992 resultados para Wave Induced Forces
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
An all-fiber approach to terahertz generation using a periodically poled optical fiber is proposed and experimentally demonstrated. In the proposed approach, a continuous-wave THz wave is generated at a periodically poled fiber by beating two optical wavelengths from two laser sources with the wavelength spacing corresponding to the frequency of the THz wave. The key component in the system is the periodically poled fiber, which is made by a twin-hole fiber with the fiber core residing between two holes. The twin-hole fiber is then thermally poled at a temperature of similar to 260 degrees C with a voltage of 3.3 kV applied to the silver electrodes inside the two holes to introduce second-order nonlinearity. The quasi phase matching (QPM) condition is achieved by periodically erasing the thermal poling induced second-order nonlinearity with an ultraviolet laser, which enhances the energy conversion efficiency. The proposed approach is validated by an experiment. The emission of a THz wave centered at 3.8 THz with an output power of 0.5 mu W is observed. The frequency tunability between 2.2 and 3.8 THz is also experimentally demonstrated.
Resumo:
An analysis methodology is presented as well as a comparison of results obtained from vortex-induced motion (VIM) model tests of the MonoGoM platform, a monocolumn floating unit designed for the Gulf of Mexico. The choice of scale between the model and the platform in which the tests took place was a very important issue that took into account the basin dimensions and mooring design. The tests were performed in three different basins: the IPT Towing Tank in Brazil (Sept. 2005), the NMRI Model Ship Experimental Towing Tank in Japan (Mar. 2007), and the NMRI Experimental Tank in Japan (Jun. 2008). The purpose is to discuss the most relevant issues regarding the concept, execution, and procedures to comparatively analyze the results obtained from VIM model tests, such as characteristic motion amplitudes, motion periods, and forces. The results pointed out the importance of considering the 2DOF in the model tests, i.e., the coexistence of the motions in both in-line and transverse directions. The approach employed in the tests was designed to build a reliable data set for comparison with theoretical and numerical models for VIM prediction, especially that of monocolumn platforms. [DOI: 10.1115/1.4003494]
Resumo:
Experimental results of flow around a circular cylinder with moving surface boundary-layer control (MSBC) are presented. Two small rotating cylinders strategically located inject momentum in the boundary layer of the cylinder, which delays the separation of the boundary layer. As a consequence, the wake becomes narrower and the fluctuating transverse velocity is reduced, resulting in a recirculation free region that prevents the vortex formation. The control parameter is the ratio between the tangential velocity of the moving surface and the flow velocity (U-c/U). The main advantage of the MSBC is the possibility of combining the suppression of vortex-induced vibration (VIV) and drag reduction. The experimental tests are preformed at a circulating water channel facility and the circular cylinders are mounted on a low-damping air bearing base with one degree-of-freedom in the transverse direction of the channel flow. The mass ratio is 1.8. The Reynolds number ranges from 1600 to 7500, the reduced velocity varies up to 17, and the control parameter interval is U-c/U = 5-10. A significant decreasing in the maximum amplitude of oscillation for the cylinder with MSBC is observed. Drag measurements are obtained for statically mounted cylinders with and without MSBC. The use of the flow control results in a mean drag reduction at U-c/U = 5 of almost 60% compared to the plain cylinder. PIV velocity fields of the wake of static cylinders are measured at Re = 3000. The results show that the wake is highly organized and narrower compared to the one observed in cylinders without control. The calculation of the total variance of the fluctuating transverse velocity in the wake region allows the introduction of an active closed-loop control. The experimental results are in good agreement with the numerical simulation studies conducted by other researchers for cylinders with MSBC. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Corrole and four of its isomers with subtle structural changes promoted by exchange of nitrogen and carbon atoms in the corrole ring have been studied by traveling wave ion mobility mass spectrometry and collision induced dissociation experiments. Significant differences in shapes and charge distributions for their protonated molecules were found to lead to contrasting gas phase mobilities, most particularly for corrorin, the most "confused" isomer. Accordingly, corrorin was predicted by B3LYP/6-31g(d,p) and collisional cross section calculations to display the most compact tri-dimensional structure, whereas NCC4 and corrole were found to be the most planar isomers. Better resolution between the corrole isomers was achieved using the more polarizable and massive CO2 as the drift gas. Sequential losses of HF molecules were found to dominate the dissociation chemistry of the protonated molecules of these corrole isomers, but their unique structures caused contrasting labilities towards CID, whereas NCC4 showed a peculiar and structurally diagnostic loss of NH3, allowing its prompt differentiation from the other isomers.
