905 resultados para pitch controller
Resumo:
In a Text-to-Speech system based on time-domain techniques that employ pitch-synchronous manipulation of the speech waveforms, one of the most important issues that affect the output quality is the way the analysis points of the speech signal are estimated and the actual points, i.e. the analysis pitchmarks. In this paper we present our methodology for calculating the pitchmarks of a speech waveform, a pitchmark detection algorithm, which after thorough experimentation and in comparison with other algorithms, proves to behave better with our TD-PSOLA-based Text-to-Speech synthesizer (Time- Domain Pitch-Synchronous Overlap Add Text to Speech System).
Resumo:
Novel statistical models are proposed and developed in this paper for automated multiple-pitch estimation problems. Point estimates of the parameters of partial frequencies of a musical note are modeled as realizations from a non-homogeneous Poisson process defined on the frequency axis. When several notes are combined, the processes for the individual notes combine to give a new Poisson process whose likelihood is easy to compute. This model avoids the data-association step of linking the harmonics of each note with the corresponding partials and is ideal for efficient Bayesian inference of unknown multiple fundamental frequencies in a signal. © 2011 IEEE.
Resumo:
We demonstrate a fast-switching (sub-millisecond) phase grating based upon a polymer stabilized short-pitch chiral nematic liquid crystal that is electrically addressed using in-plane electric fields. The combination of the short-pitch and the polymer stabilization enables the diffraction pattern to be switched “on” and “off” reversibly in 600 µs. Results are presented on the far-field diffraction pattern along with the intensity of the diffraction orders as a function of the applied electric field and the response times.
Resumo:
Two control algorithms have been developed for a minimally invasive axial-flow ventricular assist device (VAD) for placement in the descending aorta. The purpose of the device is to offload the left ventricle and to augment lower body perfusion in patients with moderate congestive heart failure. The VAD consists of an intra-aortic impeller with a built-in permanent magnet rotor and an extra-aortic stator. The control algorithms, which use pressure readings upstream and downstream of the VAD to determine the pump status, have been tested in a mock circulatory system under two conditions, namely with or without afterload sensitivity. The results give an insight into controller design for an intra-aortic blood pump working in series with the heart.