be categorized into two types of ultrasonic calls based on their sonographic structure. One group contains 22-kHz ultrasonic vocalization (USVs), characterized by relatively constant (flat) frequency with peak frequency ranging from 19 to 28-kHz, and a call duration ranging between 100 – 3000 ms. These vocalization can be induced by cholinomimetic agents injected into the ascending mesolimbic cholinergic system that terminates in the anterior hypothalamic-preoptic area (AH-MPO) and lateral septum (LS). The other group of USVs contains 50-kHz USVs, characterized by high peak frequency, ranging from 39 to 90-kHz, short duration ranging from 10-90 ms, and varying frequency and complex sonographic morphology. These vocalizations can be induced by dopaminergic agents injected into the nucleus accumbens, the target area for the mesolimbic dopaminergic system. 22-kHz USVs are emitted in situations that are highly aversive, such as proximity of a predator or anticipation of a foot shock, while 50 kHz USVs are emitted in rewarding and appetitive situations, such as juvenile play behaviour or anticipation of rewarding electrical brain stimulation. The activities of these two mesolimbic systems were postulated to be antagonistic to each other. The current thesis is focused on the interaction of these systems indexed by emission of relevant USVs. It was hypothesized that emission of 22 kHz USVs will be antagonized by prior activation of the dopaminergic system while emission of 50 kHz will be antagonized by prior activation of the cholinergic system. It was found that injection of apomorphine into the shell of the nucleus accumbens significantly decreased the number of carbachol-induced 22 kHz USVs from both AH-MPO and LS. Injection of carbachol into the LS significantly decreased the number of apomorphine-induced 50 kHz USVs from the shell of the nucleus accumbens. The results of the study supported the main hypotheses that the mesolimbic dopaminergic and cholinergic systems function in antagonism to each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central administration of orexin-A has been shown to activate autonomic arousal in rats, reliably inducing anxiety-like behaviours in the open field. To date, there has yet to be a study investigating the role of orexin-A in the communication of such negative affective state. In the current study, forty-six adult male rats were chronically cannulated and administered orexin-A into the medial preoptic area/anterior hypothalamic area to determine the effect of this neuropeptide on anxiety-like behaviour and the production of 22 kHz aversive ultrasonic vocalizations. It was found that intracerebral administration of orexin-A increased autonomic arousal as measured by a significant increase in fecal boli output, however orexin-A did not significantly affect locomotor activity or induce 22 kHz calling. These data suggest that orexin-A is involved in the regulation of the autonomic aspect of anxiety-like behaviour but not in the vocal communication of such negative affect

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is extensive evidence that the mesolimbic dopamine system underlies the production of 50 kHz ultrasonic vocalizations in rats. In particular, the shell of the nucleus accumbens is associated with generation of frequency modulated 50 kHz calls (a specific type of 50 kHz call which can be subdivided into various subtypes). There is also evidence that amphetamine administered systemically preferentially increases the proportion of trill and step calls compared to other frequency modulated 50 kHz subtypes. The purpose of this study was to investigate the effect of drug administration route and the role of the nucleus accumbens shell in amphetamine-induced 50 kHz call profile in the rat. Three experiments investigated this by using subcutaneous and intra-accumbens microinjections of amphetamine, as well as procaine (a local anesthetic) blockade of the nucleus accumbens. Ultrasonic vocalizations were recorded digitally from 24 rats and were analysed for sonographic structure based on general call parameters. The results of the three experiments were partially supportive of the hypotheses. Systemic amphetamine was found to induce greater bandwidth in 50 kHz calling compared to spontaneous calls in a vehicle condition. Systemic amphetamine was also found to preferentially increase the proportion of trill and step subtypes compared to vehicle. Moreover, there was no difference in the proportions of 50 kHz subtypes resulting from intracerebral or systemic application of amphetamine. There was, however, a significant difference for bandwidth, with systemic amphetamine inducing greater bandwidth over intraaccumbens application. Procaine blockade of the nucleus accumbens shell paired with subcutaneous amphetamine produced no difference in bandwidth of calls compared with those after a vehicle pre-treatment similarly paired. There was no reduction in the proportions of trill and step 50 kHz subtypes as well, with the procaine condition showing significantly greater proportion of step calls. The results of the study support a role for the iii nucleus accumbens shell in the amphetamine-induced changes on 50 kHz call profile. They also indicate there are more regions and pathways involved in generating 50 kHz calls than the projections from the ventral tegmental area to the nucleus accumbens. The implications of this work are that frequency modulated 50 kHz subtypes may be generated by distinct neurophysiological mechanisms and may represent a profitable avenue for investigating different circuits of 50 kHz call categories in the