991 resultados para pressure drop
Resumo:
With the development of micro systems, there is an increasing demand for integrable porous materials. In addition to those conventional applications, such as filtration, wicking, and insulating, many new micro devices, including micro reactors, sensors, actuators, and optical components, can benefit from porous materials. Conventional porous materials, such as ceramics and polymers, however, cannot meet the challenges posed by micro systems, due to their incompatibility with standard micro-fabrication processes. In an effort to produce porous materials that can be used in micro systems, porous silicon (PS) generated by anodization of single crystalline silicon has been investigated. In this work, the PS formation process has been extensively studied and characterized as a function of substrate type, crystal orientation, doping concentration, current density and surfactant concentration and type. Anodization conditions have been optimized for producing very thick porous silicon layers with uniform pore size, and for obtaining ideal pore morphologies. Three different types of porous silicon materials: meso porous silicon, macro porous silicon with straight pores, and macro porous silicon with tortuous pores, have been successfully produced. Regular pore arrays with controllable pore size in the range of 2µm to 6µm have been demonstrated as well. Localized PS formation has been achieved by using oxide/nitride/polysilicon stack as masking materials, which can withstand anodization in hydrofluoric acid up to twenty hours. A special etching cell with electrolytic liquid backside contact along with two process flows has been developed to enable the fabrication of thick macro porous silicon membranes with though wafer pores. For device assembly, Si-Au and In-Au bonding technologies have been developed. Very low bonding temperature (~200 degrees C) and thick/soft bonding layers (~6µm) have been achieved by In-Au bondi ng technology, which is able to compensate the potentially rough surface on the porous silicon sample without introducing significant thermal stress. The application of the porous silicon material in micro systems has been demonstrated in a micro gas chromatograph system by two indispensable components: an integrated vapor source and an inlet filter, wherein porous silicon performs the basic functions of porous media: wicking and filtration. By utilizing a macro porous silicon wick, the calibration vapor source was able to produce a uniform and repeatable vapor generation for n-decane with less than a 0.1% variation in 9 hours, and less than a 0.5% variation in rate over 7 days. With engineered porous silicon membranes the inlet filter was able to show a depth filtration with nearly 100% collection efficiency for particles larger than 0.3µm in diameter, a low pressure-drop of 523Pa at 20sccm flow rate, and a filter capacity of 500µg/cm2.
Resumo:
The emissions, filtration and oxidation characteristics of a diesel oxidation catalyst (DOC) and a catalyzed particulate filter (CPF) in a Johnson Matthey catalyzed continuously regenerating trap (CCRT ®) were studied by using computational models. Experimental data needed to calibrate the models were obtained by characterization experiments with raw exhaust sampling from a Cummins ISM 2002 engine with variable geometry turbocharging (VGT) and programmed exhaust gas recirculation (EGR). The experiments were performed at 20, 40, 60 and 75% of full load (1120 Nm) at rated speed (2100 rpm), with and without the DOC upstream of the CPF. This was done to study the effect of temperature and CPF-inlet NO2 concentrations on particulate matter oxidation in the CCRT ®. A previously developed computational model was used to determine the kinetic parameters describing the oxidation characteristics of HCs, CO and NO in the DOC and the pressure drop across it. The model was calibrated at five temperatures in the range of 280 – 465° C, and exhaust volumetric flow rates of 0.447 – 0.843 act-m3/sec. The downstream HCs, CO and NO concentrations were predicted by the DOC model to within ±3 ppm. The HCs and CO oxidation kinetics in the temperature range of 280 - 465°C and an exhaust volumetric flow rate of 0.447 - 0.843 act-m3/sec can be represented by one ’apparent’ activation energy and pre-exponential factor. The NO oxidation kinetics in the same temperature and exhaust flow rate range can be represented by ’apparent’ activation energies and pre-exponential factors in two regimes. The DOC pressure drop was always predicted within 0.5 kPa by the model. The MTU 1-D 2-layer CPF model was enhanced