AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax and usually comprises Computed Tomography (CT) examination for pre-operative diagnosis. Aiming at the elimination of the high amounts of CT radiation exposure, this work presents a new methodology for the replacement of CT by a laser scanner (radiation-free) in the treatment of pectus excavatum using personally modeled prosthesis. The complete elimination of CT involves the determination of ribs external outline, at the maximum sternum depression point for prosthesis placement, based on chest wall skin surface information, acquired by a laser scanner. The developed solution resorts to artificial neural networks trained with data vectors from 165 patients. Scaled Conjugate Gradient, Levenberg-Marquardt, Resilient Back propagation and One Step Secant gradient learning algorithms were used. The training procedure was performed using the soft tissue thicknesses, determined using image processing techniques that automatically segment the skin and rib cage. The developed solution was then used to determine the ribs outline in data from 20 patient scanners. Tests revealed that ribs position can be estimated with an average error of about 6.82±5.7 mm for the left and right side of the patient. Such an error range is well below current prosthesis manual modeling (11.7±4.01 mm) even without CT imagiology, indicating a considerable step forward towards CT replacement by a 3D scanner for prosthesis personalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the dynamic nature of cardiac function, correct temporal alignment of pre-operative models and intraoperative images is crucial for augmented reality in cardiac image-guided interventions. As such, the current study focuses on the development of an image-based strategy for temporal alignment of multimodal cardiac imaging sequences, such as cine Magnetic Resonance Imaging (MRI) or 3D Ultrasound (US). First, we derive a robust, modality-independent signal from the image sequences, estimated by computing the normalized crosscorrelation between each frame in the temporal sequence and the end-diastolic frame. This signal is a resembler for the left-ventricle (LV) volume curve over time, whose variation indicates di erent temporal landmarks of the cardiac cycle. We then perform the temporal alignment of these surrogate signals derived from MRI and US sequences of the same patient through Dynamic Time Warping (DTW), allowing to synchronize both sequences. The proposed framework was evaluated in 98 patients, which have undergone both 3D+t MRI and US scans. The end-systolic frame could be accurately estimated as the minimum of the image-derived surrogate signal, presenting a relative error of 1:6 1:9% and 4:0 4:2% for the MRI and US sequences, respectively, thus supporting its association with key temporal instants of the cardiac cycle. The use of DTW reduces the desynchronization of the cardiac events in MRI and US sequences, allowing to temporally align multimodal cardiac imaging sequences. Overall, a generic, fast and accurate method for temporal synchronization of MRI and US sequences of the same patient was introduced. This approach could be straightforwardly used for the correct temporal alignment of pre-operative MRI information and intra-operative US images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decades, the value of research on neurological patients’ quality of life (QOL) has become unquestionable. In this context, most studies focus on the relationship between patients’ QOL and their sociodemographic and/or clinical and/or modifiable psychosocial characteristics. They give us information regarding the sociodemographic and clinical profile most prone to low QOL reports and also on ways to improve patients’ QOL (e.g., targeting their selfesteem). Nevertheless, little is known about the role nonmodifiable psychosocial variables can have on patients’ QOL perception. Consequently, the aim of the present study is to explore the relationship between QOL and personality in neurological patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – Numa era em que os tratamentos de Radioterapia Externa (RTE) exigem cada vez mais precisão, a utilização de imagem médica permitirá medir, quantificar e avaliar o impacto do erro provocado pela execução do tratamento ou pelos movimentos dos órgãos. Objetivo – Analisar os dados existentes na literatura acerca de desvios de posicionamento (DP) em patologias de cabeça e pescoço (CP) e próstata, medidos com Cone Beam Computed Tomography (CBCT) ou Electronic Portal Image Device (EPID). Metodologia – Para esta revisão da literatura foram pesquisados artigos recorrendo às bases de dados MEDLINE/PubMed e b-on. Foram incluídos artigos que reportassem DP em patologias CP e próstata medidos através de CBCT e EPID. Seguidamente foram aplicados critérios de validação, que permitiram a seleção dos estudos. Resultados – Após a análise de 35 artigos foram incluídos 13 estudos e validados 9 estudos. Para tumores CP, a média (μ) dos DP encontra-se entre 0,0 e 1,2mm, com um desvio padrão (σ) máximo de 1,3mm. Para patologias de próstata observa-se μDP compreendido entre 0,0 e 7,1mm, com σ máximo de 7,5mm. Discussão/Conclusão – Os DP em patologias CP são atribuídos, maioritariamente, aos efeitos secundários da RTE, como mucosite e dor, que afetam a deglutição e conduzem ao emagrecimento, contribuindo para a instabilidade da posição do doente durante o tratamento, aumentando as incertezas de posicionamento. Os