947 resultados para chemical oxygen demand
Resumo:
Anaerobic digestion of food scraps has the potential to accomplish waste minimization, energy production, and compost or humus production. At Bucknell University, removal of food scraps from the waste stream could reduce municipal solid waste transportation costs and landfill tipping fees, and provide methane and humus for use on campus. To determine the suitability of food waste produced at Bucknell for high-solids anaerobic digestion (HSAD), a year-long characterization study was conducted. Physical and chemical properties, waste biodegradability, and annual production of biodegradable waste were assessed. Bucknell University food and landscape waste was digested at pilot-scale for over a year to test performance at low and high loading rates, ease of operation at 20% solids, benefits of codigestion of food and landscape waste, and toprovide digestate for studies to assess the curing needs of HSAD digestate. A laboratory-scale curing study was conducted to assess the curing duration required to reduce microbial activity, phytotoxicity, and odors to acceptable levels for subsequent use ofhumus. The characteristics of Bucknell University food and landscape waste were tested approximately weekly for one year, to determine chemical oxygen demand (COD), total solids (TS), volatile solids (VS), and biodegradability (from batch digestion studies). Fats, oil, and grease and total Kjeldahl nitrogen were also tested for some food waste samples. Based on the characterization and biodegradability studies, Bucknell University dining hall food waste is a good candidate for HSAD. During batch digestion studies Bucknell University food waste produced a mean of 288 mL CH4/g COD with a 95%confidence interval of 0.06 mL CH4/g COD. The addition of landscape waste for digestion increased methane production from both food and landscape waste; however, because the landscape waste biodegradability was extremely low the increase was small.Based on an informal waste audit, Bucknell could collect up to 100 tons of food waste from dining facilities each year. The pilot-scale high-solids anaerobic digestion study confirmed that digestion ofBucknell University food waste combined with landscape waste at a low organic loading rate (OLR) of 2 g COD/L reactor volume-day is feasible. During low OLR operation, stable reactor performance was demonstrated through monitoring of biogas production and composition, reactor total and volatile solids, total and soluble chemical oxygendemand, volatile fatty acid content, pH, and bicarbonate alkalinity. Low OLR HSAD of Bucknell University food waste and landscape waste combined produced 232 L CH4/kg COD and 229 L CH4/kg VS. When OLR was increased to high loading (15 g COD/L reactor volume-day) to assess maximum loading conditions, reactor performance became unstable due to ammonia accumulation and subsequent inhibition. The methaneproduction per unit COD also decreased (to 211 L CH4/kg COD fed), although methane production per unit VS increased (to 272 L CH4/kg VS fed). The degree of ammonia inhibition was investigated through respirometry in which reactor digestate was diluted and exposed to varying concentrations of ammonia. Treatments with low ammoniaconcentrations recovered quickly from ammonia inhibition within the reactor. The post-digestion curing process was studied at laboratory-scale, to provide a preliminary assessment of curing duration. Digestate was mixed with woodchips and incubated in an insulated container at 35 °C to simulate full-scale curing self-heatingconditions. Degree of digestate stabilization was determined through oxygen uptake rates, percent O2, temperature, volatile solids, and Solvita Maturity Index. Phytotoxicity was determined through observation of volatile fatty acid and ammonia concentrations.Stabilization of organics and elimination of phytotoxic compounds (after 10–15 days of curing) preceded significant reductions of volatile sulfur compounds (hydrogen sulfide, methanethiol, and dimethyl sulfide) after 15–20 days of curing. Bucknell University food waste has high biodegradability and is suitable for high-solids anaerobic digestion; however, it has a low C:N ratio which can result in ammonia accumulation under some operating conditions. The low biodegradability of Bucknell University landscape waste limits the amount of bioavailable carbon that it can contribute, making it unsuitable for use as a cosubstrate to increase the C:N ratio of food waste. Additional research is indicated to determine other cosubstrates with higher biodegradabilities that may allow successful HSAD of Bucknell University food waste at high OLRs. Some cosubstrates to investigate are office paper, field residues, or grease trap waste. A brief curing period of less than 3 weeks was sufficient to produce viable humus from digestate produced by low OLR HSAD of food and landscape waste.