Resumo:
An experimental study on Vortex-Induced Motion (VIM) of the semi-submersible platform concept with four square columns is presented. Model tests were carried out to check the influence of different headings and hull appendages (riser supports located at the pontoons; fairleads and the mooring stretches located vertically at the external column faces; and hard pipes located vertically at the internal column faces). The results comprise in-line, transverse and yaw motions, as well as combined motions in the XY plane, drag and lift forces and spectral analysis. The main results showed that VIM in the transverse direction occurred in a range of reduced velocity 4.0 up to 14.0 with amplitude peaks around reduced velocities around 7.0 and 8.0. The largest transverse amplitudes obtained were around 40% of the column width for 30 degrees and 45 degrees incidences. Another important result observed was a considerable yaw motion oscillation, in which a synchronization region could be identified as a resonance phenomenon. The largest yaw motions were verified for the 0 degrees incidence and the maxima amplitudes around 4.5 degrees. The hull appendages located at columns had the greatest influence on the VIM response of the semi-submersible. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Travelling wave ion mobility mass spectrometry (TWIM-MS) with post-TWIM and pre-TWIM collision-induced dissociation (CID) experiments were used to form, separate and characterize protomers sampled directly from solutions or generated in the gas phase via CID. When in solution equilibria, these species were transferred to the gas phase via electrospray ionization, and then separated by TWIM-MS. CID performed after TWIM separation (post-TWIM) allowed the characterization of both protomers via structurally diagnostic fragments. Protonated aniline (1) sampled from solution was found to be constituted of a ca. 5:1 mixture of two gaseous protomers, that is, the N-protonated (1a) and ring protonated (1b) molecules, respectively. When dissociated, 1a nearly exclusively loses NH3, whereas 1b displays a much diverse set of fragments. When formed via CID, varying populations of 1a and 1b were detected. Two co-existing protomers of two isomeric porphyrins were also separated and characterized via post-TWIM CID. A deprotonated porphyrin sampled from a basic methanolic solution was found to be constituted predominantly of the protomer arising from deprotonation at the carboxyl group, which dissociates promptly by CO2 loss, but a CID-resistant protomer arising from deprotonation at a porphyrinic ring NH was also detected and characterized. The doubly deprotonated porphyrin was found to be constituted predominantly of a single protomer arising from deprotonation of two carboxyl groups. Copyright (C) 2012 John Wiley & Sons, Ltd.
Resumo:
Vortex-Induced Vibration (VIV) experiments were carried out with yawed cylinders. The purpose was to investigate the validity of the Independence Principle (IP) for properly describing the flow characteristics and the dynamics of structures subjected to oblique flow. Five yaw angles in relation to the direction perpendicular to the free stream velocity were tested, namely View the MathML sourceθ=0°,10°,20°,30° and 45°. Both the upstream and downstream orientations were tested. The models were mounted on a leaf spring apparatus that allows experiments with one or two degrees of freedom. The Reynolds numbers based on the component normal to the cylinder axis fell in the interval 3×103
Resumo:
Introduzione. Le cellule mesenchimali derivate dal tessuto adiposo (hASC) rappresentano un importante strumento per la terapia cellulare, in quanto derivano da un tessuto adulto abbondante e facilmente reperibile. Con il dispositivo medico Lipogems l’isolamento di tali cellule è eseguito esclusivamente mediante sollecitazioni meccaniche. Il prodotto ottenuto è quindi minimamente manipolato e subito utilizzabile. Ad oggi, il condizionamento pro-differenziativo delle staminali è per lo più attuato mediante molecole di sintesi. Tuttavia, altri fattori possono modulare la fisiologia cellulare, come gli stimoli fisici e molecole naturali. Onde elettromagnetiche hanno indotto in modelli cellulari staminali l’espressione di alcuni marcatori di differenziamento e, in cellule adulte, una riprogrammazione, mentre estratti embrionali di Zebrafish sono risultati antiproliferativi sia in vitro che in vivo. Metodi. La ricerca di nuove strategie differenziative sia di natura fisica che molecolare, nel particolare onde acustiche ed estratti embrionali di Zebrafish, è stata condotta utilizzando come modello cellulare le hASC isolate con Lipogems. Onde acustiche sono state somministrate mediante l’utilizzo di due apparati di trasduzione, un generatore di onde meccaniche e il Cell Exciter . I trattamenti con gli estratti embrionali sono stati effettuati utilizzando diverse concentrazioni e diversi tempi sperimentali. Gli effetti sull’espressione dei marcatori di staminalità e differenziamento relativi ai trattamenti sono stati saggiati in RT-PCR quantitativa relativa e/o in qPCR. Per i trattamenti di tipo molecolare è stata valutata anche la proliferazione. Risultati e conclusioni. La meta-analisi dei dati delle colture di controllo mostra la stabilità d’espressione genica del modello. I trattamenti con i suoni inducono variazioni dell’espressione genica, suggerendo un ruolo regolatorio di tali stimoli, in particolare del processo di commitment cardiovascolare. Due degli estratti embrionali di Zebrafish testati inibiscono la proliferazione alle 72 ore dalla somministrazione. L’analisi d’espressione associata ai trattamenti antiproliferativi suggerisce che tale effetto abbia basi molecolari simili ai processi di differenziamento.
