968 resultados para endoscopic ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound scans in the mid-trimester of pregnancy are now a routine part of antenatal care in most European countries. Using data from registries of congenital anomalies a study was undertaken in Europe. The objective of the study was to evaluate prenatal detection of cleft lip with or without cleft palate (CL(P)) and cleft palate (CP). All CL(P) and CPs suspected prenatally and identified at birth in the period 1996-98 were registered from 20 Congenital Malformation Registers from the following European countries: Austria, Croatia, Denmark, France, Germany, Italy, Lithuania, Spain, Switzerland, The Netherlands, UK, Ukraine. These registries followed the same methodology. A total of 709,027 births were covered; 7758 cases with congenital malformations were registered. Included in the study were 751 cases reported with facial clefts: 553 CL(P) and 198 CP. The prenatal diagnosis by transabdominal ultrasound of CL(P) was made in 65/366 cases with an isolated malformation, in 32/62 cases with chromosomal anomaly, in 30/89 cases with multiple malformations and in 21/36 syndromic cases. The prenatal diagnosis of CP was made in 13/198 cases. One hundred pregnancies were terminated (13%); in 97 of these the cleft was associated with other malformations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Transanal endoscopic microsurgery provides a minimally invasive alternative to radical surgery for excision of benign and malignant rectal tumors. The purpose of this study was to review our experience with transanal endoscopic microsurgery to clarify its role in the treatment of different types of rectal pathology. METHODS: A prospective database documented all patients undergoing transanal endoscopic microsurgery from October 1996 through June 2008. We analyzed patient and operative factors, complications, and tumor recurrence. For recurrence analysis, we excluded patients with fewer than 6 months of follow-up, previous excisions, known metastases at initial presentation, and those who underwent immediate radical resection following transanal endoscopic microsurgery. RESULTS: Two hundred sixty-nine patients underwent transanal endoscopic microsurgery for benign (n = 158) and malignant (n = 111) tumors. Procedure-related complications (21%) included urinary retention (10.8%), fecal incontinence (4.1%), fever (3.8%), suture line dehiscence (1.5%), and bleeding (1.5%). Local recurrence rates for 121 benign and 83 malignant tumors were 5% for adenomas, 9.8% for T1 adenocarcinoma, 23.5% for T2 adenocarcinoma, 100% for T3 adenocarcinoma, and 0% for carcinoid tumors. All 6 (100%) recurrent adenomas were retreated with endoscopic techniques, and 8 of 17 (47%) recurrent adenocarcinomas underwent salvage procedures with curative intent. CONCLUSIONS: Transanal endoscopic microsurgery is a safe and effective method for excision of benign and malignant rectal tumors. Transanal endoscopic microsurgery can be offered for (1) curative resection of benign tumors, carcinoid tumors, and select T1 adenocarcinomas, (2) histopathologic staging in indeterminate cases, and (3) palliative resection in patients medically unfit or unwilling to undergo radical resection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the current effectiveness of routine prenatal ultrasound screening in detecting gastroschisis and omphalocele in Europe. DESIGN: Data were collected by 19 congenital malformation registries from 11 European countries. The registries used the same epidemiological methodology and registration system. The study period was 30 months (July 1st 1996-December 31st 1998) and the total number of monitored pregnancies was 690,123. RESULTS: The sensitivity of antenatal ultrasound examination in detecting omphalocele was 75% (103/137). The mean gestational age at the first detection of an anomaly was 18 +/- 6.0 gestational weeks. The overall prenatal detection rate for gastroschisis was 83% (88/106) and the mean gestational age at diagnosis was 20 +/- 7.0 gestational weeks. Detection rates varied between registries from 25 to 100% for omphalocele and from 18 to 100% for gastroschisis. Of the 137 cases of omphalocele less than half of the cases were live births (n = 56; 41%). A high number of cases resulted in fetal deaths (n = 30; 22%) and termination of pregnancy (n = 51; 37%). Of the 106 cases of gastroschisis there were 62 (59%) live births, 13 (12%) ended with intrauterine fetal death and 31 (29%) had the pregnancies terminated. CONCLUSIONS: There is significant regional variation in detection rates