992 resultados para Zirconium-89
Resumo:
Gesellschaft ist ohne interaktiven Sprachgebrauch nicht möglich. Damit gehören Analysen des Sprachgebrauchs auch zu den wichtigen Themen der Ethnologie. An welchen theoretischen Vorstellungen aber kann man sich orientieren, um solche Analysen durchzuführen? Die theoretischen Vorstellungen, die für eine solche Analyse zweckdienlich sind, versuche ich in diesem Arbeitspapier aus verschiedenen Texten der Linguistik‚ der ethnography of speaking sowie der Ethnolinguistik zusammenzuführen und Lesern damit die Möglichkeit an die Hand zu geben, zahlreiche analytische Fragen an diesen Gegenstand zu stellen. Einen schnellen Zugriff auf diese unterschiedlichen Aspekte zu ermöglichen, ist der Sinn dieses Arbeitspapiers.
Resumo:
Implants made of commercially pure titanium (cpTi) are widely and successfully used in dentistry. For certain indications, diameter-reduced Ti alloy implants with improved mechanical strength are highly desirable. The aim was to compare the osseointegration of titanium-zirconium (TiZr) and cpTi implants with a modified sandblasted and acid-etched (SLActive) surface and with a Ti6Al4V alloy that was sand-blasted and acid-washed. Cylindrical implants with two, 0.75 mm deep, circumferential grooves were placed in the maxilla of miniature pigs and allowed to heal for 1, 2, 4 and 8 weeks. Undecalcified toluidine blue-stained ground sections were produced. Surface topography, area fraction of tissue components, and bone-to-implant contact (BIC) were determined. All materials showed significantly different surface roughness parameters. The amount of new bone within the implant grooves increased over time, without significant differences between materials. However, BIC values were significantly related to the implant material and the healing period. For TiZr and cpTi implants, the BIC increased over time, reaching values of 59.38 % and 76.15 % after 2 weeks, and 74.50 % and 84.67 % after 8 weeks, respectively. In contrast, the BIC for Ti6Al4V implants peaked with 42.29 % after 2 weeks followed by a decline to 28.60 % at 8 weeks. Significantly more surface was covered by multinucleated giant cells on Ti6Al4V implants after 4 and 8 weeks. In conclusion, TiZr and cpTi implants showed faster osseointegration than Ti6Al4V implants. Both chemistry and surface topography might have influenced the results. The use of diameter-reduced TiZr implants in more challenging clinical situations warrants further documentation in long-term clinical studies.
Resumo:
Giulio Cesare Aranzio in Italian (Julius Caesar Arantius in Latin) has not received full acclaim for his achievements in the field of anatomy and surgery that remain unknown to most physicians. His anatomical books Observationes Anatomicas, and De Humano Foetu Opusculum and surgical books De Tumoribus Secundum Locos Affectos and Hippocratis librum de vulneribus capitis commentarius brevis printed in Latin and additional existing literature on Aranzio from medical history books and journals were analysed extensively. Aranzio became Professor of Anatomy and Surgery at the University of Bologna in 1556. He established anatomy as a distinguished branch of medicine for the first time in medical history. Aranzio combined anatomy with a description of pathological processes. He discovered the 'Nodules of Aranzio' in the semilunar valves of the heart. He gave the first description of the superior levator palpebral and the coracobrachialis muscles. Aranzio wrote on surgical techniques for a wide spectrum of conditions that range from hydrocephalus, nasal polyp, goitre and tumours to phimosis, ascites, haemorrhoids, anal abscess and fistulae, and much more. Aranzio had an extensive knowledge in surgery and anatomy based in part on the ancient Greek and his contemporaries in the 16th century but essentially on his personal experience and practice.
Resumo:
Implants made from a new titanium-zirconium (TiZr) alloy (Roxolid) have shown good osseointegration with no adverse effects in animal studies. This single-cohort pilot study was performed to evaluate the performance and safe use of reduced-diameter implants made from this new TiZr alloy for the first time in human subjects, in a prospective case-controlled series.
Resumo:
A series of aluminum alloys containing additions of scandium, zirconium, and ytterbium were cast to evaluate the effect of partial ytterbium substitution for scandium on tensile behavior. Due to the high price of scandium, a crucible-melt interaction study was performed to ensure no scandium was lost in graphite, alumina, magnesia, or zirconia crucibles after holding a liquid Al-Sc master alloy for 8 hours at 900 °C in an argon atmosphere. The alloys were subjected to an isochronal aging treatment and tested for conductivity and Vickers microhardness after each increment. For scandium-containing alloys, peak hardnesses of 520-790 MPa, and peak tensile stresses of 138-234 MPa were observed after aging from 150-350 °C for 3 hours in increments of 50 °C, and for alloys without scandium, peak hardnesses of 217-335 MPa and peak tensile stresses of 45-63 MPa were observed after a 3 hour, 150 °C aging treatment. The hardness and tensile strength of the ytterbium containing alloy was found to be lower than in the alloy with no ytterbium substitution.
