997 resultados para technetium Tc 99m dextran
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.
Resumo:
CYCLOTech is a high-tech Project, related with an innovative method for direct production of a radioactive pharmaceutical, used in excess of 85% of 35 Million Nuclear Medicine procedures done yearly, worldwide, representing globally more than 3 Billion Euros. The CYCLOTech team has developed an innovative proprietary methodology based on the use of Cyclotron Centers, formally identified as the Clients (actually, there are around 450 of this Centers in function worldwide), to directly produce and deliver the radiopharmaceutical to the final users, at the Hospitals and other Health Institutions (estimating at around 25.000, worldwide). The investment still need to finish Research and Technological Development (RTD), Industrial, Regulatory and Intellectual Property Rights (IPR) issues and allow the introduction in the Market is 4,35 M€, with a Payback of 3 years, with an Investment Return Rate (IRR) of 81,7% and a Net Present Value (NPV) of 60.620.525€ (in 2020).
Resumo:
A delimitação precisa é crucial na RT. TC: informação anatómica, pobre na definição do envolvimento ganglionar; alguns tumores são praticamente invisíveis (p.e., esófago, fígado, baço e glândulas salivares), mapa de densidades electrónicas essencial para o cálculo. 18F-FDG PET: 1) mapeamento metabólico que permite alterar volumes alvo: BTV, elimina incertezas no GTV; 2) vantagens: estadiamento tumoral, predição da resposta tumoral, avaliação da resposta tumoral, detecção precoce da doença recorrente. PET/TC: maior precisão, menor variabilidade inter e intra-observador, menor erro no reposicionamento, adaptação à RT, ainda em Investigação Clínica.
Resumo:
Objetivo do estudo - Comparar as amplitudes respiratórias segundo os eixos x, y e z adquiridos com a tomografia computorizada (TC) 4D e o sistema Calypso® em cancro de pulmão.
Resumo:
The polypeptides of 46 and 58kDa were recognized in different T. cruzi strains (Y, WSL and Colombiana) by serum of all chagasic patients studied. These polypeptides were isolated from T. cruzi Y strain and used in ELISA. The sensitivity and specificity were 97.6% [CI 95%: 86-100%] and 100% [CI 95%: 89.3-100%], respectively when Tc 46 was used. When Tc 58 was used the sensitivity and specificity were 100% [CI 95%: 89.6-100%] and 90.2% [CI 95%: 75.9-96.8%], respectively.
Resumo:
RESUMO - A exposição a radiações ionizantes em tomografia computorizada (TC) pode constituir-se como um risco para a saúde dos utentes. A TC é utilizada no diagnóstico e follow-up de doentes com Linfoma não-Hodgkin, subtipo Linfoma Difuso das Grandes Células B (LDGCB). O objetivo deste estudo foi determinar a dose efetiva acumulada e o risco de segundas neoplasias nestes doentes, diagnosticados em 2011 no IPOLFG e seguidos na consulta de hematologia até 2013. Foram avaliados retrospetivamente 70 doentes com base nos registos de dose do “Patient Protocol” das TC efetuadas. Em média cada doente fez 12 TC e a dose efetiva acumulada foi de 64,76 mSv (percentil 75). Três doentes foram expostos a doses de radiação superiores 90 mSv e um atingiu 111,72 mSv. Os resultados demonstram ser necessário rever os parâmetros e protocolos de exames de TC: (i) TC crânio (DLP= 777 mGycm) e TC abdominal-pélvico (DLP= 628 mGycm). O aumento do número de exames de TC efetuados e a consequente dose parece corresponder a um aumento do risco de segundas neoplasias e risco de morte por doenças neoplásicas durante a vida destes doentes. Os resultados são aparentemente mais significativos para as mulheres, que apresentam o dobro do risco de cancro do pulmão e risco de mortalidade superior em 14% para todas as doenças neoplásicas. O elevado número de exames de TC realizados por cada doente contribui para o aumento da probabilidade de efeitos deletérios e também para o aumento dos níveis de dose efetiva coletiva na população em geral.
