912 resultados para parametric resonance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper conducts a dynamic stability analysis of symmetrically laminated FGM rectangular plates with general out-of-plane supporting conditions, subjected to a uniaxial periodic in-plane load and undergoing uniform temperature change. Theoretical formulations are based on Reddy's third-order shear deformation plate theory, and account for the temperature dependence of material properties. A semi-analytical Galerkin-differential quadrature approach is employed to convert the governing equations into a linear system of Mathieu-Hill equations from which the boundary points on the unstable regions are determined by Bolotin's method. Free vibration and bifurcation buckling are also discussed as subset problems. Numerical results are presented in both dimensionless tabular and graphical forms for laminated plates with FGM layers made of silicon nitride and stainless steel. The influences of various parameters such as material composition, layer thickness ratio, temperature change, static load level, boundary constraints on the dynamic stability, buckling and vibration frequencies are examined in detail through parametric studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and direct surface plasmon resonance (SPR) method for the kinetic analysis of the interactions between peptide antigens and immobilised monoclonal antibodies (mAb) has been established. Protocols have been developed to overcome the problems posed by the small size of the analytes (< 1600 Da). The interactions were well described by a simple 1:1 bimolecular interaction and the rate constants were self-consistent and reproducible. The key features for the accuracy of the kinetic constants measured were high buffer flow rates, medium antibody surface densities and high peptide concentrations. The method was applied to an extensive analysis of over 40 peptide analogues towards two distinct anti-FMDV antibodies, providing data in total agreement with previous competition ELISA experiments. Eleven linear 15-residue synthetic peptides, reproducing all possible combinations of the four replacements found in foot-and-mouth disease virus (FMDV) field isolate C-S30, were evaluated. The direct kinetic SPR analysis of the interactions between these peptides and three anti-site A mAbs suggested additivity in all combinations of the four relevant mutations, which was confirmed by parallel ELISA analysis. The four-point mutant peptide (A15S30) reproducing site A from the C-S30 strain was the least antigenic of the set, in disagreement with previously reported studies with the virus isolate. Increasing peptide size from 15 to 21 residues did not significantly improve antigenicity. Overnight incubation of A15S30 with mAb 4C4 in solution showed a marked increase in peptide antigenicity not observed for other peptide analogues, suggesting that conformational rearrangement could lead to a stable peptide-antibody complex. In fact, peptide cyclization clearly improved antigenicity, confirming an antigenic reversion in a multiply substituted peptide. Solution NMR studies of both linear and cyclic versions of the antigenic loop of FMDV C-S30 showed that structural features previously correlated with antigenicity were more pronounced in the cyclic peptide. Twenty-six synthetic peptides, corresponding to all possible combinations of five single-point antigenicity-enhancing replacements in the GH loop of FMDV C-S8c1, were also studied. SPR kinetic screening of these peptides was not possible due to problems mainly related to the high mAb affinities displayed by these synthetic antigens. Solution affinity SPR analysis was employed and affinities displayed were generally comparable to or even higher than those corresponding to the C-S8c1 reference peptide A15. The NMR characterisation of one of these multiple mutants in solution showed that it had a conformational behaviour quite similar to that of the native sequence A15 and the X-ray diffraction crystallographic analysis of the peptide ? mAb 4C4 complex showed paratope ? epitope interactions identical to all FMDV peptide ? mAb complexes studied so far. Key residues for these interactions are those directly involved in epitope ? paratope contacts (141Arg, 143Asp, 146His) as well as residues able to stabilise a particular peptide global folding. A quasi-cyclic conformation is held up by a hydrophobic cavity defined by residues 138, 144 and 147 and by other key intrapeptide hydrogen bonds, delineating an open turn at positions 141, 142 and 143 (corresponding to the Arg-Gly-Asp motif).