in several ways to better model the performance of the CCRT ®. A model to simulate the oxidation of particulate inside the filter wall was developed. A particulate cake layer filtration model which describes particle filtration in terms of more fundamental parameters was developed and coupled to the wall oxidation model. To better model the particulate oxidation kinetics, a model to take into account the NO2 produced in the washcoat of the CPF was developed. The overall 1-D 2-layer model can be used to predict the pressure drop of the exhaust gas across the filter, the evolution of particulate mass inside the filter, the particulate mass oxidized, the filtration efficiency and the particle number distribution downstream of the CPF. The model was used to better understand the internal performance of the CCRT®, by determining the components of the total pressure drop across the filter, by classifying the total particulate matter in layer I, layer II, the filter wall, and by the means of oxidation i.e. by O2, NO2 entering the filter and by NO2 being produced in the filter. The CPF model was calibrated at four temperatures in the range of 280 – 465 °C, and exhaust volumetric flow rates of 0.447 – 0.843 act-m3/sec, in CPF-only and CCRT ® (DOC+CPF) configurations. The clean filter wall permeability was determined to be 2.00E-13 m2, which is in agreement with values in the literature for cordierite filters. The particulate packing density in the filter wall had values between 2.92 kg/m3 - 3.95 kg/m3 for all the loads. The mean pore size of the catalyst loaded filter wall was found to be 11.0 µm. The particulate cake packing densities and permeabilities, ranged from 131 kg/m3 - 134 kg/m3, and 0.42E-14 m2 and 2.00E-14 m2 respectively, and are in agreement with the Peclet number correlations in the literature. Particulate cake layer porosities determined from the particulate cake layer filtration model ranged between 0.841 and 0.814 and decreased with load, which is about 0.1 lower than experimental and more complex discrete particle simulations in the literature. The thickness of layer I was kept constant at 20 µm. The model kinetics in the CPF-only and CCRT ® configurations, showed that no ’catalyst effect’ with O2 was present. The kinetic parameters for the NO2-assisted oxidation of particulate in the CPF were determined from the simulation of transient temperature programmed oxidation data in the literature. It was determined that the thermal and NO2 kinetic parameters do not change with temperature, exhaust flow rate or NO2 concentrations. However, different kinetic parameters are used for particulate oxidation in the wall and on the wall. Model results showed that oxidation of particulate in the pores of the filter wall can cause disproportionate decreases in the filter pressure drop with respect to particulate mass. The wall oxidation model along with the particulate cake filtration model were developed to model the sudden and rapid decreases in pressure drop across the CPF. The particulate cake and wall filtration models result in higher particulate filtration efficiencies than with just the wall filtration model, with overall filtration efficiencies of 98-99% being predicted by the model. The pre-exponential factors for oxidation by NO2 did not change with temperature or NO2 concentrations because of the NO2 wall production model. In both CPF-only and CCRT ® configurations, the model showed NO2 and layer I to be the dominant means and dominant physical location of particulate oxidation respectively. However, at temperatures of 280 °C, NO2 is not a significant oxidizer of particulate matter, which is in agreement with studies in the literature. The model showed that 8.6 and 81.6% of the CPF-inlet particulate matter was oxidized after 5 hours at 20 and 75% load in CCRT® configuration. In CPF-only configuration at the same loads, the model showed that after 5 hours, 4.4 and 64.8% of the inlet particulate matter was oxidized. The increase in NO2 concentrations across the DOC contributes significantly to the oxidation of particulate in the CPF and is supplemented by the oxidation of NO to NO2 by the catalyst in the CPF, which increases the particulate oxidation rates. From the model, it was determined that the catalyst in the CPF modeslty increases the particulate oxidation rates in the range of 4.5 – 8.3% in the CCRT® configuration. Hence, the catalyst loading in the CPF of the CCRT® could possibly be reduced without significantly decreasing particulate oxidation rates leading to catalyst cost savings and better engine performance due to lower exhaust backpressures.