Resumo:
The use of coal for fuel in place of oil and natural gas has been increasing in the United States. Typically, users store their reserves of coal outdoors in large piles and rainfall on the coal creates runoffs which may contain materials hazardous to the environment and the public's health. To study this hazard, rainfall on model coal piles was simulated, using deionized water and four coals of varying sulfur content. The simulated surface runoffs were collected during 9 rainfall simulations spaced 15 days apart. The runoffs were analyzed for 13 standard water quality parameters, extracted with organic solvents and then analyzed with capillary column GC/MS, and the extracts were tested for mutagenicity with the Ames Salmonella microsomal assay and for clastogenicity with Chinese hamster ovary cells.^ The runoffs from the high-sulfur coals and the lignite exhibited extremes of pH (acidity), specific conductance, chemical oxygen demand, and total suspended solids; the low-sulfur coal runoffs did not exhibit these extremes. Without treatment, effluents from these high-sulfur coals and lignite would not comply with federal water quality guidelines.^ Most extracts of the simulated surface runoffs contained at least 10 organic compounds including polycyclic aromatic hydrocarbons, their methyl and ethyl homologs, olefins, paraffins, and some terpenes. The concentrations of these compounds were generally less than 50 (mu)g/l in most extracts.^ Some of the extracts were weakly mutagenic and affected both a DNA-repair proficient and deficient Salmonella strain. The addition of S9 decreased the effect significantly. Extracts of runoffs from the low-sulfur coal were not mutagenic.^ All extracts were clastogenic. Extracts of runoffs from the high-sulfur coals were both clastogenic and cytotoxic; those from the low-sulfur coal and the lignite were less clastogenic and not cytotoxic. Clastogenicity occurred with and without S9 activation. Chromosomal lesions included gaps, breaks and exchanges. These data suggest a relationship between the sulfur content of a coal, its mutagenicity and also its clastogenicity.^ The runoffs from actual coal piles should be investigated for possible genotoxic effects in view of the data presented in this study.^
Resumo:
El río Mendoza conforma el oasis norte que es el más importante de la provincia. El crecimiento urbano ha avanzado sobre áreas originalmente agrícolas, rodeando la red de canales y desagües, que también recibe los desagües pluviales urbanos, producto de tormentas convectivas. La actividad antropogénica utiliza el recurso para bebida, saneamiento, riego, recreación, etc., y vuelca sus excedentes a la red, contaminándola. Para conocer la calidad del agua de esta cuenca se seleccionaron, estratégicamente, 15 sitios de muestreo: 3 a lo largo del río y a partir del dique derivador Cipolletti (R_I a R_III), 5 en la red de canales (C_I a C_V) y 7 ubicados en los colectores de drenaje (D_I a D_VII). Se realizaron los siguientes análisis físico-químicos y microbiológicos; en el río y en la red de canales: conductividad eléctrica, temperatura, pH, aniones y cationes (cálculo de RAS), oxígeno disuelto (OD), sólidos sedimentables, demanda química de oxígeno (DQO), bacterias aerobias mesófilas (BAM), coliformes totales y fecales y metales pesados. En la red de drenaje sólo se realizaron los cuatro primeros. Los resultados de los análisis, se incorporaron a una base de datos y se sometieron a un análisis estadístico descriptivo e inferencial. Este último consistió en la aplicación de diversas pruebas en busca de posibles diferencias entre los sitios de muestreo, para cada variable respuesta, a un α = 0.05. Se realizó el análisis de la varianza de efectos fijos y de efectos aleatorios y se probaron los supuestos de homocedasticidad y de normalidad de los errores. En el caso de violación de los supuestos, se utilizó la prueba de Kruskal- Wallis. Se compararon los siguientes sitios de muestreo entre sí: ríos, R_I-canales y drenajes. Se concluyó que hay un aumento significativo de la salinidad y la sodicidad en R_II, que los cambios de calidad ocurridos entre R_II y R_III podrían deberse al aporte de otras aguas. Con respecto a la comparación de los parámetros entre la cabeza del sistema (R_I) y la red de canales se puede decir que los aportes realizados por los escurrimientos urbanos ubicados hacia el oeste del canal Cacique Guaymallén, sumados a los vuelcos de Campo Espejo (detectados en C_II), incrementan significativamente la salinidad (+55 %) y sodicidad del agua (+95 %) respecto del punto R_I, aunque el valor de sodicidad sigue siendo bajo. También se han encontrado incrementos de salinidad (+80 %), de DQO (+1159 %) y BAM (+2873 %) con lógica disminución de OD (-58 %) en el punto C_V (canal Auxiliar Tulumaya) respecto del punto R_I, ocasionados por aportes urbanos (Gran Mendoza) sumados a la carga contaminante del canal Pescara. Los metales pesados no presentan grandes diferencias entre sitios de muestreo.