rat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis investigated the elastic properties and phase transitions in selected mixed sulphate crystals – Lithium Hydrazinium Sulphate [LiN2H2SO4], Lithium Ammonium Sulphate [LiNH4SO4] and Lithium Potassium Sulphate [LiKSO4] – using ultrasonic technique. The pulse echo overlap technique has been used for measuring ultrasonic velocity and its dependence on temperature along different directions with waves of longitudinal and transverse polarizations. Two major numerical techniques and the corresponding computer programs developed as part of present work are presented in this thesis. All the 9 elastic constants of LHS are determined accurately from ultrasonic measurements and applying misorientation correction refines the constants. Ultrasonic measurements are performed in LAS to determine the elastic constants and to study the low temperature phase transitions. Temperature variation studies of elastic constant of LAS are performed for 6 different modes of propagation for heating and cooling at low temperatures. All the 5 independent elastic constants of LPS is determined using ultrasonic measurements. It is concluded that LPS crystal does not undergo a phase transition near this temperature. A comparison of the three crystals studied shows that LPS has maximum number of phase transitions and LHS has the least number. It is interesting to note that LPS has the simplest formula unit among the three. There is considerable scope for the future work on these crystals and others belonging to the sulphate family.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is an attempt to probe the elastic properties in some dielectric ceramics, by using ultrasonic pulse echo overlap technique. The base Ba6-xSm8+2xTi18O54 and Ca5Nb2TiO12 are very important dielectrics ceramics used for microwave communication as well as for substrate materials. Ultrasonic is one of the most widely used and powerful techniques to measure elastic properties of solids. The ultrasonic technique is nondestructive in nature and the measurements are relatively straightforward to perform. One unique advantantage of the ultrasonic technique is that both static and dynamic properties can be measured simultaneously. The velocity and attenuation coefficients of the ultrasonic waves propagating through a medium are related to the microscopic structure of the material and they provide valuable information about the structural changes in the system. Among the various ultrasonic techniques, the pulse echo overlap method is the most accurate and precise one. In the present case the decreased elastic properties of Cas-XMg,Nb2TiO12 and Cas-,ZnNb2TiO12 ceramics can be attributed to their mixture phases beyond x = 1. Moreover, the abrupt change in elastic properties observed for x >1 can also be correlated to the structural transformation of the materials from their phase pure form to mixture phases for higher extent of substitution of the concerned material . Ca4(ANb2Ti)012 (A = Mg, Zn) is the strongest compound with the maximum values for elastic properties . This could be due to the possible substitution of Mg/Zn ions with lesser radius [25] than Ca2+ in perovskite B-site of Ca(Cali4Nb2i4Tili4) O3 material to contribute more ordering and symmetry to the system [20]. All other compositions (x > 1) contain mixed-phases and for such mixed-phase samples, the mechanical properties are difficult to explain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of carrying out this investigation is to develop suitable transducer array systems so that underwater pipeline inspection could be carried out in a much better way, a focused beam and electronic steering can reduce inspection time as well. Better results are obtained by optimizing the array parameters. The spacing between the elements is assumed to be half the wavelength so that the interelement interaction is minimum. For NDT applications these arrays are operated at MHz range. The wavelengths become very small in these frequency ranges. Then the size of the array elements becomes very small, requiring hybrid construction techniques for their fabrication. Transducer elements have been fabricated using PVDF as the active, mild steel as the backing and conducting silver preparation as the bonding materials. The transducer is operated in the (3,3) mode. The construction of a high frequency array is comparatively complicated. The interelement spacing between the transducer elements becomes considerably small when high frequencies are considered. It becomes very difficult to construct the transducer manually. The electrode connections to the elements can produce significant loading effect. The array has to be fabricated using hybrid construction techniques. The active materials has to be deposited on a proper substrate and etching techniques are required to fabricate the array. The annular ring, annular cylindrical or other similar structural forms of arrays may also find applications in the near future in treatments were curved contours of the human body are affected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic is a good tool to investigate the elastic properties of crystals. It enables one to determine all the elastic constants, Poisson’s ratios, volume compressibility and bulk modulus of crystals from velocity measurements. It also enables one to demonstrate the anisotropy of elastic properties by plotting sections of the surfaces of phase velocity, slowness, group velocity, Young’s modulus and linear compressibility along the a-b, b-c and a-c planes. They also help one to understand more about phonon amplification and help to interpret various phenomena