948 resultados para left trisectionectomy
Resumo:
We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.
Resumo:
Background: Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision. Methods: Retrospective analysis of 75 patients who received TPLVAD to treat cardiogenic shock (n = 49) or to facilitate high-risk percutaneous coronary intervention (PCI) (n = 26). Forty-two patients with cardiogenic shock and 16 patients with high-risk PCI received a TandemHeart and 7 patients and 10 patients, respectively, received an Impella Recover LP 2.5. Outcome and related complications up to 1 month are reported with reference to device depending function. Results: One-month survival was 53% in patients with shock and 96% in patients with PCI. Conclusion: TPLVADs can support the failing heart with acceptable risk. Outcome is better in prophylactic use than in patients with cardiogenic shock. (C) 2011 Wiley-Liss, Inc.
Resumo:
AIMS: Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a 'back-up' implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). CONCLUSION: Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strategy.
Resumo:
Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.
Resumo:
The population of industrialized societies has increased tremendously over the last century, raising the question on how an enhanced age affects cognition. The relevance of two models of healthy aging are contrasted in the present study that both target the functioning of the two cerebral hemispheres. The right hemi-aging model (RHAM) assumes that functions of the right hemisphere decline before those of the left hemisphere. The Hemispheric Asymmetry Reduction in Older Adults (HAROLD) Model suggests that the contralateral hemisphere supports the normally superior hemisphere in a given task resulting in a reduced hemispheric asymmetry overall. In a mixed design, 20 younger and 20 older adults performed both a task assessing a left (lateralized lexical decisions) and a right (sex decisions on chimeric faces) hemisphere advantage. Results indicated that lateralized performance in both tasks was attenuated in older as compared to younger adults, in particular in men. These observations support the HAROLD model. Future studies should investigate whether this reduced functional hemispheric asymmetry in older age results from compensatory processes or from a process of de-differentiation
Resumo:
BACKGROUND: Intracoronary injection of autologous bone marrow-derived mononucleated cells (BM-MNC) may improve LV function shortly after acute ST elevation myocardial infarction (STEMI), but little is known about the long-term durability of the treatment effect. METHODS: In a single-centre trial a total of 60 patients with acute anterior STEMI, successful reperfusion therapy and a left ventricular ejection fraction (LVEF) of <50% were screened for the study. 23 patients were actively treated with intracoronary infusion of BM-MNC within a median of 3 days. The open-label control group consisted of 19 patients who did not consent to undergo BM-MNC treatment but agreed to undergo regular clinical and echocardiographic follow-up for up to 5 years after AMI. RESULTS: Whereas at 4 months there was no significant difference between the increase in LVEF in the BM-MNC group and the control group (+7.0%, 95%CI 3.6; 10.4) vs. +3.9%, 95%CI -2.1; 10), the absolute increase at 5 years remained stable in the BM-MNC but not in the control group (+7.95%, 95%CI 3.5; 12.4 vs. -0.5%, 95%CI -5.4; 4.4; p for interaction between groups = 0.035). DISCUSSION: In this single-centre, open-labelled study, intracoronary administration of BM-MNC is feasible and safe in the short term. It is also associated with sustained improvement of left ventricular function in patients with acute myocardial infarction, encouraging phase III studies to examine the potential BM-MNC effect on clinical outcome.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt"
Resumo:
Sustained atrial fibrillation (AF) is maintained by sites displaying high dominant frequency (DF). In patients (pts) with long-standing persistent AF (LS-pAF), their spatial distribution and the presence of a left-to-right atrial DF gradient remain poorly known. We hypothesized that the pre-ablation bi-atrial frequency characteristics of LS-pAF pts terminated within the left atrium (LT) are different from that of non terminated (NT) ones. Methods: 23 consecutive pts (59±7y, LS-pAF duration 19±12m) underwent stepwise catheter ablation (step-CA) consisting in pulmonary veins isolation, left atrial (LA) defragmentation, and right atrial (RA) ablations for non terminated AF. A quadripolar catheter (CAT) was placed into the RA appendage (RAA), a decapolar CAT into the coronary sinus (CS) and a duodecapolar CAT into the LA divided into 8 segments. For each segment, 20-sec of bipolar recording was acquired. The DF was defined as the largest peak in the power spectrum (3-15 Hz). The inter-atrial DF gradient was defined as the DF difference between LA and RA appendages. Results: LS-pAF was terminated in 83% (19/23) of the pts: 17 LT, 2 during RA ablation and 4 NT. The figure shows that before ablation bi-atrial DF values of LT pts are significantly lower than that of NT pts for each LA segment as well as for the RAA (p < 0.05). No significant LA-to-RA DF gradient was observed both for LT (0.3±0.5 Hz, p=ns) and NT (0.5±0.03 Hz, p=ns) pts. No significant difference in DF values was observed between LA segments. Conclusions: The lower DF of LT pts is suggestive of a higher organization within both atria compared to NT pts. Our findings suggest that low bi-atrial DF values, but not inter-atrial DF gradient, might be of interest for selecting LS-pAF candidates for sinus rhythm restoration by step-CA.