Resumo:
One of the original ocean-bottom time-lapse seismic studies was performed at the Teal South oil field in the Gulf of Mexico during the late 1990’s. This work reexamines some aspects of previous work using modern analysis techniques to provide improved quantitative interpretations. Using three-dimensional volume visualization of legacy data and the two phases of post-production time-lapse data, I provide additional insight into the fluid migration pathways and the pressure communication between different reservoirs, separated by faults. This work supports a conclusion from previous studies that production from one reservoir caused regional pressure decline that in turn resulted in liberation of gas from multiple surrounding unproduced reservoirs. I also provide an explanation for unusual time-lapse changes in amplitude-versus-offset (AVO) data related to the compaction of the producing reservoir which, in turn, changed an isotropic medium to an anisotropic medium. In the first part of this work, I examine regional changes in seismic response due to the production of oil and gas from one reservoir. The previous studies primarily used two post-production ocean-bottom surveys (Phase I and Phase II), and not the legacy streamer data, due to the unavailability of legacy prestack data and very different acquisition parameters. In order to incorporate the legacy data in the present study, all three poststack data sets were cross-equalized and examined using instantaneous amplitude and energy volumes. This approach appears quite effective and helps to suppress changes unrelated to production while emphasizing those large-amplitude changes that are related to production in this noisy (by current standards) suite of data. I examine the multiple data sets first by using the instantaneous amplitude and energy attributes, and then also examine specific apparent time-lapse changes through direct comparisons of seismic traces. In so doing, I identify time-delays that, when corrected for, indicate water encroachment at the base of the producing reservoir. I also identify specific sites of leakage from various unproduced reservoirs, the result of regional pressure blowdown as explained in previous studies; those earlier studies, however, were unable to identify direct evidence of fluid movement. Of particular interest is the identification of one site where oil apparently leaked from one reservoir into a “new” reservoir that did not originally contain oil, but was ideally suited as a trap for fluids leaking from the neighboring spill-point. With continued pressure drop, oil in the new reservoir increased as more oil entered into the reservoir and expanded, liberating gas from solution. Because of the limited volume available for oil and gas in that temporary trap, oil and gas also escaped from it into the surrounding formation. I also note that some of the reservoirs demonstrate time-lapse changes only in the “gas cap” and not in the oil zone, even though gas must be coming out of solution everywhere in the reservoir. This is explained by interplay between pore-fluid modulus reduction by gas saturation decrease and dry-frame modulus increase by frame stiffening. In the second part of this work, I examine various rock-physics models in an attempt to quantitatively account for frame-stiffening that results from reduced pore-fluid pressure in the producing reservoir, searching for a model that would predict the unusual AVO features observed in the time-lapse prestack and stacked data at Teal South. While several rock-physics models are successful at predicting the time-lapse response for initial production, most fail to match the observations for continued production between Phase I and Phase II. Because the reservoir was initially overpressured and unconsolidated, reservoir compaction was likely significant, and is probably accomplished largely by uniaxial strain in the vertical direction; this implies that an anisotropic model may be required. Using Walton’s model for anisotropic unconsolidated sand, I successfully model the time-lapse changes for all phases of production. This observation may be of interest for application to other unconsolidated overpressured reservoirs under production.
Resumo:
The dissipation of high heat flux from integrated circuit chips and the maintenance of acceptable junction temperatures in high powered electronics require advanced cooling technologies. One such technology is two-phase cooling in microchannels under confined flow boiling conditions. In macroscale flow boiling bubbles will nucleate on the channel walls, grow, and depart from the surface. In microscale flow boiling bubbles can fill the channel diameter before the liquid drag force has a chance to sweep them off the channel wall. As a confined bubble elongates in a microchannel, it traps thin liquid films between the heated wall and the vapor core that are subject to large temperature gradients. The thin films evaporate rapidly, sometimes faster than the incoming mass flux can replenish bulk fluid in the microchannel. When the local vapor pressure spike exceeds the inlet pressure, it forces the upstream interface to travel back into the inlet plenum and create flow boiling instabilities. Flow boiling instabilities reduce the temperature at which critical heat flux occurs and create channel dryout. Dryout causes high surface temperatures that can destroy the electronic circuits that use two-phase micro heat exchangers for cooling. Flow boiling instability is characterized by periodic oscillation of flow regimes which induce oscillations in fluid temperature, wall temperatures, pressure drop, and mass flux. When nanofluids are used in flow boiling, the nanoparticles become deposited on the heated surface and change its thermal conductivity, roughness, capillarity, wettability, and nucleation site density. It also affects heat transfer by changing bubble departure diameter, bubble departure frequency, and the evaporation of the micro and macrolayer beneath the growing bubbles. Flow boiling was investigated in this study using degassed, deionized water, and 0.001 vol% aluminum oxide nanofluids in a single rectangular brass microchannel with a hydraulic diameter of 229 µm for one inlet fluid temperature of 63°C and two constant flow rates of 0.41 ml/min and 0.82 ml/min. The power input was adjusted for two average surface temperatures of 103°C and 119°C at each flow rate. High speed images were taken periodically for water and nanofluid flow boiling after durations of 25, 75, and 125 minutes from the start of flow. The change in regime timing revealed the effect of nanoparticle suspension and deposition on the Onset of Nucelate Boiling (ONB) and the Onset of Bubble Elongation (OBE). Cycle duration and bubble frequencies are reported for different nanofluid flow boiling durations. The addition of nanoparticles was found to stabilize bubble nucleation and growth and limit the recession rate of the upstream and downstream interfaces, mitigating the spreading of dry spots and elongating the thin film regions to increase thin film evaporation.