in Europe reflecting different policies, equipment and the operators' experience. A high proportion of abdominal wall defects is associated with concurrent malformations, syndromes or chromosomal abnormalities, stressing the need for the introduction of repeated detailed ultrasound examination as a standard procedure. There is still a relatively high rate of elective termination of pregnancies for both defects, even in isolated cases which generally have a good prognosis after surgical repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called 'virtual CT' to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland-Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (-0.22-0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the maximum temperature elevation in the phantom (7% relative drop). Without any correction, the maximum temperature was down 6 °C (43% relative drop). We have developed an approach that allows for a reconstruction of a virtual CT dataset from MRI to perform phase correction in TcMRgFUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate morphological and perfusion changes in liver metastases of neuroendocrine tumours by contrast-enhanced ultrasound (CEUS) after transarterial embolisation with bead block (TAE) or trans-arterial chemoembolisation with doxorubicin-eluting beads (DEB-TACE). METHODS: In this retrospective study, seven patients underwent TAE, and ten underwent DEB-TACE using beads of the same size. At 1 day before embolisation, 2 days, 1 month and 3 months after the procedure, a destruction-replenishment study using CEUS was performed with a microbubble-enhancing contrast material on a reference tumour. Relative blood flow (rBF) and relative blood volume (rBV) were obtained from the ratio of values obtained in the tumour and in adjacent liver parenchyma. Morphological parameters such as the tumour's major diameter and the viable tumour's major diameter were also measured. A parameter combining functional and morphological data, the tumour vitality index (TVI), was studied. The Wilcoxon rank-sum test and Fisher's test were used to compare treatment groups. RESULTS: At 3 months rBF, rBV and TVI were significantly lower (P = 0.005, P = 0.04 and P = 0.03) for the group with doxorubicin. No difference in morphological parameters was found throughout the follow-up. CONCLUSIONS: One parameter, TVI, could evaluate the morphological and functional response to treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As an emerging alternative to DXA, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non invasive assessment of fracture risk in the management of osteoporosis. While the potential of QUS in the management of osteoporosis have been highly recognized by the scientific community and granted by the majority of the international bone disease organizations, it becomes important to develop strategies how to use ultrasound clinically. Our paper is highlighting Swiss operational clinical propositions for 2 QUS devices sold in Switzerland, on how to use the QUS in the management of osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This prospective study compares repetitive thick-slab single-shot projection magnetic resonance cholangiopancreatography (MRCP) with endoscopic ultrasonography (EUS) for the detection of choledocholithiasis. Fifty-seven consecutive patients (36 women, mean age 61) referred for suspected choledocholithiasis underwent MRCP, followed by EUS. Each procedure was performed by different operators blinded to the results of the other investigation. MR technique included a turbo spin-echo T2-weighted axial sequence with selective fat saturation (SPIR/TSE, TE=70 ms, TR=1,600 ms), followed by coronal dynamic MRCP. The same thick-slab slice was sequentially acquired 12 times as breath-hold single-shot projection imaging (SSh, TE=900 ms, TE=8,000 ms) centred on the common bile duct (CBD). Two experienced radiologists independently and blindly evaluated MR images for the detection of CBD stones. Their inter-observer agreement kappa was determined. Secondly, the two observers read MR images in consensus again. CBD stones were demonstrated in 18 out of 57 patients (31.6 %) and confirmed by endoscopic retrograde cholangiography (ERCP, n=17) or intraoperative cholangiography (n=1). Clinical follow-up served as the "gold standard" in patients with negative results without following invasive procedure (n=28). Sensitivity, specificity, accuracy, positive and negative predictive value for MRCP resulting from consensus reading were 94.9%, 94.4%, 94.7%, 97.4% and 89.5%, respectively. Corresponding values