980 resultados para steady-state operation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Renewable or sustainable energy (SE) sources have attracted the attention of many countries because the power generated is environmentally friendly, and the sources are not subject to the instability of price and availability. This dissertation presents new trends in the DC-AC converters (inverters) used in renewable energy sources, particularly for photovoltaic (PV) energy systems. A review of the existing technologies is performed for both single-phase and three-phase systems, and the pros and cons of the best candidates are investigated. In many modern energy conversion systems, a DC voltage, which is provided from a SE source or energy storage device, must be boosted and converted to an AC voltage with a fixed amplitude and frequency. A novel switching pattern based on the concept of the conventional space-vector pulse-width-modulated (SVPWM) technique is developed for single-stage, boost-inverters using the topology of current source inverters (CSI). The six main switching states, and two zeros, with three switches conducting at any given instant in conventional SVPWM techniques are modified herein into three charging states and six discharging states with only two switches conducting at any given instant. The charging states are necessary in order to boost the DC input voltage. It is demonstrated that the CSI topology in conjunction with the developed switching pattern is capable of providing the required residential AC voltage from a low DC voltage of one PV panel at its rated power for both linear and nonlinear loads. In a micro-grid, the active and reactive power control and consequently voltage regulation is one of the main requirements. Therefore, the capability of the single-stage boost-inverter in controlling the active power and providing the reactive power is investigated. It is demonstrated that the injected active and reactive power can be independently controlled through two modulation indices introduced in the proposed switching algorithm. The system is capable of injecting a desirable level of reactive power, while the maximum power point tracking (MPPT) dictates the desirable active power. The developed switching pattern is experimentally verified through a laboratory scaled three-phase 200W boost-inverter for both grid-connected and stand-alone cases and the results are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

TRIB2 is a member of the mammalian Tribbles family of serine/threonine pseudokinases (TRIB1-3). Here, we studied murine haematopoiesis after Trib2 ablation under steady state and proliferative stress conditions, including genotoxic and oncogenic stress. At the steady state, we found that TRIB2 loss did not adversely affect peripheral blood cell counts and populations. No detectable significant differences were found in the populations of haematopoietic stem and progenitor cells. However, Trib2-/- mice had significantly higher thymic cellularity due to the increased proliferation of Trib2-/- developing thymocytes which give rise to increased number of mature thymic subsets. During stressed haematopoiesis, Trib2-/- developing thymocytes demonstrate hypersensitivity to 5-fluorouracil-induced cell death. Nevertheless, Trib2-/- mice exhibit accelerated thymopoietic recovery post 5-fluorouracil treatment due to increased cell division kinetics of developing thymocytes. In an experimental murine T-cell acute lymphoblastic leukaemia (T-ALL) model, Trib2-/- mice had reduced latency in vivo which associated with aggressive T-ALL phenotypes and impaired activation of mitogen-activated protein kinase. Gene set enrichment analysis showed that TRIB2 expression is elevated in immature subtype of human T-ALL enriched with mitogen-activated protein kinase signalling. However, TRIB2 expression is suppressed in mature subtype of human T-ALL. Thus, TRIB2 emerges as a novel regulator of thymocyte cellular proliferation, important for the thymopoietic response to genotoxic and oncogenic stress, and possessing tumour suppressor function. In Drosophila, Tribbles promotes degradation of String which is an orthologue of mammalian CDC25 phosphatases in order to arrest cell cycle during embryonic development. Here, we showed that the role of Tribbles-induced degradation of String is evolutionarily conserved in TRIB2. We found that TRIB2 interacts with CDC25B/C but not CDC25A isoform. Overexpression of TRIB2 promotes polyubiquitination and degradation of CDC25C. Hence, future works are warranted to examine TRIB2-CDC25C interaction in the context of developing thymocytes and in T-cell acute lymphoblastic leukaemia, the malignant counterpart.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The long-standing Acid Growth Theory of plant cell elongation posits that auxin promotes cell elongation by stimulating cell wall acidification and thus expansin action. To date, the paucity of pertinent genetic materials has precluded thorough analysis of the importance of this concept in roots. The recent isolation of mutants of the model grass species Brachypodium distachyon with dramatically enhanced root cell elongation due to increased cellular auxin levels has allowed us to address this question. We found that the primary transcriptomic effect associated with elevated steady state auxin concentration in elongating root cells is upregulation of cell wall remodeling factors, notably expansins, while plant hormone signaling pathways maintain remarkable homeostasis. These changes are specifically accompanied by reduced cell wall arabinogalactan complexity but not by increased proton excretion. On the contrary, we observed a tendency for decreased rather than increased proton extrusion from root elongation zones with higher cellular auxin levels. Moreover, similar to Brachypodium, root cell elongation is, in general, robustly buffered against external pH fluctuation in Arabidopsis thaliana However, forced acidification through artificial proton pump activation inhibits root cell elongation. Thus, the interplay between auxin, proton pump activation, and expansin action may be more flexible in roots than in shoots.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Renewable or sustainable energy (SE) sources have attracted the attention of many countries because the power generated is environmentally friendly, and the sources are not subject to the instability of price and availability. This dissertation presents new trends in the DC-AC converters (inverters) used in renewable energy sources, particularly for photovoltaic (PV) energy systems. A review of the existing technologies is performed for both single-phase and three-phase systems, and the pros and cons of the best candidates are investigated. In many modern energy conversion systems, a DC voltage, which is provided from a SE source or energy storage device, must be boosted and converted to an AC voltage with a fixed amplitude and frequency. A novel switching pattern based on the concept of the conventional space-vector pulse-width-modulated (SVPWM) technique is developed for single-stage, boost-inverters using the topology of current source inverters (CSI). The six main switching states, and two zeros, with three switches conducting at any given instant in conventional SVPWM techniques are modified herein into three charging states and six discharging states with only two switches conducting at any given instant. The charging states are necessary in order to boost the DC input voltage. It is demonstrated that the CSI topology in conjunction with the developed switching pattern is capable of providing the required residential AC voltage from a low DC voltage of one PV panel at its rated power for both linear and nonlinear loads. In a micro-grid, the active and reactive power control and consequently voltage regulation is one of the main requirements. Therefore, the capability of the single-stage boost-inverter in controlling the active power and providing the reactive power is investigated. It is demonstrated that the injected active and reactive power can be independently controlled through two modulation indices introduced in the proposed switching algorithm. The system is capable of injecting a desirable level of reactive power, while the maximum power point tracking (MPPT) dictates the desirable active power. The developed switching pattern is experimentally verified through a laboratory scaled three-phase 200W boost-inverter for both grid-connected and stand-alone cases and the results are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on previous research which shows parallelism between the saliva and blood lactate response during incremental exercise, we hypothesized that a "maximum salivary lactate steady state" (saliva-MLSS) might exist. Thus, the aim of the present investigation was to establish 1) which lower limit for the increase in salivary lactate concentration during a constant workload (i.e., from the 10th to the 20th min) test could be used to determine the saliva-MLSS and 2) if the exercise intensity corresponding to the saliva-MLSS is identical to that evoking the (blood) MLSS. Twelve male amateur athletes of mean (+/-SD) age 24+/-5 year were selected for the study. Based on the results of a previous maximal cycle ergometer test for lactate threshold (LT) determination, each subject performed consecutive constant workload tests of 20-min duration on separate days for MLSS determination, Blood and saliva (25 mu l) samples were collected at 0, 10, and 20 min during the tests for lactate determination. A Student's t-test for paired data demonstrated that a salivary lactate increase of 0.8 mM corresponded to the saliva-MLSS. At this value, indeed, no significant differences were observed between the mean (V) over dot