970 resultados para therapeutical ultrasound
Resumo:
Computed Tomography (CT) represents the standard imaging modality for tumor volume delineation for radiotherapy treatment planning of retinoblastoma despite some inherent limitations. CT scan is very useful in providing information on physical density for dose calculation and morphological volumetric information but presents a low sensitivity in assessing the tumor viability. On the other hand, 3D ultrasound (US) allows a highly accurate definition of the tumor volume thanks to its high spatial resolution but it is not currently integrated in the treatment planning but used only for diagnosis and follow-up. Our ultimate goal is an automatic segmentation of gross tumor volume (GTV) in the 3D US, the segmentation of the organs at risk (OAR) in the CT and the registration of both modalities. In this paper, we present some preliminary results in this direction. We present 3D active contour-based segmentation of the eye ball and the lens in CT images; the presented approach incorporates the prior knowledge of the anatomy by using a 3D geometrical eye model. The automated segmentation results are validated by comparing with manual segmentations. Then, we present two approaches for the fusion of 3D CT and US images: (i) landmark-based transformation, and (ii) object-based transformation that makes use of eye ball contour information on CT and US images.
Resumo:
PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 μm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.
Resumo:
Segmenting ultrasound images is a challenging problemwhere standard unsupervised segmentation methods such asthe well-known Chan-Vese method fail. We propose in thispaper an efficient segmentation method for this class ofimages. Our proposed algorithm is based on asemi-supervised approach (user labels) and the use ofimage patches as data features. We also consider thePearson distance between patches, which has been shown tobe robust w.r.t speckle noise present in ultrasoundimages. Our results on phantom and clinical data show avery high similarity agreement with the ground truthprovided by a medical expert.
Resumo:
Parmi les neuroleptiques disponibles, l'amisulpride est de plus en plus prescrit. De par son affinité sélective dose-dépendante aux récepteurs dopaminergiques, il est possible de moduler les effets de cette substance montrant des propriétés antidépressives à faible dose et agissant comme un puissant antipsychotique à forte dose. Toutefois, l'amisulpride induit une prolongation dose-dépendante de l'intervalle QT ce qui peut potentialiser la survenue d'arythmies ventriculaires, souvent fatales lorsque sa consommation est concomitante à celles d'autres médicaments ou stupéfiants allongeant l'intervalle QT. Cependant, la littérature scientifique demeure peu documentée en ce qui concerne la détermination de concentrations sanguines thérapeutiques, toxiques et létales. Après avoir présenté les propriétés pharmacodynamiques et pharmacocinétiques de l'amisulpride, nous nous proposons de définir plus précisément les seuils sanguins de concentrations thérapeutiques, toxiques et létales pour cette molécule illustrée par la revue des cas mortels impliquant l'amisulpride en Suisse romande depuis 2005. Among the available neuroleptic drugs, amisulpride is increasingly prescribed. Thanks to its dose-dependent selective affinity for dopamine receptors, it is possible to modulate the effects of this substance showing antidepressant properties at low dose and acting as a powerful antipsychotic at high dose. However, amisulpride induces a dose-dependent prolongation of the QT interval which may potentiate the occurrence of ventricular arrhythmias, often fatal when its consumption is concomitant with those of other drugs that prolong the QT interval. However, the scientific literature remains poorly documented with regard to the determination of therapeutic, toxic and lethal blood concentrations. After presenting the pharmacodynamic and pharmacokinetic properties of amisulpride, we propose to define more precisely the blood levels of therapeutic, toxic and lethal concentrations for this molecule illustrated by a review of the fatal cases involving amisulpride in Western Switzerland since 2005.
