976 resultados para heat load index


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Sweden solar irradiation and space heating loads are unevenly distributed over the year. Domestic hot water loads may be nearly constant. Test results on solar collector performance are often reported as yearly output of a certain collector at fixed temperatures, e g 25, 50 and 75 C. These data are not suitable for dimensioning of solar systems, because the actual performance of the collector depends heavily on solar fraction and load distribution over the year.At higher latitudes it is difficult to attain high solar fractions for buildings, due to overheating in summer and small marginal output for added collector area. Solar collectors with internal reflectors offer possibilities to evade overheating problems and deliver more energy at seasons when the load is higher. There are methods for estimating the yearly angular irradiation distribution, but there is a lack of methods for describing the load and the storage in such a way as to enable optical design of season and load adapted collectors.This report describes two methods for estimation of solar system performance with relevance for season and load adaption. Results regarding attainable solar fractions as a function of collector features, load profiles, load levels and storage characteristics are reported. The first method uses monthly collector output data at fixed temperatures from the simulation program MINSUN for estimating solar fractions for different load profiles and load levels. The load level is defined as estimated yearly collector output at constant collector temperature divided be yearly load. This table may examplify the results:CollectorLoadLoadSolar Improvementtypeprofile levelfractionover flat plateFlat plateDHW 75 %59 %Load adaptedDHW 75 %66 %12 %Flat plateSpace heating 50 %22 %Load adaptedSpace heating 50 %28 %29 %The second method utilises simulations with one-hour timesteps for collectors connected to a simplified storage and a variable load. Collector output, optical and thermal losses, heat overproduction, load level and storage temperature are presented as functions of solar incidence angles. These data are suitable for optical design of load adapted solar collectors. Results for a Stockholm location indicate that a solar combisystem with a solar fraction around 30 % should have collectors that reduce heat production at solar heights above 30 degrees and have optimum efficiency for solar heights between 8 and 30 degrees.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 1999, a 2100 m2 (GFA) two-storey rammed earth building was built on the Thurgoona campus of Charles Sturt University. The climate at Thurgoona is considered Mediterranean – hot dry summers and cool winters. The internal and external walls of the building are constructed from 300-mm thick rammed earth (pise) and are load bearing. The thermal performance of the building has been investigated, both experimentally and theoretically over the summer and winter seasons of 2000/1. As part of these investigations heat flux sensors and thermistors were embedded in one of the external walls of a ground floor office, and data from the transducers has been used to determine the heat flow at the internal and external wall surfaces. The simulation software, TRNSYS, has been used to model the thermal performance of the same office. The programme allows the user to calculate the heat flow at the walls, which define any particular thermal zone. A comparison of measured and predicted values of heat flows and air temperatures has been used to validate the model. The model has then been used to simulate the effect of shading and added insulation on the thermal performance of the external walls in both summer and winter and these results are also presented in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives
The purpose of this study was to investigate the bond strength of apatite layer on titanium (Ti) substrate coated by biomimetic method and to improve the bonding of apatite layer to Ti substrate by optimizing the alkali heat-treatment process.

Methods
Ti plates pre-treated with an alkali solution of 10 M sodium hydroxide (NaOH) were heat-treated at 600 °C for 1 h at different atmospheres: in air and in vacuum. A dense apatite layer formed on top of the sodium titanate layer after soaking the alkali and heat-treated Ti samples in simulated body fluid (SBF) for up to 3 weeks. The bond strengths of the sodium titanate layer on Ti substrate, and apatite layer on the sodium titanate layer, were measured, respectively, by applying a tensile load. The fracture sites were observed with a scanning electron microscope (SEM).

Results
The apatite layer on the substrate after alkali heat-treatment in air achieved higher bond strength than that on the substrate after alkali heat-treatment in vacuum. It was found that the interfacial structure between the sodium titanate and Ti substrate has a significant influence on the bond strength of the apatite layer.