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tongue is the most important and dynamic articulator for speech formation, because of its anatomic aspects (particularly, the large volume of this muscular organ comparatively to the surrounding organs of the vocal tract) and also due to the wide range of movements and flexibility that are involved. In speech communication research, a variety of techniques have been used for measuring the three-dimensional vocal tract shapes. More recently, magnetic resonance imaging (MRI) becomes common; mainly, because this technique allows the collection of a set of static and dynamic images that can represent the entire vocal tract along any orientation. Over the years, different anatomical organs of the vocal tract have been modelled; namely, 2D and 3D tongue models, using parametric or statistical modelling procedures. Our aims are to present and describe some 3D reconstructed models from MRI data, for one subject uttering sustained articulations of some typical Portuguese sounds. Thus, we present a 3D database of the tongue obtained by stack combinations with the subject articulating Portuguese vowels. This 3D knowledge of the speech organs could be very important; especially, for clinical purposes (for example, for the assessment of articulatory impairments followed by tongue surgery in speech rehabilitation), and also for a better understanding of acoustic theory in speech formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance (MR) imaging has been used to analyse and evaluate the vocal tract shape through different techniques and with promising results in several fields. Our purpose is to demonstrate the relevance of MR and image processing for the vocal tract study. The extraction of contours of the air cavities allowed the set - up of a number of 3D reconstruction image stacks by means of the combination of orthogonally oriented sets of slices for e ach articulatory gesture, as a new approach to solve the expected spatial under sampling of the imaging process. In result these models give improved information for the visualization of morphologic and anatomical aspects and are useful for partial measure ments of the vocal tract shape in different situations. Potential use can be found in Medical and therapeutic applications as well as in acoustic articulatory speech modelling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first and second authors would like to thank the support of the PhD grants with references SFRH/BD/28817/2006 and SFRH/PROTEC/49517/2009, respectively, from Fundação para a Ciência e Tecnol ogia (FCT). This work was partially done in the scope of the project “Methodologies to Analyze Organs from Complex Medical Images – Applications to Fema le Pelvic Cavity”, wi th reference PTDC/EEA- CRO/103320/2008, financially supported by FCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

15th International Conference on Mixed Design of Integrated Circuits and Systems, pp. 177 – 180, Poznan, Polónia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Fast Field-Cycling Nuclear Magnetic Resonance (FFC-NMR) is a technique used to study the molecular dynamics of different types of materials. The main elements of this equipment are a magnet and its power supply. The magnet used as reference in this work is basically a ferromagnetic core with two sets of coils and an air-gap where the materials' sample is placed. The power supply should supply the magnet being the magnet current controlled in order to perform cycles. One of the technical issues of this type of solution is the compensation of the non-linearities associated to the magnetic characteristic of the magnet and to parasitic magnetic fields. To overcome this problem, this paper describes and discusses a solution for the FFC-NMR power supply based on a four quadrant DC/DC converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa for the degree of Master in Biomedical Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis presented in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the subject of Electrical and Computer Engineering by the Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Contexto: Indicadores fidedignos da composição corporal são importantes na orientação das estratégias nutricionais de recém-nascidos e pequenos lactentes submetidos a cuidados intensivos. O braço é uma região acessível para avaliar a composição corporal regional, pela medida dos seus compartimentos. A antropometria e a ultrassonografia (US) são métodos não invasivos, relativamente económicos, que podem ser usados à cabeceira do paciente na medição desses compartimentos, embora esses métodos não tenham ainda sido validados neste subgrupo etário. A ressonância magnética (RM) pode ser usada como método de referência na validação da medição dos compartimentos do braço. Objectivo: Validar em lactentes pré-termo, as medidas do braço por antropometria e por US. Métodos: Foi estudada uma coorte de recém-nascidos admitidos