952 resultados para centres educatius
Resumo:
There has been a growing interest in research on performance measurement and management practices, which seems to reflect researchers’ response to calls for the need to increase the relevance of management accounting research. However, despite the development of the new public management literature, studies involving public sector organizations are relatively small compared to those involving business organizations and extremely limited when it comes to public primary health care organizations. Yet, the economic significance of public health care organizations in the economy of developed countries and the criticisms these organizations regularly face from the public suggests there is a need for research. This is particularly true in the case of research that may lead to improvement in performance measurement and management practices and ultimately to improvements in the way health care organizations use their limited resources in the provision of services to the communities. This study reports on a field study involving three public primary health care organisations. The evidence obtained from interviews and archival data suggests a performance management practices in these institutions lacked consistency and coherence, potentially leading to decreased performance. Hierarchical controls seemed to be very weak and accountability limited, leading to a lack of direction, low motivation and, in some circumstances to insufficient managerial abilities and skills. Also, the performance management systems revealed a number of weaknesses, which suggests that there are various opportunities for improvement in performance in the studied organisations.
Resumo:
This paper describes an architecture conceived to integrate Power Sys-tems tools in a Power System Control Centre, based on an Ambient Intelligent (AmI) paradigm. This architecture is an instantiation of the generic architecture proposed in [1] for developing systems that interact with AmI environments. This architecture has been proposed as a consequence of a methodology for the inclu-sion of Artificial Intelligence in AmI environments (ISyRAmI - Intelligent Sys-tems Research for Ambient Intelligence). The architecture presented in the paper will be able to integrate two applications in the control room of a power system transmission network. The first is SPARSE expert system, used to get diagnosis of incidents and to support power restoration. The second application is an Intelligent Tutoring System (ITS) incorporating two training tools. The first tutoring tool is used to train operators to get the diagnosis of incidents. The second one is another tutoring tool used to train operators to perform restoration procedures.
Resumo:
Cyber-Physical Systems and Ambient Intelligence are two of the most important and emerging paradigms of our days. The introduction of renewable sources gave origin to a completely different dimension of the distribution generation problem. On the other hand, Electricity Markets introduced a different dimension in the complexity, the economic dimension. Our goal is to study how to proceed with the Intelligent Training of Operators in Power Systems Control Centres, considering the new reality of Renewable Sources, Distributed Generation, and Electricity Markets, under the emerging paradigms of Cyber-Physical Systems and Ambient Intelligence. We propose Intelligent Tutoring Systems as the approach to deal with the intelligent training of operators in these new circumstances.
Resumo:
The activity of Control Center operators is important to guarantee the effective performance of Power Systems. Operators’ actions are crucial to deal with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in tasks like incident analysis and diagnosis, and service restoration of Power Systems. Intelligent Tutoring System (ITS) approach is used in the training of the operators, taking into account context awareness and the unobtrusive integration in the working environment.
Resumo:
This article describes a new approach in the Intelligent Training of Operators in Power Systems Control Centres, considering the new reality of Renewable Sources, Distributed Generation, and Electricity Markets, under the emerging paradigms of Cyber-Physical Systems and Ambient Intelligence. We propose Intelligent Tutoring Systems as the approach to deal with the intelligent training of operators in these new circumstances.
Resumo:
According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 μm2/cm3. The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.
Resumo:
Fitness centres are special places where conditions for microbiological proliferation should be considered. Moisture due to human perspiration and water condensation as a result of human physical activities are prevalent in this type of buildings. Exposure to microbial contaminants is clinically associated with respiratory disorders and people who work out in polluted environments would be susceptible to contaminants. This work studied the indoor air contamination in three gymnasiums in Lisbon. The sampling was performed at two periods: at the opening (morning) and closing (night) of the three gymnasiums. The airborne bacterial and fungal populations were sampled by impaction directly onto Tryptic Soy Agar (for bacteria) and Malt Extract Agar (for fungi) plates, using a Merck MAS-100 air sampler. Higher bacterial concentrations were found at night as compared to the morning but the same behaviour was not found for fungal concentrations. Gram-negative catalase positive cocci were the dominant bacteria in indoor air samples of the studied gymnasiums. In this study, 21 genera/species of fungal colonies were identified. Chrysosporium sp., Chrysonilia sp., Neoscytalidium hialinum, Sepedonium sp. and Penicillium sp. were the most prevalent species identified in the morning, while Cladosporium sp., Penicillium sp., Chrysosporium sp., Acremonium sp. and Chrysonilia sp. were more prevalent at night. A well-designed sanitation and maintenance program for gymnasiums is needed to ensure healthier space for indoor physical activity.
Resumo:
According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.
Resumo:
The aim of this study was to undertake a comparative analysis of the practices and information behaviour of European information users who visit information units specialising in European information in Portugal and Spain. The study used a quantitative methodology based on a questionnaire containing closed questions and one open question. The questions covered the general sociological profile of the respondents and their use of European Document Centres, in addition to analysing aspects associated with information behaviour relating to European themes. The study therefore examined data on the preferred means and sources for accessing European information, types of documents and the subjects investigated most. The use of European databases and the Internet to access material on Europe was also studied, together with the reasons which users considered made it easy or difficult to access European information, and the aspects they valued most in accessing this information. The questionnaire was administered in European Document Centres in 2008 and 2010.
Resumo:
Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children’s respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening Windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.
Resumo:
Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children’s respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children’s health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC.
Resumo:
Modelling of ventilation is strongly dependent on the physical characteristics of the building of which precise evaluation is a complex and time consuming task. In the frame of a research project, two children day care centres (CDCC) have been selected in order to measure the envelope air permeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature. The data obtained was used as input to the computer code CONTAM for ventilation simulations. The results obtained were compared with direct measurements of ventilation flow from short term measurements with CO2 tracer gas and medium term measurements with perfluorocarbon tracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affect ventilation, the model was used to predict the ventilation rates for a wide range of conditions. The purpose of this assessment was to find the best practices to improve natural ventilation. A simple analytical method to predict the ventilation flow rate of rooms is also presented. The method is based on the estimation of wind effect on the room through the evaluation of an average factor and on the assessment of relevant cross section of gaps and openings combined in series or in parallel. It is shown that it may be applied with acceptable accuracy for this type of buildings when ventilation is due essentially to wind action.