of EUS were 97.4%, 94.4%, 96.5%, 97.4% and 94.4%. Inter-observer agreement kappa was 0.81. Repetitive thick-slab single-shot projection MRCP is an accurate non-invasive imaging modality for suspected choledocholithiasis and should be increasingly used to select those patients who require a subsequent therapeutic procedure, namely ERCP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess reproducibility and feasibility of amusculoskeletal ultrasound (US) score for rheumatoid arthritis amongrheumatologist with diverse expertise in US, working in private orhospital practice.Methods: The Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a semi-quantitative score for RA usingOMERACT criteria for synovitis and erosion. The score was taught torheumatologists trained in US through two workshops. Subsequently,they were encouraged to practice in their office. For the study, we used6 US machines of different quality, each with a different patient.19 readers randomly selected among rheumatologists who haveattended both workshops, were asked to score anonymously at leastone patient. To assess whether some factors influence the score, weasked each reader to answer questionnaire describing his experiencewith US.Results: 19 rheumatologists have performed 29 scans, each patienthaving been evaluated by 4 to 6 readers. Median time for examcompletion was 20 minutes (range 15 to 60 mn). 53% ofrheumatologists work in private practice. Graph 1 show the global greyscale score for each patient. Weighted kappa was calculated for eachpair of reader using stata11. Almost all kappa of poor agreement wereobtained with a low quality device or by an assessor who havepreviously performed less than 5 scores himself.Conclusions: This is the first study to show an US score for RAfeasible by rheumatologists with diverse expertise in US both in privateand hospital practice. Reproducibility seemed to be influenced by thequality of device and previous experience with the score.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using different bacteriological (urease test, Gram staining and culture) and histological (Steiner staining and modified Giemsa staining) techniques, we searched for the presence of Helicobacter pylori in the gastric antrum of 200 dyspeptic Brazilian patients (106 females and 94 males aged 19 days to 81 years). The presence of bacteria was then correlated with the endoscopic and histological findings. H. pylori was present in 59.5 of the population studied. In Brazil, colonization occurs early, involving 37 of the dyspeptic population by 20 years of age. The presence of H. pylori in the gastric antrum was strongly associated with duodenal ulcer (P < 0.001) and a normal endoscopic examination did not exclude the possibility of colonization of the gastric antrum by H. pylori. The most sensitive test was the preformed urease test (89). We conclude that more than one diagnostic method should preferably be used for the detection of H. pylori and that the presence of H. pylori is closely correlated with active chronic gastritis (P < 0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibrin sealing has recently evolved as a new technique for mesh fixation in endoscopic inguinal hernia repair. A comprehensive Medline search was carried out evaluating fibrin sealant for mesh fixation, and finally 12 studies were included (3 randomized trials, 3 nonrandomized trials, and 6 case series). The trials were assessed for operative time, seroma formation, recovery time, recurrence rate, and acute and chronic pain.There was a trend toward decreased operative times for fibrin sealing compared with mechanical stapling; however, the results for seroma formation remained contradictory. The most important finding was the reduced postoperative pain. Recovery times were lower after fibrin sealing and the recurrence rates showed no differences.Fibrin sealing for mesh fixation in the endoscopic inguinal hernia surgery is a promising alternative to mechanical stapling, which can be safely applied. As the overall quality of published data remains poor, further well-designed studies are needed until fibrin sealing can replace mechanical stapling as a new standard for mesh fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mucosal healing in ulcerative colitis (UC) is reported to be associated with favourable clinical outcomes such as reduced hospitalization and surgery rates. Activity monitoring by endoscopy has its shortcomings due to invasiveness, costs, and potential patient discomfort. Data on the correlation of noninvasive biomarkers with endoscopic severity in UC are scarce. Aim: to evaluate the correlation between endoscopic activity according to the modified Baron Index and fecal calprotectin, C-reactive protein (CRP), blood leukocytes, and the Lichtiger Index (clinical score). Methods: UC patients with leftsided and extensive colitis undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically. Fecal and blood samples were analyzed in UC patients (in a blinded fashion) and controls. The modified Baron score describes the following 5 endoscopic conditions: 0 = normal, 1 = granular mucosa, edema, 2 = friable mucosa but no spontaneous bleeding, 3 = microulcerations with spontaneous bleeding, 4 = gross ulceration, denuded mucosa. Results: We enrolled 228 UC patients (mean age 41 ± 13 years, 39 female) and 52 healthy controls. Disease was located in 40% in the left colon, 21% had an extensive and 39% a pancolitis. Endoscopic disease activity correlated best with fecal calprotectin (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), and blood leukocytes (r = 0.401). Fecal calprotectin was the only marker that could discriminate between different grades of endoscopic activity (grade 0, 25 ± 11 μg/g; grade 1, 44 ± 34 μg/g; grade 2, 111 ± 74 μg/g; grade 3, 330 ± 332 μg/g; grade 4, 659 ± 319 μg/g; P = 0.002 for discriminating grade 0 vs. 1, and P < 0.001 for discriminating grade 1 vs. 2, grade 2 vs. 3, and grade 3 vs. 4). Fecal calprotectin had the highest overall accuracy (91%) to detect endoscopically active disease (modified Baron Index ≥ 2), followed by the Lichtiger Index score of ≥ 4 (77%), CRP > 5 mg/L (69%) and blood leukocytosis (58%). Conclusions: Fecal calprotectin better correlated with endoscopic disease activity than clinical activity, CRP, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative ultrasound (QUS) appears to be developing into an acceptable, low-cost and readily-accessible alternative to dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD) in the detection and management of osteoporosis. Perhaps the major difficulty with their widespread use is that many different QUS devices exist that differ substantially from each other, in terms of the parameters they measure and the strength of empirical evidence supporting their use. But another problem is that virtually no data exist outside of Caucasian or Asian populations. In general, heel QUS appears to be most tested and most effective. Some, but not all heel QUS devices are effective assessing fracture risk in some, but not all populations, the evidence being strongest for Caucasian females > 55 years old, though some evidence exists for Asian females > 55 and for Caucasian and Asian males > 70. Certain devices may allow to estimate the likelihood of osteoporosis, but very limited evidence exists supporting QUS use during the initiation or monitoring of osteoporosis treatment. Likely, QUS is most effective when combined with an assessment of clinical risk factors (CRF); with DXA reserved for individuals who are not identified as either high or low risk using QUS and CRF. However, monitoring and maintenance of test and instrument accuracy, precision and reproducibility are essential if QUS devices are to be used in clinical practice; and further scientific research in non-Caucasian, non-Asian populations clearly is compulsory to validate this tool for more widespread use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound segmentation is a challenging problem due to the inherent speckle and some artifacts like shadows, attenuation and signal dropout. Existing methods need to include strong priors like shape priors or analytical intensity models to succeed in the segmentation. However, such priors tend to limit these methods to a specific target or imaging settings, and they are not always applicable to pathological cases. This work introduces a semi-supervised segmentation framework for ultrasound imaging that alleviates the limitation of fully automatic segmentation, that is, it is applicable to any kind of target and imaging settings. Our methodology uses a graph of image patches to represent the ultrasound image and user-assisted initialization with labels, which acts as soft priors. The segmentation problem is formulated as a continuous minimum cut problem and solved with an efficient optimization algorithm. We validate our segmentation framework on clinical ultrasound imaging (prostate, fetus, and tumors of the liver and eye). We obtain high similarity agreement with the ground truth provided by medical expert delineations in all applications (94% DICE values in average) and the proposed algorithm performs favorably with the literature.