movimentos da próstata devem-se principalmente às variações de preenchimento vesical, retal e gás intestinal. O desconhecimento dos DP afeta negativamente a precisão da RTE. É importante detetá-los e quantificá-los para calcular margens adequadas e a magnitude dos erros, aumentando a precisão da administração de RTE, incluindo o aumento da segurança do doente. - ABSTRACT - Background and Purpose – In an era where precision is an increasing necessity in external radiotherapy (RT), modern medical imaging techniques provide means for measuring, quantifying and evaluating the impact of treatment execution and movement error. The aim of this paper is to review the current literature on the quantification of setup deviations (SD) in patients with head and neck (H&N) or prostate tumors, using Cone Beam Computed Tomography (CBCT) or Electronic Portal Image Device (EPID). Methods – According to the study protocol, MEDLINE/PubMed and b-on databases were searched for trials, which were analyzed using selection criteria based on the quality of the articles. Results – After assessment of 35 papers, 13 studies were included in this analysis and nine were authenticated (6 for prostate and 3 for H&N tumors). The SD in the treatment of H&N cancer patients is in the interval of 0.1 to 1.2mm, whereas in prostate cancer this interval is 0.0 to 7.1mm. Discussion – The reproducibility of patient positioning is the biggest barrier for higher precision in RT, which is affected by geometrical uncertainty, positioning errors and inter or intra-fraction organ movement. There are random and systematic errors associated to patient positioning, introduced since the treatment planning phase or through physiological organ movement. Conclusion – The H&N SD are mostly assigned to the Radiotherapy adverse effects, like mucositis and pain, which affect swallowing and decrease secretions, contributing for the instability of patient positioning during RT treatment and increasing positioning uncertainties. Prostate motion is mainly related to the variation in bladder and rectal filling. Ignoring SD affects negatively the accuracy of RT. Therefore, detection and quantification of SD is crucial in order to calculate appropriate margins, the magnitude of error and to improve accuracy in RTE and patient safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electricity markets are complex environments, involving a large number of different entities, playing in a dynamic scene to obtain the best advantages and profits. MASCEM is a multi-agent electricity market simu-lator to model market players and simulate their operation in the market. Market players are entities with specific characteristics and objectives, making their decisions and interacting with other players. MASCEM pro-vides several dynamic strategies for agents’ behaviour. This paper presents a method that aims to provide market players strategic bidding capabilities, allowing them to obtain the higher possible gains out of the market. This method uses an auxiliary forecasting tool, e.g. an Artificial Neural Net-work, to predict the electricity market prices, and analyses its forecasting error patterns. Through the recognition of such patterns occurrence, the method predicts the expected error for the next forecast, and uses it to adapt the actual forecast. The goal is to approximate the forecast to the real value, reducing the forecasting error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A radioterapia (RT) desempenha um papel fundamental na terapêutica curativa ou paliativa do cancro, sendo aplicada no tratamento de 50 a 60% dos doentes diagnosticados. O seu objectivo é administrar uma dose prescrita de radiação ionizante a um volume alvo com um mínimo de dano para os tecidos sãos circundantes, preservando a sua função. Os desvios relativamente à prescrição poderão comprometer o objectivo do tratamento, levando a possíveis sobredosagens nos tecidos saudáveis e subdosagens no volume de tratamento. A maioria dos tratamentos ocorre sem incidentes e contribui para a qualidade de vida ou cura do doente. No entanto, a RT é reconhecida como um procedimento de alto risco devido à tecnologia e ambiente complexos, bem como ao elevado número de etapas e grupos profissionais envolvidos que trabalham em equipa para prescrever, planear, administrar e monitorizar a terapia. Apesar da baixa taxa de erro e das poucas ou nenhumas consequências clínicas para os doentes associadas, o verdadeiro risco reside na possibilidade de o erro não ser detectado, perpetuando-se no tempo ou afetando vários doentes. Os avanços na tecnologia que proporcionam técnicas mais sofisticadas e precisas representam também uma necessidade crescente de treino exaustivo, formação contínua e atenção por parte dos técnicos de RT que planeiam e administram a terapia. Estes integram uma equipa de especialistas, constituída por médicos, físicos e enfermeiros, que sob a supervisão do médico radioterapeuta se articulam de forma a assegurar um tratamento consistente, preciso e eficiente. Os técnicos de radioterapia trabalham com equipamentos e softwares cada vez mais sofisticados, monitorizam os tratamentos e contactam diariamente com o doente durante o seu tratamento, assumindo a autonomia e responsabilidade de interpretar todo o processo de tratamento e quando necessário articula-se com a restante equipa. A interação profunda entre funções automatizadas, equipamentos tecnologicamente avançados, decisões e atividades humanas que acompanham todo o processo da