891 resultados para coronary artery atherosclerosis
Resumo:
Radial artery (RA) bypass grafts can develop severe vasospasm. As histamine is known to induce vasospasm, its effect on RA was assessed compared with the classic bypass vessels internal mammary artery (MA) and saphenous vein (SV). The vessels were examined in organ chambers for isometric tension recording. Histamine induced contractions on baseline; the sensitivity was higher in RA and SV than MA. After precontraction with norepinephrine, histamine did not evoke relaxations of RA but induced relaxations of MA and less of SV at lower concentrations; it induced contractions at higher concentrations, reaching similar levels in all three vessels. Indomethacin did not affect the response of MA and RA but potentiated relaxations and reduced contractions of SV. Endothelium removal, N(omega)-nitro-L-arginine methyl ester (L-NAME), or the H2-receptor blocker cimetidine did not affect the response of RA, but inhibited relaxations and enhanced contractions in MA and inhibited relaxations in SV; in the latter, only L-NAME enhanced contractions. Real-time PCR detected much lower expression of endothelial H2-receptor in RA than MA or SV. Western blots revealed similar endothelial nitric oxide (NO) synthase expression in all three vessels. Relaxations to acetylcholine were identical in RA and MA. Thus histamine releases NO by activating the endothelial H2-receptor, the expression of which is much lower in RA than MA or SV. H2-receptor activation also releases prostaglandins in SV, partially antagonizing NO. The lack of histamine-induced NO production represents a possible mechanism of RA vasospasm.
Resumo:
CONTEXT: Compared with bare metal stents, sirolimus-eluting and paclitaxel-eluting stents have been shown to markedly improve angiographic and clinical outcomes after percutaneous coronary revascularization, but their performance in the treatment of de novo coronary lesions has not been compared in a prospective multicenter study. OBJECTIVE: To compare the safety and efficacy of sirolimus-eluting vs paclitaxel-eluting coronary stents. DESIGN: Prospective, randomized comparative trial (the REALITY trial) conducted between August 2003 and February 2004, with angiographic follow-up at 8 months and clinical follow-up at 12 months. SETTING: Ninety hospitals in Europe, Latin America, and Asia. PATIENTS: A total of 1386 patients (mean age, 62.6 years; 73.1% men; 28.0% with diabetes) with angina pectoris and 1 or 2 de novo lesions (2.25-3.00 mm in diameter) in native coronary arteries. INTERVENTION: Patients were randomly assigned in a 1:1 ratio to receive a sirolimus-eluting stent (n = 701) or a paclitaxel-eluting stent (n = 685). MAIN OUTCOME MEASURES: The primary end point was in-lesion binary restenosis (presence of a more than 50% luminal-diameter stenosis) at 8 months. Secondary end points included 1-year rates of target lesion and vessel revascularization and a composite end point of cardiac death, Q-wave or non-Q-wave myocardial infarction, coronary artery bypass graft surgery, or repeat target lesion revascularization. RESULTS: In-lesion binary restenosis at 8 months occurred in 86 patients (9.6%) with a sirolimus-eluting stent vs 95 (11.1%) with a paclitaxel-eluting stent (relative risk [RR], 0.84; 95% confidence interval [CI], 0.61-1.17; P = .31). For sirolimus- vs paclitaxel-eluting stents, respectively, the mean (SD) in-stent late loss was 0.09 (0.43) mm vs 0.31 (0.44) mm (difference, -0.22 mm; 95% CI, -0.26 to -0.18 mm; P<.001), mean (SD) in-stent diameter stenosis was 23.1% (16.6%) vs 26.7% (15.8%) (difference, -3.60%; 95% CI, -5.12% to -2.08%; P<.001), and the number of major adverse cardiac events at 1 year was 73 (10.7%) vs 76 (11.4%) (RR, 0.94; 95% CI, 0.69-1.27; P = .73). CONCLUSION: In this trial comparing sirolimus- and paclitaxel-eluting coronary stents, there were no differences in the rates of binary restenosis or major adverse cardiac events. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00235092.
Resumo:
BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.