Resumo:
Feedlots have increased in several regions of Argentina, particularly in the Pampas. The absence of adequate treatments of the effluents produced in these establishments creates serious problems to the society. Phytoremediation can be defined as inexpensive and environmentally sustainable strategy used to remove pollutants by plants. The aim of this study was to evaluate the remediation potential of two macrophyte species (Eichhornia crassipes and Hydrocotyle ranunculoides) on a feedlot effluent. This effluent was treated with these species for 31 days. Control and macrophyte treatments decreased dissolved inorganic nitrogen (DIN), Kjeldahl nitrogen (Kj N), biological oxygen demand (BOD), chemical oxygen demand (COD), total dissolved salts (TDS), total phosphorus (TP), Pb, Zn and Cr levels. At macrophyte treatments, relatively constant pH levels were kept and decreased EC and TDS values were obtained compared to control, mitigating the release of contaminants and potential greenhouse gases to the atmosphere. Moreover, significant increases in biomass were obtained, being higher in E. crassipes. The results allow concluding that the presence of aquatic plants increases the removal rates of nutrients, organic matter and heavy metals from wastewater in approximately 10-17 days for a feedlot effluent with high organic load.
Resumo:
O propósito do presente estudo foi investigar e monitorar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. por diferentes processos de uma estação de tratamento de esgoto (ETE) em escala plena, composta basicamente por tratamento preliminar, reator UASB e flotador por ar dissolvido, e verificar a ocorrência desses protozoários no lodo do reator UASB e do flotador. Além disso, avaliou-se a remoção desses parasitos pelo processo de flotação por ar dissolvido em escala de bancada (equipamento Flotateste). Analisou-se a qualidade das amostras a partir de variáveis físicas e químicas, e pela detecção de microrganismos indicadores - E. coli, coliformes totais e Clostridium perfringens. Os métodos de detecção de protozoários se basearam nas etapas de concentração (tripla centrifugação ou filtração em membrana seguida de tripla centrifugação); purificação por separação imunomagnética (IMS); detecção por reação de imunofluorescência direta (RID). As recuperações de cistos variaram de 32,6 a 67,0 % dependendo do método adotado, já para os oocistos as recuperações estiveram na faixa de 5,6 a 12,0 %. Na ETE-Monjolinho foram detectadas significativas quantidades de cistos de Giardia spp. em 100% das amostras de esgoto analisadas, com concentração média de 1,89 x 104 e 2,35 x 102 cistos.L-1 no esgoto bruto e tratado, respectivamente. Já os oocistos de Cryptosporidium spp. foram detectados em 39,0 % das amostras de esgoto, com concentração média de 1,35 x 102 oocistos.L-1 no esgoto bruto e 5,87 oocistos.L-1 em esgoto tratado (após flotador). A remoção global da ETE para remoção de Giardia spp. foi em média 2,03 log. O lodo do reator UASB e lodo do flotador apresentaram altas quantidade de (oo)cistos, constatando-se a tendência desses sistemas em concentrar os (oo)cistos por seus processos físicos. Algumas correlações significativas foram encontradas, como correlação entre a concentração de cistos no lodo e a variável sólidos totais, a concentração de cistos no esgoto bruto e as variáveis cor aparente, DQO total e particulada, e a concentração de cistos no efluente UASB e o microrganismo Clostridium perfringens. Diferentemente do flotador em escala plena, o processo do flotação por ar dissolvido em escala de bancada alcançou elevadas remoções médias de cistos de Giardia spp., entre 2,5 e 2,7 log nas diferentes condições de floculação estudadas.