Resumo:
OBJECTIVE: To evaluate and compare the usefulness of cineventriculographies, before and after nitrate use, to technetium-99m sestamibi scintigraphy for the identification of myocardial ischemia. METHODS: Twenty-six patients were studied at basal conditions and 5 minutes after intravenous administration of isosorbide mononitrate (0.3mg/kg), to evaluate the performance and regional wall motion of the left ventricle (LV). The results were compared to those obtained with technetium-99m sestamibi scintigraphy. RESULTS: Before nitrate, contrast ventriculography identified 30 normal segments, 62 hypokinetic segments, 28 dyskinetic segments, and 14 akinetic segments. After drug administration, 99 segments were normal, 11 hypokinetic, 11 dyskinetic, and 13 akinetic. Myocardial scintigraphy revealed 110 ischemic segments and 18 fibrotic segments (p<0.005). After drug administration, the ventriculography showed increase in the velocity of circumferential fiber shortening (p=0.0142), the ejection fraction (p=0.0462), decrease in the end-systolic volume (p=0.0031) and no change in end-diastolic volume. CONCLUSION: Contrast ventriculography using nitrate proved to be similar to perfusional myocardial scintigraphy in the identification of myocardial ischemia.
Resumo:
Fluorescence in situ hybridization (FISH) is a molecular technique widely used for the detection and characterization of microbial populations. FISH is affected by a wide variety of abiotic and biotic variables and the way they interact with each other. This is translated into a wide variability of FISH procedures found in the literature. The aim of this work is to systematically study the effects of pH, dextran sulfate and probe concentration in the FISH protocol, using a general peptide nucleic acid (PNA) probe for the Eubacteria domain. For this, response surface methodology was used to optimize these 3 PNA-FISH parameters for Gram-negative (Escherichia coli and Pseudomonas fluorescens) and Gram-positive species (Listeria innocua, Staphylococcus epidermidis and Bacillus cereus). The obtained results show that a probe concentration higher than 300 nM is favorable for both groups. Interestingly, a clear distinction between the two groups regarding the optimal pH and dextran sulfate concentration was found: a high pH (approx. 10), combined with lower dextran sulfate concentration (approx. 2% [w/v]) for Gram-negative species and near-neutral pH (approx. 8), together with higher dextran sulfate concentrations (approx. 10% [w/v]) for Gram-positive species. This behavior seems to result from an interplay between pH and dextran sulfate and their ability to influence probe concentration and diffusion towards the rRNA target. This study shows that, for an optimum hybridization protocol, dextran sulfate and pH should be adjusted according to the target bacteria.
Resumo:
Partition behavior of adenosine and guanine mononucleotides was examined in aqueous dextran-polyethylene glycol (PEG) and PEG-sodium sulfate two-phase systems. The partition coefficients for each series of mononucleotides were analyzed as a functions of the number of phosphate groups and found to be dependent on the nature of nucleic base and on the type of \ATPS\ utilized. It was concluded that an average contribution of a phosphate group into logarithm of partition coefficient of a mononucleotide cannot be used to estimate the difference between the electrostatic properties of the coexisting phases of ATPS. The data obtained in this study were considered together with those for other organic compounds and proteins reported previously, and the linear interrelationship between logarithms of partition coefficients in dextran-PEG, PEG-Na2SO4 and PEG-Na2SO4-0.215 M NaCl (all in 0.01 M Na- or K/Na-phosphate buffer, pH 7.4 or 6.8) was established. Similar relationship was found for the previously reported data for proteins in Dex-PEG, PEG-600-Na2SO4, and PEG-8000-Na2SO4 ATPS. It is suggested that the linear relationships of the kind established in \ATPS\ may be observed for biological properties of compounds as well.
Resumo:
We report a rare case of anomalous origin of the left coronary artery from the pulmonary trunk in a 45-year-old woman. The approach and technique used for selective catheterization of an anomalous left coronary artery arising from the pulmonary trunk are described. Six years after diagnosis, echocardiography showed left ventricular disfunction, and surgical treatment was indicated again. The origin of the left coronary artery from the pulmonary trunk was closed, and the postoperative period was uneventful, with recovery of left ventricular function and disappearance of ischemic features on stress myocardial perfusion imaging with 99m Tc-sestamibi, performed 4 weeks after surgery.
Resumo:
OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM) com Tecnécio 99m-MIBI (MIBI) e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ) e o ultra-som intracoronário (UIC) como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC), encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG) e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E%) de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79%) e média de 44,20%, p<0,05. Infradesnível de ST durante adenosina associou-se a maiores graus de E% (55,0% vs 47,8%), p<0,05). A isquemia cintilográfica correlacionou-se a maior área porcentual de obstrução da luz pelo UIC (AO%). Os achados clínicos, do ECG e das imagens foram considerados em conjunto e expressos como respostas globais isquêmicas versus não-isquêmicas . A isquemia associou-se a menores valores do diâmetro mínimo da luz (DML) e da área mínima da luz (AML), obtidos à ACQ e ao UIC. CONCLUSÃO: A cintilografia do miocárdio com 99mTc-MIBI e adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão. Na avaliação dos resultados globais da prova observa-se associação com os diâmetros e as áreas da luz nos locais de obstrução, obtidos à ACQ e ao UIC.
