947 resultados para outdoor air flow rate
Resumo:
Due to their detrimental effects on human health, the scientific interest in ultrafine particles (UFP) has been increasing, but available information is far from comprehensive. Compared to the remaining population, the elderly are potentially highly susceptible to the effects of outdoor air pollution. Thus, this study aimed to (1) determine the levels of outdoor pollutants in an urban area with emphasis on UFP concentrations and (2) estimate the respective dose rates of exposure for elderly populations. UFP were continuously measured over 3 weeks at 3 sites in north Portugal: 2 urban (U1 and U2) and 1 rural used as reference (R1). Meteorological parameters and outdoor pollutants including particulate matter (PM10), ozone (O3), nitric oxide (NO), and nitrogen dioxide (NO2) were also measured. The dose rates of inhalation exposure to UFP were estimated for three different elderly age categories: 64–70, 71–80, and >81 years. Over the sampling period levels of PM10, O3 and NO2 were in compliance with European legislation. Mean UFP were 1.7 × 104 and 1.2 × 104 particles/cm3 at U1 and U2, respectively, whereas at rural site levels were 20–70% lower (mean of 1 ×104 particles/cm3). Vehicular traffic and local emissions were the predominant identified sources of UFP at urban sites. In addition, results of correlation analysis showed that UFP were meteorologically dependent. Exposure dose rates were 1.2- to 1.4-fold higher at urban than reference sites with the highest levels noted for adults at 71–80 yr, attributed mainly to higher inhalation rates.
Resumo:
Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.
Resumo:
A presente dissertação tem dois objetivos, o primeiro é a realização de uma auditoria energética e avaliação da qualidade do ar às instalações de uma Piscina Municipal, permitindo a sua classificação energética, e o segundo é o estudo de propostas de melhoria que contribuam para uma melhor eficiência energética do edifício. Na análise à qualidade do ar interior os parâmetros avaliados encontravam-se todos dentro dos limites estabelecidos por lei, com exceção dos valores de COVs que em dois pontos de medição (ambos na nave) ultrapassaram os limites estabelecidos por lei. A auditoria ao edifício permitiu verificar que o caudal mínimo de água nova nas piscinas imposto por lei é cumprido pela instalação. No que diz respeito ao caudal de ar novo introduzido, este apenas é respeitado quando a unidade de tratamento de ar está a debitar 100% da sua capacidade. Quando a unidade opera a 50% da sua capacidade apresenta um défice de 5% do valor mínimo estabelecido. Relativamente às perdas energéticas associadas aos tanques de natação, estas apresentam um valor de 95,89 kW, em que 59,09 kW dizem respeito às perdas por evaporação. Foi também possível concluir que as perdas por evaporação representam cerca de 39% da energia calorifica produzida nas caldeiras. O edifício apresenta um consumo anual de eletricidade de 166 482 kWh em que 69% deste valor é provocado pelas unidades de tratamento de ar e a iluminação apresenta apenas um peso de 3%. Em relação ao gás natural consumido pelas caldeiras o seu valor anual é de 1 317 240 kWh. A simulação dinâmica do edifício permitiu concluir que este apresenta um IEE de 1 269,9 kWh/m2.ano. O rácio de classe energética (RIEE) é de 1,24 o que significa que o edifício pertence à classe energética C. As medidas estudadas para a melhoria da eficiência energética, nomeadamente integração energética com uma central de ciclo combinado, aplicação de cobertura isotérmica nas piscinas e substituição do telhado na zona da nave, mostraram-se viáveis. O estudo da possibilidade da realização de uma integração energética permitiu concluir que a poupança anual é de 9 374 € e o investimento é recuperado em menos de 1,5 anos. Relativamente à aplicação de cobertura isotérmica o investimento é de 14 000 € e é recuperado em 2 anos. A substituição do telhado na zona da nave tem um investimento de 20 500 € e a recuperação realiza-se num período de 3,5 anos.