Resumo:
OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.
Resumo:
STATEMENT OF PROBLEM The increasing demand by patients for esthetic and metal-free restorations has driven the development of ceramic restorations with good esthetic and mechanical stability. Recent clinical studies have investigated the use of zirconium dioxide as a core material for complete crowns and computer-aided-design/computer-aided-manufacturing fabricated restorations. PURPOSE The aim of this systematic review was to evaluate the clinical survival rates of porcelain-fused-to-zirconia (PFZ) single crowns on anterior and posterior teeth and to compare them with metal ceramic (MC) crowns. MATERIAL AND METHODS A systematic search was conducted with PubMed and manual research to identify literature written in English that refers to in vivo studies published from January 1, 1950 through July 1, 2011. Clinical trials that evaluated PFZ and MC single crowns on natural teeth were selected for further analysis. Titles and/or abstracts of articles identified through the electronic searches were reviewed and evaluated for appropriateness. In addition, a hand search of relevant dental journals was peformed, and reference lists of culled articles were screened to identify publications. RESULTS The search resulted in a total of 488 initial matches. Nineteen studies with a total of 3621 crowns met the inclusion criteria. The survival rates of PFZ crowns (total 300) ranged from 92.7% to 100% for a follow-up time of 24 to 39 months, whereas those of MC crowns (total 3321) ranged from 70% to 100% for a follow-up time of 12 to 298 months. Studies that reported long-term results were found only for the MC crown group. CONCLUSIONS The scientific clinical data available to compare PFZ and MC crowns are limited. The survival rates may well be influenced by the selection and appropriate use of the veneering ceramic, and, therefore, additional prospective long-term clinical trials are necessary to draw reliable conclusions.
Resumo:
Background The use of cancer related therapy in cancer patients at the end-of-life has increased over time in many countries. Given a lack of published Swiss data, the objective of this study was to describe delivery of health care during the last month before death of cancer patients. Methods Claims data were used to assess health care utilization of cancer patients (identified by cancer registry data of four participating cantons), deceased between 2006-2008. Primary endpoints were hospitalization rate and delivery of cancer related therapies during the last 30 days before death. Multivariate logistic regression assessed the explanatory value of patient and geographic characteristics. Results 3809 identified cancer patients were included. Hospitalization rate (mean 68.5%, 95%CI 67.0-69.9) and percentage of patients receiving anti-cancer drug therapies (ACDT, mean 14.5%, 95%CI 13.4-15.6) and radiotherapy (mean 7.7%, 95%CI 6.7-8.4) decreased with age. Canton of residence and insurance type status most significantly influenced the odds for hospitalization or receiving ACDT. Conclusions The intensity of cancer specific care showed substantial variation by age, cancer type, place of residence and insurance type status. This may be partially driven by cultural differences within Switzerland and the cantonal organization of the Swiss health care system.
Resumo:
M. Appel
Resumo:
Owing to its single surgical intervention, immediate implant placement has the advantage of shortening treatment time, and thus positively affects patient morbidity. According to the bone resorption pattern after tooth extraction, bone loss should be anticipated if immediate implant placement is considered. The present case report aims to present a possible treatment option and to demonstrate that a partially edentulous arch may be rehabilitated esthetically by immediate implant placement and by corresponding anticipatory measures.
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.
Resumo:
The use of cancer-related therapies in cancer patients hospitalized at the end of life has increased in many countries over time. Given the scarcity of published Swiss data, the objective of this study was to evaluate the influence of hospital type and other factors on the delivery of health care during the last month before death. Claims data were used to assess health care utilization of cancer patients (identified by cancer registry data of four participating Swiss cantons) who deceased between 2006 and 2008. Primary endpoints were delivery of cancer-related therapies during the last 30 days before death. Multivariate logistic regression assessed the explanatory value of hospital type, patient and geographic characteristics. Of 3,809 identified cancer patients in the claims database, 2,086 patients dying from cancer were hospitalized during the last 30 days before death, generating 2,262 inpatient episodes. Anticancer drug therapy was given in 22.2% and radiotherapy in 11.7% of episodes. Besides age and cancer type, the canton of residence and hospital type showed independent, statistically significant associations with intensity of care, which was highest in university hospitals. These results should initiate a discussion among oncologists in Switzerland and may question the compliance with standard of care guidelines for terminal cancer patients.