Significance
It is advised that titanium implants can achieve better osseointegration under load-bearing conditions by depositing an apatite layer in vivo on a Ti surface subjected to alkali and heat-treated in air.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Seasonal performance evaluation methods for water heaters are reviewed and an experimental method for rating air-source heat pump water heaters is presented. The rating method is based on measured heat pump performance during heat-up operation of particular products rather than a generic simulation model of heat pump performance. The measured performance is used in a correlation model of the heat pump unit in an annual load-cycle system performance simulation based on the TRNSYS simulation package.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Short-term load forecasting is fundamental for the reliable and efficient operation of power systems. Despite its importance, accurate prediction of loads is problematic and far remote. Often uncertainties significantly degrade performance of load forecasting models. Besides, there is no index available indicating reliability of predicted values. The objective of this study is to construct prediction intervals for future loads instead of forecasting their exact values. The delta technique is applied for constructing prediction intervals for outcomes of neural network models. Some statistical measures are developed for quantitative and comprehensive evaluation of prediction intervals. According to these measures, a new cost function is designed for shortening length of prediction intervals without compromising their coverage probability. Simulated annealing is used for minimization of this cost function and adjustment of neural network parameters. Demonstrated results clearly show that the proposed methods for constructing prediction interval outperforms the traditional delta technique. Besides, it yields prediction intervals that are practically more reliable and useful than exact point predictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Successfully determining competitive optimal schedules for electricity generation intimately hinges on the forecasts of loads. The nonstationarity and high volatility of loads make their accurate prediction somewhat problematic. Presence of uncertainty in data also significantly degrades accuracy of point predictions produced by deterministic load forecasting models. Therefore, operation planning utilizing these predictions will be unreliable. This paper aims at developing prediction intervals rather than producing exact point prediction. Prediction intervals are theatrically more reliable and practical than predicted values. The delta and Bayesian techniques for constructing prediction intervals for forecasted loads are implemented here. To objectively and comprehensively assess quality of constructed prediction intervals, a new index based on length and coverage probability of prediction intervals is developed. In experiments with real data, and through calculation of global statistics, it is shown that neural network point prediction performance is unreliable. In contrast, prediction intervals developed using the delta and Bayesian techniques are satisfactorily narrow, with a high coverage probability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Internal combustion engines release about 1/3 of the energy bound in the fuel as exhaust waste gas energy and another 1/3 energy is wasted through heat transfer into the ambient. On the other hand losses through friction are the third largest root cause for energy loss in internal combustion engines. During city driving frictional losses can be of the same size as the effective work, and during cold start these losses are even bigger. Therefore it is obvious to utilise wasted exhaust energy to warm up the engine oil directly. Frictional losses of any engine can be reduced during part load. Sensitivity analyses have been conducted for different concepts that utilise exhaust energy to reduce engine viscosity and friction. For a new system with an exhaust gas/oil heat exchanger the following benefits have been demonstrated:

• Fuel consumption reductions of over 7% measured as an average over 5 NEDC tests
compared to the standard system configuration.
• Significant reductions in exhaust emissions, mainly CO and NOx have been achieved
• Significantly higher oil temperatures during cold start indicate large potential to
reduce engine wear through reduced water condensation in the crankcase
• Fuel consumption reductions of further 3.3% to 4.6% compared to the 7% measured
over the NEDC test can be expected under real world customer usage conditions at
lower ambient temperatures.

Oil temperature measurements and analysis resulted in the idea of a novel system with further potential to reduce fuel consumption. This Oil Viscosity Energy Recovery System (OVER 7™) consists of 3 key features that add significant synergies if combined in a certain way: an oil warm up circuit/bypass, including oil pressure control and Exhaust Gas/Oil Heat Exchanger. The system separates the thermal inertias of the oil in the engine galleries and the oil pan, reduces hydraulic pumping losses, increases the heat transfer from the cylinder head to the oil, and utilises the exhaust heat to reduce oil friction.