Resumo:
In this study, the filtration process and the biomass characteristics in a laboratory-scale submerged membrane bioreactor (MBR) equipped with a hollow fiber (HF) microfiltration membrane were studied at different solid retention times (SRT). The MBR was fed by synthetic wastewater and the organic loading rate (OLR) was 0.5, 0.2, 0.1, and 0.08 kg COD kg VSS−1 d−1 for 10, 30, 60, and 90 days of SRT, respectively. The hydraulic retention time was 8.4 h and the permeate flux was 6 L m−2 h−1(LMH). Data analysis confirmed that at all the studied SRTs, the HF-MBR operated very good obtaining of high quality permeates. Chemical Oxygen Demand (COD) removal efficiencies were higher than 95%. The best filtration performance was reached at SRT of 30 d. On the other hand, the respirometric analysis showed that biomass was more active and there was more biomass production at low SRTs. The concentration of soluble extracellular polymeric substances (EPS) decreased with increasing SRT. A decrease of soluble EPS caused a decrease of membrane fouling rate, decreasing the frequency of chemical cleanings. The floc size decreased with SRT increasing. At high SRTs, there was more friction among particles due to the increase of the cellular density and the flocs broke decreasing their size.
Resumo:
It is widely accepted that cellulose is the rate-limiting substrate in the anaerobic digestion of organic solid wastes and that cellulose solubilisation is largely mediated by surface attached bacteria. However, little is known about the identity or the ecophysiology of cellulolytic microorganisms from landfills and anaerobic digesters. The aim of this study was to investigate an enriched cellulolytic microbial community from an anaerobic batch reactor. Chemical oxygen demand balancing was used to calculate the cellulose solubilisation rate and the degree of cellulose solubilisation. Fluorescence in situ hybridisation (FISH) was used to assess the relative abundance and physical location of three groups of bacteria belonging to the Clostridium lineage of the Firmicutes that have been implicated as the dominant cellulose degraders in this system. Quantitation of the relative abundance using FISH showed that there were changes in the microbial community structure throughout the digestion. However, comparison of these results to the process data reveals that these changes had no impact on the cellulose solubilisation in the reactor. The rate of cellulose solubilisation was approximately stable for much of the digestion despite changes in the cellulolytic population. The solubilisation rate appears to be most strongly affected by the rate of surface area colonisation and the biofilm architecture with the accepted model of first order kinetics due to surface area limitation applying only when the cellulose particles are fully covered with a thin layer of cells. (c) 2005 Wiley Periodicals, Inc.
Resumo:
This paper proposed the study of the treatment of a synthetic wastewater contaminated with BTX by electro-oxidation batch with the anode of Ti/PbO2, and the adsorption of BTX using expanded perlite as adsorbent material, and to evaluate the best operating conditions both methods in order to perform a sequential treatment (adsorption and electro-oxidation) and achieve greater efficiency in the removal of the compounds. The operating conditions were measured: temperature, current density and applied amount of the adsorbent material, by UV-VIS analysis and Demand Chemical oxygen demand (COD). According to the experimental results, the electro-oxidative treatment was efficient in the degradation of the compounds BTX (benzene, toluene and xylenes) in synthetic sewage due to the electrochemical properties of the anode of Ti/PbO2. The applied current density and temperature promoted increased efficiency of COD removal, reaching obtain percentages greater than 70%. In the adsorption process, the temperature increase was not a factor in the removal of organic matter, while the increase in the amount of adsorbent material led to an increase in the percentage removal, obtaining 66.30% using 2 g of adsorbent. The selected operating conditions of both treatments performed separately take into account the removal efficiency of organic matter, and the low energy consumption and operating costs, so the sequential treatment were satisfactory reaching 87.26% of COD removal using adsorption as a pretreatment. Quantification of BTX through the analysis of gas chromatography at the end of the treatments also confirmed the removal efficiency of organic compounds, giving outstanding advantages to sequential treatment.