Resumo:
PURPOSE: To use diffusion-tensor (DT) magnetic resonance (MR) imaging in patients with essential tremor who were treated with transcranial MR imaging-guided focused ultrasound lesion inducement to identify the structural connectivity of the ventralis intermedius nucleus of the thalamus and determine how DT imaging changes correlated with tremor changes after lesion inducement. MATERIALS AND METHODS: With institutional review board approval, and with prospective informed consent, 15 patients with medication-refractory essential tremor were enrolled in a HIPAA-compliant pilot study and were treated with transcranial MR imaging-guided focused ultrasound surgery targeting the ventralis intermedius nucleus of the thalamus contralateral to their dominant hand. Fourteen patients were ultimately included. DT MR imaging studies at 3.0 T were performed preoperatively and 24 hours, 1 week, 1 month, and 3 months after the procedure. Fractional anisotropy (FA) maps were calculated from the DT imaging data sets for all time points in all patients. Voxels where FA consistently decreased over time were identified, and FA change in these voxels was correlated with clinical changes in tremor over the same period by using Pearson correlation. RESULTS: Ipsilateral brain structures that showed prespecified negative correlation values of FA over time of -0.5 or less included the pre- and postcentral subcortical white matter in the hand knob area; the region of the corticospinal tract in the centrum semiovale, in the posterior limb of the internal capsule, and in the cerebral peduncle; the thalamus; the region of the red nucleus; the location of the central tegmental tract; and the region of the inferior olive. The contralateral middle cerebellar peduncle and bilateral portions of the superior vermis also showed persistent decrease in FA over time. There was strong correlation between decrease in FA and clinical improvement in hand tremor 3 months after lesion inducement (P < .001). CONCLUSION: DT MR imaging after MR imaging-guided focused ultrasound thalamotomy depicts changes in specific brain structures. The magnitude of the DT imaging changes after thalamic lesion inducement correlates with the degree of clinical improvement in essential tremor.
Resumo:
OBJECTIVES: To evaluate prenatal diagnosis of congenital heart diseases by ultrasound investigation in well-defined European populations. DESIGN: Data from 20 registries of congenital malformations in 12 European countries were included. The prenatal ultrasound screening programs in the countries ranged from no routine screening to three ultrasound investigations per patient routinely performed. RESULTS: There were 2454 cases with congenital heart disease with an overall prenatal detection rate of 25%. Termination of pregnancy was performed in 293 cases (12%). There was considerable variation in prenatal detection rate between regions, with the lowest detection rates being in countries without ultrasound screening (11%) and in Eastern European countries (Croatia, Lithuania and Ukraine; 8%). In Western European countries with ultrasound screening, detection rate ranged from 19-48%. There was a significant difference in prenatal detection rate and proportion of induced abortions between isolated congenital heart disease and congenital heart disease associated with chromosome anomalies, multiple malformations and syndromes (P < 0.0001). There were 1694 cases with isolated congenital heart disease of which 16% were diagnosed prenatally. Malformations affecting the size of the ventricles were detected prenatally in half of the cases. CONCLUSIONS: Prenatal detection rate of congenital heart disease varies significantly between countries even with the same screening recommendations. The presence of associated malformations significantly increases the prenatal detection rate.
Resumo:
Purpose: Tumour-free resection margins (RMs) are mandatory in breast-conserving surgery. On-site intraoperative ultrasound (US)-guided tumour resection with extemporaneous histopathological assessment of RMs has been described. Remote intraoperative US assessment of RMs is an alternative. The purpose of this study was to evaluate the relationship of lumpectomy RMs measurements between remote intraoperative US and postoperative histopathology.Methods and Materials: In a retrospective IRB-approved review of 100 consecutive lumpectomies performed between October 2009 and April 2011 for presumed non-palpable breast cancer, 71 women (mean age 63.8years) were included. Twenty-nine patients were excluded because of absence of cancer at histopathology and/or incomplete data. Measurements of lumpectomy minimal RMs and tumour maximal diameter obtained on remote intraoperative US and postoperative histopathology were compared.Results: Minimal RMs were 0.35±0.32 (mean±SD) and 0.35±0.32cm on remote intraoperative US and postoperative histopathology, respectively. No significant difference was found between these measurements (p=0.37). Tumour maximal diameter was 1.02±0.51 (mean±SD) and 1.33±0.74cm on remote intraoperative US and postoperative histopathology, respectively. US measurements were significantly smaller (p<0.001). The 71 breast carcinoma (CA) consisted of: invasive canalar (n=49), invasive lobular (n=11), in situ (n=3) and other types of CA (n=8). Twenty-nine patients had intraoperative re-excision (24 without residual CA), while 16 patients were re-operated due to insufficient histopathological RMs (12 without residual CA).Conclusion: Good correlation of minimal RMs between remote intraoperative US and postoperative histopathology warrants use of both techniques in a complementary manner. Remote intraoperative US is helpful in taking rapid decision of re-excision and maintaining low re-operation rate after breast-conserving surgery for non-palpable cancer.