Resumo:
Background. Subjective memory complaints are common after coronary artery bypass grafting (CABG), but previous studies have concluded that such symptoms are more closely associated with depressed mood than objective cognitive dysfunction. We compared the incidence of self-reported memory symptoms at 3 and 12 months after CABG with that of a control group of patients with comparable risk factors for coronary artery disease but without surgery. Methods. Patients undergoing CABG (n = 140) and a demographically similar nonsurgical control group with coronary artery disease (n = 92) were followed prospectively at 3 and 12 months. At each follow-up time, participants were asked about changes since the previous evaluation in areas of memory, calculations, reading, and personality. A Functional Status Questionnaire (FSQ) and self-report measure of symptoms of depression (CES-D) were also completed. Results. The frequency of self-reported changes in memory, personality, and reading at 3 months was significantly higher among CABG patients than among nonsurgical controls. By contrast, there were no differences in the frequency of self-reported symptoms relating to calculations or overall rating of functional status. After adjusting for a measure of depression (CES-D rating score), the risk for self-reported memory changes remained nearly 5 times higher among the CABG patients than control subjects. The relative risk of developing new self-reported memory symptoms between 3 and 12 months was 2.5 times higher among CABG patients than among nonsurgical controls (CI 1.24 – 5.02), and the overall prevalence of memory symptoms at 12 months was also higher among CABG patients (39%) than controls (14%). Conclusions. The frequency of self-reported memory symptoms 3 and 12 months after baseline is significantly higher among CABG patients than control patients with comparable risk factors for coronary and cerebrovascular disease. These differences could not be accounted for by symptoms of depression. The self-reported cognitive symptoms appear to be relatively specific for memory, and may reflect aspects of memory functioning that are not captured by traditional measures of new verbal learning and memory. The etiology of these self-reported memory symptoms remains unclear, but our findings as well as those of others, may implicate factors other than cardiopulmonary bypass itself.
Resumo:
OBJECTIVES: Our purpose was to make a synthesis of the available evidence on the relative efficacy and safety of 2 drug-eluting stents (DES)--sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES)--in patients with coronary artery disease. BACKGROUND: It is not known whether there are differences in late outcomes between the 2 most commonly used DES: SES and PES. METHODS: Sixteen randomized trials of SES versus PES with a total number of 8,695 patients were included in this meta-analysis. A full set of individual outcome data from 5,562 patients was also available. Mean follow-up period ranged from 9 to 37 months. The primary efficacy end point was the need for reintervention (target lesion revascularization). The primary safety end point was stent thrombosis. Secondary end points were death and recurrent myocardial infarction (MI). RESULTS: No significant heterogeneity was found across trials. Compared with PES, SES significantly reduced the risk of reintervention (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.63 to 0.87, p < 0.001) and stent thrombosis (HR 0.66; 95% CI 0.46 to 0.94, p = 0.02) without significantly impacting on the risk of death (HR 0.92; 95% CI 0.74 to 1.13, p = 0.43) or MI (HR 0.84; 95% CI 0.69 to 1.03, p = 0.10). CONCLUSIONS: Sirolimus-eluting stents are superior to PES in terms of a significant reduction of the risk of reintervention and stent thrombosis. The risk of death was not significantly different between the 2 DES, but there was a trend toward a higher risk of MI with PES, especially after the first year from the procedure.
Resumo:
BACKGROUND: The prognostic relevance of the collateral circulation is still controversial. The goal of this study was to assess the impact on survival of quantitatively obtained, recruitable coronary collateral flow in patients with stable coronary artery disease during 10 years of follow-up. METHODS AND RESULTS: Eight-hundred forty-five individuals (age, 62+/-11 years), 106 patients without coronary artery disease and 739 patients with chronic stable coronary artery disease, underwent a total of 1053 quantitative, coronary pressure-derived collateral measurements between March 1996 and April 2006. All patients were prospectively included in a collateral flow index (CFI) database containing information on recruitable collateral flow parameters obtained during a 1-minute coronary balloon occlusion. CFI was calculated as follows: CFI = (P(occl) - CVP)/(P(ao) - CVP) where P(occl) is mean coronary occlusive pressure, P(ao) is mean aortic pressure, and CVP is central venous pressure. Patients were divided into groups with poorly developed (CFI < 0.25) or well-grown collateral vessels (CFI > or = 0.25). Follow-up information on the occurrence of all-cause mortality and major adverse cardiac events after study inclusion was collected. Cumulative 10-year survival rates in relation to all-cause deaths and cardiac deaths were 71% and 88%, respectively, in patients with low CFI and 89% and 97% in the group with high CFI (P=0.0395, P=0.0109). Through the use of Cox proportional hazards analysis, the following variables independently predicted elevated cardiac mortality: age, low CFI (as a continuous variable), and current smoking. CONCLUSIONS: A well-functioning coronary collateral circulation saves lives in patients with chronic stable coronary artery disease. Depending on the exact amount of collateral flow recruitable during a brief coronary occlusion, long-term cardiac mortality is reduced to one fourth compared with the situation without collateral supply.
