993 resultados para perfusion cérébrale


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We hypothesized that platelet-activating factor (PAF), a potent inflammatory mediator, could induce gas exchange abnormalities in normal humans. To this end, the effect of aerosolized PAF (2 mg/ml solution; 24 micrograms) on ventilation-perfusion (VA/Q) relationships, hemodynamics, and resistance of the respiratory system was studied in 14 healthy, nonatopic, and nonsmoking individuals (23 +/- 1 [SEM]yr) before and at 2, 4, 6, 8, 15, and 45 min after inhalation, and compared to that of inhaled lyso-PAF in 10 other healthy individuals (24 +/- 2 yr). PAF induced, compared to lyso-PAF, immediate leukopenia (P < 0.001) followed by a rebound leukocytosis (P < 0.002), increased minute ventilation (P < 0.05) and resistance of the respiratory system (P < 0.01), and decreased systemic arterial pressure (P < 0.05). Similarly, compared to lyso-PAF, PaO2 showed a trend to fall (by 12.2 +/- 4.3 mmHg, mean +/- SEM maximum change from baseline), and arterial-alveolar O2 gradient increased (by 16.7 +/- 4.3 mmHg) (P < 0.02) after PAF, because of VA/Q mismatch: the dispersion of pulmonary blood flow and that of ventilation increased by 0.45 +/- 0.1 (P < 0.01) and 0.29 +/- 0.1 (P < 0.04), respectively. We conclude that in normal subjects, inhaled PAF results in considerable immediate VA/Q inequality and gas exchange impairment. These results reinforce the notion that PAF may play a major role as a mediator of inflammation in the human lung.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim:Isolated limb perfusion (ILP) is a technique consisting in administrating doses of chemotherapy up to 20 times higher than via systemic route in a limb affected by melanoma or sarcoma to maximise tumour reduction. ILP is performed in <50 centres worldwide and leads to partial or complete response, however without effect on overall survival. As an alternative to amputation, it improves patient quality of life. We report our >10-year single centre experience on the role of nuclear medicine in ILP. Material and method:From 2000 to 2012, we performed 77 ILP (45 women, 32 men; aged 62±16 years) for 49 melanoma (64%), 25 sarcoma (32%) and 3 others tumors (2 desmoid tumours and 1 aggressive fibromatosis) (3%). The affected limb vascularisation is isolated from the systemic circulation (SYS) using extracorporeal circulation, and chemotherapy (usually TNF and Melphalan) is administered. Peroperatively, limb isolation and eventual leakage from ILP to SYS are monitored by continuous measurement using a gamma-probe placed over the heart (150MBq of 99mTc-human serum albumin in ILP and 4MBq in SYS). The maximum acceptable leakage to the systemic circulation is 10% (maximum tolerated systemic TNF dose). Results:In total, 47 patients (61%) had positive leaks from the ILP to SYS of 4.1±14.5% (median 1% interquartile range 0.4% to 3.2%, range 0 to 100%) and 30 patients (39%) had negative leaks from the SYS to ILP of -0.9±1.2% (median -0.5%, interquartile range -0.8% to -0.2%, range -4.8% to -0.1%). In only 2 patients (2.6%), leaks >10% were observed leading to interrupting ILP. Conclusion:Nuclear Medicine has a crucial role for the safety and quality of ILP in monitoring leakage peroperatively and help deciding whether the procedure should be interrupted to minimize systemic toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To illustrate the evolution of brain perfusion-weighted magnetic resonance imaging (PWI-MRI) in severe neonatal hypoxic-ischemic (HI) encephalopathy, and its possible relation to further neurodevelopmental outcome. MATERIALS AND METHODS: Two term neonates with HI encephalopathy underwent an early and a late MRI, including PWI. They were followed until eight months of age. A total of three "normal controls" were also included. Perfusion maps were obtained, and relative cerebral blood flow (rCBF) and cerebral blood volume (rCBV) values were measured. RESULTS: Compared to normal neonates, a hyperperfusion (increased rCBF and rCBV) was present on early scans in the whole brain. On late scans, hyperperfusion persisted in cortical gray matter (normalization of rCBF and rCBV ratios in white matter and basal ganglia, but not in cortical gray matter). Diffusion-weighted imaging (DWI) was normalized, and extensive lesions became visible on T2-weighted images. Both patients displayed very abnormal outcome: Patient 2 with the more abnormal early and late hyperperfusion being the worst. CONCLUSION: PWI in HI encephalopathy did not have the same temporal evolution as DWI, and remained abnormal for more than one week after injury. This could be a marker of an ongoing mechanism underlying severe neonatal HI encephalopathy. Evolution of PWI might help to predict further neurodevelopmental outcome.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Several software packages (SWP) and models have been released for quantification of myocardial perfusion (MP). Although they all are validated against something, the question remains how well their values agree. The present analysis focused on cross-comparison of three SWP for MP quantification of 13N-ammonia PET studies. Materials & Methods. 