RT, aliados à pressão crescente para a aplicação das técnicas de tratamento mais avançadas a mais doentes e cumprimento de metas temporais, confere um potencial de risco à atividade do técnico de RT que é por vezes subestimado. O reconhecimento deste potencial passa pelo enquadramento da sua atividade no processo da RT e caracterização do seu papel no mesmo, revelando as suas competências e limitações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Being patient centered is a core value for nursing. Patient centered-care has been related to patient and health provider satisfaction, better health outcomes, higher quality of care and more efficient health care delivery. Objectives - The purpose was to assess the orientation adopted by nurses and students in patient care, using The Patient-Practitioner Orientation Scale, as well as to compare the results between resident nurses and students from different academic years. Settings - Public School of Nursing and a Central Hospital, in Lisbon (Portugal). Participants - Students in the first, second and fourth year of nursing school and nurses participated in the study. Methods - For data collection, we used The Patient-Practitioner Orientation Scale (European Portuguese version), an instrument designed to measure individual preferences toward the dimension of caring a sharing in health professional-patient relationship. Students and nurses also filled out two additional questions about their perception of competence in technical and communication skills. Additional demographic information was also collected, including gender, age, academic year and length of professional experience. Results - A total of 525 students (84.7% female) and 108 nurses (77.8% female) participated in this study. In general, caring sub-scores, measuring the preference of about attending to patient emotional aspects, were higher than sharing sub-scores, measuring beliefs about giving information and perceiving patient as a member of the health team. Students were significantly more patient-centered throughout their nursing education (p<0.001). Comparing to students in the second and fourth academic years (p<0.001) nurses' scores were significantly lower both in total PPOS and in caring and sharing subscales. Conclusions - These results reinforce the idea that patient centeredness may be developed in academic context. The scores obtained highlight the importance of studies that aim to identify factors that may explain the decrease of patient centeredness in professional practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – Quantitative instruments to assess patient safety culture have been developed recently and a few review articles have been published. Measuring safety culture enables healthcare managers and staff to improve safety behaviours and outcomes for patients and staff. The study aims to determine the AHRQ Hospital Survey on Patient Safety Culture (HSPSC) Portuguese version's validity and reliability. Design/methodology/approach – A missing-value analysis and item analysis was performed to identify problematic items. Reliability analysis, inter-item correlations and inter-scale correlations were done to check internal consistency, composite scores. Inter-correlations were examined to assess construct validity. A confirmatory factor analysis was performed to investigate the observed data's fit to the dimensional structure proposed in the AHRQ HSPSC Portuguese version. To analyse differences between hospitals concerning composites scores, an ANOVA analysis and multiple comparisons were done. Findings – Eight of 12 dimensions had Cronbach's alphas higher than 0.7. The instrument as a whole achieved a high Cronbach's alpha (0.91). Inter-correlations showed that there is no dimension with redundant items, however dimension 10 increased its internal consistency when one item is removed. Originality/value – This study is the first to evaluate an American patient safety culture survey using Portuguese data. The survey has satisfactory reliability and construct validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Visual anomalies that affect school-age children represent an important public health problem. Data on the prevalence are lacking in Portugal but is needed for planning vision services. This study was conducted to determine the prevalence of strabismus, decreased visual acuity, and uncorrected refractive error in Portuguese children aged 6 to 11 years. Methods and materials: A cross-sectional study was carried out on a sample of 672 school-age children (7.69 ± 1.19 years). Children received an orthoptic assessment (visual acuity, ocular alignment, and ocular movements) and non-cycloplegic autorefraction. Results: After orthoptic assessment, 13.8% of children were considered abnormal (n = 93). Manifest strabismus was found in 4% of the children. Rates of esotropia (2.1%) were slightly higher than exotropia (1.8%). Strabismus rates were not statistically significant different per sex (p = 0.681) and grade (p = 0.228). Decreased visual acuity at distance was present in 11.3% of children. Visual acuity ≤20/66 (0.5 logMAR) was found in 1.3% of the children. We also found that 10.3% of children had an uncorrected refractive error. Conclusions: Strabismus affects a small proportion of the Portuguese school-age children. Decreased visual acuity and uncorrected refractive error affected a significant proportion of school-age children. New policies need to be developed to address this public health problem.