907 resultados para energy-efficient
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e Computadores
Resumo:
The use of thermal insulation materials for the achievement of energy efficient buildings intended, in most cases, the fulfilment of the required heating and cooling needs of the operational phase. The main goal of this paper is â by using exploratory methodology, namely literature review â identify more sustainable insulating materials and, concomitantly, exposing the paradoxical effect of other insulation materials with high Global Warming Potential (GWP) highlighting the role of the Life Cycle Assessment (LCA), Ecodesign and Environmental Product Declaration (EPD) tools for the framing, comparison and selection of materials. As a main conclusion, it is noticed the lack of environmental information from the producers which, together with acquisition prices that do not internalize Life Cycle Costs (LCC), has led to the use of insulation materials with high carbon footprint and to the "isolation paradox" as well.
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores
Resumo:
Aromatic amines are widely used industrial chemicals as their major sources in the environment include several chemical industry sectors such as oil refining, synthetic polymers, dyes, adhesives, rubbers, perfume, pharmaceuticals, pesticides and explosives. They result also from diesel exhaust, combustion of wood chips and rubber and tobacco smoke. Some types of aromatic amines are generated during cooking, special grilled meat and fish, as well. The intensive use and production of these compounds explains its occurrence in the environment such as in air, water and soil, thereby creating a potential for human exposure. Since aromatic amines are potential carcinogenic and toxic agents, they constitute an important class of environmental pollutants of enormous concern, which efficient removal is a crucial task for researchers, so several methods have been investigated and applied. In this chapter the types and general properties of aromatic amine compounds are reviewed. As aromatic amines are continuously entering the environment from various sources and have been designated as high priority pollutants, their presence in the environment must be monitored at concentration levels lower than 30 mg L1, compatible with the limits allowed by the regulations. Consequently, most relevant analytical methods to detect the aromatic amines composition in environmental matrices, and for monitoring their degradation, are essential and will be presented. Those include Spectroscopy, namely UV/visible and Fourier Transform Infrared Spectroscopy (FTIR); Chromatography, in particular Thin Layer (TLC), High Performance Liquid (HPLC) and Gas chromatography (GC); Capillary electrophoresis (CE); Mass spectrometry (MS) and combination of different methods including GC-MS, HPLC-MS and CE-MS. Choosing the best methods depend on their availability, costs, detection limit and sample concentration, which sometimes need to be concentrate or pretreated. However, combined methods may give more complete results based on the complementary information. The environmental impact, toxicity and carcinogenicity of many aromatic amines have been reported and are emphasized in this chapter too. Lately, the conventional aromatic amines degradation and the alternative biodegradation processes are highlighted. Parameters affecting biodegradation, role of different electron acceptors in aerobic and anaerobic biodegradation and kinetics are discussed. Conventional processes including extraction, adsorption onto activated carbon, chemical oxidation, advanced oxidation, electrochemical techniques and irradiation suffer from drawbacks including high costs, formation of hazardous by-products and low efficiency. Biological processes, taking advantage of the naturally processes occurring in environment, have been developed and tested, proved as an economic, energy efficient and environmentally feasible alternative. Aerobic biodegradation is one of the most promising techniques for aromatic amines remediation, but has the drawback of aromatic amines autooxidation once they are exposed to oxygen, instead of their degradation. Higher costs, especially due to power consumption for aeration, can also limit its application. Anaerobic degradation technology is the novel path for treatment of a wide variety of aromatic amines, including industrial wastewater, and will be discussed. However, some are difficult to degrade under anaerobic conditions and, thus, other electron acceptors such as nitrate, iron, sulphate, manganese and carbonate have, alternatively, been tested.
