935 resultados para methodologies for greenhouse gases emissions inventory and CO2 capture and storage
Resumo:
Ethnographic methodologies developed in social anthropology and sociology hold considerable promise for addressing practical, problem-based research concerned with the construction site. The extended researcher-engagement characteristic of ethnography reveals rich insights, yet is infrequently used to understand how workplace realities are lived out on construction sites. Moreover, studies that do employ these methods are rarely reported within construction research journals. This paper argues that recent innovations in ethnographic methodologies offer new routes to: posing questions; understanding workplace socialities (i.e. the qualities of the social relationships that develop on construction sites); learning about forms, uses and communication of knowledge on construction sites; and turning these into meaningful recommendations. This argument is supported by examples from an interdisciplinary ethnography concerning migrant workers and communications on UK construction sites. The presented research seeks to understand how construction workers communicate with managers and each other and how they stay safe on site, with the objective of informing site health-and-safety strategies and the production and evaluation of training and other materials.
Resumo:
This paper examines the ethics of the Clean Development Mechanism (CDM) in its architecture, processes and outcomes and its potential to allocate resources to the poor as ‘ethical development’. Two specific examples of CDM projects help us to explore some of the quandaries that seem to be quickly defining operating procedure for the CDM in its efforts to bring entitlementsto the poor. The paper concludes with reflections on the normative and social complications of the CDM and closes with three key areas of further investigation.
Resumo:
We employ a large dataset of physical inventory data on 21 different commodities for the period 1993–2011 to empirically analyze the behavior of commodity prices and their volatility as predicted by the theory of storage. We examine two main issues. First, we analyze the relationship between inventory and the shape of the forward curve. Low (high) inventory is associated with forward curves in backwardation (contango), as the theory of storage predicts. Second, we show that price volatility is a decreasing function of inventory for the majority of commodities in our sample. This effect is more pronounced in backwardated markets. Our findings are robust with respect to alternative inventory measures and over the recent commodity price boom.
Synergetic effect of carbon nanopore size and surface oxidation on CO2 capture from CO2/CH4 mixtures
Resumo:
We have studied the synergetic effect of confinement (carbon nanopore size) and surface chemistry (the number of carbonyl groups) on CO2 capture from its mixtures with CH4 at typical operating conditions for industrial adsorptive separation (298 K and compressed CO2CH4 mixtures). Although both confinement and surface oxidation have an impact on the efficiency of CO2/CH4 adsorptive separation at thermodynamics equilibrium, we show that surface functionalization is the most important factor in designing an efficient adsorbent for CO2 capture. Systematic Monte Carlo simulations revealed that adsorption of CH4 either pure or mixed with CO2 on oxidized nanoporous carbons is only slightly increased by the presence of functional groups (surface dipoles). In contrast, adsorption of CO2 is very sensitive to the number of carbonyl groups, which can be examined by a strong electric quadrupolar moment of CO2. Interestingly, the adsorbed amount of CH4 is strongly affected by the presence of the co-adsorbed CO2. In contrast, the CO2 uptake does not depend on the molar ratio of CH4 in the bulk mixture. The optimal carbonaceous porous adsorbent used for CO2 capture near ambient conditions should consist of narrow carbon nanopores with oxidized pore walls. Furthermore, the equilibrium separation factor was the greatest for CO2/CH4 mixtures with a low CO2 concentration. The maximum equilibrium separation factor of CO2 over CH4 of ∼18–20 is theoretically predicted for strongly oxidized nanoporous carbons. Our findings call for a review of the standard uncharged model of carbonaceous materials used for the modeling of the adsorption separation processes of gas mixtures containing CO2 (and other molecules with strong electric quadrupolar moment or dipole moment).
