935 resultados para Zinc oxide eugenol


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: Hydroxyl (OH(-)) and calcium (Ca(++)) ion release was evaluated in six materials: G1) Sealer 26, G2) White mineral trioxide aggregate (MTA), G3) Epiphany, G4) Epiphany + 10% calcium hydroxide (CH), G5) Epiphany + 20% CH, and G6) zinc oxide and eugenol. Material and Methods: Specimens were placed in polyethylene tubes and immersed in distilled water. After 3, 6, 12, 24, and 48 h, 7, 14, and 28 days, the water was assessed for pH with a pH meter and for Ca++ release by atomic absorption spectrophotometry. Results: G1, G2, G4, and G5 had the highest pH until 14 days (p < 0.05). G1 presented the highest Ca(++) release until 6 h, and G4 and G5, from 12 h through 14 days. Ca(++) release was greater for G1 and G2 at 28 days. G6 released the least Ca(++). Conclusions: MTA, Sealer 26, Epiphany, and Epiphany + CH release OH-and Ca(++) ions. Epiphany + CH may be an alternative as retrofilling material.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: To evaluate calcium ion release and pH of Sealer 26 (S26) (Dentsply, Rio de Janeiro, RJ, Brazil), white mineral trioxide aggregate (MTA), Endo CPM Sealer (CPM1) (EGEO SRL Bajo licencia MTM Argentina SA, Buenos Aires, Argentina), Endo CPM Sealer in a thicker consistency (CPM 2), and zinc oxide and eugenol cement (ZOE). Methods: Material samples (n = 10) were placed in polyethylene tubes and immersed in 10 mL of distilled water. After 3, 6,12,24, and 48 hours and 7,14, and 28 days, the water pH was determined with a pH meter, and calcium release was assessed by atomic absorption spectrophotometry. An empty tube was used as the control group. Results: The control group presented a pH value of 6.9 at all studied periods and did not show the presence of calcium ion. S26 presented greater hydroxyl ion release up to 12 hours (p < 0.05). From 24 hours until 28 days, S26, MTA, CPM1, and CPM2 had similar results. in ail periods, ZOE presented the lowest hydroxyl ion release. CPM1, followed by CPM2, released the most calcium ions until 24 hours (p < 0.05). Between 48 hours and 7 days, CPM1 and CPM2 had the highest release. A greater calcium ion release was observed for CPM2, followed by CPM1 at 14 days and for S26, CPM1, and CPM2 at 28 days. ZOE released the least calcium ions in all periods. Conclusion: Sealer 26, MTA, and Endo CPM sealer at normal or thicker consistency release hydroxyl and calcium ions. Endo CPM sealer may be an alternative as root-end filling material. (J Endod 2009;35:1418-1421)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate, by shear bond strength (SBS) testing, the influence of different types of temporary cements on the final cementation using conventional and self-etching resin-based luting cements. Material and Methods: Forty human teeth divided in two halves were assigned to 8 groups (n=10): I and V (no temporary cementation); II and VI: Ca(OH)(2)-based cement; III and VII: zinc oxide (ZO)based cement; IV and VIII: ZO-eugenol (ZOE)-based cement. Final cementation was done with RelyX ARC cement (groups I to IV) and RelyX Unicem cement (groups V to VIII). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Results: Means were (MPa): I - 3.80 (+/- 1.481); II - 5.24 (+/- 2.297); III - 6.98 (+/- 1.885); IV - 6.54 (+/- 1.459); V - 5.22 (+/- 2.465); VI - 4.48 (+/- 1.705); VII - 6.29 (+/- 2.280); VIII - 2.47 (+/- 2.076). Comparison of the groups that had the same temporary cementation (Groups II and VI; III and VII; IV and VIII) showed statistically significant difference (p<0.001) only between Groups IV and VIII, in which ZOE-based cements were used. The use of either Ca(OH) 2 based (Groups II and VI) or ZO-based (Groups III and VII) cements showed no statistically significant difference (p>0.05) for the different luting cements (RelyX (TM) ARC and RelyX (TM) Unicem). The groups that had no temporary cementation (Groups I and V) did not differ significantly from each other either (p>0.05). Conclusion: When temporary cementation was done with ZO- or ZOE-based cements and final cementation was done with RelyX ARC, there was an increase in the SBS compared to the control. In the groups cemented with RelyX Unicem, however, the use of a ZOE-based temporary cement affected negatively the SBS of the luting agent used for final cementation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The simultaneous formation of