927 resultados para WASTE POLLUTION
Resumo:
This study presents novel evidence that N-15 natural abundance can be used as a robust indicator to detect pollutant nitrogen in natural plant communities. Vegetation from the heavily polluted industrial area of Cubatao in Sao Paulo State, SE Brazil, was strongly N-15 depleted compared to plants at remote sites. Historic herbarium samples from Cubatao were significantly less N-15 depleted than extant plants, indicating that N-15 depletion of vegetation is associated with present-day nitrogen pollution in Cubatao. The heavy load of nitrogenous atmospheric pollutants in Cubatao provides a nitrogen source for plants, and strongly N-15 depleted air NH3 is likely to contribute to plant and soil N-15 depletion. Epiphytic plants from Cubatao were extremely N-15 depleted (average -10.9parts per thousand) contrasting with epiphytes at remote sites (averages -1.0parts per thousand and -3.0parts per thousand). Nitrogen isotope composition of vegetation provides a tool to determine input of pollutant nitrogen into plant communities. The strong isotopic change of epiphytes suggests that epiphytes are particularly sensitive biomonitors for atmospheric pollutant nitrogen.
Resumo:
Low-density lipoprotein oxidation is implicated in the development of atherosclerosis. Plasma susceptibility to oxidation may be used as a marker of low-density lipoprotein oxidation and thus predict atherosclerotic risk. In this study the authors investigated the relationship between plasma susceptibility to oxidation and exposure to automotive pollution in a group of automobile mechanics (n = 16) exposed to high levels of automotive pollution, vs. matched controls (n = 13). The authors induced plasma oxidation by a free radical initiator and they determined susceptibility to oxidation by (1) change in absorbance at 234 nm, (2) lag time to conjugated diene formation, and (3) linear slope of the oxidation curve. Mechanics had significantly higher values (mean standard error) for change in absorbance (1.60 +/- 0.05 vs. 1.36 +/- 0.05; p < .002), and slope (1.6 x 10(-3) +/- 0.1 x 10(-3) vs. 1.3 x 10(-3) +/- 0.1 x 10(-3); p < .001), compared with controls. These results indicate that regular exposure to automotive pollutants increases plasma susceptibility to oxidation and may, in the long term, increase the risk of developing atherosclerosis.
Resumo:
In this study, the results of chemical concentrations inside and outside of a Lisbon (Portugal) traffic tunnel were compared, during one week. They were obtained by Instrumental Neutron Activation Analysis (INAA). The tunnel values largely exceed the Air Ambient legislated values and the Pearson Correlations Coefficients point out to soil re-suspension/dispersed road dust (As, Ce, Eu, Hf, Fe, Mo, Sc, Zn), traffic-markers (Ba, Cr), tire wear (Cr, Zn), break wear (Fe, Zn, Ba, Cu, Sb), exhaust and motor oil (Zn) and sea-spray (Br, Na). On all days these elements inside the tunnel were more enriched than outside; significant statistical differences were found for Co (p=0.005), Br (p=0.008), Zn (p=0.01) and Sb (p=0.005), while enrichment factors of As and Sc are statistically identical. The highest values were found for As, Br, Zn and Sb, for both inside and outside the tunnel.
Resumo:
Since industrialization and the formation of larger urban centers in the nineteenth century, pollution of the environment was always present in daily life in various ways, namely in the form of light. Light pollution can cause various consequences, both for humans and for their ecosystem, producing effects on environmental, social, economic and scientific level. In Portugal, the lighting is responsible for 3% of total electricity consumption, energy costs are in some cases more than 50% towards the costs incurred by municipalities with energy, checking-in recent years a trend similar to that improvement of illumination levels in the region (about 4 to 5% per year). Proper use of lighting brings many benefits both to the citizen and environment, since greater energy efficiency can contribute to reducing CO2 emissions, energy costs, as well as to decrease the use of resources not-renewable and/or contamination of renewable resources, which can occurs in the process of obtaining electricity. The present study has a main goal to analyze the illuminance levels associated to the public lighting of the village of Vialonga, Vila Franca de Xira (Portugal), to verify if it is efficient. The aim is also to relate the efficiency of street lighting with the existence of light pollution.
Resumo:
The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 μm2/cm3, which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) μm have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.