Resumo:
Fine powders commonly have poor flowability and dispersibility due to interparticle adhesion that leads to formation of agglomerates. Knowing about adhesion in particle collectives is indispensable to gain a deeper fundamental understanding of particle behavior in powders. Especially in pharmaceutical industry a control of adhesion forces in powders is mandatory to improve the performance of inhalation products. Typically the size of inhalable particles is in the range of 1 - 5 µm. In this thesis, a new method was developed to measure adhesion forces of particles as an alternative to the established colloidal probe and centrifuge technique, which are both experimentally demanding, time consuming and of limited practical applicability. The new method is based on detachment of individual particles from a surface due to their inertia. The required acceleration in the order of 500 000 g is provided by a Hopkinson bar shock excitation system and measured via laser vibrometry. Particle detachment events are detected on-line by optical video microscopy. Subsequent automated data evaluation allows obtaining a statistical distribution of particle adhesion forces. To validate the new method, adhesion forces for ensembles of single polystyrene and silica microspheres on a polystyrene coated steel surface were measured under ambient conditions. It was possible to investigate more than 150 individual particles in one experiment and obtain adhesion values of particles in a diameter range of 3 - 13 µm. This enables a statistical evaluation while measuring effort and time are considerably lower compared to the established techniques. Measured adhesion forces of smaller particles agreed well with values from colloidal probe measurements and theoretical predictions. However, for the larger particles a stronger increase of adhesion with diameter was observed. This discrepancy might be induced by surface roughness and heterogeneity that influence small and large particles differently. By measuring adhesion forces of corrugated dextran particles with sizes down to 2 µm it was demonstrated that the Hopkinson bar method can be used to characterize more complex sample systems as well. Thus, the new device will be applicable to study a broad variety of different particle-surface combinations on a routine basis, including strongly cohesive powders like pharmaceutical drugs for inhalation.
Resumo:
Trauma or degenerative diseases such as osteonecrosis may determine bone loss whose recover is promised by a "tissue engineering“ approach. This strategy involves the use of stem cells, grown onboard of adequate biocompatible/bioreabsorbable hosting templates (usually defined as scaffolds) and cultured in specific dynamic environments afforded by differentiation-inducing actuators (usually defined as bioreactors) to produce implantable tissue constructs. The purpose of this thesis is to evaluate, by finite element modeling of flow/compression-induced deformation, alginate scaffolds intended for bone tissue engineering. This work was conducted at the Biomechanics Laboratory of the Institute of Biomedical and Neural Engineering of the Reykjavik University of Iceland. In this respect, Comsol Multiphysics 5.1 simulations were carried out to approximate the loads over alginate 3D matrices under perfusion, compression and perfusion+compression, when varyingalginate pore size and flow/compression regimen. The results of the simulations show that the shear forces in the matrix of the scaffold increase coherently with the increase in flow and load, and decrease with the increase of the pore size. Flow and load rates suggested for proper osteogenic cell differentiation are reported.
Resumo:
Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays.
Resumo:
Background. Several factors are implicated in renal stone formation and peak incidence of renal colic admissions to emergency departments (ED). Little is known about the influence of potential environmental triggers such as lunar gravitational forces. We conducted a retrospective study to test the hypothesis that the incidence of symptomatic renal colics increases at the time of the full and new moon because of increased lunar gravitational forces. Methods. We analysed 1500 patients who attended our ED between 2000 and 2010 because of nephrolithiasis-induced renal colic. The lunar phases were defined as full moon ± 1 day, new moon ± 1 day, and the days in-between as "normal" days. Results. During this 11-year period, 156 cases of acute nephrolithiasis were diagnosed at the time of a full moon and 146 at the time of a new moon (mean of 0.4 per day for both). 1198 cases were diagnosed on "normal" days (mean 0.4 per day). The incidence of nephrolithiasis in peak and other lunar gravitational phases, the circannual variation and the gender-specific analysis showed no statistically significant differences. Conclusion. In this adequate powered longitudinal study, changes in tractive force during the different lunar phases did not influence the incidence of renal colic admissions in emergency department.