Resumo:
This honors thesis research project was the study and development of a compact separation device for the oil and gas industry involving a multiphase cylindrical screen filter. Cylindrical screens can be used for solids removal in multiphase flow in upstream oil and gas applications. This study focused on cylindrical wire-wrap screen test unit design and performance characterization to determine volumetric flow rate and pressure drop correlations. The project goals were met with research, test unit design, CFD modeling, calculations, and physical testing. The comprehensive testing will take place during the summer of 2013 and is planned to consist of building the designed flowloop and housing and using high capacity pumps to achieve higher flow rates. Multiphase testing will be performed with water, air, and sand particles and flow and pressure effects will be evaluated for solids filtering over time.
Resumo:
Renal replacement therapy by hemodialysis requires a permanent vascular access. Implantable ports offer a potential alternative to standard vascular access strategies although their development is limited both in number and extent. We explored the fluid dynamics within two new percutaneous bone-anchored dialysis port prototypes, both by in vitro experiments and computer simulation. The new port is to be fixed to bone and allows the connection of a dialysis machine to a central venous catheter via a built-in valve. We found that the pressure drop induced by the two ports was between 20 and 50 mmHg at 500 ml/min, which is comparable with commercial catheter connectors (15–80 mmHg). We observed the formation of vortices in both geometries, and a shear rate in the physiological range (<10,000s-1), which is lower than maximal shear rates reported in commercial catheters (up to 13,000s-1). A difference in surface shear rate of 15% between the two ports was obtained.
Resumo:
Indoor and ambient air organic pollutants have been gaining attention because they have been measured at levels with possible health effects. Studies have shown that most airborne polychlorinated biphenyls (PCBs), pesticides and many polycyclic aromatic hydrocarbons (PAHs) are present in the free vapor state. The purpose of this research was to extend recent investigative work with polyurethane foam (PUF) as a collection medium for semivolatile compounds. Open-porous flexible PUFs with different chemical makeup and physical properties were evaluated as to their collection affinities/efficiencies for various classes of compounds and the degree of sample recovery. Filtered air samples were pulled through plugs of PUF spiked with various semivolatiles under different simulated environmental conditions (temperature and humidity), and sampling parameters (flow rate and sample volume) in order to measure their effects on sample breakthrough volume (V(,B)). PUF was also evaluated in the passive mode using organo-phosphorus pesticides. Another major goal was to improve the overall analytical methodology; PUF is inexpensive, easy to handle in the field and has excellent airflow characteristics (low pressure drop). It was confirmed that the PUF collection apparatus behaves as if it were a gas-solid chromatographic system, in that, (V(,B)) was related to temperature and sample volume. Breakthrough volumes were essentially the same using both polyether and polyester type PUF. Also, little change was observed in the V(,B)s after coating PUF with common chromatographic liquid phases. Open cell (reticulated) foams gave better recoveries than closed cell foams. There was a slight increase in (V(,B)) with an increase in the number of cells/pores per inch. The high-density polyester PUF was found to be an excellent passive and active collection adsorbent. Good recoveries could be obtained using just solvent elution. A gas chromatograph equipped with a photoionization detector gave excellent sensitivities and selectivities for the various classes of compounds investigated. ^
Resumo:
The heterogeneous incoming heat flux in solar parabolic trough absorber tubes generates huge temperature difference in each pipe section. Helical internal fins can reduce this effect, homogenising the temperature profile and reducing thermal stress with the drawback of increasing pressure drop. Another effect is the decreasing of the outer surface temperature and thermal losses, improving the thermal efficiency of the collector. The application of internal finned tubes for the design of parabolic trough collectors is analysed with computational fluid dynamics tools. Our numerical approach has been qualified with the computational estimation of reported experimental data regarding phenomena involved in finned tube applications and solar irradiation of parabolic trough collector. The application of finned tubes to the design of parabolic trough collectors must take into account issues as the pressure losses, thermal losses and thermo-mechanical stress, and thermal fatigue. Our analysis shows an improvement potential in parabolic trough solar plants efficiency by the application of internal finned tubes.
