918 resultados para air pollutant
Resumo:
Experimental studies on phase equilibria and liquidus in the multicomponent system PbO-ZnO-CaO-SiO2-FeO-Fe2O3 in air have been conducted over the temperature range between 1323 K (1050 degreesC) and 1623 K (1350 degreesC) to characterize the phase relations of the complex slag systems encountered in lead and zinc blast furnace sinters. The liquidus in two pseudoternary sections ZnO-Fe2O3-(PbO + CaO + SiO2) with the CaO/SiO2 weight ratio of 0.933 and PbO/(CaO + SiO2) weight ratios of 2.0 and 3.2 have been constructed.
Resumo:
O objetivo principal deste trabalho foi o estudo do transporte atmosférico de PM10 e SO2 em regiões costeiras urbanas usando modelos WRF/CMAQ. Duas regiões foram contempladas neste estudo. Uma é a Região da Grande Vitória (RGV), no estado do Espírito Santo, Brasil; a outra é a Região da Grande Dunkerque (RGD), no Departamento Nord Pas-de-Calais, França. A RGV é cercada por uma cadeia de montanhas paralela à costa, resultando num topografia complexa e acidentada. Já a RGD possui uma topografia muito mais suave. As entradas de dados para os modelos WRF/CMAQ englobaram o inventário de emissões de poluentes atmosféricos do IEMA-ES para a RGV, e o inventário de emissões no nível do solo de Nord Pas-de-Calais denominado ―Cadastre_totaux_3km_A2008 _M2010_V2_SNAPN2‖ para a RGD. Ambos os inventários apresentaram restrições, todavia. O inventário da RGV apresentou valores de ressuspensão em vias de tráfego elevados, em comparação com diversos estudos, e teve esses dados modificados. Os dados no nível do solo e a grande área de das células da grade (9 km2) do inventário da RGD não permitiram resultados satisfatórios de modelagem. A validação dos modelos foi realizada por comparação com resultados obtidos em duas campanhas experimentais: uma na cidade de Dunkerque, no norte da França, em setembro de 2009; a outra na cidade de Vitória, no sudeste do Brasil, em julho de 2012. Esses dados foram obtidos pelo uso de sistemas de Light Detection and Ranging (LIDAR) e Sonic Detection and Ranging (SODAR), bem como de Estações Meteorológicas de Superfície (EMS) e de monitoramento atmosférico. Os resultados deste trabalho mostraram que: a) existe uma necessidade de melhorias contínuas nos inventários regionais de emissões, adaptando-os para condições locais específicas e focando na obtenção de parâmetros necessários para modelagem fotoquímica; b) os valores de módulo e direção das velocidades obtidas na modelagem meteorológica influenciam fortemente os resultados da modelagem de concentração de poluentes; c) a qualidade do ar tanto na RGV quanto na RGD merece atenção, sobretudo no que diz respeito às concentrações de MP10. De acordo com os dados das estações de monitoramento, a situação parece mais crítica na RGD; d) a modelagem da RGV apresentou resultados mais satisfatórios do que a da RGD, de acordo com os resultados das validações; e) a entrada da brisa do mar provocou alterações significativas na concentração dos poluentes, o que pôde ser observado na análise da dinâmica da dispersão de MP10 e SO2. Esse fenômeno foi mais marcante na RGV, onde a entrada da brisa marítima provocou um movimento oscilatório na pluma de poluição, levando-a para os bairros mais densamente povoados do conglomerado urbano. Na RGD, a entrada da brisa não foi cotidiana e, no dia em que ela aconteceu, houve uma alteração de quase 180º na direção do movimento da pluma de poluição. Além do aumento da turbulência vertical, o qual já foi estudado por diversos autores, este estudo focou também na influência brisa do mar na dinâmica da pluma de dispersão de poluentes atmosféricos em regiões costeiras.
Resumo:
The European Union's (EU) decision to include aviation into the Emissions Trade Scheme was heatedly contested. Countries around the world, but mainly the Brazil, Russia, India, China and South Africa group (BRICS) and the US, denounced the EU's initiate as illegal and unilateral. Following a decade of frustrated negotiations at the International Civil Aviation Organization (ICAO), this paper interrogates why such measure, in principle climate-friendly, inspired so much global resentment. I argue that concerns with competitiveness and risks of legal inconsistency are important, but insufficient elements to explain the core of the conflict. The paper suggests that the EU was strongly criticized because third countries perceived this action as an imposed solution, which fostered an environment of distrust. Therefore, I claim that the problem has more to do with a normative divide than with a substantive divergence on what should be done regarding aviation emissions. My analysis is informed by the present literature on the links between trade and climate change, but gives particular weight to first-hand information through interviews with key stakeholders. The paper is divided in three parts. First, it presents the scope of the EU directive in historical perspective. Second, it explores the EU's measure through three different angles: legal, economical and political. The final part explores some possible solutions to overcome these divergences.
Resumo:
Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).
Resumo:
A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.
Resumo:
Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.
