1000 resultados para cromatografia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methanolic transesterification of oils and fats was carried out in a two steps procedure, under basic and acidic catalysis. Palm, soybean, canola, corn, rice, grapeseed, sunflower, peanut, pequi and olive oils, besides tallow and lard were used as feedstock. Specific gravity, relative viscosity, thin layer chromatography and gas chromatography were used to characterize the biodiesel. Biodiesel was obtained in high yield and purity. Results were used to discuss the following key-concepts: 1 - triglycerides, composition and properties; 2 - nucleophilic acyl substitution under basic and acid conditions, 3 - thin layer chromatography, 4 - gas chromatography and its quantitative methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes three C8-stationary phases for high performance liquid chromatography based on silica metallized with ZrO2, TiO2 or Al2O3 layers, having poly(methyloctylsiloxane) immobilized onto their surfaces. The stationary phases were characterized using XRF, XAS, FTIR, SEM and elemental analysis to determine the physical characteristics of the oxide and polysiloxane layers formed on the surfaces and chromatographically to evaluate the separation parameters. The results show the changes on the silica surface and allowed proposing a structure for the oxide layer, being observed tetrahedral and octahedral structures, what is completely new in the literature. The formation of a homogeneous layer of metallic oxide (TiO2 and ZrO2) was observed on the silica. The C8-titanized and C8-aluminized stationary phases presented good chromatographic performances, with good values of asymmetry and efficiency. All stationary phase presented few loss of the polymeric layer after the HPLC, indicating that this layer is well attached on the metalized support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blooms of cyanobacteria represent a public health risk due to their cyanotoxins such as microcystins. Liquid chromatography techniques to separate and quantify microcystins invariably use acetonitrile as the organic component of the mobile phase. The price and availability of acetonitrile together with its elevated toxicity encourage the validation of acetonitrile-free methods of microcystin analysis. In this work, methanol was employed as the organic solvent of the mobile phase and the validation method was performed with different environmental water samples. The method showed limits of detection between 0.17 and 0.25 µg/L and of quantification between 0.55 and 0.82 µg/L for the microcystin variants: -RR, -YR, -LR, -LA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports a practical case based on the use of microwave-assisted derivatization and GC-MS for the analysis of glucose. Using two different methods for derivatization, one reference compound and the calculated dipole moment, all the isomers of glucose were identified. Identification was corroborated for the assignment of structures using the mass spectra. With this work, students are expected to associate different types of information to solve the complex problem of the analysis of glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation of a rapid method for the determination of ascorbic, citric, fumaric and tartaric acids in stored pulp fruit and its application as a quality parameter was performed. The validation parameters showed that for the four evaluated acids, the method presented low limits of detection (LOD) and quantification (LOQ), indicating good precision and accuracy, thus representing an important tool for quality assessment of stored fruit pulp. The results showed that the concentration of organic acids generally decreased with longer storage time in the fruit pulp under study. Amongst all the organic acids under investigation, ascorbic proved the least stable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate an analytical method for the quantification of tioconazole in polymeric nanocapsule suspensions by high performance liquid chromatography with UV detection. The analysis was performed with a mobile phase composed of methanol:water (80:20) and 0.18% ammonium hydroxide; RP-18 column and UV detection at 219 nm. The method proved to be linear in the concentration range of 5-50 µg mL-1 (r = 0.9999), specific, precise (repeatability RSD = 1.42%, intermediate precision RSD = 1.17%), accurate (98 - 102%) and robust (RSD < 2.0%). In conclusion, a simple and rapid method was validated proving suitable for quantification of tioconazole in polymeric nanocapsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbamazepine, phenobarbital and phenytoin were determined in dried blood spots (DBS) by high performance liquid chromatography, after extraction of 8 mm DBS using a mixture of acetonitrile and methanol. Analytes were separated by reversed-phase chromatography, with a run time of 17 minutes. Intra-assay and inter-assay precisions were in the 5.3 to 8.4% and 3.3 to 5.2% ranges, respectively. Accuracy was in the 98.8 to 104.3% range. The method had sensitivity to detect all analytes at levels below minimum therapeutic concentrations. The