Resumo:
The objective of this work is to analyze the local hem odynamic changes caused in a coronary bifurcation by three different stenting techniques: simple stenting of the main vessel, simple stenting of the main vessel with kissing balloon in the side branch and culotte. To carry out this study an idealized geometry of a coronary bifurcation is used, and two bifurcation angles, 45º and 90º, are chosen as representative of the wide variety of re al configurations. In order to quantify the influence of the stenting technique on the local blood flow, both numeri- cal simulations and experimental measurements are performed. First, steady simulations are carried out with the commercial code ANSYS-Fluent, and then, experimental measurements with PIV (Particle Image Velocimetry) obtained in the laboratory are used to validate the numerical simulation. The steady computational simulations show a good overall agreement with the experimental data. Second, pulsatile flow is considered to take into account the tran- sient effects. The time averaged wall shear stress, scillatory shear index and pressure drop obtained numerically are used to compare the behavior of the stenting techniques.
Resumo:
En esta tesis se investiga de forma experimental el transporte pasivo de magnitudes físicas en micro-sistemas con carácter de inmediata aplicación industrial, usando métodos innovadores para mejorar la eficiencia de los mismos optimizando parámetros críticos del diseño o encontrar nuevos destinos de posible aplicación. Parte de los resultados obtenidos en estos experimentos han sido publicados en revistas con un índice de impacto tal que pertenecen al primer cuarto del JCR. Primero de todo se ha analizado el efecto que produce en un intercambiador de calor basado en micro-canales el hecho de dejar un espacio entre canales y tapa superior para la interconexión de los mismos. Esto genera efectos tridimensionales que mejoran la exracción de calor del intercambiador y reducen la caída de presión que aparece por el transcurso del fluido a través de los micro-canales, lo que tiene un gran impacto en la potencia que ha de suministrar la bomba de refrigerante. Se ha analizado también la mejora producida en términos de calor disipado de un micro-procesador refrigerado con un ampliamente usado plato de aletas al implementar en éste una cámara de vapor que almacena un fluido bifásico. Se ha desarrollado de forma paralela un modelo numérico para optimizar las nuevas dimensiones del plato de aletas modificado compatibles con una serie de requerimientos de diseño en el que tanto las dimensiones como el peso juegan un papel esencial. Por otro lado, se han estudiado los fenomenos fluido-dinámicos que aparecen aguas abajo de un cuerpo romo en el seno de un fluido fluyendo por un canal con una alta relación de bloqueo. Los resultados de este estudio confirman, de forma experimental, la existencia de un régimen intermedio, caracterizado por el desarrollo de una burbuja de recirculación oscilante entre los regímenes, bien diferenciados, de burbuja de recirculación estacionaria y calle de torbellinos de Karman, como función del número de Reynolds del flujo incidente. Para la obtención, análisis y post-proceso de los datos, se ha contado con la ayuda de un sistema de Velocimetría por Imágenes de Partículas (PIV). Finalmente y como adición a este último punto, se ha estudiado las vibraciones de un cuerpo romo producidas por el desprendimiento de torbellinos en un canal de alta relación de bloqueo con la base obtenida del estudio anterior. El prisma se mueve con un movimiento armónico simple para un intervalo de números de Reynolds y este movimiento se transforma en vibración alrededor de su eje a partir de un ciero número de Reynolds. En relación al fluido, el régimen de desprendimiento de torbellinos se alcanza a menores números de Reynolds que en el caso de tener el cuerpo romo fijo. Uniendo estos dos registros de movimientos y variando la relación de masas entre prisma y fluido se obtiene un mapa con diferentes estados globales del sistema. Esto no solo tiene aplicación como método para promover el mezclado sino también como método para obtener energía a partir del movimiento del cuerpo en el seno del fluido. Abstract In this thesis, experimental research focused on passive scalar transport is performed in micro-systems with marked sense of industrial application, using innovative methods in order to obtain better performances optimizing critical design parameters or finding new utilities. Part of the results obtained in these experiments have been published into high impact factor journals belonged to the first quarter of the Journal Citation Reports (JCR). First of all the effect of tip clearance in a micro-channel based heat sink is analyzed. Leaving a gap between channels and top cover, letting the channels communicate each other causes three-dimensional effects which improve the heat transfer between fluid and heat sink and also reducing the pressure drop caused by the fluid passing through the micro-channels which has a great impact on the total cooling pumping power needed. It is also analyzed the enhancement produced in terms of dissipated heat in a micro-processor cooling system by improving the predominantly used fin plate with a vapour chamber based heat spreader which contains a two-phase fluid inside. It has also been developed at the same time a numerical model to optimize the new fin plate dimensions compatible with a series of design requirements in which both size and wight plays a very restrictive role. On the other hand, fluid-dynamics phenomena that appears downstream of a bluff body in the bosom of a fluid flow with high blockage ratio has been studied. This research experimentally confirms the existence of an intermediate regime characterized by an oscillating closed recirculation bubble intermediate regime between the steady closed recirculation bubble regime and the vortex shedding regime (Karman street like regime) as a function of the incoming flow Reynolds number. A particle image velocimetry technique (PIV) has been used in order to obtain, analyze and post-process the fluid-dynamic data. Finally and as an addition to the last point, a study on the vortexinduced vibrations (VIV) of a bluff body inside a high blockage ratio channel has been carried out taking advantage of the results obtained with the fixed square prism. The prism moves with simple harmonic motion for a Reynolds number interval and this movement becomes vibrational around its axial axis after overcoming at definite Reynolds number. Regarding the fluid, vortex shedding regime is reached at Reynolds numbers lower than the previous critical ones. Merging both movement spectra and varying the square prism to fluid mass ratio, a map with different global states is reached. This is not only applicable as a mixing enhancement technique but as an energy harvesting method.
