983 resultados para current measurement
Resumo:
Two studies among college students were conducted to evaluate appropriate measurement methods for etiological research on computing-related upper extremity musculoskeletal disorders (UEMSDs). ^ A cross-sectional study among 100 graduate students evaluated the utility of symptoms surveys (a VAS scale and 5-point Likert scale) compared with two UEMSD clinical classification systems (Gerr and Moore protocols). The two symptom measures were highly concordant (Lin's rho = 0.54; Spearman's r = 0.72); the two clinical protocols were moderately concordant (Cohen's kappa = 0.50). Sensitivity and specificity, endorsed by Youden's J statistic, did not reveal much agreement between the symptoms surveys and clinical examinations. It cannot be concluded self-report symptoms surveys can be used as surrogate for clinical examinations. ^ A pilot repeated measures study conducted among 30 undergraduate students evaluated computing exposure measurement methods. Key findings are: temporal variations in symptoms, the odds of experiencing symptoms increased with every hour of computer use (adjOR = 1.1, p < .10) and every stretch break taken (adjOR = 1.3, p < .10). When measuring posture using the Computer Use Checklist, a positive association with symptoms was observed (adjOR = 1.3, p < 0.10), while measuring posture using a modified Rapid Upper Limb Assessment produced unexpected and inconsistent associations. The findings were inconclusive in identifying an appropriate posture assessment or superior conceptualization of computer use exposure. ^ A cross-sectional study of 166 graduate students evaluated the comparability of graduate students to College Computing & Health surveys administered to undergraduate students. Fifty-five percent reported computing-related pain and functional limitations. Years of computer use in graduate school and number of years in school where weekly computer use was ≥ 10 hours were associated with pain within an hour of computing in logistic regression analyses. The findings are consistent with current literature on both undergraduate and graduate students. ^
Resumo:
This dissertation explores two important aspects of quality in healthcare: its meaning and its measurement. For a better understanding of what quality means, the history of quality in the manufacturing and service industries is reviewed. Concepts that are similar are pointed out as are concepts that are different. The definition introduced by the Institute of Medicine (IOM) for quality in healthcare and the six IOM aims of safety, timeliness, patient-centeredness, effectiveness, efficiency, and equitableness for a high quality healthcare system are adopted. The current activities by various organizations that proclaim improvement in quality or measurement of quality as their goal are reviewed. This is followed by examining what is offered by these organizations in terms of how many of IOM aims they address.^ This dissertation ends by offering a quality measurement framework that satisfies all IOM aims. Operational aspects of the measurement framework are discussed. Future areas of research are also discussed.^
Resumo:
One main point of the air electric investigations at the atlantic 1965 and 1969 was the record of the potential gradient in the troposphere with free and captive balloon ascents. The course of the field vs. altitude above the sea differs from that over land. A remarkable enlargement of the field strength occurs at the altitude of the passat inversion. The electric voltage between ionosphere and earth could be obtained by integrating the potential gradient over the altitude. Such computations have been made by balloon ascents simultaneous over the ocean and at Weissenau (South Germany), From 15 simultaneous measurements the average value of the potential of the ionosphere over the ocean is 214 kV and over South Germany 216 kV, that means very close together. Because of the small differences also between the single values it can be concluded that in generally the ionosphere potential has an equal value over these both places at one moment. From the potential of the ionosphere VI, the field strength E0 and the conductivity lamda o, both measured at the sea surface, the columnar resistance R could be derived to 2.4 x 10**17 Ohm x m**2. By correlation of the single values of the ionosphere potential with the potential gradient measured simultaneously at the surface of the sea a linear proportional relationship exists; it follows from this result, that R is nearly constant. The mean value of the air-earth current density over the ocean could be calculated by using the measured values of the small ion density with respect to the electrode effect prooved at the equator station. The current density was only 0.9 x 10**-12 A/m**2, which means, a three and a half times smaller value than estimated by Carnegie and accepted up to now. Therefore it seems to be necessary to correct the former calculations of the global current balance.
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.
Resumo:
The paper investigates the possibility of constructing a new measurement for analysing international fragmentation of the production process. It asserts that the current usage of relevant data, whether the trade shares of parts and components or the index of Vertical Specialisation, is quite unsatisfactory for measuring the phenomenon, since they critically lack the overall perspective of the entire structure of production chains. The new measurement is formulated such that it captures every aspect of the vertical sequence of production linkages. It is based on the input-output model of Average Propagation Lengths, recently developed by Eric Dietzenbacher and others, which show the average number of production stages that are passed through for an exogenous change in one industry to affect another. By applying this model to the data of the Asian International Input-Output Tables, the index is able to measure the international dimension of production sharing and division of labour in East Asia.