Resumo:
Video feito pela WWV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Este artigo pretende estudar a inserção do Brasil no Mecanismo de Desenvolvimento Limpo (MDL) do Protocolo de Quioto, por meio de projetos em energia limpa, enfatizando a cooperação entre países desenvolvidos e em desenvolvimento e visando as ações práticas que esse mecanismo permite desenvolver para se alcançar o desenvolvimento sustentável e para conter o aquecimento global. Para isto, realizou-se extensa revisão bibliográfica dos acordos internacionais referentes às mudanças climáticas e de livros e artigos sobre a inserção brasileira no Protocolo de Quioto e no Mecanismo de Desenvolvimento Limpo. O Protocolo de Quioto é um acordo internacional que prevê a redução das emissões de gases de efeito estufa por intermédio de mecanismos flexibilizadores. O Mecanismo de Desenvolvimento Limpo é o único que permite a participação de países em desenvolvimento, para que eles reduzam emissões por meio de projetos que busquem o desenvolvimento sustentável. Neste contexto, o Brasil surge como um país atrativo para o recebimento destes projetos, por sua vocação para desenvolver fontes alternativas de energia e pela sua liderança no processo negociador do Protocolo. O MDL configura-se, portanto, em uma grande oportunidade para o Brasil, visto que esses projetos representam uma fonte de recursos financeiros para que o país busque o desenvolvimento sustentável, além de incentivarem um maior conhecimento científico e a adoção de novas tecnologias.
Resumo:
Includes bibliography
O mecanismo de desenvolvimento limpo como mitigador do aquecimento global e a participação do Brasil
Resumo:
Este estudo, de relevância econômico-ambiental, parte do problema do aquecimento global para analisar o Mecanismo de Desenvolvimento Limpo (MDL) como uma ferramenta capaz de contribuir para a mitigação dos gases de efeito estufa (GEE) por meio do cumprimento de metas de redução de emissões pré estabelecidas pelo Protocolo de Quioto. Examina-se e participação do Brasil como país hospedeiro dos projetos do MDL. Conclui-se que, embora a implementação do MDL diminua o custo global de redução de emissões de gases estufa pelos países desenvolvidos e apóie iniciativas que promovam o desenvolvimento sustentável, a falta de maior especificidade nas regras do mecanismo pode abrir precedentes ao direito de poluir. Entende-se que o mecanismo não deve restringir-se somente ao cumprimento de meta, mas é fundamental que atue como desestimulante da poluição em sua origem, conforme a proposta de sustentabilidade, norte da política ambiental climática.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Seit seiner Entdeckung im Jahre 1978 wurden für hyperpolarisiertes (HP) 129Xe zahlreiche Anwendungen gefunden. Aufgrund seiner hohen Verstärkung von NMR-Signalen wird es dabei typischerweise für Tracer- und Oberflächenstudien verwendet. Im gasförmigen Zustand ist es ein interessantes, klinisches Kontrastmittel, welches für dynamische Lungen MRT genutzt oder auch in Blut oder lipophilen Flüssigkeiten gelöst werden kann. Weiterhin findet HP-Xe auch in der Grundlagenphysik in He-Xe Co-Magnetometern Verwendung, mit welchen z. B. das elektrische Dipolmoment von Xe bestimmt werden soll, oder es dient zur Überprüfung auf Lorentz-Invarianzen. Alle diese Anwendungen profitieren von einem hohen Polarisationsgrad (PXe), um hohe Signalstärken und lange Lagerzeiten zu erreichen. rnIn dieser Arbeit wurden zwei mobile Xe-Polarisatoren konstruiert: einer für Experimente in der Grundlagenphysik mit einer Produktionsrate von 400 mbar·l/h