The project demonstrated that sensitivity analysis is an important tool for the evaluation of different concepts. Especially for new concepts that include transient heat transfer such a qualitative approach in combination with accurate experiments and measurements can be faster and more efficient in leading to the desired improvements compared to time consuming detailed simulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study examined if five sessions of short duration (27 min), high intensity, interval training (HIIT) in the heat over a nine day period would induce heat acclimation in Australian football (AF) players. Fourteen professional AF players were matched for VO2peak (mL∙kg-1∙min-1) and randomly allocated into either a heat acclimation (Acc) (n = 7) or Control (Con) group (n = 7). The Acc completed five cycle ergometer HIIT sessions within a nine day period on a cycle ergometer in the heat (38.7 ± 0.5 °C; 34.4 ± 1.3 % RH), whereas Con trained in thermo-neutral conditions (22.3 ± 0.2 °C; 35.8 ± 0. % RH). Four days prior and two days post HIIT participants undertook a 30 min constant load cycling test at 60% V̇O2peak in the heat (37.9 ± 0.1 °C; 28.5 ± 0.7 % RH) during which VO2, blood lactate concentration ([Lac-]), heart rate (HR), rating of perceived exertion (RPE), thermal comfort, core and skin temperatures were measured. Heat acclimation resulted in reduced RPE, thermal comfort and [Lac-] (all p < 0.05) during the submaximal exercise test in the heat. Heart rate was lower (p = 0.007) after HIIT, in both groups. Heat acclimation did not influence any other measured variables. In conclusion, five short duration HIIT sessions in hot dry conditions induced limited heat acclimation responses in AF players during the in-season competition phase. In practice, the heat acclimation protocol can be implemented in a professional team environment; however the physiological adaptations result-ing from such a protocol were limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes the development of an innovative material made from a vegetable polyurethane matrix and load of industrial waste, from retread tires, for thermal insulation and environmental comfort. Experimental procedures are presented, as well as the results of the thermal and acoustic performance of this composite material, made from an expansive foam derived from the castor seed oil and fiber of scrap tires. The residue was treated superficially with sodium hydroxide, to eliminate contaminants, and characterized macroscopically and microscopically. Samples were produced with addition of residues at levels of 5%, 10%, 15% and 20% by weight, for determination of thermal properties: conductivity, heat capacity and thermal diffusivity, sound absortion index and density. The results were compared to commercially available thermal insulation and sound absorbing products. According to the analysis of results, it was concluded that the developed composite presents characteristics that qualify it as a thermal insulation with superior performance, compared to commercial available insulation, and sound absorption capacity greater than the castor oil polyurethane s, without addition of the residue

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of mean values of thermal and electric demand can be justifiable for synthesising the configuration and for estimating the economic results because it simplifies the analysis in a preliminary feasibility study of a cogeneration plant. For determining the cogeneration scheme that best fits the energetic needs of a process several cycles and combinations must be considered, and those technically feasible will be analysed according to economic models. Although interesting for a first approach, this procedure do not consider that the peaks and valleys present in the load patterns will impose additional constraints relatively to the equipment capacities. In this paper, the effects of thermal and electric load fluctuation to the cogeneration plant design were considered. An approach for modelling these load variability is proposed for comparing two competing thermal and electric parity competing schemes. A gas turbine associated to a heat recovery steam generator was then proposed and analysed for thermal- and electric-following operational strategies. Thermal-following option revealed to be more attractive for the technical and economic limits defined for this analysis. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this paper is to present a generalized analytical-numerical model of the internal flow in heat pipes. The model formulation is based on two-dimensional formulation of the energy and momentum equations in the vapour and liquid regions and also in the metallic tube. The numerical solution of the model is obtained by using the descretization scheme LOAD and the SIMPLE numerical code. The flow fields, as well as the pressure fields, for different geometries were obtained and discussed. Copyright © 1996 Elsevier Science Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Response surface methodology was used to establish a relationship between total solids content, milk base, heat treatment temperature, and sample temperature, and consistency index, flow behaviour index, and apparent viscosity of plain stirred yogurts. Statistical treatments resulted in developments of mathematical models. All samples presented shear thinning fluid behaviour. The increase of the content of total solids (9.3-22.7 %) and milk base heat treatment temperature (81.6-98.4°C) resulted in a significant increase in consistency index and a decrease in flow behaviour index. Increase in the sample temperature (1.6-18.4°C) caused a decrease in consistency index and increase in flow behaviour index. Apparent viscosity was directly related to the content of total solids. Rheological properties of yogurt were highly dependent on the content of total solids in milk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Unbalance and harmonics are two major distortions in the three-phase distribution systems. In this paper an investigation into unbalance phenomena in the distribution networks using instantaneous space vector theory, is presented. Power oscillation index (POI) and effective power factor (PFe) are calculated in the network nodes for several unbalance loading conditions. For system analysis a general power flow algorithm for three-phase four-wire radial distribution networks, based on backward-forward technique, is applied. Results obtained from several case studies using medium and low voltage test feeder with unbalanced load, are presented and discussed. © 2010 Praise Worthy Prize S.r.l. - All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a methodology for optimized allocation of switches for automatic load transfer in distribution systems in order to improve the reliability indexes by restoring such systems which present voltage classes of 23 to 35 kV and radial topology. The automatic switches must be allocated on the system in order to transfer load remotely among the sources at the substations. The problem of switch allocation is formulated as nonlinear constrained mixed integer programming model subject to a set of economical and physical constraints. A dedicated Tabu Search (TS) algorithm is proposed to solve this model. The proposed methodology is tested for a large real-life distribution system. © 2011 IEEE.