Resumo:
This thesis investigates the challenges of establishing the electric vehicle (EV) in Ireland and how the Irish government and industry are trying to meet them. It further seeks to provide information on Irish consumers’ attitudes towards the electric vehicle and their willingness to purchase it. The review of the literature showed that the Irish government is investing significant funds in trying to establish the market for the electric vehicle and position itself as a world leader in adopting the electric vehicle. The EV will also have an important role to play in how Ireland meets its targets for CO2 reductions towards 2020. Climate change and use of fossil fuels are driving the need for increased use of renewable energy and increased energy independence while reducing the greenhouse gas emissions that are the leading cause of climate change. The transport sector is almost completely dependent on the use of fossil fuel and resultantly is one of the largest sources of these GHG emissions. These issues are leading to the design and production of more energy efficient and environmentally friendly vehicles. The ultimate goal is to achieve a zero emissions vehicle. The electric vehicle is presently the only vehicle being mass produced that has the potential to be zero emissions. There are however issues that customers may not be willing to overlook such as the lower range of the vehicle and the length of time it takes to recharge. Vehicle cost is also an important issue that customers may not overlook. Knowing what the consumer’s attitudes are towards the EV and their willingness to purchase them is important as these new vehicles begin to appear in the showrooms. The consumers will be vital to how successful this market becomes. Using an online questionnaire methodology, in a sample of 118 consumers, the major conclusion to be drawn from the research is that the vehicle price, the convenience to recharge and vehicle range were the three most essential issues for the consumers if they were purchasing an EV. The success of the electric vehicle market may depend on what measures are taken to overcome them.
Resumo:
In Ireland the average energy cost for a household in 2006 was estimated to be €1,767, an increase of 4% on 2005 figures. With the state o f the current economic climate, home owners are beginning to realise the potential of energy efficient construction methods. The Passive House Standard offers a cost efficient and sustainable construction solution compared to the Traditional Irish construction methods. This report focuses on the Cost comparison between Passive House construction and traditional construction methods. The report also focuses on barriers that are slowing market penetration of the Passive House standard in the Irish Market. It also identifies potential energy savings that passive house occupants would benefit from. The report also highlights professional opinions on the future development o f the Passive House Standard in Ireland. The conclusions of this report are that the Passive House Standard is a more financially suitable construction solution compared to that o f a traditional dwelling complying with the Irish Building Regulations. The report also concludes that the Passive House Standard won’t be introduced as an Irish Building Regulation in the future but that it will have a big impact on future building regulations. The hypothesis o f this report is supported by data obtained from a literature review, qualitative data analysis and a case study. The report recommends that in order for the Passive House Standard to penetrate further into the Irish construction market, various barriers must be rectified. Local manufactures must start producing suitable components that suit the Passive House specification. The Building Energy Rating system must be altered in order for the Passive House to achieve its potential BER rating.
Resumo:
In this work, energy concepts for two completely different properties are sought. The first property is a deconstruction of an apartment building with 26 residential units on two separate buildings with 6 residential units. The energy concepts should enable an energy efficient house and allow options for renewable fuels. The second property includes four buildings which are supplied with fuel oil. A change to use natural gas is planned and wherever possible CHP technology for highly efficient use of energy.
Resumo:
Some years ago, a parish in Geneva decided to reduce heating costs by insulating its church to make it more energy efficient. Three years after the last renovations, it was observed that the internal surfaces of the naves had already become dusty compared with the customary frequency of 10-12 years. Dust even deposited on various surfaces during religious services. Our investigation showed that nearly all the dust found inside the church may in fact be soot from incense and candle combustion. Incense appears to be a significant source of polycyclic aromatic hydrocarbons. With a mechanical ventilation system and petrol lamps resembling candles the problem can be resolved.
Resumo:
The Weatherization Assistance Program is a low-income energy efficiency program administered by the Department of Energy (DOE). Its purpose is to make the homes of low-income clients more energy efficient, thereby reducing the households’ energy bills. The program also improves the health and safety of low-income homes. The energy efficiency and health and safety work is done using the most advanced technologies and testing protocols available in the housing industry. States administer the program in accordance with DOE rules and regulations.
Resumo:
If you haven’t been in the market for new appliances during the past several years, you’re going to be surprised at how innovative and energy-efficient appliances have become. You’ll find energy-smart appliance choices in almost all price ranges. Before heading to the local appliance retailer or “big-box” store, measure the space the new appliance will occupy to make sure it will fit—and that there’s enough room to fully open the door (or lid), as well as adequate clearances for ventilation, plumbing connections and other hookups. Then go to the appliance manufacturers’ Web sites to look at product information, and make a list of questions and “must-have” and “nice-to-have-but-not-essential” features.