Resumo:
FUNDAMENTO: A doença cardiovascular é a principal causa de morte em diabéticos, tornando-se primordial a identificação dos indivíduos sob maior risco de eventos cardiovasculares. OBJETIVO: Avaliar o valor prognóstico da cintilografia miocárdica de perfusão com " gated SPECT" em pacientes com diabete melito (DM) e suspeita clínica de doença arterial coronariana. MÉTODOS: Estudo retrospectivo envolvendo 232 pacientes diabéticos submetidos à cintilografia miocárdica com " gated SPECT" . Foram avaliados os parâmetros da cintilografia de perfusão (escores e número de segmentos alterados) e da função ventricular (fração de ejeção, volumes e contratilidade do ventrículo esquerdo). Foram considerados eventos cardiovasculares futuros ocorrência de óbito cardíaco, síndrome coronariana isquêmica aguda, procedimentos de revascularização ou acidente vascular encefálico. Foi realizada a análise uni e multivariada pelo modelo de regressão logística múltipla (p < 0,05). RESULTADOS: Estiveram associados com desfechos futuros na análise univariada: idade (p=0,02); angina de peito (p=0,01); tratamento com insulina (p=0,02); anormalidades na perfusão miocárdica (p<0,0001); número de segmentos envolvidos (p=0,0001); escores de perfusão (p=0,0001); fração de ejeção (p=0,004); volume sistólico final (p=0,03) e achado de alteração segmentar na contratilidade do VE (p<0,0001). Na análise multivariada, o sexo masculino (p=0,007), a idade (p=0,03), a angina (p=0,001), o uso de insulina (p=0,007) e o SDS > 3 (p=0,0001) e o número de segmentos alterados > 3 (p=0,0001) foram preditores de eventos. CONCLUSÃO: A cintilografia miocárdica com " gated SPECT" adiciona informações independentes para a estratificação do risco de eventos cardiovasculares futuros em pacientes com diabete melito e suspeita de doença arterial coronariana.
Desfechos clínicos após investigação para Embolia Pulmonar utilizando TC de tórax/membros inferiores
Resumo:
FUNDAMENTO: O diagnóstico de Embolia Pulmonar (EP) ainda requer longos períodos de trabalho e inúmeros testes. OBJETIVO: Nosso objetivo é avaliar os desfechos clínicos após uma investigação negativa usando um protocolo combinado de angio TC de tórax e venografia por TC (CTA/CTV) como único teste de diagnóstico em pacientes não selecionados com suspeita de EP. MÉTODOS: Estudo de coorte retrospectivo que incluiu pacientes consecutivos com suspeita de EP que foram investigados com um protocolo combinado de CTA/CTV. Os pacientes que apresentaram inicialmente uma investigação negativa e não receberam anticoagulantes foram acompanhados por seis meses para ocorrência de eventos tromboembólicos venosos recorrentes. RESULTADOS: De 425 pacientes com suspeita de EP, 62 (14,6%) tiveram diagnóstico de tromboembolismo venoso no CTA/CTV inicial. A média de idades foi de 56 ± 19 anos, e 61% da população se enquadravam na categoria de baixa probabilidade clínica. A trombose venosa profunda isolada representou 21% de todos os eventos tromboembólicos venosos, e quando se considerou toda a população, a CTV foi associada a um incremento no rendimento diagnóstico de 3,1%. Nosso grupo era composto de 320 pacientes com CTA/CTV inicialmente negativo e que não receberam anticoagulantes. Após seis meses de acompanhamento, apenas três pacientes apresentaram recorrência de eventos tromboembólicos (0,9%, IC 95% -0,1% - 2,0%) e nenhum foi fatal. Não houve mortes relacionadas com a EP. CONCLUSÕES: Nosso estudo sugere que uma estratégia de diagnóstico que utiliza CTA/CTV como único teste de diagnóstico pode descartar EP com segurança, em população com risco baixo a moderado, e está associada a resultados favoráveis, com um valor preditivo negativo de 99,1%. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0)