Resumo:
The present paper shows preliminary results of an ongoing project which one of the goals is to investigate the viability of using waste FCC catalyst (wFCC), originated from Portuguese oil refinery, to produce low carbon blended cements. For this purpose, four blended cements were produced by substituting cement CEM I 42.5R up to 20% (w/w) by waste FCC catalyst. Initial and final setting times, consistency of standard paste, soundness and compressive strengths after 2, 7 and 28 days were measured. It was observed that the wFCC blended cements developed similar strength, at 28 days, compared to the reference cement, CEM I 42.5R. Moreover, cements with waste FCC catalyst incorporation up to 15% w/w meet European Standard EN 197-1 specifications for CEM II/A type cement, in the 42.5R strength class.
Resumo:
There are complex and diverse methodological problems involved in the clinical and epidemiological study of respiratory diseases and their etiological factors. The association of urban growth, industrialization and environmental deterioration with respiratory diseases makes it necessary to pay more attention to this research area with a multidisciplinary approach. Appropriate study designs and statistical techniques to analyze and improve our understanding of the pathological events and their causes must be implemented to reduce the growing morbidity and mortality through better preventive actions and health programs. The objective of the article is to review the most common methodological problems in this research area and to present the most available statistical tools used.
Resumo:
Cooking was found to be a main source of submicrometer and ultrafine aerosols from gas combustion in stoves. Therefore, this study consisted of the determination of the alveolar deposited surface area due to aerosols resulting from common domestic cooking activities (boiling fish, vegetables, or pasta, and frying hamburgers and eggs). The concentration of ultrafine particles during the cooking events significantly increased from a baseline of 42.7 μm2/cm3 (increased to 72.9 μm2/cm3 due to gas burning) to a maximum of 890.3 μm2/cm3 measured during fish boiling in water, and a maximum of 4500 μm2/cm3 during meat frying. This clearly shows that a domestic activity such as cooking can lead to exposures as high as those of occupational exposure activities.
Resumo:
In the management of solid waste, pollutants over a wide range are released with different routes of exposure for workers. The potential for synergism among the pollutants raises concerns about potential adverse health effects, and there are still many uncertainties involved in exposure assessment. In this study, conventional (culture-based) and molecular real-time polymerase chain reaction (RTPCR) methodologies were used to assess fungal air contamination in a waste-sorting plant which focused on the presence of three potential pathogenic/toxigenic fungal species: Aspergillus flavus, A. fumigatus, and Stachybotrys chartarum. In addition, microbial volatile organic compounds (MVOC) were measured by photoionization detection. For all analysis, samplings were performed at five different workstations inside the facilities and also outdoors as a reference. Penicillium sp. were the most common species found at all plant locations. Pathogenic/toxigenic species (A. fumigatus and S. chartarum) were detected at two different workstations by RTPCR but not by culture-based techniques. MVOC concentration indoors ranged between 0 and 8.9 ppm (average 5.3 ± 3.16 ppm). Our results illustrated the advantage of combining both conventional and molecular methodologies in fungal exposure assessment. Together with MVOC analyses in indoor air, data obtained allow for a more precise evaluation of potential health risks associated with bioaerosol exposure. Consequently, with this knowledge, strategies may be developed for effective protection of the workers.
Resumo:
Research on the use of Construction and Demolition Waste (CDW) as recycled aggregate (in particular crushed concrete) for the production of new concrete has by now established the feasibility of this environmentally-friendly use of otherwise harmful waste. However, contrary to conventional concrete (CC), no large applications of concrete made with recycled concrete have been made and there is still a lack of knowledge in some areas of production and performance of recycled aggregate concrete (RAC). One issue concerns curing conditions: these greatly affect the performance of concrete made on site and some potential users of RAC wonder how RAC is affected by far-from-ideal curing conditions. This paper shows the main results of experiments to determine the influence of different curing conditions on the mechanical performance of concrete made with coarse recycled aggregate from crushed concrete. The properties analyzed include compressive strength, splitting tensile strength, modulus of elasticity, and abrasion resistance. The general conclusion in terms of mechanical performance is that RAC is affected by curing conditions roughly in the same way as CC. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
A existência de estações de tratamentos de águas residuais (ETAR) é, nos dias de hoje, fundamental na medida em que permite, reduzir a poluição ambiental associada às águas e, também, a reutilização da água tratada para diversos fins. A constante necessidade de cumprir os limites de descargas nos meios recetores conduziu a um melhoramento nas técnicas e processos de tratamento de efluentes, nomeadamente, nos processos biológicos. O processo por lamas ativadas é um processo amplamente utilizado para a remoção de poluentes orgânicos presentes nas águas residuais, pelo que um estudo mais intensivo sobre estes tratamentos resultou na publicação de uma série de conceitos e pressupostos, através de modelos numéricos. A modelação numérica de processos de tratamento de águas residuais e a utilização de ferramentas de simulação numérica têm sido largamente utilizadas, a nível mundial, por exemplo em investigação, desenvolvimento de processos, atividade de consultoria e igualmente por entidades reguladoras, na medida em que os auxiliam no planeamento, dimensionamento e análise do comportamento de infraestruturas de tratamento. No presente trabalho, recorreu-se ao software de simulação GPS-X (versão 6.0) para implementar o esquema de tratamento da ETAR de Beirolas. O objetivo deste trabalho é verificar a aplicabilidade de modelos numéricos na simulação de unidades de tratamento de efluentes e avaliar a resposta dos diferentes modelos, assim como a influência na alteração de características das águas afluentes no comportamento dos modelos. Os resultados obtidos permitiram concluir que os modelos numéricos podem ser utilizados para prever a resposta dos sistemas biológicos e as suas perturbações. Conclui-se ainda que o comportamento, dos modelos estudados (ASM1, ASM2d, ASM3 e mantis), é semelhante, contudo deve-se referir que devido à complexidade do modelo e a falta de informação experimental sobre as características do efluente, não permitiram efetuar uma completa caracterização e calibração do caso de estudo, e toda a informação disponível sobre as características físico-químicas da água foram baseadas em estimativas de concentrações de carências de oxigénio e sólidos suspensos.