Resumo:
Summary : With regard to exercise metabolism, lactate was long considered as a dead-end waste product responsible for muscle fatigue and a limiting factor for motor performance. However, a large body of evidence clearly indicates that lactate is an energy efficient metabolite able to link the glycolytic pathway with aerobic metabolism and has endocrine-like actions, rather than to be a dead-end waste product. Lactate metabolism is also known to be quickly upregulated by regular endurance training and is thought to be related to exercise performance. However, to what extent its modulation can increase exercise performance in already endurance-trained subjects is unknown. The general hypothesis of this work was therefore that increasing either lactate metabolic clearance rate or lactate availability could, in turn, increase endurance performance. The first study (Study I) aimed at increasing the lactate clearance rate by means of assumed interaction effects of endurance training and hypoxia on lactate metabolism and endurance performance. Although this study did not demonstrate any interaction of training and hypoxia on both lactate metabolism and endurance performance, a significant deleterious effect of endurance training in hypoxia was shown on glucose homeostasis. The methods used to determine lactate kinetics during exercise exhibited some limitations, and the second study did delineate some of the issues raised (Study 2). The third study (Study 3) investigated the metabolic and performance effects of increasing plasma lactate production and availability during prolonged exercise in the fed state. A nutritional intervention was used for this purpose: part of glucose feedings ingested during the control condition was substituted by fructose. The results of this study showed a significant increase of lactate turnover rate, quantified the metabolic fate of fructose; and demonstrated a significant decrease of lipid oxidation and glycogen breakdown. In contrast, endurance performance appeared to be unmodified by this dietary intervention, being at odds with recent reports. Altogether the results of this thesis suggest that in endurance athletes the relationship between endurance performance and lactate turnover rate remains unclear. Nonetheless, the result of the present study raises questions and opens perspectives on the rationale of using hypoxia as a therapeutic aid for the treatment of insulin resistance. Moreover, the results of the second study open perspectives on the role of lactate as an intermediate metabolite and its modulatory effects on substrate metabolism during exercise. Additionally it is suggested that the simple nutritional intervention used in the third study can be of interest in the investigation on the aforementioned roles of lactate. Résumé : Lorsque le lactate est évoqué en rapport avec l'exercice, il est souvent considéré comme un déchet métabolique responsable de l'acidose métabolique, de la fatigue musculaire ou encore comme un facteur limitant de la performance. Or la littérature montre clairement que le lactate se révèle être plutôt un métabolite utilisé efficacement par de nombreux tissus par les voies oxydatives et, ainsi, il peut être considéré comme un lien entre le métabolisme glycolytique et le métabolisme oxydatif. De plus on lui prête des propriétés endocrines. Il est connu que l'entraînement d'endurance accroît rapidement le métabolisme du lactate, et il est suggéré que la performance d'endurance est liée à son métabolisme. Toutefois la relation entre le taux de renouvellement du lactate et la performance d'endurance est peu claire, et, de même, de quelle manière la modulation de son métabolisme peut influencer cette dernière. Le but de cette thèse était en conséquence d'investiguer de quelle manière et à quel degré l'augmentation du métabolisme du lactate, par l'augmentation de sa clearance et de son turnover, pouvait à son tour améliorer la performance d'endurance de sujets entraînés. L'objectif de la première étude a été d'augmenter la clearance du lactate par le biais d'un entraînement en conditions hypoxiques chez des cyclistes d'endurance. Basé sur la littérature scientifique existante, on a fait l'hypothèse que l'entraînement d'endurance et l'hypoxie exerceraient un effet synergétique sur le métabolisme du lactate et sur la performance, ce qui permettrait de montrer des relations entre performance et métabolisme du lactate. Les résultats de cette étude n'ont montré aucun effet synergique sur la performance ou le métabolisme du lactate. Toutefois, un effet délétère sur le métabolisme du glucose a été démontré. Quelques limitations de la méthode employée pour la mesure du métabolisme du lactate ont été soulevées, et partiellement résolues dans la seconde étude de ce travail, qui avait pour but d'évaluer la sensibilité du modèle pharmacodynamique utilisé pour le calcul du turnover du lactate. La troisième étude a investigué l'effet d'une augmentation de la lactatémie sur le métabolisme des substrats et sur la performance par une intervention nutritionnelle substituant une partie de glucose ingéré pendant l'exercice par du fructose. Les résultats montrent que les composants dynamiques du métabolisme du lactate sont significativement augmentés en présence de fructose, et que les oxydations de graisse et de glycogène sont significativement diminuées. Toutefois aucun effet sur la performance n'a été démontré. Les résultats de ces études montrent que la relation entre le métabolisme du lactate et la performance reste peu claire. Les résultats délétères de la première étude laissent envisager des pistes de travail, étant donné que l'entraînement en hypoxie est considéré comme outil thérapeutique dans le traitement de pathologies liées à la résistance à l'insuline. De plus les résultats de la troisième étude ouvrent des perspectives de travail quant au rôle du lactate comme intermédiaire métabolique durant l'exercice ainsi que sur ses effets directs sur le métabolisme. Ils suggèrent de plus que la manipulation nutritionnelle simple qui a été utilisée se révèle être un outil prometteur dans l'étude des rôles et effets métaboliques que peut revêtir le lactate durant l'exercice.