Resumo:
Introduction - Microscopic filamentous fungi, under suitable environmental conditions, can lead to the production of highly toxic chemical substances, commonly known as mycotoxins. The most widespread and studied mycotoxins are metabolites of some genera of moulds such as Aspergillus, Penicillium and Fusarium. Quite peculiar conditions may influence mycotoxin biosynthesis, such as climate, geographical location, cultivation practices, storage and type of substrate. Toxicity has been extensively investigated for the most important mycotoxins, such as aflatoxins, ochratoxin A and Fusarium toxins, and much information derived from toxicokinetics in animal models has also been obtained. The adverse effects are mainly related to genotoxicity, carcinogenicity, mutagenicity, teratogenicity and immunotoxicity. Aim of the study - To identify fungal species able to produce important mycotoxins in different Portuguese settings.
Resumo:
In this study, the results of chemical concentrations inside and outside of a Lisbon (Portugal) traffic tunnel were compared, during one week. They were obtained by Instrumental Neutron Activation Analysis (INAA). The tunnel values largely exceed the Air Ambient legislated values and the Pearson Correlations Coefficients point out to soil re-suspension/dispersed road dust (As, Ce, Eu, Hf, Fe, Mo, Sc, Zn), traffic-markers (Ba, Cr), tire wear (Cr, Zn), break wear (Fe, Zn, Ba, Cu, Sb), exhaust and motor oil (Zn) and sea-spray (Br, Na). On all days these elements inside the tunnel were more enriched than outside; significant statistical differences were found for Co (p=0.005), Br (p=0.008), Zn (p=0.01) and Sb (p=0.005), while enrichment factors of As and Sc are statistically identical. The highest values were found for As, Br, Zn and Sb, for both inside and outside the tunnel.
Resumo:
One Plus Sequential Air Sampler—Partisol was placed in a small village (Foros de Arrão) in central Portugal to collect PM10 (particles with an aerodynamic diameter below 10 μm), during the winter period for 3 months (December 2009–March 2010). Particles masses were gravimetrically determined and the filters were analyzed by instrumental neutron activation analysis to assess their chemical composition. The water-soluble ion compositions of the collected particles were determined by Ion-exchange Chromatography. Principal component analysis was applied to the data set of chemical elements and soluble ions to assess the main sources of the air pollutants. The use of both analytical techniques provided information about elemental solubility, such as for potassium, which was important to differentiate sources.
Resumo:
A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.
Resumo:
Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.
Resumo:
As ameaças à segurança da informação, (INFOSEC) atentam contra a perda da respectiva confidencialidade, integridade e disponibilidade, pelo que as organizações são impelidas a implementar políticas de segurança, quer ao nível físico quer ao nível lógico, utilizando mecanismos específicos de defesa. O projecto Network Air Gap Controller (NAGC) foi concebido no sentido de contribuir para as questões da segurança, designadamente daquelas que se relacionam directamente com a transferência de informação entre redes de classificação de segurança diferenciadas ou de sensibilidades distintas, sem requisitos de comunicação em tempo real, e que mereçam um maior empenho nas condições de robustez, de disponibilidade e de controlo. Os organismos que, em razão das atribuições e competências cometidas, necessitam de fazer fluir informação entre este tipo de redes, são por vezes obrigados a realizar a transferência de dados com recurso a um processo manual, efectuado pelo homem e não pela máquina, que envolve dispositivos amovivéis, como sejam o CD, DVD, PEN, discos externos ou switches manuais. Neste processo, vulgarmente designado por Network Air Gap (NAG), o responsável pela transferência de dados deverá assumir de forma infalível, como atribuições intrínsecas e inalienáveis da função exercida, as garantias do cumprimento de um vasto conjunto de normas regulamentares. As regras estabelecidas desdobram-se em ferramentas e procedimentos que se destinam, por exemplo, à guarda em arquivo de todas as transferências efectuadas; à utilização de ferramentas de segurança (ex: antivírus) antes da colocação da informação na rede de classificação mais elevada; ao não consentimento de transferência de determinados tipos de ficheiro (ex: executáveis) e à garantia de que, em consonância com a autonomia que normalmente é delegada no elemento responsável pela operação das comunicações, apenas se efectuam transferências de informação no sentido da rede de classificação inferior para a rede de classificação mais elevada. Face ao valor da informação e do impacto na imagem deste tipo de organizações, o operador de comunicações que não cumpra escrupulosamente o determinado é inexoravelmente afastado dessas funções, sendo que o processo de apuramento de responsabilidades nem sempre poderá determinar de forma inequívoca se as razões apontam para um acto deliberado ou para factores não intencionais, como a inépcia, o descuido ou a fadiga. Na realidade, as actividades periódicas e rotineiras, tornam o homem propenso à falha e poderão ser incontornavelmente asseguradas, sem qualquer tipo de constrangimentos ou diminuição de garantias, por soluções tecnológicas, desde que devidamente parametrizadas, adaptadas, testadas e amadurecidas, libertando os recursos humanos para tarefas de manutenção, gestão, controlo e inspecção. Acresce que, para este tipo de organizações, onde se multiplicam o número de redes de entrada de informação, com diferentes classificações e actores distintos, e com destinatários específicos, a utilização deste tipo de mecanismos assume uma importância capital. Devido a este factor multiplicativo, impõe-se que o NAGC represente uma opção válida em termos de oferta tecnológica, designadamente para uma gama de produtos de baixíssimo custo e que possa desenvolver-se por camadas de contributo complementar, em função das reais necessidades de cada cenário.