Resumo:
Fiber optic sensors have some advantages in subjects related with electrical current and magnetic field measurement. In spite of the optical fiber utilization advantages we have to take into account undesirable effects, which are present in real non-ideal optical fibers. In telecommunication and sensor application fields the presence of inherent and induced birefringence is crucial. The presence of birefringence may cause an undesirable change in the polarization state. In order to compensate the linear birefringence a promising method has been chosen. This method employs orthogonal polarization conjugation in the back propagation direction of the light wave in the fiber. A study and a simulation of an experimental setup are realized with the advantage of a significant sensitivity improvement.
Resumo:
It is well known that the response of any photovoltaic solar cell is dependent on the spectral characteristics of the incident radiation. This dependency is crucial in the output characteristics of a multijunction (MJ) cell where the spectral composition of the radiation determines the overall photocurrent produced, as either the top or the middle subcell will be limiting its response. The current mismatching between top and middle subcell is translated into energy losses, affecting the yield of the system. For research and commercial purposes it is interesting to measure accurately the incident solar radiation on a MJ cell, in terms of its spectral composition. This measurement will allows us to determine the photocurrent generated in each band of the multijunction device. Nowadays, the only way of measuring the photocurrent generated by each subcell is done with isotype cells or with spectroradiometers but there is no device capable of directly measuring each subcell photocurrent. In this paper it is described a device based on a commercial multijunction solar cell that is capable of measuring the direct irradiance for the top and middle bands thus it offers information of the limiting subcell (top or middle) in outdoors conditions.
Wireless measurement system for structural health monitoring with high time synchronization accuracy
Resumo:
Structural health monitoring (SHM) systems have excellent potential to improve the regular operation and maintenance of structures. Wireless networks (WNs) have been used to avoid the high cost of traditional generic wired systems. The most important limitation of SHM wireless systems is time-synchronization accuracy, scalability, and reliability. A complete wireless system for structural identification under environmental load is designed, implemented, deployed, and tested on three different real bridges. Our contribution ranges from the hardware to the graphical front end. System goal is to avoid the main limitations of WNs for SHM particularly in regard to reliability, scalability, and synchronization. We reduce spatial jitter to 125 ns, far below the 120 μs required for high-precision acquisition systems and much better than the 10-μs current solutions, without adding complexity. The system is scalable to a large number of nodes to allow for dense sensor coverage of real-world structures, only limited by a compromise between measurement length and mandatory time to obtain the final result. The system addresses a myriad of problems encountered in a real deployment under difficult conditions, rather than a simulation or laboratory test bed.
Resumo:
When aqueous suspensions of gold nanorods are irradiated with a pulsing laser (808 nm), pressure waves appear even at low frequencies (pulse repetition rate of 25 kHz). We found that the pressure wave amplitude depends on the dynamics of the phenomenon. For fixed concentration and average laser current intensity, the amplitude of the pressure waves shows a trend of increasing with the pulse slope and the pulse maximum amplitude.We postulate that the detected ultrasonic pressure waves are a sort of shock waves that would be generated at the beginning of each pulse, because the pressure wave amplitude would be the result of the positive interference of all the individual shock waves.
Resumo:
It is our goal within this project to develop a powerful electronic system capable to claim, with high certainty, that a malicious software is running (or not) along with the workstations’ normal activity. The new product will be based on measurement of the supply current taken by a workstation from the grid. Unique technique is proposed within these proceedings that analyses the supply current to produce information about the state of the workstation and to generate information of the presence of malicious software running along with the rightful applications. The testing is based on comparison of the behavior of a fault-free workstation (established i advance) and the behavior of the potentially faulty device.
Resumo:
We recorded miniature endplate currents (mEPCs) using simultaneous voltage clamp and extracellular methods, allowing correction for time course measurement errors. We obtained a 20-80% rise time (tr) of approximately 80 micros at 22 degrees C, shorter than any previously reported values, and tr variability (SD) with an upper limit of 25-30 micros. Extracellular electrode pressure can increase tr and its variability by 2- to 3-fold. Using Monte Carlo simulations, we modeled passive acetylcholine diffusion through a vesicle fusion pore expanding radially at 25 nm x ms(-1) (rapid, from endplate omega figure appearance) or 0.275 nm x ms(-1) (slow, from mast cell exocytosis). Simulated mEPCs obtained with rapid expansion reproduced tr and the overall shape of our experimental mEPCs, and were similar to simulated mEPCs obtained with instant acetylcholine release. We conclude that passive transmitter diffusion, coupled with rapid expansion of the fusion pore, is sufficient to explain the time course of experimentally measured synaptic currents with trs of less than 100 micros.