906 resultados para metallic elements
Resumo:
A flexible and low cost energy harvester device based on the magnetoelectric (ME) effect has been designed using Fe64Co17Si7B12 as amorphous magnetostrictive ribbons and PVDF as the piezoelectric element. Sandwich-type laminated composite of 3 cm long has been fabricated by gluing these ribbons to the PVDF with the Devcon 5 minute epoxy. Good power output and power density of 6.4 μW and 1.5 mW/cm3, respectively, have been obtained through a multiplier circuit. All values have been measured at the magnetomechanical resonance of the laminate. The effect of the length of the ME laminate on the power output has been also studied, exhibiting a decay as the length of the ME laminate does. Nevertheless, good performance of such device has been obtained for a 0.5 cm long device, working already at 337 KHz, within the low radio frequency (LRF) range.
Resumo:
A study was carried out to evaluate the association of levels of radioactivity, selenium and aflatoxin in shelled Brazil nuts, which were classified in different sizes, for export. The selenium determinations were performed by inductively coupled plasma optical emission spectrometry (LOQ = 3.0 µg g-1), and aflatoxins were detected by Liquid chromatography-mass spectrometry (LOQ = 0.85 µg kg-1), recovery rates were between 92 and 100%. Radioactivity was measured by high-resolution gamma spectrometry. The selenium mean concentration was (22.7 ± 7.4) µg g-1. (n = 30). Mean activities determined for the following radium isotopes were: 15.77 Bq kg-1 for 224Ra, 104.8 Bq kg-1 for 226Ra and 99.48 Bq kg-1 for 228Ra. For 226Ra, the levels did not vary significantly with nut sizes, although such differences were observed for 224Ra and 228Ra. There was no statistically significant association between the level of selenium and the activity of radionuclides, however, there was correlation between the radionuclides. Aflatoxins above the quantification limit were not found.
Resumo:
Dissertação de mestrado em Engenharia de Materiais
Resumo:
"Series title: Springerbriefs in applied sciences and technology, ISSN 2191-530X"
Resumo:
OBJECTIVE: To evaluate the immediate results of percutaneous mechanical mitral commissurotomy. METHODS: Thirty patients underwent percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome from 8/11/99 to 2/4/00. Mean age was 30.7 years, and 73.3% were women. With regards to functional class, 63.3% were class III, and 36.7% were class IV. The echocardiographic score had a mean value of 7.5± 1.8. RESULTS: The mitral valve area increased from 0.97±0.15cm² to 2.16±0.50cm² (p>0.0001). The mean diastolic gradient decreased from 17.9±5.0mmHg to 3.2±1.4mmHg. The mean left atrial pressure decreased from 23.6±5.4mmHg to 8.6±3.1mmHg, (p>0.0001). Systolic pressure in the pulmonary artery decreased from 52.7±18.3mmHg to 32.2±7.4mmHg. Twenty-nine cases were successful. One patient developed severe mitral regurgitation. Interatrial septal defect was observed and one patient. One patient had cardiac tamponade due to left ventricular perforation. No deaths occurred. CONCLUSION: This method has proven to be safe and efficient in the treatment of rheumatic mitral stenosis. The potential advantage is that it can be used multiple times after sterilization, which decreases procedural costs significantly.
Resumo:
2nd ed
Resumo:
Pt. 1