969 resultados para label-retaining


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reliable method of labeling is needed to study dispersal of the braconid parasitoid, Lysiphlebus testaceipes (Cresson), an important biological control of greenbugs, Schizaphis graminum (Rondani), on grain sorghum, Sorghum bicolor (L.) Moench. The feasibility of using aqueous solutions of rubidium chloride (RbCl) applied as a foliar spray or soil drench to label greenbugs and L. testaceipes developing within greenbugs was studied. Laboratory and field studies were conducted to identify the minimal concentration of RbCl to assure labeling of greenbugs and wasps, persistence of Rb throughout the wasp's life span, mobility of Rb to unsprayed sorghum leaves, and feasibility of studying dispersal using a release-recapture technique with Rb-labeled wasps. Both greenbugs and wasps could be labeled using RbCl at concentrations of 2,500-10,000 ppm. Rubidium content in labeled wasps did not significantly vary during the first 7 d after emergence. Greenbugs feeding on unsprayed leaves were labeled up to 4 wk after leaves were sprayed. Rb-labeled wasps were found at the maximum trap distance from the release site (60 m) within 1 d after release.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the optimisation and the analytical performances of a label-free impedimetric immunosensor for the detection of tumour marker CA125 based on gold nanoparticles modified screen-printed graphite electrode. Experimental conditions of each step for the developed immunosensor were studied and optimised. The immunosensor response varied linearly (r2 = 0.996) with antigen concentration between 0 and 100 U/mL. The estimated detection limit was 6.7 U/mL. The electrochemical immunosensor allowed unambiguous identification of CA125, while no significant non-specific signal was detected in the case of all negative controls. The analytical usefulness of the impedimetric immunosensor was finally demonstrated analysing serum samples. © 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. There exists, in particular, a great deal of interest in the correlation between blood serum levels and the severity of risk for cardiovascular disease. A sensitive, label-free, non-amplified and reusable electrochemical impedimetric biosensor for the detection of CRP in blood serum was developed herein based on controlled and coverage optimised antibody immobilization on standard polycrystalline gold electrodes. Charge transfer resistance changes were highly target specific, linear with log. CRP. concentration across a 0.5-50. nM range and associated with a limit of detection of 176. pM. Significantly, the detection limits are better than those of current CRP clinical methods and the assays are potentially cheap, relatively automated, reusable, multiplexed and highly portable. The generated interfaces were capable not only of comfortably quantifying CRP across a clinically relevant range of concentrations but also of doing this in whole blood serum with interfaces that were, subsequently, reusable. The importance of optimising receptor layer resistance in maximising assay sensitivity is also detailed. © 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface confined redox group contributes to an interfacial charging (quantifiable by redox capacitance) that can be sensitively probed by impedance derived capacitance spectroscopy. In generating mixed molecular films comprising such redox groups, together with specific recognition elements (here antibodies), this charging signal is able to sensitively transduce the recognition and binding of specific analytes. This novel transduction method, exemplified here with C-reactive protein, an important biomarker of cardiac status and general trauma, is equally applicable to any suitably prepared interfacial combination of redox reporter and receptor. The assays are label free, ultrasensitive, highly specific and accompanied by a good linear range. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In general, pattern recognition techniques require a high computational burden for learning the discriminating functions that are responsible to separate samples from distinct classes. As such, there are several studies that make effort to employ machine learning algorithms in the context of big data classification problems. The research on this area ranges from Graphics Processing Units-based implementations to mathematical optimizations, being the main drawback of the former approaches to be dependent on the graphic video card. Here, we propose an architecture-independent optimization approach for the optimum-path forest (OPF) classifier, that is designed using a theoretical formulation that relates the minimum spanning tree with the minimum spanning forest generated by the OPF over the training dataset. The experiments have shown that the approach proposed can be faster than the traditional one in five public datasets, being also as accurate as the original OPF. (C) 2014 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we report the development of a sensitive label-free impedimetric biosensor based on the use of affibody as bioreceptor and gold nanostructured screen-printed graphite as a sensor platform for the detection of human epidermal growth factor receptor 2 (HER2). The affisensor is realized by immobilizing a terminal cysteine-modified affibody on gold nanoparticles. The sensor was characterized by electrochemical techniques and scanning electron microscopy (SEM). Furthermore, surface plasmon resonance (SPR) technology was also applied to explore the potential of affibodies as small-molecule discriminating tools. Using optimized experimental conditions, a single-use affisensor showed a good analytical performance for HER2 detection from 0 to 40μg/L. The estimated limit of detection was 6.0μg/L. Finally, the realized affisensor was applied to human serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many rural communities focus their development efforts on job creation. In the non-metropolitan portions of the Northern Great Plains, job creation efforts in the first half of this decade were quite successful. According to the Bureau of Economic Analysis (BEA, 2005), 167 of the 223 non-metropolitan counties in Nebraska, North Dakota and South Dakota saw an actual aggregate increase in total jobs (full and part-time) of 28,734, between the years 2001 and 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

XML similarity evaluation has become a central issue in the database and information communities, its applications ranging over document clustering, version control, data integration and ranked retrieval. Various algorithms for comparing hierarchically structured data, XML documents in particular, have been proposed in the literature. Most of them make use of techniques for finding the edit distance between tree structures, XML documents being commonly modeled as Ordered Labeled Trees. Yet, a thorough investigation of current approaches led us to identify several similarity aspects, i.e., sub-tree related structural and semantic similarities, which are not sufficiently addressed while comparing XML documents. In this paper, we provide an integrated and fine-grained comparison framework to deal with both structural and semantic similarities in XML documents (detecting the occurrences and repetitions of structurally and semantically similar sub-trees), and to allow the end-user to adjust the comparison process according to her requirements. Our framework consists of four main modules for (i) discovering the structural commonalities between sub-trees, (ii) identifying sub-tree semantic resemblances, (iii) computing tree-based edit operations costs, and (iv) computing tree edit distance. Experimental results demonstrate higher comparison accuracy with respect to alternative methods, while timing experiments reflect the impact of semantic similarity on overall system performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metronidazole is a BCS (Biopharmaceutics Classification System) class 1 drug, traditionally considered the choice drug in the infections treatment caused by protozoa and anaerobic microorganisms. This study aimed to evaluate bioequivalence between 2 different marketed 250 mg metronidazole immediate release tablets. A randomized, open-label, 2 x 2 crossover study was performed in healthy Brazilian volunteers under fasting conditions with a 7-day washout period. The formulations were administered as single oral dose and blood was sampled over 48 h. Metronidazole plasma concentrations were determined by a liquid chromatography mass spectrometry (LC-MS/MS) method. The plasma concentration vs. time profile was generated for each volunteer and the pharmacokinetic parameters C-max, T-max, AUC(0-t), AUC(0-infinity), k(e), and t(1/2) were calculated using a noncompartmental model. Bioequivalence between pharmaceutical formulations was determined by calculating 90% CIs (Confidence Intervall) for the ratios of C-max, AUC(0-t), and AUC(0-infinity) values for test and reference using log-transformed data. 22 healthy volunteers (11 men, 11 women; mean (SD) age, 28 (6.5) years [range, 21-45 years]; mean (SD) weight, 66 (9.3) kg [range, 51-81 kg]; mean (SD) height, 169 (6.5) cm [range, 156-186 cm]) were enrolled in and completed the study. The 90% CIs for C-max (0.92-1.06), AUC(0-t) (0.97-1.02), and AUC(0-infinity) (0.97-1.03) values for the test and reference products fitted in the interval of 0.80-1.25 proposed by most regulatory agencies, including the Brazilian agency ANVISA. No clinically significant adverse effects were reported. After pharmacokinetics analysis, it concluded that test 250 mg metronidazole formulation is bioequivalent to the reference product according to the Brazilian agency requirements.