Resumo:
Las enfermedades arteriales vienen presididas por la aterosclerosis, que es un proceso crónico de degeneración, que evoluciona hacia la obstrucción de la luz arterial. La pared de la arteria se engrosa debido al depósito de elementos grasos tales como el colesterol. Los stents intraluminales son diminutas estructuras tubulares autoexpandibles de malla de metal, que se colocan dentro de la arteria coronaria después de una angioplastia con balón para prevenir el cierre de dicha arteria. A pesar de estar diseñados para ser compatibles con el tejido humano, a menudo se da una reacción en cadena de consecuencias indeseables. La reestenosis intra-stent es un problema creciente debido al importante incremento que se ha producido en la utilización del stent intracoronario como forma de revascularización percutánea. Se habla de una incidencia global del 28%, siendo la causa principal de su aparición la proliferación neointimal a través de una compleja cascada de sucesos que pueden tardar meses en desarrollarse. Una de las reacciones más importantes es la trombosis o la formación de una fina capa de coágulo como respuesta a la presencia de un material extraño. Este proceso es multifactorial, y en él intervienen la regresión de la pared como consecuencia del estiramiento previo, la denudación endotelial, lo que permite la agregación plaquetaria, la proliferación neointimal, lo que facilita a los receptores de membrana desencadenar un proceso de agregación posterior y, por último, el remodelado negativo inadecuado de la pared, lo que produce pérdida de luz arterial. Se ha observado frecuentemente que el depósito de ateroma en la pared arterial está relacionado con el valor de los esfuerzos cortantes en la misma. Hay mayores probabilidades de engrosamiento de la pared en las zonas donde son bajos los esfuerzos cortantes, quizá por el mayor tiempo de residencia de las partículas circulantes por el torrente sanguíneo. Si nos centramos en la afirmación anterior, el siguiente paso sería buscar las zonas susceptibles de presentar un valor bajo de dichos esfuerzos. Las zonas potencialmente peligrosas son los codos y bifurcaciones, entre otras. Nos hemos centrado en una bifurcación coronaria, ya que los patrones de flujo que se suelen presentar, tales como recirculación y desprendimiento de vórtices están íntimamente relacionados con las técnicas de implantación de stents en esta zona. Proyectamos nuestros esfuerzos en el estudio de dos técnicas de implante, utilizando un único stent y una tercera a través de una configuración de culotte con el uso de dos stents. El primer caso trata de una bifurcación con un único stent en la rama principal cuyos struts cierran el orificio lateral que da salida a la rama secundaria de la bifurcación, es decir sería un stent sin orificio. El segundo consiste en un único stent también, pero con la diferencia de que éste presenta un orificio de comunicación con la rama lateral. Todas estas técnicas se aplicaron a bifurcaciones de 45º y de 90º. Introdujimos las geometrías -una vez confeccionadas con el código comercial Gambit- en el programa Ansys-Fluent contemplando régimen estacionario. Los resultados obtenidos fueron cotejados con los experimentales, que se realizaron paralelamente, con el fin de corroborarlos. Una vez validados, el estudio computacional ya contó con la fiabilidad suficiente como para abordar el régimen no estacionario, tanto en la versión de reposo como en la de ejercicio –hiperemia- El comportamiento reológico de la sangre para régimen no estacionario en estado de reposo es otra de las tareas abordadas, realizando una comparativa de los modelos Newtoniano, Carreau y Ley de Potencias. Finalmente, en una última etapa, debido a la reciente incursión de los stents diseñados específicamente frente a los convencionales, se aborda el comportamiento hemodinámico de los mismos. Concretamente, se comparó el patrón de flujo en un modelo de bifurcación coronaria con los nuevos stents (Stentys) y los convencionales. Se estudiaron cuatro modelos, a saber, stent simple en la rama principal, stent simple en la rama secundaria, culotte desplegando el primer stent en la rama principal y culotte desplegando el primer stent en la rama secundaria. La bifurcación estudiada presenta un ángulo de apertura de 45º y la relación de diámetros de las ramas hija se ajustaron de acuerdo a la ley de Finet. Se recogieron resultados experimentales en el laboratorio y se corrieron simulaciones numéricas con Ansys Fluent paralelamente. Las magnitudes que se tuvieron en cuenta con el fin de ubicar las regiones potencialmente ateroscleróticas fueron los esfuerzos cortantes, vorticidad y caída de presión. ABSTRACT Nowadays, restenosis