Resumo:
The purpose was to evaluate the influence of radiologist's experience on the diagnostic yield and complications of a percutaneous liver biopsy (PLB) method. Six hundred patients underwent an ultrasound-guided PLB by an inexperienced operator in 25.2% of cases (experience of less than 15 percutaneous liver biopsies performed alone--group I) or by an experienced operator (experience of more than 150 percutaneous liver biopsies--group II). The two groups were well-matched with respect to sex, age, percentage with viral hepatitis without histological cirrhosis, number of needle passes, history of liver biopsy and pain before the biopsy. A histological diagnosis was available in 97.3% of cases without any significant difference between the two groups ( P=0.25). However, group II samples were significantly longer and contained more portal tracts ( P=0.01). Pain was mild immediately and 6 h after the biopsy, without significant difference between both groups. Eight vasovagal reactions (five in group II) and one arteriobiliary fistula (in group II) occurred. With the method of PLB used for this study, operator's experience did not influence either the final histological diagnosis or the degree of pain suffered.
Resumo:
Objective: The treatment of choice in end-stage renal disease is¦transplantation.¦Hemodynamic disturbances can evoke graft loss, while early ultrasound¦identification of vascular problems improves outcome. The primary endpoint¦of this study was to identify differences in post-op complications with and¦without systematic, intraoperative Doppler ultrasound use. A secondary aim¦was to find a predictive resistance index limit which would show where surgical¦reintervention was necessary.¦Methods: Between Jan 2000 and Dec 2010, 108 renal transplants were¦performed from living donors at our institution. In group 1 (n = 67),¦intra-operative duplex ultrasound and intra-parenchymatous resistance index¦measurements assessed patients, while in group 2 (n = 41), no ultrasound was¦performed.¦Results. There were no inter-group differences in the overall post-op¦complication rate or in benefit to graft or patient survival with Doppler use,¦however, significantly more vascular complications (10% vs. 0%, p = 0·02) and¦more acute rejections (37% vs. 10%) occurred in group 2 than in group 1,¦respectively. When the resistance index was <0·5 intra-operatively, immediate¦surgical revision was undertaken to raise the index >0·6.¦Results: There were no inter-group differences in the overall post-op¦complication rate or in benefit to graft or patient survival with Doppler use,¦however, significantly more vascular complications (10% vs. 0%, p = 0·02) and¦more acute rejections (37% vs. 10%) occurred in group 2 than in group 1,¦respectively. When the resistance index was <0·5 intra-operatively, immediate¦surgical revision was undertaken to raise the index >0·6.¦Conclusion: This is the first report demonstrating benefits of systematic¦intraoperative Doppler ultrasound on post-operative complications in renal¦transplantation from living donors. Our results support surgical revision with a¦resistance index <0·5.
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
Five years of experience with endovascular infrarenal aneurysm repair at our institution is reviewed. Implantation of endoprostheses in 88 patients has been performed by surgeons using exclusively intravascular ultrasound (IVUS) and fluoroscopy. IVUS identified the target site of deployment in all cases. In-hospital morbidity was 22% (19/88). Two percent mortality (2/88) and 5% early conversion (4/88) as a consequence of type I endoleaks were noted only in the first 53 patients with early devices (NS). Early endoleaks were present in 36% (32/88) including twenty-two type I, five type II and five type III endoleaks. Proximal endoleaks were associated with early devices (P<0.001), and technical difficulties with deployment. Tube grafts used in the beginning, performed poorly with 54% (7/13) type I endoleaks. Endoleaks diminished to 10% (9/88) by spontaneous closure and secondary endovascular procedures that were necessary in 24% (21/88) and consisted of coil embolization/cuff extension (9), late conversion (6), and limb recanalization or femoral cross-over bypass (6). Endovascular aneurysm repair using IVUS is a valid alternative technique. Improved devices and systematic use of bifurcated endoprostheses for infrarenal aneurysms reduce the occurrence of type I endoleaks.