Resumo:
The produce of waste and the amount of the water produced coming from activities of petroleum production and extraction has been a biggest challenge for oil companies with respect to environmental compliance due to toxicity. The discard or the reuse this effluent containing organic compounds as BTEX (benzene, toluene, ethylbenzene and xylene) can cause serious environmental and human health problems. Thus, the objective this paper was study the performance of two process (separately and sequential) in one synthetic effluent for the benzene, toluene and xylene removal (volatile hydrocarbons presents in the produced water) through of electrochemical treatment using Ti/Pt electrode and exchange resin ionic used in the adsorption process. The synthetic solution of BTX was prepared with concentration of 22,8 mg L-1, 9,7 mg L-1 e 9,0 mg L-1, respectively, in Na2SO4 0,1 mol L-1. The experiments was developed in batch with 0.3 L of solution at 25ºC. The electrochemical oxidation process was accomplished with a Ti/Pt electrode with different current density (J = 10, 20 e 30 mA.cm-2). In the adsorption process, we used an ionic exchange resin (Purolite MB 478), using different amounts of mass (2,5, 5 and 10 g). To verify the process of technics in the sequential treatment, was fixed the current density at 10 mA cm-2 and the resin weight was 2.5 g. Analysis of UV-VIS spectrophotometry, chemical oxygen demand (COD) and gas chromatography with selective photoionization detector (PID) and flame ionization (FID), confirmed the high efficiency in the removal of organic compounds after treatment. It was found that the electrochemical process (separate and sequential) is more efficient than absorption, reaching values of COD removal exceeding 70%, confirmed by the study of the cyclic voltammetry and polarization curves. While the adsorption (separately), the COD removal did not exceed 25,8%, due to interactions resin. However, the sequential process (electrochemical oxidation and adsorption) proved to be a suitable alternative, efficient and cost-effectiveness for the treatment of effluents petrochemical.
Resumo:
Textile industry has been a cause of environmental pollution, mainly due to the generation of large volumes of waste containing high organic loading and intense color. In this context, this study evaluated the electrochemical degradation of synthetic effluents from textile industry containing Methylene Blue (AM) dye, using Ti/IrO2-Ta2O5 and Ti/Pt anodes, by direct and indirect (active chlorine) electrooxidation. We evaluated the influence of applied current density (20, 40 and 60 mA/cm2 ), and the presence of different concentrations of electrolyte (NaCl and Na2SO4), as well as the neutral and alkaline pH media. The electrochemical treatment was conducted in a continuous flow reactor, in which the electrolysis time of the AM 100 ppm was 6 hours. The performance of electrochemical process was evaluated by UV-vis spectrophotometry, chemical oxygen demand (COD) and total organic carbon (TOC). The results showed that with increasing current density, it was possible to obtain 100 % of color removal at Ti/IrO2-Ta2O5 and Ti/Pt electrodes. Regarding the color removal efficiency, increasing the concentration of electrolyte promotes a higher percentage of removal using 0,02 M Na2SO4 and 0,017 M NaCl. Concerning to the aqueous medium, the best color removal results were obtained in alkaline medium using Ti/Pt. In terms of organic matter, 86 % was achieved in neutral pH medium for Ti/Pt; while a 30 % in an alkaline medium. To understand the electrochemical behavior due to the oxygen evolution reaction, polarization curves were registered, determining that the presence of NaCl in the solution favored the production of active chlorine species. The best results in energy consumption and cost were obtained by applying lower current density (20 mA/cm2 ) in 6 hours of electrolysis.
Resumo:
Electrochemical technologies have been proposed as a promising alternative for the treatment of effluents and contaminated soils. Therefore, the objective of this work was to study the treatment of contaminated soils and wastewaters using electrochemical technologies. Thus, the study regarding the scale-up of the electrochemical system with continuous flow treatment of wastewater of the petrochemical industry was investigated using platinum electrodes supported on titanium (Ti / Pt), and boron-doped diamond (BDD). The results clearly showed that under the operating conditions studied and electrocatalytic materials employed, the better removal efficiency was achieved with BDD electrode reducing the chemical oxygen demand (COD) from 2746 mg L-1 to 200 mg L-1 in 5 h consuming 56.2 kWh m-3 . The decontamination of soils and effluents by petrochemical products was evaluated by studying the effects of electrokinetic remediation for removal of total petroleum hydrocarbons (HTP) from contaminated soil with diesel. The efficiency of this process was dependent on the electrolyte used Na2SO4 (96.46%), citric acid (81.36%) and NaOH (68.03%) for 15 days. Furthermore, the effluent after treatment of the soil was treated by electrochemical oxidation, achieving a good elimination of the organic polluting load dissolved. Depending on the physical behavior of wastewater contaminated with oil (emulsified state); atrazine emulsified effluents were investigated. The main characteristics of the effluent produced during the washing of contaminated soil were studied, being dependent on the surfactant dosage used; which determined its electrolytic treatment with BDD. The electrochemical oxidation of emulsified effluent of atrazine was efficient, but the key to the treatment is reducing the size of micelles.