Resumo:
In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.
Resumo:
Atresia of the coronary sinus (ACS) is a rare congenital anomaly. When associated with persistent left superior vena cava (PLSVC), this defect could have no significant hemodynamic effect, and the patient might remain asymptomatic. However, vascular interventions might induce changes or complications that could show the anomaly. Appropriate management requires a good understanding of this condition. We present the first reported case of ACS and PLSVC occurring after thrombosis of the innominate vein (IV) after central venous catheter placement. The patient presented with atypical subacute chest pain and recurrent extrasystoles. Diagnosis and characterization of vascular anomalies was made by computed tomography phlebography, and the patient was successfully managed by endovascular recanalization of the IV.
Resumo:
Global left ventricular (LV) systolic dysfunction is the strongest predictor of morbidity and mortality in Chagas disease. Echocardiography is considered the gold standard for the detection of LV dysfunction, but not always available in endemic areas where chagasic cardiomyopathy is most common. Brain natriuretic peptide (BNP) is a neurohormone that has been recently described as a simple and inexpensive diagnostic and prognostic marker for patients with congestive heart failure. Chagasic patients (n = 63) and non-infected healthy individuals (n = 18) were recruited prospectively and underwent complete clinical examination, echocardiography and 24-h Holter monitoring. BNP was measured from thawed plasma samples using the Triage BNP test. We observed high levels of BNP in association with depression of LV ejection fraction, with increase of LV end-diastolic diameter and with LV premature complexes. An elevated concentration of BNP, defined as a concentration of 60 pg/ml or more, had a sensitivity of 91.7%, specificity of 82.8%, positive predictive value of 52.4%, and negative predictive value of 98% for detecting LV dysfunction (LV ejection fraction < 40%).BNP measurement using a simple, relatively inexpensive and rapid test has a promising role in identifying LV dysfunction associated with chagasic cardiomyopathy. Equally important, patients with Trypanosoma cruzi infection who have low levels of BNP level in plasma have a very low likelihood of severe cardiac involvement, and echocardiography is probably not necessary.
Resumo:
OBJECTIVE: The aim of this investigation was to improve the hemodynamics during venoarterial bypass by remote decompression of the left ventricle (LV). METHODS: Venoarterial bypass was established in 5 bovine experiments (69+/-10 kg) by the transjugular insertion of a self-expanding cannula (smartcanula) with return through a carotid artery. Cardiogenic shock was simulated with ventricular fibrillation induced by an external stimulator. Left ventricular decompression was achieved by switching to transfemoral drainage of the pulmonary artery (PA) with a long self-expanding cannula. RESULTS: Initial pump flow was 4.7+/-0.9 l/min and the aortic pressure accounted for 75+/-21 mmHg. After induction of ventricular fibrillation, the pump flow dropped after 11+/-8 min to 2.5+/-0.1 l/min. Transfemoral decompression increased the pump flow to 5.6+/-0.7 l/min, while the RV pressure decreased from 27+/-9 to 3+/-5 mmHg, the PA pressure decreased from 29+/-7 to 5+/-4 mmHg, the LV pressure decreased from 29+/-6 to 7+/-2 mmHg, and the aortic pressure increased from 31+/-3 to 47+/-11 mmHg. CONCLUSIONS: Remote drainage of the pulmonary artery during venoarterial bypass allows for effective decompression of the left ventricle and provides superior hemodynamics.