Resumo:
The coronary artery calcium (CAC) score is a readily and widely available tool for the noninvasive diagnosis of atherosclerotic coronary artery disease (CAD). The aim of this study was to investigate the added value of the CAC score as an adjunct to gated SPECT for the assessment of CAD in an intermediate-risk population. METHODS: Seventy-seven prospectively recruited patients with intermediate risk (as determined by the Framingham Heart Study 10-y CAD risk score) and referred for coronary angiography because of suspected CAD underwent stress (99m)Tc-tetrofosmin SPECT myocardial perfusion imaging (MPI) and CT CAC scoring within 2 wk before coronary angiography. The sensitivity and specificity of SPECT alone and of the combination of the 2 methods (SPECT plus CAC score) in demonstrating significant CAD (>/=50% stenosis on coronary angiography) were compared. RESULTS: Forty-two (55%) of the 77 patients had CAD on coronary angiography, and 35 (45%) had abnormal SPECT results. The CAC score was significantly higher in subjects with perfusion abnormalities than in those who had normal SPECT results (889 +/- 836 [mean +/- SD] vs. 286 +/- 335; P < 0.0001). Similarly, with rising CAC scores, a larger percentage of patients had CAD. Receiver-operating-characteristic analysis showed that a CAC score of greater than or equal to 709 was the optimal cutoff for detecting CAD missed by SPECT. SPECT alone had a sensitivity and a specificity for the detection of significant CAD of 76% and 91%, respectively. Combining SPECT with the CAC score (at a cutoff of 709) improved the sensitivity of SPECT (from 76% to 86%) for the detection of CAD, in association with a nonsignificant decrease in specificity (from 91% to 86%). CONCLUSION: The CAC score may offer incremental diagnostic information over SPECT data for identifying patients with significant CAD and negative MPI results.
Resumo:
We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.
Resumo:
AIMS/HYPOTHESIS: Retinol-binding protein 4 (RBP4) has recently been reported to be associated with insulin resistance and the metabolic syndrome. This study tested the hypothesis that RBP4 is a marker of insulin resistance and the metabolic syndrome in patients with type 2 diabetes or coronary artery disease (CAD) or in non-diabetic control subjects without CAD. METHODS: Serum RBP4 was measured in 365 men (126 with type 2 diabetes, 143 with CAD and 96 control subjects) and correlated with the homeostasis model assessment of insulin resistance index (HOMA-IR), components of the metabolic syndrome and lipoprotein metabolism. RBP4 was detected by ELISA and validated by quantitative Western blotting. RESULTS: RBP4 concentrations detected by ELISA were shown to be strongly associated with the results gained in quantitative Western blots. There were no associations of RBP4 with HOMA-IR or HbA(1c) in any of the groups studied. In patients with type 2 diabetes there were significant positive correlations of RBP4 with total cholesterol, LDL-cholesterol, VLDL-cholesterol, plasma triacylglycerol and hepatic lipase activity. In patients with CAD, there were significant associations of RBP4 with VLDL-cholesterol, plasma triacylglycerol and hepatic lipase activity, while non-diabetic control subjects without CAD showed positive correlations of RBP4 with VLDL-cholesterol and plasma triacylglycerol. CONCLUSIONS/INTERPRETATION: RBP4 does not seem to be a valuable marker for identification of the metabolic syndrome or insulin resistance in male patients with type 2 diabetes or CAD. Independent associations of RBP4 with pro-atherogenic lipoproteins and enzymes of lipoprotein metabolism indicate a possible role of RBP4 in lipid metabolism.
Resumo:
Determining whether hypoplasia of a coronary artery has caused or contributed to death is often complicated by an absence of histologic evidence of myocardial ischemia in the area of the heart supplied by the affected artery and also by the lack of data for assessing coronary artery size at autopsy. A 45-year-old woman is reported who collapsed and died and who was found at autopsy to have a dominant, small-caliber, right coronary artery, with acute and chronic ischemic changes in the posterior interventricular septum supplied by the diminutive vessel. This case provides evidence that small-caliber coronary arteries may be associated with a lethal outcome. Given the difficulties that may occur in determining whether there is a causal link between small coronary artery caliber and death, it is possible that this may be an underdiagnosed cause of sudden cardiac death, rather than a coincidental finding of minimal significance.