Resumo:
Biofuels are considered as a promising substitute for fossil fuels when considering the possible reduction of greenhouse gases emissions. However limiting their impacts on potential benefits for reducing climate change is shortsighted. Global sustainability assessments are necessary to determine the sustainability of supply chains. We propose a new global criterion based framework enabling a comprehensive international comparison of bioethanol supply chains. The interest of this framework is that the selection of the sustainability indicators is qualified on three criterions: relevance, reliability and adaptability to the local context. Sustainability issues have been handled along environmental, social and economical issues. This new framework has been applied for a specific issue: from a Swiss perspective, is locally produced bioethanol in Switzerland more sustainable than imported from Brazil? Thanks to this framework integrating local context in its indicator definition, Brazilian production of bioethanol is shown as energy efficient and economically interesting for Brazil. From a strictly economic point of view, bioethanol production within Switzerland is not justified for Swiss consumption and questionable for the environmental issue. The social dimension is delicate to assess due to the lack of reliable data and is strongly linked to the agricultural policy in both countries. There is a need of establishing minimum sustainability criteria for imported bioethanol to avoid unwanted negative or leakage effects.
Resumo:
The potential for application of silicon nitride-based light sources to general lighting is reported. The mechanism of current injection and transport in silicon nitride layers and silicon oxide tunnel layers is determined by electro-optical characterization of both bi- and tri-layers. It is shown that red luminescence is due to bipolar injection by direct tunneling, whereas Poole-Frenkel ionization is responsible for blue-green emission. The emission appears warm white to the eye, and the technology has potential for large-area lighting devices. A photometric study, including color rendering, color quality and luminous efficacy of radiation, measured under various AC excitation conditions, is given for a spectrum deemed promising for lighting. A correlated color temperature of 4800K was obtained using a 35% duty cycle of the AC excitation signal. Under these conditions, values for general color rendering index of 93 and luminous efficacy of radiation of 112 lm/W are demonstrated. This proof of concept demonstrates that mature silicon technology, which is extendable to lowcost, large-area lamps, can be used for general lighting purposes. Once the external quantum efficiency is improved to exceed 10%, this technique could be competitive with other energy-efficient solid-state lighting options. ©2011 Optical Society of America OCIS codes: (230.2090) Electro-optical devices; (150.2950) Illumination.
Resumo:
Every year, a typical family in the United States spends around half of its home energy budget on heating and cooling. In Iowa, that percentage can be higher, due to temperature extremes reached during the winter and summer months. Unfortunately, many of those dollars often are wasted, because conditioned air escapes through leaky ceilings, walls and foundations—or flows through inadequately insulated attics, exterior walls and basements. In addition, many heating systems and air conditioners aren’t properly maintained or are more than 10 years old and very inefficient, compared to models being sold today. As a result, it makes sense to analyze your home as a collection of systems that must work together in order to achieve peak energy savings. For example, you won’t get anywhere near the savings you’re expecting from a new furnace if your airhandling ducts are uninsulated and leak at every joint. The most energy-efficient central air-conditioning setup won’t perform to your expectations if your attic insulation is inadequate and can’t reduce solar heat gain to help keep your home cool. And planting the wrong types of trees or shrubs close to your home adversely can affect potential energy savings all year long.
Resumo:
If you haven’t been in the market for new appliances during the past several years, you’re going to be surprised at how innovative and energy-efficient appliances have become. You’ll find energy-smart appliance choices in almost all price ranges. Before heading to the local appliance retailer or “big-box” store, measure the space the new appliance will occupy to make sure it will fit—and that there’s enough room to fully open the door (or lid), as well as adequate clearances for ventilation, plumbing connections and other hookups. Then go to the appliance manufacturers’ Web sites to look at product information, and make a list of questions and “must-have” and “nice-to-have-but-not-essential” features.