analytes were stable at 4 ºC and room temperature for up to 12 days and at 45 ºC for 9 days. The method was applied to 14 paired clinical samples of blood serum and DBS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The peanut is an oleaginous plant of high nutritional value, a source of protein and a trypsin inhibitor. Trypsin inhibitors are proteins present in the vegetable kingdom, considered anti-nutritional factors for animals. However, there have been several recent reports about their heterologous and beneficial effects on human health. These important effects have been the focus of studies investigating these inhibitors in foods. The aim of the present study was to isolate and determine the estimated molecular mass and specific inhibitory activity, for trypsin in the Japanese peanut, peanut butter, and peanut nougat using the techniques of precipitation with ammonium sulfate and affinity chromatography on trypsin - Sepharose CNBr 4B. The techniques used in this study were efficient for isolating the protein inhibitors with antitryptic specific activity of 694 UI mg-1, 823 UI mg-1 and 108 UI mg-1 for the Japanese peanut, peanut nougat, and peanut butter, respectively. The techniques featured high selectivity of the adsorbent, with consequent efficiency in isolation, given the low amount of dosed proteins and specific antitryptic activity presented by the products studied. The various health-related benefits show the importance of detecting and isolating efficient trypsin inhibitors in foods, taking into account the health claims attributed to the vegetable and its high consumption by humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work addresses the use of chiral gas chromatography in resolving optically active stereoisomers and racemates found in fruit flavours. It presents the types of chiral selectors applied to terpene-derived metal coordination compounds, polysiloxane-linked α-amino acid and mixed chiral stationary phases, and focuses on derivatized cyclodextrins, the most popular chiral stationary phases presently used in chromatographic analysis. Knowledge about the techniques involved in chiral recognition and enantiomer identification in the fruit flavour field is given along with examples from the latest studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The constant evolution of science and the growing demand for new technologies have led to new techniques in instrumentation that can improve detection, separation, resolution, and peak capacity. Comprehensive two-dimensional liquid chromatography (LC×LC) is presented as a powerful tool in complex sample analyses. During an analysis, a sample is subjected to two independent separation mechanisms that are combined, resulting in increased resolving power. For appropriate application of LC×LC, understanding the influence of parameters that require optimization is necessary. The main purpose of optimization is to predict the combination of stationary phases, separation conditions, and instrumental requirements to obtain the best separation performance. This review discusses theoretical, intrumental, and chemometric aspects of LC×LC and focuses on its applications in foods. It aims to provide a clear understanding of the aspects that can be used as strategies in the optimization of this analytical method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A complete analysis of oils and their fractions allows correlations to be defined between their composition and derivatives or related geological materials. This work focused on optimization and implementation of a method for separation and quantification of n-alkanes in Brazilian oil samples by urea adduction and GC-FID techniques. Ten samples with different ºAPI were analyzed in triplicate to quantify individual n-alkanes and cyclic/branched alkane fraction. For individual quantification of n-alkanes, internal standardization with deuterated n-tetracosane was used. The use of urea adduction for the separation and quantification of n-alkanes was highly effective, with recovery values of above 80%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the percentage content of free steroid in oils, fats and biodiesel was analyzed. For this, the saponification reaction on a microscale was used, and this procedure for extraction of unsaponifiable fraction was studied in several experimental steps. After the process of saponification, the unsaponifiable fraction was analyzed by gas chromatography with flame ionization detector, where all steroids present in each oil, fat and biodiesel were identified and their contents determined and compared to their respective biodiesel. A reduction in unsaponifiable fraction of each oil and fat and its biodiesel was noted, as well as a reduction in the content of free steroids. The results showed that, compared to the sedimentation problem of steroids in biodiesel, some raw materials, such as chicken fat and babassu oil may be promising because they have low content and high reduction percentages of steroids when converted to biodiesel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC–MS/MS and UHPLC–MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.