nanometer sized zinc oxide (ZnO), and acetate zinc hydroxide double salt (Zn-HDS) is described. These phases, obtained using the sol-gel synthesis route based on zinc acetate salt in alcoholic media, were identified by direct characterization of the reaction products in solution using complementary techniques: nephelometry, in situ Small-Angle X-ray Scattering (SAXS), UV-Vis spectroscopy and Extended X-ray Absorption Fine Structures (EXAFS). In particular, the hydrolytic pathway of ethanolic zinc acetate precursor solutions promoted by addition of water with the molar ratio N = [H2O]/[Zn2+] = 0.05 was investigated in this paper. The aim was to understand the formation mechanism of ZnO colloidal suspension and to reveal the factors responsible for the formation of Zn-HDS in the final precipitates. The growth mechanism of ZnO nanoparticles is based on primary particle (radius approximate to 1.5 nm) rotation inside the primary aggregate (radius < 3.5 nm) giving rise to an epitaxial attachment of particles and then subsequent coalescence. The growth of second ZnO aggregates is not associated with the Otswald ripening, and could be associated with changes in equilibrium between solute species induced by the superficial etching of Zn-HDS particles at the advanced stage of kinetic.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: The apical sealing ability of three different endodontic sealers was evaluated in extracted teeth using dye penetration. Methodology: The root canals of 99 extracted human maxillary central incisors were prepared sequentially 2 mm beyond the apical foramen with a size 55 Nitiflex file. The teeth were divided into three experimental groups and obturated by lateral condensation of cold gutta-percha and one of the following sealers: group 1, zinc oxide and eugenol sealer (Fill Canal); group 2, glass ionomer sealer (Ketac-Endo) and group 3, epoxy resin sealer (AH Plus). The teeth were covered with nail varnish to within 1 mm of the apical foramen and immersed in 2% methylene blue in a reduced pressure environment for 24h. After this period, the teeth were washed and cut longitudinally for apical leakage analysis. The values were obtained from the maximum depth of leakage as well as the average between the maximum and minimum values observed for each group. Results: Statistical evaluation of the results showed no significant difference in the leakage between Fill Canal and Ketac-Endo (P > 0.05). Leakage with AH Plus was significantly less (P < 0.01) than with the other sealers. Conclusions: All three sealers allowed some leakage to occur. Leakage with AH Plus was significantly different than with Fill Canal or Ketac-Endo.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

After filling root canals, the healing process depends on the chemical composition or physical-chemical properties of the material used, among other factors. All root canal sealers, whether solid or plastic, are foreign matter for the body if they remain in permanent contact with apical and periapical tissues. As a result, the first organic reaction that occurs is an attempt to phagocytize the material. During phagocytosis, macrophages release a large number of cell mediators into the area, among which are cytokines that are essential in intercellular communication and in many physiological and pathophysiological processes. One of these cytokines is tumor necrosis factor-alfa (TNF-α), which acts through links to specific receptors on the cell membrane initiating a cascade of events leading to induction, activation, or inhibition of numerous cytokine-regulated genes in the cell nucleus. The release of TNF-α in a cell culture of mouse peritoneal macrophages incubated with three concentrations (25, 50, and 100 mg/ml) of two endodontic sealers was measured. The solutions containing the calcium hydroxide-based root canal sealer (Sealapex) released fewer units of TNF-α than solutions containing the zinc oxide and eugenol-based sealer (Endomethasone).