Resumo:
A presente dissertação realizada na empresa Continental-Indústria Têxtil do Ave, S.A., teve como objetivo a otimização energética da secção das malhas. Esta secção divide-se em duas áreas, a tricotagem e a ramulagem. Os artigos produzidos diferem no seu peso específico, composição e condições de operação, sendo os artigos A, B e C compostos por poliéster e termofixados a 190ºC e os artigos D e E compostos por poliéster e algodão, com uma temperatura de operação de 205ºC. Numa primeira etapa estudou-se o funcionamento da máquina de termofixação – a râmula – que opera em trabalho contínuo a 40 m/min. Esta máquina tem incorporado um permutador de calor, que aquece o ar fresco de entrada com os gases de exaustão das estufas. Posteriormente efetuou-se o levantamento energético de cada artigo, para as áreas de tricotagem e ramulagem. Verificou-se que os artigos D e E, pela sua constituição, são os que apresentam um consumo específico superior, em tep/ton. Entre as várias utilidades consumidas (gás natural, eletricidade e ar comprimido) o gás natural representa mais de 50% do consumo de energia total necessário para a produção de cada artigo. Após a completa análise aos consumos energéticos da râmula, foram realizados ensaios de otimização, tendo-se concluído que a diminuição do caudal de exaustão pode atingir valores de poupança anual de gás natural na ordem dos 3.000 €. Com o objetivo de avaliar o consumo de gás natural, não sendo possível a realização experimental, foram feitas simulações com base em alterações na corrente de entrada de ar fresco no permutador. Foi também estudada a possibilidade de isolamento e revestimento térmico da conduta exterior, projetada para o reaproveitamento do ar dos compressores, tendo-se obtido um orçamento de 2.500 €. Admitindo-se uma gama de temperaturas entre os 40ºC e os 60ºC, com um caudal de insuflação de 30%, obteve-se um payback entre os 0,97 e os 3,28 anos. Numa segunda fase admitiu-se uma temperatura média de 50ºC, aumentando o caudal de insuflação até 100%. O período de retorno obtido variou entre os 0,33 e os 1,38 anos, podendo as poupanças anuais atingirem os 7.600 €.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.
Resumo:
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Resumo:
BACKGROUND: Creatinine clearance is the most common method used to assess glomerular filtration rate (GFR). In children, GFR can also be estimated without urine collection, using the formula GFR (mL/min x 1.73 m2) = K x height [cm]/Pcr [mumol/L]), where Pcr represents the plasma creatinine concentration. K is usually calculated using creatinine clearance (Ccr) as an index of GFR. The aim of the present study was to evaluate the reliability of the formula, using the standard UV/P inulin clearance to calculate K. METHODS: Clearance data obtained in 200 patients (1 month to 23 years) during the years 1988-1994 were used to calculate the factor K as a function of age. Forty-four additional patients were studied prospectively in conditions of either hydropenia or water diuresis in order to evaluate the possible variation of K as a function of urine flow rate. RESULTS: When GFR was estimated by the standard inulin clearance, the calculated values of K was 39 (infants less than 6 months), 44 (1-2 years) and 47 (2-12 years). The correlation between the values of GFR, as estimated by the formula, and the values measured by the standard clearance of inulin was highly significant; the scatter of individual values was however substantial. When K was calculated using Ccr, the formula overestimated Cin at all urine flow rates. When calculated from Ccr, K varied as a function of urine flow rate (K = 50 at urine flow rates of 3.5 and K = 64 at urine flow rates of 8.5 mL/min x 1.73 m2). When calculated from Cin, in the same conditions, K remained constant with a value of 50. CONCLUSIONS: The formula GFR = K x H/Pcr can be used to estimate GFR. The scatter of values precludes however the use of the formula to estimate GFR in pathophysiological studies. The formula should only be used when K is calculated from Cin, and the plasma creatinine concentration is measured in well defined conditions of hydration.