after percutaneous dilation is the major drawback of coronary angioplasty. It represents a special form of atherosclerosis due to the healing process secondary to extensive vessel trauma induced after intracoronary balloon inflation. The use of coronary stents may decrease the incidence of this phenomenon. Unfortunately, intra-stent restenosis still occurs in 20-30% of the cases following the stent implantation. Most experiments suggest a correlation between low wall shear stress and wall thickness. The preferential locations for the atherosclerotic plaque are bifurcations. The objective of this work is to analyze the local hemodynamic changes caused in a coronary bifurcation by three different stenting techniques: simple stenting of the main vessel, simple stenting of the main vessel with kissing balloon in the side branch and culotte. To carry out this study an idealized geometry of a coronary bifurcation is used, and two bifurcation angles, 45º and 90º, are chosen as representative of the wide variety of real configurations. Both numerical simulations and experimental measurements are performed. First, steady simulations are carried out with the commercial code Ansys-Fluent, then, experimental measurements with PIV (Particle Image Velocimetry), obtained in the laboratory, are used to validate the numerical simulations. The steady computational simulations show a good overall agreement with the experimental data. Then, pulsatile flow is considered to take into account the transient effects. The time averaged wall shear stress, oscillatory shear index and pressure drop obtained numerically are used to compare the behavior of the stenting techniques. In a second step, the rheologic behavior of blood was considered comparing Newtonian, Carreau and Power Law models. Finally, as a result of previous investigations with conventional stents and after the recent emergence of several devices specifically designed for coronary bifurcations angioplasty, the hemodynamic performance of these new devices (Stentys) was compared to conventional ones and techniques in a coronary bifurcation model. Four different stenting techniques: simple stenting of the main vessel, simple stenting of the side vessel, culotte deploying the first stent in the main vessel and culotte deploying the first stent in the side vessel have been considered. To carry out this study an idealized geometry of a coronary bifurcation is used. A 45 degrees bifurcation angle is considered and the daughter branches diameters are obtained according to the Finet law. Both experiments in the laboratory and numerical simulations were used , focusing on important factors for the atherosclerosis development, like the wall shear stress, the oscillation shear index, the pressure loss and the vorticity.
Resumo:
Escoamentos bifásicos estão presentes em diversos processos naturais e industriais, como na indústria de petróleo. Podem apresentar-se em diferentes configurações topológicas, ou, padrões de escoamento, entre eles o escoamento estratificado ondulado e o estratificado com mistura na interface. Os escoamentos bifásicos estratificados óleo-água têm sido utilizados como uma forma conveniente de evitar a formação de emulsões de água em óleo em oleodutos e possuem uma ocorrência comum em poços de petróleo direcionais. Quando a onda interfacial ultrapassa determinado limite geométrico e cinemático, surge o fenômeno do entranhamento de gotas, representado por misturas entre as fases junto à interface que promovem um aumento na queda de pressão. Modelos têm sido apresentados pela literatura na tentativa de descrever o fenômeno do entranhamento de gotas. Neste trabalho é apresentada uma nova proposta de modelagem matemática unidimensional para o entranhamento de gotas com o objetivo de melhorar a previsão dos parâmetros envolvidos, em especial, da fração volumétrica de óleo e da queda de pressão bifásica. Também foi utilizada simulação numérica computacional, CFD (Computational Fluid Dynamics), com o uso de software comercial para obtenção dos valores dos parâmetros do escoamento estratificado ondulado óleo-água (fração volumétrica de óleo, queda de pressão, amplitude e comprimento da onda interfacial). Os resultados da modelagem fenomenológica para entranhamento e os de CFD foram comparados com bancos de dados experimentais. Os resultados em CFD mostram concordância com os resultados experimentais, tanto na análise qualitativa das propriedades geométricas das ondas interfaciais, quanto na comparação direta com os dados para fração volumétrica e queda de pressão. Os resultados numéricos da modelagem fenomenológica para fatores de entranhamento apresentam boa concordância com dados da literatura.