O-2, and W values corresponding to the MLSS and the saliva-MLSS. In conclusion, the present findings indicate that 0.8 mM is the lower limit for the increase in saliva lactate concentration during a constant load test and thus is that which might be used as a reference to determine saliva-MLSS. Furthermore, saliva-MLSS might be used as an alternative to MLSS determination in blood samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityö tehtiin Kemira Chemicals Oy:n Kokkolan tehtaiden rehufosfaattitehtaalla. Työn tavoitteena oli uusien reseptiohjauksien suunnittelu ja käyttöönotto sekä tasaussäiliön pinnansäädön ja rakeistusrummun suhdesäädön suunnittelu. Käyttöhenkilöstön koulutus uuteen prosessinohjaukseen kuului myös osaksi diplomityötä. Uuden reseptiohjauksen avulla pyrittiin saamaan prosessin ohjaus havainnollisemmaksi ja ennustettavammaksi käyttäjille, yhdenmukaistamaan käyttäjien ajotapaa sekä suunnitella tuotereseptit vastaamaan paremmin todellista tuotantoa. Uusi reseptiohjaus mahdollistaa myös lajikekohtaisten parametrien käytön ja hyväksi havaittujen ajoreseptien tallennuksen. Tasaussäiliön pinnankorkeuden säädön tavoitteena on poistaa tuotantokatkokset, jotka johtuivat säiliön tyhjenemisestä tai täyttymisestä. Rakeistusrummun suhdesäädön tavoitteena on reaktoriliemen ja kuiva-ainesyöttöjen oikean suhteen säilyttäminen. Uuden reseptiohjauksen käyttöönoton jälkeen ajoreseptit ovat vastanneet todellista tuotantoa ja tuotantovauhti on jäänyt pysyvästi korkeammalle tasolle. Tasaussäiliön pinnansäätö toimii suunnitellulla tavalla ja on myös otettu käyttöön. Reaktoriliemen ja kuivasyöttöjen suhdesäätö on testattu käytännössä ja toimii halutulla tavalla. Suhdesäädön paremman toiminnan kannalta epätarkkoja toimilaitteita tulisi kuitenkin uusia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gaseous and particulate emissions from a residential pellet boiler and a stove are measured at a realistic 6-day operation sequence and during steady state operation. The aim is to characterize the emissions during each phase in order to identify when the major part of the emissions occur to enable actions for emission reduction where the savings can be highest. The characterized emissions comprised carbon monoxide (CO), nitrogen oxide (NO), total organic carbon (TOC) and particulate matter (PM 2.5). In this study, emissions were characterised by mass concentration and emissions during start-up and stop phases were also presented in accumulated mass. The influence of start-up and stop phases on the emissions, average emission factors for the boiler and stove were analysed using the measured data from a six-days test. The share of start-up and stop emissions are significant for CO and TOC contributing 95% and 89% respectively at the 20kW boiler and 82% and 89% respectively at the 12 kW stove. NO and particles emissions are shown to dominate during stationary operation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a mixed-integer linear programming model to solve the conductor size selection and reconductoring problem in radial distribution systems. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. The proposed model and a heuristic are used to obtain the Pareto front of the conductor size selection and reconductoring problem considering two different objective functions. The results of one test system and two real distribution systems are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. © 1969-2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a mixed-integer linear programming model to solve the problem of allocating voltage regulators and fixed or switched capacitors (VRCs) in radial distribution systems. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The results of one test system and one real distribution system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. An heuristic to obtain the Pareto front for the multiobjective VRCs allocation problem is also presented. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a mixed-integer linear programming approach to solving the problem of optimal type, size and allocation of distributed generators (DGs) in radial distribution systems. In the proposed formulation, (a) the steady-state operation of the radial distribution system, considering different load levels, is modeled through linear expressions; (b) different types of DGs are represented by their capability curves; (c) the short-circuit current capacity of the circuits is modeled through linear expressions; and (d) different topologies of the radial distribution system are considered. The objective function minimizes the annualized investment and operation costs. The use of a mixed-integer linear formulation guarantees convergence to optimality using existing optimization software. The results of one test system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique.© 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)