805 resultados para Thick lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive measurements of the age dependence of refractive index distribution in human eye lenses in vitro using a novel X-ray Talbot Interferometry method. In their paper, the authors make frequent reference to our own work in which we employed magnetic resonance imaging (MRI) to make similar non-invasive measurements of the refractive index distribution in the human eye lens [2, 3]. Prior to the current work, ours was the only method for making such measurements both non-invasively and without prior assumptions about the shape of the refractive index distribution. For this reason, the latest work is to be welcomed. However at several points in the paper, Pierscionek et al. [1] make statements about our technique which are factually incorrect...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design is ubiquitous to the life of contemporary societies and key to their progress, but for some, it is an elitist concept. This thesis investigates the role of public libraries contribution to the general public's understanding of 'Design'. This study compared participants views in the context of State Libraries in two cities: Brisbane and Curitiba. Findings revealed that exploring four new aspects in the Development and Deliver Stages of a service design framework for public libraries can be an effective tool to enhance people's access and experiences of Design, and ultimately, it can contribute to the democratization of design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To quantify the influence of short-term wear of miniscleral contact lenses on the morphology of the corneo-scleral limbus, the conjunctiva, episclera and sclera. METHODS OCT images of the anterior eye were captured before, immediately following 3h of wear and then 3h after removal of a miniscleral contact lens for 10 young (27±5 years) healthy participants (neophyte rigid lens wearers). The region of analysis encompassed 1mm anterior, to 3.5mm posterior to the scleral spur. Natural diurnal variations in thickness were measured on a separate day and compensated for in subsequent analyses. RESULTS Following 3h of lens wear, statistically significant tissue thinning was observed across all quadrants, with a mean decrease in thickness of -24.1±3.6μm (p<0.001), which diminished, but did not return to baseline 3h after lens removal (-16.9±1.9μm, p<0.001). The largest tissue compression was observed in the superior quadrant (-49.9±8.5μm, p<0.01) and in the annular zone 1.5mm from the scleral spur (-48.2±5.7μm), corresponding to the approximate edge of the lens landing zone. Compression of the conjunctiva/episclera accounted for about 70% of the changes. CONCLUSIONS Optimal fitting miniscleral contact lenses worn for three hours resulted in significant tissue compression in young healthy eyes, with the greatest thinning observed superiorly, potentially due to the additional force of the eyelid, with a partial recovery of compression 3h after lens removal. Most of the morphological changes occur in the conjunctiva/episclera layers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design is ubiquitous to the life of contemporary societies and key to their progress, but for some, it is an elitist concept. This thesis investigates the role of public libraries contribution to the general public's understanding of "Design". This study compared participants views in the context of State Libraries in two cities: Brisbane and Curitiba. Findings revealed that exploring four new aspects in the Development and Deliver Stages of a service design framework for public libraries can be an effective tool to enhance people"s access and experiences of Design, and ultimately, it can contribute to the democratisation of design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using Social Practice Wisdom (SPW) as a conceptual lens, we shed new light on destructive, selfish leadership and its negative effects. Our study highlights the negative effects on followers of leaders' selfishness, as well as lack of empathy and inauthenticity. Our work also sheds light on new cross-cultural leadership challenges in emerging economies like Indonesia. Analysis reveals deep tensions between Indonesian leaders' tendency to position themselves in self-serving discourses of feudalism and family, and what young, western educated Indonesian professionals now expect of leaders. Selfish leadership discourse and lack of leader wisdom jeopardize Indonesia's economic development. We argue that wise dialogical communication enhances wise leadership.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To quantify regional (nasal, superior, temporal and inferior) and location specific (corneal and scleral) tissue compression following short-term miniscleral contact lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exact solution for the stresses in a transversely isotropic infinite thick plate having a circular hole and subjected to axisymmetric uniformly distributed load on the plane surfaces has been given. The solution is in the form of Fourier-Bessel series and integrals. Numerical results for the stresses are given using the elastic constants for magnesium, and are compared with the isotropic case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a solution for the determination of stresses and displacements in a thick plate having a cylindrical hole subjected to localised hydrostatic loading has been given. Detail numerical results have been presented and compared with the results of an infinite hole subjected to localised hydrostatic load and a semiinfinite hole subjected to localised end load. It has been shown that for certain ratio of thickness of the pate to the radius of the hole and loading, the results could be obtained by using the solution of infinite or semiinfinite hole subjected to the same hydrostatic loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissatisfaction with, and discontinuation from, contact lens wear is a source of major frustration and inconvenience to users, and a problem that is thought to cost the contact lens industry hundreds of millions of dollars each year. By directly and non-invasively monitoring inflammatory cells in the tissues at the front of the eye in symptomatic and asymptomatic lens wearers, the candidate has been able to demonstrate an inflammatory basis for contact lens discomfort. This finding may pave the way towards the development of strategies to make contact lenses more safe and afford greater levels of comfort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exact theoretical solution is given for the stresses and displacements in an infinite plate of finite thickness having a circular hole and subjected to axisymmetric normal leading. The solution is given in the form of Fourier-Bessel series and integral. Numerical results are given for stresses in plates having different thickness to hole diameter ratios and loadings. The results are compared with the available approximate theoretical and experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new 8-node serendipity quadrilateral plate bending element (MQP8) based on the Mindlin-Reissner theory for the analysis of thin and moderately thick plate bending problems using Integrated Force Method is presented in this paper. The performance of this new element (MQP8) is studied for accuracy and convergence by analyzing many standard benchmark plate bending problems. This new element MQP8 performs excellent in both thin and moderately thick plate bending situations. And also this element is free from spurious/zero energy modes and free from shear locking problem.