Resumo:
Urea is the most consumed nitrogen fertilizer in the world. However, its agronomic and economic efficiency is reduced by the volatilization of NH3, which can reach 78 % of the applied nitrogen. The coating of urea granules with acidic compounds obtained by charcoal oxidation has the potential to reduce the volatilization, due to the acidic character, the high buffering capacity and CEC. This work aimed to evaluate the effect of HNO3-oxidized carbon on the control of NH3 volatilization. These compounds were obtained by oxidation of Eucalyptus grandis charcoal, produced at charring temperatures of 350 and 450 ºC, with 4.5 mol L-1 HNO3. The charcoal was oxidized by solubilization in acidic or alkaline medium, similar to the procedure of soil organic matter fractionation (CHox350 and CHox450). CHox was characterized by C, H, O, N contents and their respective atomic relations, by the ratio E4 (absorbance 465 nm) by E6 (absorbance 665 nm), and by active acidity and total acidity (CEC). The inhibitory effect of CHox on the urease activity of Canavalia ensiformis was assessed in vitro. The NH3 volatilization from urea was evaluated with and without coating of oxidized charcoal (U-CHox350 or U-CHox450) in a closed system with continuous air flow. The pH of both CHox was near 2.0, but the total acidity of CHox350 was higher, 72 % of which was attributed to carboxylic groups. The variation in the ionization constants of CHox350 was also greater. The low E4/E6 ratios characterize the high stability of the compounds in CHox. CHox did not inhibit the urease activity in vitro, although the maximum volatilization peak from U-CHox450 and U-CHox350 occurred 24 h after that observed for uncoated urea. The lowest volatilization rate was observed for U-CHox350 as well as a 43 % lower total amount of NH3 volatilized than from uncoated urea.
Resumo:
BACKGROUND AND PURPOSE: Sleep disordered breathing (SDB) is frequent in acute stroke patients and is associated with early neurologic worsening and poor outcome. Although continuous positive airway pressure (CPAP) effectively treats SDB, compliance is low. The objective of the present study was to assess the tolerance and the efficacy of a continuous high-flow-rate air administered through an open nasal cannula (transnasal insufflation, TNI), a less-intrusive method, to treat SDB in acute stroke patients. METHODS: Ten patients (age, 56.8 ± 10.7 years), with SDB ranging from moderate to severe (apnea-hypopnea index, AHI, >15/h of sleep) and on a standard sleep study at a mean of 4.8 ± 3.7 days after ischemic stroke (range, 1-15 days), were selected. The night after, they underwent a second sleep study while receiving TNI (18 L/min). RESULTS: TNI was well tolerated by all patients. For the entire group, TNI decreased the AHI from 40.4 ± 25.7 to 30.8 ± 25.7/h (p = 0.001) and the oxygen desaturation index >3% from 40.7 ± 28.4 to 31 ± 22.5/h (p = 0.02). All participants except one showed a decrease in AHI. The percentage of slow-wave sleep significantly increased with TNI from 16.7 ± 8.2% to 22.3 ± 7.4% (p = 0.01). There was also a trend toward a reduction in markers of sleep disruption (number of awakenings, arousal index). CONCLUSIONS: TNI improves SDB indices, and possibly sleep parameters, in stroke patients. Although these changes are modest, our findings suggest that TNI is a viable treatment alternative to CPAP in patients with SDB in the acute phase of ischemic stroke.
Resumo:
BACKGROUND AND PURPOSE: Sleep disordered breathing (SDB) is frequent in acute stroke patients and is associated with early neurologic worsening and poor outcome. Although continuous positive airway pressure (CPAP) effectively treats SDB, compliance is low. The objective of the present study was to assess the tolerance and the efficacy of a continuous high-flow-rate air administered through an open nasal cannula (transnasal insufflation, TNI), a less-intrusive method, to treat SDB in acute stroke patients. METHODS: Ten patients (age, 56.8 ± 10.7 years), with SDB ranging from moderate to severe (apnea-hypopnea index, AHI, >15/h of sleep) and on a standard sleep study at a mean of 4.8 ± 3.7 days after ischemic stroke (range, 1-15 days), were selected. The night after, they underwent a second sleep study while receiving TNI (18 L/min). RESULTS: TNI was well tolerated by all patients. For the entire group, TNI decreased the AHI from 40.4 ± 25.7 to 30.8 ± 25.7/h (p = 0.001) and the oxygen desaturation index >3% from 40.7 ± 28.4 to 31 ± 22.5/h (p = 0.02). All participants except one showed a decrease in AHI. The percentage of slow-wave sleep significantly increased with TNI from 16.7 ± 8.2% to 22.3 ± 7.4% (p = 0.01). There was also a trend toward a reduction in markers of sleep disruption (number of awakenings, arousal index). CONCLUSIONS: TNI improves SDB indices, and possibly sleep parameters, in stroke patients. Although these changes are modest, our findings suggest that TNI is a viable treatment alternative to CPAP in patients with SDB in the acute phase of ischemic stroke.
Resumo:
Työn tarkoituksena oli vertailla kahta kaupallista prosessiuunisimulointiohjelmaa sekä selvittää onko toinen ohjelma soveltuva Neste Jacobs Oy:n käyttöön. Tavoitteena oli selvittää ohjelmien ominaisuuksien eroja ja rajoitteita sekä tuloksien yhdenmukaisuutta. Kirjallisuusosassa perehdyttiin prosessiuunien toimintaperiaatteisiin, yleisiin mitoitusperiaatteisiin ja säteilylämmönsiirron perusteisiin. Kirjallisuusosassa käsiteltiin myös prosessiuunien polttimien toimintaa ja NOx-päästöjä vähentäviä polttotekniikoita. Molemmilla laskentaohjelmilla laadittiin kuumaöljy- ja tyhjöuuni, joiden tuloksia vertailtiin tärkeimpien prosessiarvojen perusteella ja toisen ohjelman osalta myös laitevalmistajan ilmoittamiin arvoihin. Tällä ohjelmalla tutkittiin tyhjöuunin höyrynruiskutuksen ja koksaantumisen vaikutuksia prosessiin sekä säteilyosan leveyden muutoksen vaikutusta säteilylämmönsiirtoon. Ohjelmien ominaisuuksien keskeisimmät erot liittyivät kaksifaasivirtauksen laskentaan, prosessiaineen massavirran rajoituksiin, ilman esilämmittimen käyttöön ja laskentamallien paineen kontrollointiin. Tulokset erosivat savukaasun ja tuubien lämpötilojen ja painehäviön laskennassa. Tuloksien ja ominaisuuksien perusteella toisen ohjelman ei todettu olevan täysin soveltuva Neste Jacobs Oy:n käyttöön.
Resumo:
Diplomityössä tutkitaan kolmea erilaista virtausongelmaa CFD-mallinnuksella. Yhteistä näille ongelmille on virtaavana aineena oleva ilma. Lisäksi tapausten perinteinen mittaus on erittäin vaikeaa tai mahdotonta. Ensimmäinen tutkimusongelma on tarrapaperirainan kuivain, jonka tuotantomäärä halutaan nostaa kaksinkertaiseksi. Tämä vaatii kuivatustehon kaksinkertaistamista, koska rainan viipymäaika kuivausalueella puolittuu. Laskentayhtälöillä ja CFD-mallinnuksella tutkitaan puhallussuihkun nopeuden ja lämpötilan muutoksien vaikutusta rainan pinnan lämmön- ja massansiirtokertoimiin. Tuloksena saadaan varioitujen suureiden sekä massan- ja lämmönsiirtokertoimien välille riippuvuuskäyrät, joiden perusteella kuivain voidaan säätää parhaallamahdollisella tavalla. Toinen ongelma käsittelee suunnitteilla olevan kuparikonvertterin sekundaarihuuvan sieppausasteen optimointia. Ilman parannustoimenpiteitä käännetyn konvertterin päästöistä suurin osa karkaa ohi sekundaarihuuvan. Tilannetta tutkitaan konvertterissa syntyvän konvektiivisen nostevirtauksen eli päästöpluumin sekä erilaisten puhallussuihkuratkaisujen CFD-mallinnuksella. Tuloksena saadaan puhallussuihkuilla päästöpluumia poikkeuttava ilmaverho. Suurin osa nousevasta päästöpluumista indusoituu ilmaverhoon ja kulkeutuu poistokanavaan. Kolmas tutkittava kohde on suunnitteilla oleva kuparielektrolyysihalli, jossa ilmanvaihtoperiaatteena on luonnollinen ilmanvaihto ja mekaaninen happosumun keräysjärjestelmä. Ilmanvaihtosysteemin tehokkuus ja sisäilman virtaukset halutaan selvittää ennen hallin rakentamista. CFD-mallinnuksella ja laskentayhtälöillä tutkitaan lämpötila- ja virtauskentät sekä hallin läpi virtaava ilmamäärä ja ilmanvaihtoaste. Tulo- ja poistoilma-aukkojen mitoitukseen ja sijoitukseen liittyvät suunnitteluarvot varmennetaan sekä löydetään ilmanvaihdon ongelmakohdat. Ongelmakohtia tutkitaan ja niille esitetään parannusehdotukset.
Resumo:
Small centrifugal compressors are more and more widely used in many industrialsystems because of their higher efficiency and better off-design performance comparing to piston and scroll compressors as while as higher work coefficient perstage than in axial compressors. Higher efficiency is always the aim of the designer of compressors. In the present work, the influence of four partsof a small centrifugal compressor that compresses heavy molecular weight real gas has been investigated in order to achieve higher efficiency. Two parts concern the impeller: tip clearance and the circumferential position of the splitter blade. The other two parts concern the diffuser: the pinch shape and vane shape. Computational fluid dynamics is applied in this study. The Reynolds averaged Navier-Stokes flow solver Finflo is used. The quasi-steady approach is utilized. Chien's k-e turbulence model is used to model the turbulence. A new practical real gas model is presented in this study. The real gas model is easily generated, accuracy controllable and fairly fast. The numerical results and measurements show good agreement. The influence of tip clearance on the performance of a small compressor is obvious. The pressure ratio and efficiency are decreased as the size of tip clearance is increased, while the total enthalpy rise keeps almost constant. The decrement of the pressure ratio and efficiency is larger at higher mass flow rates and smaller at lower mass flow rates. The flow angles at the inlet and outlet of the impeller are increased as the size of tip clearance is increased. The results of the detailed flow field show that leakingflow is the main reason for the performance drop. The secondary flow region becomes larger as the size of tip clearance is increased and the area of the main flow is compressed. The flow uniformity is then decreased. A detailed study shows that the leaking flow rate is higher near the exit of the impeller than that near the inlet of the impeller. Based on this phenomenon, a new partiallyshrouded impeller is used. The impeller is shrouded near the exit of the impeller. The results show that the flow field near the exit of the impeller is greatly changed by the partially shrouded impeller, and better performance is achievedthan with the unshrouded impeller. The loading distribution on the impeller blade and the flow fields in the impeller is changed by moving the splitter of the impeller in circumferential direction. Moving the splitter slightly to the suction side of the long blade can improve the performance of the compressor. The total enthalpy rise is reduced if only the leading edge of the splitter ismoved to the suction side of the long blade. The performance of the compressor is decreased if the blade is bended from the radius direction at the leading edge of the splitter. The total pressure rise and the enthalpy rise of thecompressor are increased if pinch is used at the diffuser inlet. Among the fivedifferent pinch shape configurations, at design and lower mass flow rates the efficiency of a straight line pinch is the highest, while at higher mass flow rate, the efficiency of a concave pinch is the highest. The sharp corner of the pinch is the main reason for the decrease of efficiency and should be avoided. The variation of the flow angles entering the diffuser in spanwise direction is decreased if pinch is applied. A three-dimensional low solidity twisted vaned diffuser is designed to match the flow angles entering the diffuser. The numerical results show that the pressure recovery in the twisted diffuser is higher than in a conventional low solidity vaned diffuser, which also leads to higher efficiency of the twisted diffuser. Investigation of the detailed flow fields shows that the separation at lower mass flow rate in the twisted diffuser is later than in the conventional low solidity vaned diffuser, which leads to a possible wider flow range of the twisted diffuser.
Resumo:
Objetivou-se com este trabalho avaliar a distribuição de líquido da ponta de pulverização com indução de ar e jato excêntrico AIUB 8502 sob diferentes condições operacionais. Foram avaliados perfil individual, vazão, ângulo de abertura do jato, faixa de aplicação e distribuição volumétrica simulada de duas pontas AIUB 8502 nas pressões de trabalho de 200, 300, 400 e 500 kPa, altura de 30, 40 e 50 cm em relação ao alvo e espaçamento entre pontas de 30 a 100 cm. Todas as análises foram realizadas seguindo a norma ISSO 5682-1, com algumas adaptações. A ponta apresentou distribuição de líquido excêntrica com um lado descontínuo e extremidade oposta excêntrica, com queda abrupta do volume de líquido. À medida que se aumentou a altura da barra e a pressão de trabalho, alongou-se o perfil do jato. O maior número de configurações uniformes foi obtido na altura de 50 cm, decrescendo nas alturas de 40 e 30 cm. A vazão e o ângulo do jato excêntrico aumentaram com o incremento na pressão, não havendo diferença entre o ângulo do jato descontínuo e o total entre as pressões de 400 e 500 kPa e de 200 e 300 kPa.