associated with ultrasonic wave propagation, thermal conductivity, phonon transport etc. Study of nonlinear optical crystals is very important from an application point of view. Hundreds of new NLO materials are synthesized to meet the requirements for various applications. Inorganic, organic and organometallic or semiorganic classes of compounds have been studied for several reasons. Semiorganic compounds have some advantages over their inorganic and inorganic counterparts with regard to their mechanical properties. High damage resistance, high melting point, good transparency and non-hygroscopy are some of the basic requirements for a material to be suitable for device fabrication. New NLO materials are being synthesized and investigation of the mechanical and elastic properties of these crystals is very important to test the suitability of these materials for technological applications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed ultrasonic study of the elastic properties of lithium ammonium sulfate ~LiNH4SO4! or LAS has been carried out below room temperature. The elastic constants of LAS at room temperature are reported. The discrepancy present in earlier elastic constant data associated with the different choice of axes for this orthorhombic system are clarified. The results of the temperature variation study down to 220 K confirm the ferroelastic phase transition at 285 K and establish a thermal hysteresis of about 2.5 K between the cooling and heating cycles. Results of the investigation on the suspected weak phase transition at 256 K suggest that this transition occurs at 242 K on cooling and at 256 K on heating, thus having a thermal hysteresis of about 14 K. However, since the observed elastic anomaly for this transition is very small, the nature of this transition still remains unclear

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The double sulfate family (ABSO4), where A and B are alkali metal cations, is the object of great interest owing to the complexity and richness of its sequence of phase transition induced by temperature variation. A new sulfate salt characterized by the presence of water molecule in the unit cell with the chemical formula, Li2Na3(SO4)2⋅6H2O (LSSW), was obtained. The ultrasonic velocity measurement was done with pulse echo overlap technique [PEO]. All the six second order elastic stiffness constants, C11 = C22, C33, C44 = C55, C12, C14 and C13 = C23 are reported for the first time. The anisotropy in the elastic properties of the crystal are well explained by the pictorial representation of the polar plots of phase velocity, slowness, Young’s modulus and linear compressibility in a–b and a–c planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Certain organic crystals are found to possess high non- linear optical coefficients,often one to two orders of magnitude higher than those of the well known inorganic non-linear optical materials.Benzoyl glycine is one such crystal whose optical second-harmonic generation efficiency is much higher than that of potassium dihydrogen phosphate. Single crystals of benzoyl glycine are grown by solvent evaporation technique using N,N-dimethyl formamide as the solvent.All the nine second-order elastic stiffness constants of this orthorhombic crystal are determined from ultrasonic wave velocity measurements employing the pulse echo overlap technique.The anisotropy of elastic wave propagation in this crystal is demonstrated by plotting the phase velocity, slowness,Young's modulus and linear compressibility surfaces along symmetry planes.The volume compressibility, bulk modulus and relevant Poisson's ratios are also determined. Variation of the diagonal elastic stiffness constants with temperature over a limited range are measured and reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes development of micro-fabricated piezoelectric ultrasonic motors and bulk-ceramic piezoelectric ultrasonic motors. Ultrasonic motors offer the advantage of low speed, high torque operation without the need for gears. They can be made compact and lightweight and provide a holding torque in the absence of applied power, due to the traveling wave frictional coupling mechanism between the rotor and the stator. This report covers modeling, simulation, fabrication and testing of ultrasonic motors. Design of experiments methods were also utilized to find optimal motor parameters. A suite of 8 mm diameter x 3 mm tall motors were machined for these studies and maximum stall torques as large as 10^(- 3) Nm, maximum no-load speeds of 1710 rpm and peak power outputs of 27 mW were realized. Aditionally, this report describes the implementation of a microfabricated ultrasonic motor using thin-film lead zirconate titanate. In a joint project with the Pennsylvania State University Materials Research Laboratory and MIT Lincoln Laboratory, 2 mm and 5 mm diameter stator structures were fabricated on 1 micron thick silicon nitride membranes. Small glass lenses placed down on top spun at 100-300 rpm with 4 V excitation at 90 kHz. The large power densities and stall torques of these piezoelectric ultrasonic motors offer tremendous promis for integrated machines: complete intelligent, electro-mechanical autonomous systems mass-produced in a single fabrication process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this pilot study was to survey dentists in the St. Louis area to assess their subjective opinion of commonly used dental handpieces as well as history of noise exposure and use of hearing protection. Selected handpieces were then chosen to measure their output levels and determine if emissions are hazardous to the auditory system.