Resumo:
Despite the numerous advantages resulting from the use of membrane filters technology, intrinsic limitations fouling process become relevant to its applicability. The control of operating conditions is an important tool to mitigate fouling and achieve good levels of efficiency. In this sense, the objective of this study was to investigate the effect of transmembrane pressure and concentrate flow in the performance of ultrafiltration, applied to the post-treatment of domestic sewage. The process was evaluated and optimized by varying the pressure (0.5 and 1.5 bar) and the concentrate flow (300 and 600 L/h), using a 22 factorial design, in order to investigate the effects on the permeate flow and quality of effluents generated at each operating condition. We evaluated the following quality indicators for permeate: pH, electrical conductivity, total suspended solids, turbidity, calcium and Chemical Oxygen Demand (COD). In all tests, we observed marked reduction in the permeate flux at the early stages, followed by a slow decline that lasted until it reaches a relatively constant level, around 120 minutes of filtration. The increased pressure resulted in a higher initial permeate flux, but the decrease of the flow with time is greater for tests at higher pressure, indicating a more pronounced fouling process. On the other hand, increasing the concentrate flow resulted in a slower decline in permeate flux with the filtration time. Regarding the quality of permeate, the transmembrane pressure of 0,5 bar was the one that allowed better results, and was statistically confirmed through the two-way ANOVA test with repeated measures, significant effect of pressure on the turbidity of the permeate. The concentrate flow, in turn, showed no significant influence on any of the quality parameters. Thus, we conclude that, from an economic and environmental point of view, it is more interesting to operate ultrafiltration membrane system with a lower concentrate flow associated with a low transmembrane pressure, since under these conditions will produce less waste, and the permeate will present lower concentrations of the analyzed constituent, especially lower turbidity.
Resumo:
En este trabajo se presenta la descripción e investigación en la evaluación de vetiver (Chrysopogon zizanioides) y la elefanta (Pennisetum purpureum) en el diseño de humedales artificiales. Para el tratamiento de aguas residuales de origen doméstico, siendo la vegetación uno de los principales componentes de estos sistemas de tratamientos no convencionales. Muchos \sistemas naturales" están siendo considerados con el propósito del tratamiento del agua residual y control de la contaminación del agua, debido a su alta fiabilidad ambiental y los bajos costos de construcción y mantenimiento, es el caso de los humedales artificiales. El interés en los sistemas naturales está basado en la conservación de los recursos asociados con estos sistemas como opuesto al proceso de tratamiento convencional de aguas residuales que es intensivo respecto al uso de energía y químicos. Los wetlands o humedales artificiales constituyen una alternativa de tratamiento debido a su alta eficiencia de remoción de contaminantes, a su bajo costo de instalación y mantenimiento y a su alta fiabilidad ambiental, generalmente un humedal artificial esta constituido por un medio de soporte el cual generalmente es arena o grava, vegetación y microorganismos o biopelícula los cuales llevan los diferentes procesos bioquímicos para remover los contaminantes del afluente. El objetivo general de este trabajo ha sido: Evaluar la eficiencia de remoción de materia orgánica, sólidos, nitrógeno y fósforo total de dos especies de plantas: vetiver (Chrysopogon zizanioides) y la elefanta (Pennisetum purpureum), en el diseño de humedales artificiales para el tratamiento de aguas residuales de origen doméstico. Los humedales artificiales o sistemas pilotos, se encuentran ubicados en la universidad de Medellín y reciben una preparación de agua sintética, que asemeja a las características de un agua residual de origen doméstico. En el presente trabajo se evalúa el porcentaje de remoción de la carga orgánica de aguas residuales, en un sistema de tratamiento por humedales artificiales con dos especies vegetales. El sistema fue diseñado con tres módulos instalados de manera adjunta. En el primero no se integra ninguna especie vegetal, solo el medio de sustrato el cual constituye el blanco (-), en el segundo se integraron organismos de la especie vetiver (Chrysopogon zizanioides), en el tercer sistema piloto, organismos de la especie elefanta (Pennisetum