903 resultados para Tratamento de águas residuais


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Patologia - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objeto da presente patente é um reator fotoeletrocatalítico operando com eletrodos nanoporosos ou nanotubulares de Ti/TiO~ 2~ como fotoanodos, uma rede de platina como cátodo para oxidação fotoeletrocatalítica de efluentes coloridos, sob densidade de corrente constante e irradiação de luz UV, utilizado no tratamento de águas de rejeito contendo corantes ácidos, básicos, dispersos, reativos e agentes dispersantes e efluentes coletados de indústrias têxteis. Ambos os eletrodos mostraram uma performance acima dos métodos usuais removendo não apenas a coloração, mas processando grande mineralização dos diversos tipos de corantes, surfactantes etc. em efluentes da industria têxtil.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O presente trabalho teve como objetivo estudar a qualidade e a variabilidade de águas pluviais escoadas e armazenadas. Foram realizadas análises estatísticas descritivas, correlacionais e de componentes principais. As coletas de águas pluviais foram feitas nas dependências da Universidade Estadual Paulista Júlio de Mesquita Filho, situada no campus de Rio Claro. Para este estudo, foram utilizadas amostras de 43 precipitações, coletadas entre março de 2010 e abril de 2012. Os resultados apontam que a concepção de sistemas de tratamento de águas pluviais deve ser realizada considerando a grande variabilidade de qualidade entre eventos de chuva. Os resultados da análise de componentes principais indicam que a grande variabilidade das águas pluviais coletadas é influenciada, sobretudo, pela deposição de sólidos durante o período de estiagem e pela decomposição de matéria orgânica, requerendo tecnologias de operação flexíveis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The volume of liquid effluent generated in cattle slaughterhouses is quite high and cannot be released untreated in water bodies due to its high pollution load of predominantly organic origin. To minimize the environmental impacts of its industrial wastewater and meet the local environmental legislation, abattoirs shall make the treatment of these effluents. The present work aims to develop the study of a reactor by sequential batch pilot scale, in order to optimize their performance in treating wastewater from a cattle slaughterhouse. The treatment system used was developed and installed in the Laboratory of Wastewater Treatment, in Faculty of Science and Technology UNESP, Presidente Prudente campus. The procedure used followed the operation of sequential batch reactors, in which all processes and treatment operations occurring sequentially in a single unit, by establishing specific operating cycles, which comprise the following separated phases: aerobic reaction, anoxic reaction, sedimentation and emptying. Aiming to improve the quality of treatment was planned the addition of coagulant Poly Aluminum Chloride (PAC) in the reactor, by determining their optimal dosage by Jar-test trials. Were prepared four steps with specific operating cycles: step one or acclimatization (10 hour of aeration, one hour and 30 minutes of sedimentation and 30 minutes for exchanging the effluent); step 2 (6 hours of aeration or aerobic phase, 4 hours and 45 minutes of stirring or anoxic phase and 1 hour and 15 minutes for sedimentation and exchange effluent); step 3 (2 hours and 30 minutes of aeration, 8 hours and 15 minutes of stirring and 1 hour and 15 minutes for sedimentation and exchange) and step 4 (2 hours of aeration, 8 hours and 45 minutes of stirring and 1 hour and 15 minutes for sedimentation and exchange)... (Complete abstract click electronic access below)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Este trabalho objetivou analisar a qualidade da água de três córregos tributários do rio Bauru, levando em conta a poluição causada por produtos orgânicos e industriais que vinham sendo descartados nos mesmos e as eventuais melhorias conseqüentes das medidas paliativas assumidas pelo DAE-Bauru, mediante a instalação de interceptores-coletores de águas residuárias ao longo Daqueles corpos de água, até que a Estação de Tratamento de Esgotos do município seja construída e se dê início ao seu funcionamento. O monitoramento destes corpos de água durante o período de estiagem e de cheias proposto nesta pesquisa, incluiu investigações sobre as variáveis químicas e físicas de amostras das águas, obtidas mensalmente em 7 pontos de coleta, localizados a montante e a jusante dos pontos de instalação dos emissários, ao longo dos córregos. As amostras de água foram posteriormente analisadas para fossem obtidas informações sobre a eficácia da instalação dos interceptores com relação ao processo de recuperação da saúde dos corpos aquáticos em questão. Os resultados obtidos mostraram que, de um modo geral, as águas de todos os sistemas estudados ainda sofrem impactos, até porque ainda há aquelas que recebem o esgoto descartado “in natura”. No entanto, como ja era esperado, nos pontos de coleta localizados em segmentos dos córregos nos quais os emissários já foram instalados, o impacto ambiental é menor. Mediante a comparação dos resultados obtidos das análises das características físicas e químicas das águas dos sistemas estudados realizadas durante esta investigação com aqueles obtidos nos mesmos corpos de água, em 2007, pudemos observar melhorias da água em alguns dos pontos de coleta