48 rest and stress MP 13N-ammonia PET studies of hypertrophic cardiomyopathy (HCM) patients (Sciagrà et al., 2009) were analysed with three SW packages - Carimas, PMOD, and FlowQuant - by three observers blinded to the results of each other. All SWP implement the one-tissue-compartment model (1TCM, DeGrado et al. 1996), and first two - the two-tissue-compartment model (2TCM, Hutchins et al. 1990) as well. Linear mixed model for the repeated measures was fitted to the data. Where appropriate we used Bland-Altman plots as well. The reproducibility was assessed on global, regional and segmental levels. Intraclass correlation coefficients (ICC), differences between the SWPs and between models were obtained. ICC≥0.75 indicated excellent reproducibility, 0.4≤ICC<0.75 indicated fair to good reproducibility, ICC<0.4 - poor reproducibility (Rosner, 2010). Results. When 1TCM MP values were compared, the SW agreement on global and regional levels was excellent, except for Carimas vs. PMOD at RCA: ICC=0.715 and for PMOD vs. FlowQuant at LCX:ICC=0.745 which were good. In segmental analysis in five segments: 7,12,13, 16, and 17 the agreement between all SWP was excellent; in the remaining 12 segments the agreement varied between the compared SWP. Carimas showed excellent agreement with FlowQuant in 13 segments and good in four - 1, 5, 6, 11: 0.687≤ICCs≤0.73; Carimas had excellent agreement with PMOD in 11 segments, good in five_4, 9, 10, 14, 15: 0.682≤ICCs≤0.737, and poor in segment 3: ICC=0.341. PMOD had excellent agreement with FlowQuant in eight segments and substantial-to-good in nine_1, 2, 3, 5, 6,8-11: 0.585≤ICCs≤0.738. Agreement between Carimas and PMOD for 2TCM was good at a global level: ICC=0.745, excellent at LCX (0.780) and RCA (0.774), good at LAD (0.662); agreement was excellent for ten segments, fair-to-substantial for segments 2, 3, 8, 14, 15 (0.431≤ICCs≤0.681), poor for segments 4 (0.384) and 17 (0.278). Conclusions. The three SWP used by different operators to analyse 13N-ammonia PET MP studies provide results that agree well at a global level, regional levels, and mostly well even at a segmental level. Agreement is better for 1TCM. Poor agreement at segments 4 and 17 for 2TCM needs further clarification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: It is unknown whether cerebral perfusion in geriatric and younger patients under general anaesthesia differs. Methods: We compared 2 groups of patients undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Group 1: 18-40 yrs (n = 20), Group 2: >65 yrs (n = 37). Cerebral perfusion was investigated with transcranial Doppler and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Data are shown as mean } SD. Results: MAP (86 } 9.6 vs 79 } 10.9 mm Hg, p = 0.02), end-tidal concentration of sevoflurane (1.9 } 0.3 vs 1.6 } 0.3%, p <0.01), and the cerebral tissue oxygenation index measured by NIRS (72 } 4 vs 68 } 5%, p = 0.01), were significantly lower in Group 2. The end-tidal concentration of O2 was significantly higher in Group 2 (46 } 4 vs 48 } 4% p = 0.04). There were no significant differences between Group 1 and 2 for cerebral blood flow velocity (41 } 10 vs 43 } 18 cm/s), end tidal CO2 (4.7 } 0.3 vs 4.6 } 0.3 kPa) and cerebrovascular autoregulation (Mx 0.42 } 0.2 vs 0.48 } 0.2). In Group 1 35% and in Group 2 43% of the patients had an index of autoregulation suggesting disturbed cerebrovascular autoregulation (p = n.s.). Conclusions: In elderly patients under general anaesthesia with sevoflurane the cerebral tissue oxygenation index was significantly lower than in younger patients despite higher end-tidal oxygen concentrations. Our data suggest subtle differences in cerebral perfusion between geriatric and younger

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances have allowed the development of new physical techniques in neurology and psychiatry, such as Transcranial Magnetic Stimulation (TMS), Vagus Nerve Stimulation (VNS), and Deep Brain Stimulation (DBS). These techniques are already recognized as therapeutic approaches in several late stage refractory neurological disorders (Parkinson's disease, tremor, epilepsy), and currently investigated in psychiatric conditions, refractory to medical treatment (obsessive-compulsive disorder, resistant major depression). In Paralell, these new techniques offer a new window to understand the neurobiology of human behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the past decade, PET and PET/CT have been widely studied for myocardial perfusion imaging. Several studies demonstrated the incremental value of PET for the diagnostic and prognostic assessment of patients with coronary artery disease. Moreover, PET allows for non-invasively quantifying myocardial blood flow and myocardial flow reserve, that both are recognized as surrogate marker of cardiac event free survival. By enabling the exploration of epicardial disease and the microvasculature, PET constitutes a unique tool to study pathophysiogical mechanisms leading to atherosclerosis genesis. The recent emergence of high-tech hybrid machines may even provide further incremental information about coronary function and morphology. By taking the best of each modality, a better assessment of patients with coronary artery disease is expected. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif : Le syndrome de vasoconstriction cérébrale réversible (SVCR) est une entité clinico-radiologique associant des céphalées paroxystiques à un vasospasme uni- ou multifocal réversible des artères cérébrales avec ou sans déficit neurologique transitoire ou crise comitiale. Le but de notre étude est de rechercher les facteurs de mauvais pronostic des patients présentant un SVCR. Méthode : Nous avons réalisé une étude rétrospective des imageries vasculaires cérébrales invasives et non invasives entre janvier 2006 et 2011 et avons retenu 10 patients présentant les critères du RCVS. Les données démographiques, facteurs de risque vasculaires ainsi que l'évolution de chaque patient ont été noté. Résultats : Sept des 10 patients sont des femmes, avec un âge médian de 46 ans. Quatre patients ne présentaient pas de facteur étiologique, deux femmes se trouvaient en période post-partum (entre la première et la troisième semaine) et les trois autres cas sont induits par des drogues vaso-actives (cannabis pour 2 cas dont un associé à la cyclosporine, sumatriptan pour un cas). La durée moyenne du suivi est de 10,2 mois (0¬28 mois). Deux patients ont présentés une séquelle neurologique : un a gardé des troubles phasiques et l'autre une hémianopsie latérale homonyme. Deux autres patients sont décédés dans les suites, ce qui est inhabituel. Nous n'avons pas trouvé de corrélation d'évolution différente entre les cas de SVCR primaire ou secondaire. Les seules facteurs corrélaient à l'évolution clinique sont le status neurologique à l'admission et la présence de lésion parenchymateuse (ischémie ou hématome) à l'imagerie. Conclusion : La vasoconstriction cérébrale réversible impliquant des déficits neurologiques ou la mort a été, rarement, rapportée. Nous devons garder à l'esprit qu'une telle évolution peut survenir notamment pour les cas présentant un état neurologique dégradé à l'admission ou présentant des lésions parenchymateuses à l'imagerie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain dysfunction is a frequent complication of sepsis, usually defined as "sepsis-associated encephalopathy" (SAE). Its pathophysiology is complex and related to numerous processes and pathways, while the exact mechanisms producing neurological impairment in septic patients remain incompletely elucidated. Alterations of the cerebral blood flow (CBF) may represent a key component for the development of SAE. Reduction of CBF may be caused by cerebral vasoconstriction, either induced by inflammation or hypocapnia. Endothelial dysfunction associated with sepsis leads to impairment of microcirculation and cerebral metabolic uncoupling that may further reduce brain perfusion so that CBF becomes inadequate to satisfy brain cellular needs. The natural autoregulatory mechanisms that protect the brain from reduced/ inadequate CBF can be impaired in septic patients, especially in those with shock or delirium, and this further contributes to cerebral ischemia if blood pressure drops below critical thresholds. Sedative agents alter cerebro-vascular reactivity and may significantly reduce CBF. Although disorders of brain perfusion and alteration of CBF and cerebral autoregulation are frequently observed in humans with sepsis, their exact role in the pathogenesis of SAE remains unknown. Brain perfusion can further become inadequate due to cerebral microcirculatory dysfunction, as evidenced in the experimental setting. Microvascular alterations can be implicated in the development of electrophysiological abnormalities observed during sepsis and contribute to neurological alterations in septic animals. The aim of this review is to provide an update on the pathophysiology of brain perfusion in sepsis, with a particular focus on human clinical investigation and novel tools for CBF monitoring in septic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulation is a useful tool in cardiac SPECT to assess quantification algorithms. However, simple equation-based models are limited in their ability to simulate realistic heart motion and perfusion. We present a numerical dynamic model of the left ventricle, which allows us to simulate normal and anomalous cardiac cycles, as well as perfusion defects. Bicubic splines were fitted to a number of control points to represent endocardial and epicardial surfaces of the left ventricle. A transformation from each point on the surface to a template of activity was made to represent the myocardial perfusion. Geometry-based and patient-based simulations were performed to illustrate this model. Geometry-based simulations modeled ~1! a normal patient, ~2! a well-perfused patient with abnormal regional function, ~3! an ischaemic patient with abnormal regional function, and ~4! a patient study including tracer kinetics. Patient-based simulation consisted of a left ventricle including a realistic shape and motion obtained from a magnetic resonance study. We conclude that this model has the potential to study the influence of several physical parameters and the left ventricle contraction in myocardial perfusion SPECT and gated-SPECT studies.