940 resultados para Triple endoscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the production of three gauge bosons (W(+)W(-)Z(0) and W(+)W(-)gamma) at the next generation of linear e(+)e(-) colliders operating in the yy mode. We analyze the total cross sections as well as several kinematical distributions of the final state particles. We find out that a linear e(+)e(-) machine operating in the rr mode will produce 5-10 times more three-gauge-boson states compared to the standard e(+)e(-) mode at high energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study in a model independent way the role of a techniomega resonance in the process e+e-→ W+W-Z at the Next Linear Collider. © 1998 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We derive bounds on Higgs and gauge-boson anomalous interactions using the CDF data for the process pp̄ → γγγ + X. We use a linearly realized SU L(2) X U Y(1) invariant effective Lagrangian to describe the bosonic sector of the Standard Model, keeping the fermionic couplings unchanged. All dimension-six operators that lead to anomalous Higgs interactions involving γ and Z are considered. We also show the sensitivity that can be achieved for these couplings at Fermilab Tevatron upgrades. © 1998 Published by Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We update the indirect bounds on anomalous triple gauge couplings coming from the non-universal one-loop contributions to the Z → bb width. These bounds, which are independent of the Higgs boson mass, are in agreement with the standard model predictions for the gauge boson self-couplings since the present value of R(b) agrees fairly well with the theoretical estimates. Moreover, these indirect constraints on Δg(Z)/1 and g(Z)/5 are most stringent than the present direct bounds on these quantities, while the indirect limit on λ(Z) is weaker than the available experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two auxiliary methods of diagnosing nasopharyngeal airway obstruction were compared. Cephalometric radiography and nasopharyngeal videoendoscopy were evaluated for efficacy in terms of reproducibility and validity. Thirty orthodontic patients (7 to 12 years of age) seeking otorhinolaryngologic treatment for mouth breathing, or mouth and nose breathing, had nasopharyngeal endoscopy and radiographic examinations performed on the same day. Two otorhinolaryngologists analyzed the results. Nasopharyngeal endoscopy was more reliable in identifying all the obstructive nasopharyngeal processes. Endoscopy obtained kappa index scores of almost perfect agreement for diagnosis of posterior nasal septum deviation, of substantial agreement for anterior nasal septum deviation and lower turbinate hypertrophy, and of moderate agreement for middle turbinate hypertrophy. Lateral cephalometric radiography obtained scores of perfect agreement for imaging hypertrophy of the middle turbinate, of almost perfect agreement for imaging hypertrophy of the posterior portion of the inferior turbinate, and of substantial agreement for imaging hypertrophy of the inferior turbinate. Radiographic diagnoses of hypertrophy of the middle and lower turbinates exhibited high sensitivity and low specificity when compared with diagnoses by nasopharyngeal endoscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a case report of a 39-year-old black woman, nulliparous, married who presented a heavy menstrual flow with clots and dysmenorrhea. Gynaecological examination of the uterus revealed RVF, mobility, no pain, slight enlargement, and right displacement. Magnetic resonance imaging (MRI) of the pelvis showed a 40 mm submucous fibroid with intramural component less than 50%, type 1, with a 3 mm distance from serosa. In an office hysteroscopy, it was noted a 40 mm submucous fibroid with an intramural component with less than 50%, type 1, classified in STEP-W submucous fibroids classification as a Score 6, Group II. The patient was submitted to partial hysteroscopic myomectomy, removing 60% of the fibroid volume in a 48.75-minute surgery. GnRH analogue was indicated for 3 months before another intervention. In the second evaluation MRI revealed a 22 mm-fibroid with intramural component more than 50%, type 2, with a 7 mm distance from serosa. Hysteroscopy found a 20 mm submucous fibroid, with intramural component more than 50%, type 2, Score 4, Group I on STEP-W classification. The patient was submitted to a second hysteroscopic myomectomy with complete removal and 10.5 minutes operating time, without complications. © 2006 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a case report of a 27-year-old white woman, nuliparous, single, who presented a heavy menstrual flow with clots, dysmenorrhoea and anaemia. Gynaecological examination of the uterus revealed anteverted position, mobility, no pain, slight enlargement and right displacement. Magnetic resonance imaging of the pelvis showed a 29-mm submucous fibroid with intramural component more than 50%, type 2, in the posterior wall, with a 5-mm distance from serosa. In office hysteroscopy, a 30-mm submucous fibroid with an intramural component with more than 50%, type 2, near around 5 mm from left tubal ostia, classified in STEP-W submucous fibroids classification as score 6, group II, was noted. GnRH analogue was indicated for 3 months before intervention to treat anaemia. The patient was submitted to hysteroscopic myomectomy with direct mobilisation technique, with the fibroid completely removed without complications in a surgery which lasted for 52 min and 20 s. © 2008 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2001 SN263 is a triple system asteroid. Although it was discovery in 2001, in 2008 astronomical observation carried out by Arecibo observatory revealed that it is actually a system with three bodies orbiting each other. The main central body is an irregular object with a diameter about 2.8 km, while the other two are small objects with less than 1 km across. This system presents an orbital eccentricity of 0.47, with perihelion of 1.04 and aphelion of 1.99, which means that it can be considered as a Near Earth Object. This interesting system was chosen as the target for the Aster mission - first Brazilian space exploration undertaking. A small spacecraft with 150 kg of total mass, 30 kg of payload with 110 W available for the instruments, is scheduled to be launched in 2015, and in 2018 it will approach and will be put in orbit of the triple system. This spacecraft will use electric propulsion and in its payload it will carry image camera, laser rangefinder, infrared spectrometer, mass spectrometer, and experiments to be performed in its way to the asteroid. This mission represents a great challenge for the Brazilian space program. It is being structured to allow the full engagement of the Brazilian universities and technological companies in all the necessary developments to be carried out. In this paper, we present some aspects of this mission, including the transfer trajectories to be used, and details of buss and payload subsystems that are being developed and will be used. Copyright ©2010 by the International Astronautical Federation. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho faz uma análise de desempenho de aplicações triple play através da tecnologia Power Line Communication, fazendo uma abordagem direcionada para qualidade de serviço e qualidade de experiência. Apresenta resultados obtidos em cenários residenciais onde o uso desta tecnologia como última milha mostra-se uma solução passível de implementação diante dos testes realizados com transmissões de chamadas VoIP, transmissões de vídeo em alta definição e dados. O conceito de rede doméstica, interligando todos os pontos de uma casa, vem representando um novo rumo na definição de um padrão global, no qual a transmissão de dados por meio da fiação elétrica será uma das tecnologias empregadas e de maior destaque. Também será mostrado o desempenho das métricas avaliadas como jitter, largura de banda, perda de pacotes, PSNR, MOS, VQM, SSIM e suas correlações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)