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A 90-day feeding experiment was conducted with sex reversed Nile tilapia (Oreochromis niloticus) fingerlings fed purified or practical diets supplemented with different zinc sources to evaluate fish growth performance and zinc and iron retention in fish bones, fillets, liver, skin and eyes. The relative bioavailability value (RBV) of zinc in the supplemental sources tested was also calculated. Fish were fed with isonitrogenous and isoenergetic purified or practical diets supplemented with 150 mg Zn kg -1, as zinc sulphate monohydrate (ZnSO 4), zinc oxide (ZnO) or zinc amino acid complex (Zn-AA). The feeding trial was conducted in 30, 50 L aquaria where four 0.66 ± 0.01 g (mean ± SD) fingerlings were initially stocked. No significant differences were observed for any growth performance variables (P > 0.05). In practical diets, only ZnSO 4 and ZnO presented bone zinc retention similar to that for the standard zinc source. Zinc concentration in the bone of fish fed practical diet supplemented with Zn-AA (171 ± 3.62 μg g -1) was significantly lower than that verified for the practical diets supplemented with the standard zinc source (200 ± 17.7 μg g -1) or with ZnSO 4 (204 ± 19.9 μg g -1). Assuming the concentration of zinc in bones as the response criterion, the supplemental zinc RBV from ZnSO 4 (105%) was higher than the RBV for Zn-AA (95.1%) or ZnO (94.9%). Iron concentration in the bones of animals fed the non-zinc-supplemented purified diet was significantly higher than that observed for purified diet supplemented with Zn-AA (P < 0,05). The results of the present work allowed us to conclude that ZnSO 4 in relation to ZnO or Zn-AA was the supplemental zinc source with higher zinc bioavailability to Nile tilapia. © 2005 Blackwell Publishing Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nile tilapia Oreochromis niloticus fingerlings were fed with purified or practical diets, supplemented with 150 Ing Zn/kg, from different sources. Dry matter (DM), crude protein (CP), ether extract (EE), and gross energy (GE) apparent digestibility coefficients (ADC), as well as zinc, copper, calcium, and phosphorus apparent absorption coefficients (AAC) were determined by the addition of 0.1% chromic oxide to the diets. The supplemental zinc sources utilized were commercial grade zinc sulfate monohydrate (ZnSO 4), zinc oxide (ZnO) and a zinc amino acid complex (Zn-AA). Analytical grade zinc sulfate heptahydrate was also utilized as a standard reference zinc source. There was a significant difference between purified (74.9%) and practical (41.3%) zinc AAC for the ZnO supplemented diets (P < 0.05). The supplemental zinc sources presented similar AAC when purified diets were utilized. However, ZnSO 4 was the best supplemental zinc source when practical type diets were used. There were no significant differences between supplemental zinc AAC from ZnS0 4 (68.9%), and supplemental zinc AAC from Zn-AA (61.3%) in practical diets, but Zn-AA diet showed a statistically lower zinc AAC when compared with the standard zinc source diet (75.6%). The practical diet supplemented with ZnO had the worst supplemental zinc AAC (41.3%). Dietary copper (74.21%), calcium (70.9%), and phosphorus (71.9%) AAC of the practical diets supplemented with ZnO were statistically lower (P < 0.05) than the respective AAC of the practical ZnSO 4 supplemented diets (83.6%, 84.1%, 87.1%).The ADC of the practical ZnO supplemented diet for DM (76.3%), CP (88.6%), EE (82.4%), and GE (81.6%) were statiscally lower than the respective ADC of the ZnSO 4 practical diet (86.0, 92.7, 93.6, 89.6%, respectively) and those ADC of the Zn-AA practical diet (84.7, 92.7, 93.7, 88.2%, respectively) (P < 0.05). Hence, these results indicate that ZnSO 4 and Zn-AA have equivalent intestinal absorption as supplemental zinc sources for Nile tilapia juveniles and both are superior to ZnO. © Copyright by the World Aquaculture Society 2005.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to evaluate the antimicrobial activity of different root-end filling materials - Sealer 26, Sealapex with zinc oxide, zinc oxide and eugenol, white and gray Portland cement, white and gray MTA-Angelus, and gray Pro Root MTA - against six different microorganism strains. The agar diffusion method was used. A base layer was made using Müller-Hinton agar (MH) and wells were formed by removing the agar. The materials were placed in the wells immediately after manipulation. The microorganisms used were: Micrococcus luteus (ATCC9341), Staphylococcus aureus (ATCC6538), Escherichia coli (ATCC10538), Pseudomonas aeruginosa (ATCC27853), Candida albicans (ATCC 10231), and Enterococcus faecalis (ATCC 10541). The plates were kept at room temperature for 2 h for prediffusion and then incubated at 37 degrees C for 24 h. Triphenyltetrazolium chloride 