consecutivamente na unidade de cuidados intensivos neonatais, com  33 semanas de idade de gestação e peso adequado para a mesma, sem anomalias congénitas major e não submetidas a diuréticos ou oxigenoterapia no momento da avaliação. Nas vésperas da alta, foram efectuadas medições do braço, com ocultação, pelos métodos antropométrico, ultrassonográfico e RM. As medidas antropométricas directas foram: peso (P), comprimento (C), perímetro cefálico (PC), perímetro braquial (PB) e prega cutânea tricipital (PT). As área braquial total, área muscular (AM) e área adiposa foram calculadas pelos métodos de Jeliffee & Jeliffee e de Rolland-Cachera. Utilizando uma sonda PSH-7DLT de 7 Hz no ecógrafo Toshiba SSH 140A foram medidos os perímetros braquial e muscular e calculadas automaticamente as áreas braquial e muscular, sendo a área adiposa obtida por subtracção. Como método de referência foi utilizada a RM – Philips Gyroscan ACS-NT, Power-Track 1000 ®, 1.5 Tesla com uma antena de quadratura do joelho. Na análise estatística foram utilizados os métodos paramétricos e não paramétricos, conforme adequado. Resultados: Foram incluídas 30 crianças, nascidas com ( ±DP) 30.7 ±1.9 semanas de gestação, pesando 1380 ±325g, as quais foram avaliadas às 35.4 ±1.1 semanas de idade corrigida, quando pesavam 1786 ±93g. Nenhuma das medidas antropométricas, individualmente, constitui um indicador aceitável (r2 <0.5) das medições por RM. A melhor e mais simples equação alternativa encontrada é a que estima a AM (r2 = 0.56), derivada dos resultados da análise de regressão múltipla: AMRM = (P x 0.17) + (PB x 5.2) – (C x 6) – 150, sendo o P expresso em g, o C e o PB em cm. Nenhuma das medidas ultrassonográficas constitui um indicador aceitável (r2 <0.4) das medições por RM. Conclusões: A antropometria e as medidas ultrassonográficas do braço não são indicadores fidedignos da composição corporal regional em lactentes pré-termo, adequados para a idade de gestação.----------ABSTRACT: Background: Accurate predictors for body composition are valuable tools guiding nutritional strategies in infants needing intensive care. The upper-arm is a part of the body that is easily accessible and convenient for assessing the regional body composition, throughout the assessment of their compartments. Anthropometry and by ultrasonography (US) are noninvasive and relatively nonexpensive methods for bedside assessment of the upper-arm compartments. However, these methods have not yet been validated in infants. Magnetic resonance imaging (MRI) may be used as gold standard to validate the measurements of the upper-arm compartments. Objective: To validate the upper-arm measurements by anthropometry and by US in preterm infants. Methods: A cohort of neonates consecutively admitted at the neonatal intensive care unit, appropriate for gestational age, with  33 weeks, without major congenital abnormalities and not subjected to diuretics or oxygen therapy, was assessed. Before the discharge, the upper-arm was blindly measured by anthropometry, US and MRI. The direct anthropometric parameters measured were: weight (W), length (L), head circumference (HC), mid-arm circumference (MAC), and tricipital skinfold thickness. The arm area (AA), arm muscle area (AMA) and arm fat area were calculated applying the methods proposed by Jeliffee & Jeliffee and by Rolland-Cachera. Using the sonolayer Toshiba SSH 140A and the probe PSH-7DLT 7Hz, the arm and muscle perimeters were measured by US, the arm and muscle areas included were automatically calculated, and the fat area was calculated by subtraction. The MR images were acquired on a 1.5-T Philips Gyroscan ACS-NT, Power-Track 1000 scanner, and a knee coil was chosen for the upper-arm measurements. For statistical analysis parametric and nonparametric methods were used as appropriate. Results: Thirty infants born with ( ±SD) 30.7 ±1.9 weeks of gestational age and weighing 1380 ±325g were included in the study; they were assessed at 35.4 ±1.1 weeks of corrected age, weighing 1786 ±93g. None of the anthropometric measurements are individually acceptable (r2 <0.5) for prediction of the measurements obtained by MRI. The best and simple alternative equation found is the equation for prediction of the AMA (r2 = 0.56), derived from the results of multiple regression analysis: AMARM = (W x 0.17) + (MAC x 5.2) – (L x 6) – 150, being the W expressed in g, and L and MAC in cm. None of the ultrasonographic measurements are acceptable (r2 <0.5) predictors for the measurements obtained by MRI. Conclusions: The measurements of the upper-arm by anthropometry and by US are not accurate predictors for the regional body composition in preterm appropriate for gestational age infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to Obtain the Degree of Master in Biomedical Engineering