purpureum) y en el cuarto organismos de la especie papiro japones (Cyperus alternifolius), los cuales constituyen el control positivo (+). Los módulos experimentales fueron limpiados, cortados y adecuados acorde al montaje inicial de las plantas y al espacio requerido para su disposición. A cada sistema piloto se le agrega medio de soporte constituido por grava (5 a 10 cm) y arena (15 a 20 cm), el sustrato es evaluado y caracterizado por su diámetro nominal, posterior en cada sistema se siembran las especies en un área de 3x3 y cada humedal por dos semanas se adecua bajo la solución de Hoagland y Arnon y régimen de humedad. En el agua sintética se analizaron los siguientes parámetros: pH, sólidos totales, sólidos suspendido totales, sólidos disueltos totales, demanda química de oxígeno (DQO), demanda bioquímica de oxígeno (DBO5), nitrógeno total (NTK) y fosforo total (PT). También se realizó la determinación del crecimiento de las plantas a partir del incremento de biomasa, porosidad de la raíz y de igual forma se determina NTK y PT. Los resultados demostraron que el sistema es una opción para la remoción de la carga orgánica y de nutrientes en aguas residuales de origen doméstico, de bajo costo de operación y mantenimiento, especialmente se observa que las plantas que crecen en sistemas de régimen de humedad ácuico y ústico, tienden a tener una mayor recepción y adaptación en los humedales artificiales pilotos, es el caso de la elefanta (Pennisetum purpureum), el cual presenta las más altas tasas de remoción de contaminantes y nutrientes en el afluente, seguido por el papiro japonés (Cyperus alternifolius) y el vetiver (Chrysopogon zizanioides), respecto a tasas de remoción. La remoción de contaminantes que se presentan más altos respectivamente, constituyen sólidos en primera instancia, seguido por la demanda bioquímica de oxigeno (DBO5), demanda química de oxígeno (DQO), nitrógeno total (NTK) y fósforo total (PT), estos últimos presentan una baja tasa de remoción, debido a la naturaleza misma del contaminante, a los organismos que realizan la remoción y absorción y al tiempo de retención que se elige, el cual influye en la tasa de remoción del contaminante siendo menor en la concentración de fósforo, pero se encuentranen el rango esperado para estos sistemas de tratamiento no convencionales.
Resumo:
The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.
Resumo:
Water treatment using photocatalysis has gained extensive attention in recent years. Photocatalysis is promising technology from green chemistry point of view. The most widely studied and used photocatalyst for decomposition of pollutants in water under ultraviolet irradiation is TiO2 because it is not toxic, relatively cheap and highly active in various reactions. Within this thesis unmodified and modified TiO2 materials (powders and thin films) were prepared. Physico-chemical properties of photocatalytic materials were characterized with UV-visible spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectrometry (XPS), inductively coupled plasma optical emission spectroscopy (ICP-OES), ellipsometry, time-of-flight secondary ion mass spectrometry (ToF-SIMS), Raman spectroscopy, goniometry, diffuse reflectance measurements, thermogravimetric analysis (TGA) and nitrogen adsorption/desorption. Photocatalytic activity of prepared samples in aqueous environment was tested using model compounds such as phenol, formic acid and metazachlor. Also purification of real pulp and paper wastewater effluent was studied. Concentration of chosen pollutants was measured with high pressure liquid chromatography (HPLC). Mineralization and oxidation of organic contaminants were monitored with total organic carbon (TOC) and chemical oxygen demand (COD) analysis. Titanium dioxide powders prepared via sol-gel method and doped with dysprosium and praseodymium were photocatalytically active for decomposition of metazachlor. The highest degradation rate of metazachlor was observed when Pr-TiO2 treated at 450ºC (8h) was used. The photocatalytic LED-based treatment of wastewater effluent from plywood mill using commercially available TiO2 was demonstrated to be promising post-treatment method (72% of COD and 60% of TOC was decreased after 60 min of irradiation). The TiO2 coatings prepared by atomic layer deposition technique on aluminium foam were photocatalytically active for degradation of formic and phenol, however suppression of activity was observed. Photocatalytic activity of TiO2/SiO2 films doped with gold bipyramid-like nanoparticles was about two times higher than reference, which was not the case when gold nanospheres were used.