Resumo:
OBJECTIVE: Myocardial infarction is an acute and severe cardiovascular disease that generally leads to patient admissions to intensive care units and few cases are initially admitted to infirmaries. The objective of the study was to assess whether estimates of air pollution effects on myocardial infarction morbidity are modified by the source of health information. METHODS: The study was carried out in hospitals of the Brazilian Health System in the city of São Paulo, Southern Brazil. A time series study (1998-1999) was performed using two outcomes: infarction admissions to infirmaries and to intensive care units, both for people older than 64 years of age. Generalized linear models controlling for seasonality (long and short-term trends) and weather were used. The eight-day cumulative effects of air pollutants were assessed using third degree polynomial distributed lag models. RESULTS: Almost 70% of daily hospital admissions due to myocardial infarction were to infirmaries. Despite that, the effects of air pollutants on infarction were higher for intensive care units admissions. All pollutants were positively associated with the study outcomes but SO2 presented the strongest statistically significant association. An interquartile range increase on SO2 concentration was associated with increases of 13% (95% CI: 6-19) and 8% (95% CI: 2-13) of intensive care units and infirmary infarction admissions, respectively. CONCLUSIONS: It may be assumed there is a misclassification of myocardial infarction admissions to infirmaries leading to overestimation. Also, despite the absolute number of events, admissions to intensive care units data provides a more adequate estimate of the magnitude of air pollution effects on infarction admissions.
Resumo:
Marble processing activities generates a.significant amount of waste in dust form. This waste, which is nowadays one of the environmental problems worldwide, presents great potential of being used as mineral addition in blended cements production. This paper shows preliminary results of an ongoing project which ultimate goal is to investigate the viability of using waste marble dust (WMD), produced by marble Portuguese industry, as cement replacement material. In order to evaluate the effects of the WMD on mechanical behaviour, different mortar blended cement mixtures were tested. These mixtures were prepared with different partial substitution level of cement with WMD. Strength results of WMD blended cements were compared to control cements with same level of incorporation of natural limestone used to produce commercial Portland-limestone cements. The results obtained show that WMD blended cements perform better than limestone blended cements for same replacement level up to 20% w/w. Therefore, WMD reveals promising attributes for blended cements production.
Resumo:
OBJECTIVE: To assess the lag structure between air pollution exposure and elderly cardiovascular diseases hospital admissions, by gender. METHODS: Health data of people aged 64 years or older was stratified by gender in São Paulo city, Southeastern Brazil, from 1996 to 2001. Daily levels of air pollutants (CO, PM10, O3, NO2, and SO2) , minimum temperature, and relative humidity were also analyzed. It were fitted generalized additive Poisson regressions and used constrained distributed lag models adjusted for long time trend, weekdays, weather and holidays to assess the lagged effects of air pollutants on hospital admissions up to 20 days after exposure. RESULTS: Interquartile range increases in PM10 (26.21 mug/m³) and SO2 (10.73 mug/m³) were associated with 3.17% (95% CI: 2.09-4.25) increase in congestive heart failure and 0.89% (95% CI: 0.18-1.61) increase in total cardiovascular diseases at lag 0, respectively. Effects were higher among female group for most of the analyzed outcomes. Effects of air pollutants for different outcomes and gender groups were predominately acute and some "harvesting" were found. CONLUSIONS: The results show that cardiovascular diseases in São Paulo are strongly affected by air pollution.