818 resultados para titanium device
Resumo:
To the Editor: The value of angiotensin-converting– enzyme (ACE) inhibitors, beta-blockers, and spironolactone has been well established by the results of numerous clinical trials. About 70 percent of the patients described by Rose et al. were treated with ACE inhibitors or angiotensin II–receptor antagonists; 35 to 40 percent received spironolactone, and only about 20 percent received beta-blockers. Thus, this population cannot have been considered to be optimally treated from the point of view of medical therapy.
Resumo:
Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.
Resumo:
QDius2 és una aplicació pensada per a persones amb discapacitat visual. Consisteix en realitzar una descripció verbalitzada de l’estat d’un electrodomèstic utilitzant un dispositiu mòbil amb sistema operatiu Android. L’aplicació guiarà verbalment l’usuari perquè pugui enfocar el panell de control de l’electrodomèstic amb la càmera. Es processarà la imatge obtinguda per extreure la seva informació, ja sigui en el mateix mòbil o al núvol, segons les preferències de l’usuari, i es llegirà la informació resultant. Aquest projecte està dividit en vuit memòries, una per a cada integrant del grup.
Resumo:
Background. This study is an evaluation of the vacuum-assisted closure (VAC) therapy for the treatment of severe intrathoracic infections complicating lung resection, esophageal surgery, viscera perforation, or necrotizing pleuropulmonary infections.Methods. We reviewed the medical records of all patients treated by intrathoracic VAC therapy between January 2005 and December 2008. All patients underwent surgical debridement-decortication and control of the underlying cause of infection such as treatment of bronchus stump insufficiency, resection of necrotic lung, or closure of esophageal or intestinal leaks. Surgery was followed by intrathoracic VAC therapy until the infection was controlled. The VAC dressings were changed under general anesthesia and the chest wall was temporarily closed after each dressing change. All patients received systemic antibiotic therapy.Results. Twenty-seven patients (15 male, median age 64 years) underwent intrathoracic VAC dressings for the management of postresectional empyema (n = 8) with and without bronchopleural fistula, necrotizing infections (n = 7), and intrathoracic gastrointestinal leaks (n = 12). The median length of VAC therapy was 22 days (range 5 to 66) and the median number of VAC changes per patient was 6 (range 2 to 16). In-hospital mortality was 19% (n = 5) and was not related to VAC therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in all surviving patients.Conclusions. Vacuum-assisted closure therapy is an efficient and safe adjunct to treat severe intrathoracic infections and may be a good alternative to the open window thoracostomy in selected patients. Long time intervals in between VAC changes and short course of therapy result in good patient acceptance. (Ann Thorac Surg 2011;91:1582-90) (C) 2011 by The Society of Thoracic Surgeons
Resumo:
The use of cages of different material and shapes for cervical discectomy with fusion (ACDF) has increased during the last few years. The use of additional osteogenic material is controversial. We prospectively evaluated an empty, Plasmapore-covered titanium cage (PCTC) in 45 patients undergoing 58 ACDFs. Patients were evaluated using standard clinical and radiological criteria. Good to excellent outcome was achieved in 93%, 78% and 75% after 3, 12 and 48 months, respectively. Sixty-five percent of patients could resume their prior work after 48 months. Disc space height and lordosis could be preserved in all cases. Two percent of the treated levels showed subsidence and 2% increased segmental motion. There were no procedure-related complications. Implantation of an empty PCTC after microsurgical anterior cervical discectomy is a safe procedure with good results and low incidence of complications. Disc height and lordosis can be preserved with low incidence of subsidence and good fusion rates.
Resumo:
A model of directed search with a finite number of buyers and sellers is considered, where sellers compete in direct mechanisms. Buyer heterogeneity and Nash equilibrium results in perfect sorting. The restriction to complementary inputs, that the match value function Q is supermodular, in addition coordinates the sellers strategies. In that case, equilibrium implements positive assortative matching, which is efficient and consistent with the stable (cooperative equilibrium) outcome. This provides a non-cooperative and decentralizedsolution for the Assignment Game. Conversely, if buyers are identical, no such coordination is possible, and there is a continuum of equilibria, one of which exhibits price posting, another yields competition in auctions.
Resumo:
This paper studies a balance whose unobservable fulcrum is not necessarilylocated at the middle of its two pans. It presents three differentmodels, showing how this lack of symmetry modifies the observation, theformalism and the interpretation of such a biased measuring device. Itargues that the biased balance can be an interesting source of inspirationfor broadening the representational theory of measurement.
Resumo:
Executive Summary The use of full-body restraint devices is a widespread practice in Iowa’s county jails. Full-body restraints come in the form of restraint chairs, boards, and beds, including two such devices manufactured in Iowa. Iowa law, which refers to these as four- and fivepoint restraints, states they are only to be used when an inmate is a threat to self, others, or jail security. However, the Ombudsman found they were also used on inmates who caused minor disruptions or in response to an inmate’s verbal abuse. In some cases, the restraints were used on inmates with known mental illness who were acting out, though no attempts were made to seek medical or mental health reviews for those inmates while restrained, leading to extended use of the restraint device.
Resumo:
OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.
Resumo:
BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.