0.05% gel was added for optimization, and the zones of inhibition were measured. Data were subjected to the Kruskal-Wallis and Dunn tests at a 5% significance level. The results showed that all materials had antimicrobial activity against all the tested strains. Analysis of the efficacy of the materials against the microbial strains showed that Sealapex with zinc oxide, zinc oxide and eugenol and Sealer 26 created larger inhibition halos than the MTA-based and Portland cements (P < 0.05). On the basis of the methodology used, it may be concluded that all endodontic sealers, MTA-based and Portland cements evaluated in this study possess antimicrobial activity, particularly the endodontic sealers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Using the agar diffusion method, this study evaluated the in vitro antimicrobial activity of the commercial endodontic sealers Acroseal and Epiphany, a castor-oil based experimental sealer, Polifl, and a primer agent (Epiphany self-etching primer), against Enterococcus faecalis. Zinc oxide and eugenol cement (ZOE) served as control. Five wells per dish were made at equidistant points and immediately flled with the test and control materials. After incubation of the dishes at 37°C for 24 h and 48 h, the diameter of the zones of microbial growth inhibition produced around the wells was measured (in mm) with a millimeter rule. After 48 h, the diameters of the zones of microbial growth inhibition were the same as those observed at 24 h, only the substances continued to diffuse. Epiphany and Polifl did not show antibacterial activity (no formation of zones of microbial growth inhibition). The primer produced the largest zones of inhibition (17.62 mm) followed by Acroseal (7.25 mm) and ZOE (7.12 mm). E. faecalis was resistant to Epiphany and Polifl, while the primer and Acroseal sealer were effective against this microorganism under the tested conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Newly available materials for retrograde obturation should have their sealing properties evaluated. The goal of this study was to evaluate the sealing ability of Endo CPM sealer, an MTA-based endodontic cement. Single-rooted extracted human teeth were endodontically treated. After apical sectioning, retrograde cavities were prepared. Teeth were divided into five experimental groups (n=12), in which the following materials were used: Sealer 26 (S26), white Mineral Trioxide Aggregate (MTA), Endo CPM Sealer (CPM1), Endo CPM Sealer in thicker consistency (CPM 2), and zinc oxide and eugenol cement (ZOE), and two control groups (n=3). After retrograde obturation, the teeth were immersed in 0.2% rhodamine B dye for 48 hours in a vacuum chamber Marginal leakage data were subjected to ANOVA and Tukey tests at 5% significance level. S26 presented greater sealing ability (p<0.05) than ZOE, MTA, CPM1, and CPM2, all of which had similar results (p>0.05). We concluded that Sealer 26 has the greatest sealing ability. Endo CPM Sealer, with sealing ability similar to MTA, could be used as a retrograde obturation material.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This research was conducted with objective to evaluate the effect of different zinc (Zn) sources and doses in the diet for Santa Ines sheep. Forty lambs at weaning, with 18.4 kg of body weight were supplemented with three different sources of zinc (zinc oxide (ZnO), zinc amino acid and zinc proteinate) and three doses of zinc (200, 400 and 600 mg/kg DM) added to the basal diet. At every 28 days, animals were weighted and blood samples were collected for analyses of zinc (Zn), alkaline phosphatase and immunoglobulin G (IgG) and M (IgM). At the end of experiment, liver samples were collected for determination of the hepatic zinc levels. Zinc was analyzed with atomic absorption spectrophotometer, while phosphatase alkaline and immunoglobulins G and M were analyzed using Laborlab and Bioclin kits, respectively. There was no effect of diets on phosphatase alkaline levels and hepatic zinc, but there was difference in the plasmatic zinc levels and IgG and IgM levels. Based on the accumulation of hepatic zinc, the estimate of the zinc bioavailability, through the regression equation, showed that supplementation with organic and inorganic sources of zinc did not differ in the diet of Santa Ines sheep. © 2012 Sociedade Brasileira de Zootecnia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)