mit PXe ≈ 5%. Der zweite Xe-Polarisator wurde für medizinische Anwendungen entwickelt und soll 1 bar l/h mit PXe > 20% erzeugen. Der letztere wurde noch nicht getestet. Die Arbeitsbedingungen des Xe-Polarisators für Grundlagenphysik (Strömung des Gasgemischs, Temperatur, Druck und Konzentration von Xe) wurden variiert, um einen höchstmöglichen Polarisationsgrad zu erzielen. Die maximale Polarisation von 5,6 % wurde bei Verwendung eine Gasmischung von 1% Xe bei einem Durchfluss von 200 ml/min, einer Temperatur von 150°C und einem Gesamtdruck von 4 bar erreicht. rnWeiterhin muss HP-Xe auch effizient gelagert werden, um Polarisationsverluste zu minimieren. Das ist besonders für solche Anwendungen notwendig, welche an einem entfernten Standort durchgeführt werden sollen oder auch wenn lange Spinkohärenzeiten gefordert sind, z.B. bei He-Xe Co-Magnetometern. rnHierbei bestand bisher die größte Schwierigkeit darin, die Reproduzierbarkeit der gemessenen Lagerzeiten sicherzustellen. In dieser Arbeit konnte die Spin-Gitter-Relaxationszeit (T1) von HP-129Xe in unbeschichteten, Rb-freien, sphärischen Zellen aus Aluminiumsilikatglas (GE-180) signifikant verbessert werden. Die T1–Zeit wurde in einem selbstgebauten Niederfeld-NMR-System (2 mT) sowohl für reines HP-Xe als auch für HP-Xe in Mischungen mit N2, SF6 und CO2 bestimmt. Bei diesen Experimenten wurde die maximale Relaxationszeit für reines Xe (85% 129 Xe) bei (4,6 ± 0,1) h festgestellt. Dabei lagen die typischen Wand-Relaxationszeiten bei ca. 18 h für Glaszellen mit einem Durchmesser von 10 cm. Des Weiteren wurde herausgefunden, dass CO2 eine unerwartet hohe Effizienz bei der Verkürzung der Lebensdauer der Xe-Xe Moleküle zeigte und somit zu einer deutlichen Verlängerung der gesamten T1-Zeit genutzt werden kann. rnIm Verlauf vieler Experimente wurde durch wiederholte Messungen mit der gleichen Zelle, ein "Alterungsprozess“ bei der Wandrelaxation identifiziert und untersucht. Dieser Effekt könnte leicht rückgängig gemacht werden, indem die anfängliche Reinigungsprozedur wiederholt wurde. Auf diese Weise kann eine konstante Wandrelaxation sichergestellt werden, durch die sehr reproduzierbare T1-Messungen möglich werden. rnSchließlich wurde die maximale Relaxationszeit für HP-Xe mit natürlicher Häufigkeit in Mischungen mit SF6 bestimmt. Überraschenderweise war dieser Wert um ca. 75% niedriger als der Wert für Xenon, das zu 85% mit 129Xe angereichert war. Dieser Effekt wurde durch drei unabhängige Experimente bestätigt, da er nicht von der bestehenden Theorie der Xe-Relaxation ableitbar ist. rnDie Polarisation von HP-Xe, PXe, wird normalerweise durch den Vergleich der NMR-Signale des HP-Xe mit einer thermischen polarisierten Probe (z. B. 1H2O oder Xe) bestimmt. Dabei beinhaltet der Vergleich unterschiedlicher Messungen an verschiedenen Proben (unterschiedlicher Druck, Signalintensität und Messverfahren) viele experimentelle Unsicherheiten, welche sich oft nicht leicht bestimmen lassen. Eine einfache, genaue und kostengünstige Methode zur Bestimmung von PXe durch eine direkte Messung der makroskopischen Magnetisierung in einem statischen Magnetfeld vermeidet alle diese Unsicherheiten. Dieses Verfahren kann Polarisationen von > 2 % mit einer Genauigkeit von maximal 10% fast ohne Polarisationsverlust bestimmen. Zusätzlich kann diese Methode ohne weitere Änderungen auch für Bestimmungen des Polarisationsgrades anderer HP-Gase verwendet werden.rn
Tidal volume single breath washout of two tracer gases--a practical and promising lung function test
Resumo:
Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing.