986 resultados para display


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoinduced anisotropy of a photochromic pyrrylfulgide/PMMA film was investigated by using two linearly polarized beams. Excitation by linearly polarized light induces into the film an optical axis that has the same polarization as the excitation beam. This causes a change of the transmittance and of the polarization state of the detection beam. With a microscope a matrix of 4x4 light spots with different polarizations were recorded in the pyrrylfulgide/PMMA film. If readout with non-polarized light, the matrix of light spots show no information pattern. However, when readout with differently polarized lights, different patterns can be displayed. The experiment demonstrates that pyrrylfulgide/PMMA films can be used to hide two differently polarized patterns, which may be applied in camouflage technology. (C) 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron. Manuf. Packag. Technol. Soc. Chin. Inst. Electron.; IEEE Compon., Packag., Manuf. Technol. Soc. (IEEE-CPMT); Xidian University

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a new patterning method, the complementary-structure micropatterning (CSMP) technique, to fabricate the undercut structures for the passive-matrix display of organic light-emitting diodes (OLEDs). First, the polyvinylpyrrolidone (PVP) stripe patterns with a trapeziform cross-section were formed by micromolding in capillaries. Then the photoresist was spin coated on the substrate with the patterned PVP stripes and developed in water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Excitation and emission characteristics were reviewed for phosphors which were reported, applied, or suggested for the plasma display panel (PDP). Correlation of luminescence characteristics to the host crystal structure and the activator of the phosphor was explained. Improvements of the PDP phosphor for practicality were considered. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Copolymers containing alternating flexible aliphatic blocks and rigid poly(p-phenylenevinylene) (PPV) blocks were synthesized and characterized. It was found that the fluorescent intensity increases with increasing length of the flexible blocks. Bright blue-light emitting diodes were fabricated using PPV copolymers as electroluminescent layers. The devices show 190 cd/m(2) light-emitting brightness at 460 nm and 15 V rum-on voltage. The effects of oxadiazole derivative PBD and tris(8-hydroxyquinoline) aluminum Alq(3) electron-transporting layers on the luminance and stability of the devices are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a special color film with negative birefringence, which can work as a color filter and a viewing angle extension film for liquid crystal displays (LCDs). A high-performance polyimide (PI), which can be dissolved in the usual organic solvent and shows negative birefringence after lamination, was synthesized to fabricate the film. By mixing PI with suitable proportions of green, blue or red pigment in the solvent, then laminating them onto a glass substrate, we obtained color films with good transmission spectra and suitable chromatic coordinates. The results of our experiments show that the color filters still have negative birefringence but a little lower than that of the pure PI film. and can therefore work as compensation films for normal white twist nematic liquid crystal displays (TN-LCD).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using in vitro selection method to isolate nucleic acids, peptides and proteins has been studied intensively in recent years. In vitro mRNA display is a new and effective technique for peptides selection, and the rationale of this technique is that a synthetic mRNA with puromycin could covalently link with the protein that it encodes, thus an mRNA-protein fusion is formed. This approach has been used in identification of many functional peptides. The peptides binding with thymidylate synthase RNA were isolated using mRNA display technique from a large peptide library (>10(13) different sequences). The selection scheme was constructed, and the experimental conditions, including library synthesis, formation of RNA-peptide fusion and RNA immobilization were optimized. Eight cycles have been processed and the results confirmed that the selected peptides could bind with thymidylate synthase mRNA specifically. Compared the amino acid sequences of the selected peptides with those from the initial random library, the basic and aromatic residues in selected peptides were enriched significantly, suggesting these peptide regions may be important in the peptide-TS mRNA interaction. As a novel in vitro selection approach, mRNA display technique would be developed as a powerful tool for isolation of functional peptides and proteins that could interact with immobilized targets with high affinity and specificity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is concerned with the development of tactual displays to supplement the information available through lipreading. Because voicing carries a high informational load in speech and is not well transmitted through lipreading, the efforts are focused on providing tactual displays of voicing to supplement the information available on the lips of the talker. This research includes exploration of 1) signal-processing schemes to extract information about voicing from the acoustic speech signal, 2) methods of displaying this information through a multi-finger tactual display, and 3) perceptual evaluations of voicing reception through the tactual display alone (T), lipreading alone (L), and the combined condition (L+T). Signal processing for the extraction of voicing information used amplitude-envelope signals derived from filtered bands of speech (i.e., envelopes derived from a lowpass-filtered band at 350 Hz and from a highpass-filtered band at 3000 Hz). Acoustic measurements made on the envelope signals of a set of 16 initial consonants represented through multiple tokens of C1VC2 syllables indicate that the onset-timing difference between the low- and high-frequency envelopes (EOA: envelope-onset asynchrony) provides a reliable and robust cue for distinguishing voiced from voiceless consonants. This acoustic cue was presented through a two-finger tactual display such that the envelope of the high-frequency band was used to modulate a 250-Hz carrier signal delivered to the index finger (250-I) and the envelope of the low-frequency band was used to modulate a 50-Hz carrier delivered to the thumb (50T). The temporal-onset order threshold for these two signals, measured with roving signal amplitude and duration, averaged 34 msec, sufficiently small for use of the EOA cue. Perceptual evaluations of the tactual display of EOA with speech signal indicated: 1) that the cue was highly effective for discrimination of pairs of voicing contrasts; 2) that the identification of 16 consonants was improved by roughly 15 percentage points with the addition of the tactual cue over L alone; and 3) that no improvements in L+T over L were observed for reception of words in sentences, indicating the need for further training on this task

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography? The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. METHODS: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 degrees using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. RESULTS: The mean AUC for the five observers was 0.614 +/- 0.055 for mammography and 0.778 +/- 0.052 for multiview stereoscopy. The difference of 0.164 +/- 0.065 was statistically significant with a p-value of 0.0148. CONCLUSIONS: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Fibronectin-null cells assemble soluble fibronectin shortly after adherence to a substrate coated with intact fibronectin but not when adherent to the cell-binding domain of fibronectin (modules (7)F3-(10)F3). Interactions of adherent cells with regions of adsorbed fibronectin other than modules (7)F3-(10)F3, therefore, are required for early display of the cell surface sites that initiate and direct fibronectin assembly. METHODOLOGY/PRINCIPAL FINDINGS: To identify these regions, coatings of proteolytically derived or recombinant pieces of fibronectin containing modules in addition to (7)F3-(10)F3 were tested for effects on fibronectin assembly by adherent fibronectin-null fibroblasts. Pieces as large as one comprising modules (2)F3-(14)F3, which include the heparin-binding and cell adhesion domains, were not effective in supporting fibronectin assembly. Addition of module (1)F3 or the C-terminal modules to modules (2)F3-(14)F3 resulted in some activity, and addition of both (1)F3 and the C-terminal modules resulted in a construct, (1)F3-C, that best mimicked the activity of a coating of intact fibronectin. Constructs (1)F3-C V0, (1)F3-C V64, and (1)F3-C Delta(V(15)F3(10)F1) were all able to support fibronectin assembly, suggesting that (1)F3 through (11)F1 and/or (12)F1 were important for activity. Coatings in which the active parts of (1)F3-C were present in different proteins were much less active than intact (1)F3-C. CONCLUSIONS: These results suggest that (1)F3 acts together with C-terminal modules to induce display of fibronectin assembly sites on adherent cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gemstone Team Future Firefighting Advancements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance enhancement of AMLCD's has been hindered with problems encountered during the curing process, such as window framing and de-lamination of the glass and adhesive. A thermo-mechanical analysis using FEA was conducted to help optimise the design of the rugged display and enhance the optical performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigated the thermal design of the light emitting diode (LED)onto the board and its packaging. The LED was a 6-lead MultiLED with three chips designed for LCD backlighting and other lighting purposes. A 3D finite element model of this LED was built up and thermal analysis was carried out using the multi physics software package PHYSICA. The modeling results were presented as temperature distributions in each LED, and the predicted junction temperature was used for thermal resistance calculation. The results for the board structure indicated that (1) removing the foil attach decreased the thermal resistance, (2) Increasing the copper foil thickness reduced the thermal resistance. package design indicated that the SMT designed LED with integrated slug gave lower thermal resistance. Pb-free solder material gave lower thermal resistance and junction temperature when compared with conductive adhesive