792 resultados para miniature


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniature planar waveguide and fiber-based delay lines and buffers including slow light resonant structures and devices are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several materials have been used for tissue engineering purposes, since the ideal matrix depends on the desired tissue. Silk biomaterials have come to focus due to their great mechanical properties. As untreated silkworm silk has been found to be quite immunogenic, an alternative could be spider silk. Not only does it own unique mechanical properties, its biocompatibility has been shown already in vivo. In our study, we used native spider dragline silk which is known as the strongest fibre in nature. Methodology/Principal Findings: Steel frames were originally designed and manufactured and woven with spider silk, harvesting dragline silk directly out of the animal. After sterilization, scaffolds were seeded with fibroblasts to analyse cell proliferation and adhesion. Analysis of cell morphology and actin filament alignment clearly revealed adherence. Proliferation was measured by cell count as well as determination of relative fluorescence each after 1, 2, 3, and 5 days. Cell counts for native spider silk were also compared with those for trypsin-digested spider silk. Spider silk specimens displayed less proliferation than collagen-and fibronectin-coated cover slips, enzymatic treatment reduced adhesion and proliferation rates tendentially though not significantly. Nevertheless, proliferation could be proven with high significance (p<0.01). Conclusion/Significance: Native spider silk does not require any modification to its application as a biomaterial that can rival any artificial material in terms of cell growth promoting properties. We could show adhesion mechanics on intracellular level. Additionally, proliferation kinetics were higher than in enzymatically digested controls, indicating that spider silk does not require modification. Recent findings concerning reduction of cell proliferation after exposure could not be met. As biotechnological production of the hierarchical composition of native spider silk fibres is still a challenge, our study has a pioneer role in researching cellular mechanics on native spider silk fibres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these manipulators experience efficiency losses when operated outside their target performance ranges. The unidirectional actuation behavior of a miniature PAM bundle and bidirectional actuation behavior of an antagonistic pair of miniature PAM bundles are characterized and modeled. The results are used to motivate the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle to improve the operating efficiency of the actuator. Additionally, the fabrication and quasi-static testing results for PAMs assembled from candidate space qualified bladder and braided sleeve materials for use in space robotics are assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design, implementation, and evaluation of a miniature rectenna for energy harvesting applications. The rectenna produces DC power from a distant microwave energy transmitter. The generated DC power is then utilized to operate a head-mountable deep brain stimulation device. The rectenna consists of a miniature three-layer planar inverted-F antenna and a Schottky-diode-based bridge rectifier. The antenna has a volume of π × 6 × 1.584 mm3, a resonance frequency of 915 MHz with a simulated bandwidth of 18 MHz (907-925 MHz), and a measured bandwidth of 18 MHz (910-928 MHz) at the return loss of -10 dB. A dielectric substrate of FR-4 of εr = 4.5 and δ = 0.02 is used for simulation and fabrication of the antenna and the rectifier due to its low cost. An L-section impedance matching circuit is employed between the antenna and the rectifier to reduce the mismatch loss. The impedance matching circuit operates as a low-pass filter eliminating higher order harmonics. A deep brain stimulation device is successfully operated by the rectenna at a distance of 20 cm away from a microwave energy transmitter of power 26.77 dBm. The motivation of this paper includes creation of a deep brain stimulation device that operates indefinitely without a battery. From the application standpoint, the developed energy harvesting rectenna facilitates long-term deep brain stimulation of laboratory animals for preclinical research investigating neurological disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research is being conducted on the use of transcranial direct current stimulation (tDCS) for therapeutic effects, and also on the mechanisms through which such therapeutic effects are mediated. A bottleneck in the progress of the research has been the large size of the existing tDCS systems which prevents subjects from performing their daily activities. To help research into the principles, mechanisms, and benefits of tDCS, reduction of size and weight, improvement in simplicity and user friendliness, portability, and programmability of tDCS systems are vital. This paper presents a design for a low-cost, light-weight, programmable, and portable tDCS device. The device is head-mountable and can be concealed in a hat and worn on the head by the subject while receiving the stimulation. The strength of the direct current stimulation can be selected through a simple user interface. The device is constructed and its performance evaluated through bench and in vivo tests. The tests validated the operation of the device in inducing neuromodulatory changes in primary motor cortex, M1, through measuring excitability of dominant M1 of resting right first dorsal interosseus muscle by transcranial magnetic stimulation induced motor evoked potentials. It was observed that the tDCS device induced comparable neuromodulatory effects in M1 as the existing bulky tDCS systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a minibioreactor platform made of low cost polymers is presented. The minibioreactor prototype was designed as an alternative solution for carrying out microbial fermentation experiments in laboratory. The minibioreactor prototype has a working volume of 1.5 mL and was fabricated from poly(methylmethacrylate) (PMMA) and poly(dimethylsiloxane) (PDMS) polymers. Cell density was measured online whilst agitation rates and the temperature of the reactor content can be tightly controlled to desired set-point values. As proof-of-concept, various S. cerevisae fermentation experiments were conducted. In every experiment, the minibioreactor operated stably for the entire length of operation which was nearly 40 h with very minimal volume loss i.e. about 2.8 μ·h-1 at 37°C. The minibioreactor has the maximum oxygen transfer rate (OTR) of 16.6 mmol·L-1·h-1 under the agitation rate of 300 rpm. Under these conditions, cell specific growth rate as high as 0.291 h-1 was obtained. The experimental data in the minibioreactor operation was also reproducible using shake flask where similar growth profiles were attained under a similar growth conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a portable neural recording device for use with laboratory animals. It can detect and record neural signals from the cortical region of the brain during pre-clinical trials. The device utilizes simplified circuitry to perform signal detection, filtering, sampling, and storage. It includes analog and digital components each implemented on a separate small printed circuit board. The two printed circuit boards are then attached to one another to form the device. It is capable of uninterrupted operation for over 2 hours on a single coin battery. A bench-testing of the device was performed with pre-recorded neural signal which then injected to the input of the device to give validation of efficient operation of the device. Its amplification and filtration features have been analyzed. An overall 56 dB amplification and filtration in the frequency range of 300 Hz to 4 KHz was achieved. Sampling and storage at a reduced power and computational load is demonstrated with uninterrupted storage of the neural signal. A comparison of the input and reconstructed neural signals shows minimal variation error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a renewable and non-polluting energy source, wind is used to produce electricity via large-diameter horizontal or vertical axis wind turbines. Such large wind turbines have been well designed and widely applied in industry. However, little attention has been paid to the design and development of miniature wind energy harvesters, which have great potential to be applied to the HVAC (heating, ventilating and air conditions) ventilation exhaust systems and household personal properties. In this work, 10 air-driven electromagnetic energy harvesters are fabricated using 3D printing technology. Parametric measurements are then conducted to study the effects of (1) the blade number, (2) its geometric size, (3) aspect ratio, presence or absence of (4) solid central shaft, (5) end plates, and (6) blade orientation. The maximum electrical power is 0.305 W. To demonstrate its practical application, the electricity generated is used to power 4 LED (light-emitting diode) lights. The maximum overall efficiency ηmax is approximately 6.59%. The cut-in and minimum operating Reynolds numbers are measured. The present study reveals that the 3D printed miniature energy harvesters provide a more efficient platform for harnessing ‘wind power’.