Resumo:
Esta pesquisa visa a análise da contribuição de cinco variáveis de entrada e a otimização do desempenho termo-hidráulico de trocadores de calor com venezianas combinados com geradores de vórtices delta-winglets. O desempenho termohidráulico de duas geometrias distintas, aqui nomeadas por GEO1 e GEO2, foram avaliadas. Smoothing Spline ANOVA foi usado para avaliar a contribuição dos parâmetros de entrada na transferência de calor e perda de carga. Considerando aplicação automotiva, foram investigados números de Reynolds iguais a 120 e 240, baseados no diâmetro hidráulico. Os resultados indicaram que o ângulo de venezianas é o maior contribuidor para o aumento do fator de atrito para GEO1 e GEO2, para ambos os números de Reynolds. Para o número de Reynolds menor, o parâmetro mais importante em termos de transferência de calor foi o ângulo das venezianas para ambas as geometrias. Para o número de Reynolds maior, o ângulo de ataque dos geradores de vórtices posicionados na primeira fileira é o maior contribuidor para a tranfesferência de calor, no caso da geometria GEO1, enquanto que o ângulo de ataque dos geradores de vórtices na primeira fileira foi tão importante quanto os ângulos das venezianas para a geometria GEO2. Embora as geometrias analisadas possam ser consideradas como técnicas compostas de intensificação da transferência de calor, não foram observadas interações relevantes entre ângulo de venezianas e parâmetros dos geradores de vórtices. O processo de otimização usa NSGA-II (Non-Dominated Sorting Genetic Algorithm) combinado com redes neurais artificiais. Os resultados mostraram que a adição dos geradores de vórtices em GEO1 aumentaram a transferência de calor em 21% e 23% com aumentos na perda de carga iguais a 24,66% e 36,67% para o menor e maior números de Reynolds, respectivamente. Para GEO2, a transferência de calor aumentou 13% e 15% com aumento na perda de carga de 20,33% e 23,70%, para o menor e maior número de Reynolds, respectivamente. As soluções otimizadas para o fator de Colburn mostraram que a transferência de calor atrás da primeira e da segunda fileiras de geradores de vórtices tem a mesma ordem de magnitude para ambos os números de Reynolds. Os padrões de escoamento e as características de transferência de calor das soluções otimizadas apresentaram comportamentos vi particulares, diferentemente daqueles encontrados quando as duas técnicas de intensificação de transferência de calor são aplicadas separadamente.
Resumo:
The active phase Ce0.5Pr0.5O2 has been loaded on commercial substrates (SiC DPF and cordierite honeycomb monolith) to perform DPF regeneration experiments in the exhaust of a diesel engine. Also, a powder sample has been prepared to carry out soot combustion experiments at laboratory. Experiments performed in the real diesel exhaust demonstrated the catalytic activity of the Ce–Pr mixed oxide for the combustion of soot, lowering the DPF regeneration temperature with regard to a counterpart catalyst-free DPF. The temperature for active regeneration of the Ce0.5Pr0.5O2-containing DPF when the soot content is low is in the range of 500–550 °C. When the Ce0.5Pr0.5O2-containing DPF is saturated with a high amount of soot, pressure drop and soot load at the filter reach equilibrium at around 360 °C under steady state engine operation due to passive regeneration. The uncoated DPF reached this equilibrium at around 440 °C. Comparing results at real exhaust with those at laboratory allow concluding that the Ce0.5Pr0.5O2-catalysed soot combustion in the real exhaust is not based on the NO2-assisted mechanism but is most likely occurring by the active oxygen-based mechanism.
Resumo:
An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers