863 resultados para Technological tests
Resumo:
Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores - Área de Especialização de Telecomunicações
Resumo:
A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.
Resumo:
This paper presents the creation and development of technological schools directly linked to the business community and to higher public education. Establishing themselves as the key interface between the two sectors they make a signigicant contribution by having a greater competitive edge when faced with increasing competition in the tradional markets. The development of new business strategies supported by references of excellence, quality and competitiveness also provides a good link between the estalishment of partnerships aiming at the qualification of education boards at a medium level between the technological school and higher education with a technological foundation. We present a case study as an example depicting the success of Escola Tecnológica de Vale de Cambra.
Resumo:
Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.
Resumo:
An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.
Resumo:
This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.
Resumo:
This paper refers to the assessment on site by semi-destructive testing (SDT) methods of the consolidation efficiency of a conservation process developed by Henriques (2011) for structural and non-structural pine wood elements in service. This study was applied on scots pine wood (Pinus sylvestris L.) degraded by fungi after treatment with a biocidal product followed by consolidation with a polymeric product. This solution avoids substitutions of wood moderately degraded by fungi, improving its physical and mechanical characteristics. The consolidation efficiency was assessed on site by methods of drill resistance and penetration resistance. The SDT methods used showed good sensitivity to the conservation process and could evaluate their effectiveness. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
This paper is about a design of an urban area Darrieus VAWT, having self-start ability due to an innovative profile design named EN0005, avoiding the need of extra components or external electricity feed-in. An approach is presented to study the ability of a blade profile to offer self-start ability. Methodologies applied for the blade body and for profile development are reported. Field tests and main conclusions are presented to persuade for the arrangement of this design. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Task scheduling is one of the key mechanisms to ensure timeliness in embedded real-time systems. Such systems have often the need to execute not only application tasks but also some urgent routines (e.g. error-detection actions, consistency checkers, interrupt handlers) with minimum latency. Although fixed-priority schedulers such as Rate-Monotonic (RM) are in line with this need, they usually make a low processor utilization available to the system. Moreover, this availability usually decreases with the number of considered tasks. If dynamic-priority schedulers such as Earliest Deadline First (EDF) are applied instead, high system utilization can be guaranteed but the minimum latency for executing urgent routines may not be ensured. In this paper we describe a scheduling model according to which urgent routines are executed at the highest priority level and all other system tasks are scheduled by EDF. We show that the guaranteed processor utilization for the assumed scheduling model is at least as high as the one provided by RM for two tasks, namely 2(2√−1). Seven polynomial time tests for checking the system timeliness are derived and proved correct. The proposed tests are compared against each other and to an exact but exponential running time test.
Resumo:
Master Thesis to obtain the Master degree in Chemical Engineering - Branch Chemical Processes
Resumo:
The choice of an information systems is a critical factor of success in an organization's performance, since, by involving multiple decision-makers, with often conflicting objectives, several alternatives with aggressive marketing, makes it particularly complex by the scope of a consensus. The main objective of this work is to make the analysis and selection of a information system to support the school management, pedagogical and administrative components, using a multicriteria decision aid system – MMASSITI – Multicriteria Method- ology to Support the Selection of Information Systems/Information Technologies – integrates a multicriteria model that seeks to provide a systematic approach in the process of choice of Information Systems, able to produce sustained recommendations concerning the decision scope. Its application to a case study has identi- fied the relevant factors in the selection process of school educational and management information system and get a solution that allows the decision maker’ to compare the quality of the various alternatives.
Resumo:
O principal motivo para a realização deste trabalho consistiu no desenvolvimento de tecnologia robótica, que permitisse o mergulho e ascenção de grandes profundidades de uma forma eficiente. O trabalho realizado contemplou uma fase inicial de análise e estudo dos sistemas robóticos existentes no mercado, bem como métodos utilizados identificando vantagens e desvantagens em relação ao tipo de veículo pretendido. Seguiu-se uma fase de projeto e estudo mecânico, com o intuito de desenvolver um veículo com variação de lastro através do bombeamento de óleo para um reservatório exterior, para variar o volume total do veículo, variando assim a sua flutuabilidade. Para operar a grande profundidade com AUV’s é conveniente poder efetuar o trajeto up/down de forma eficiente e a variação de lastro apresenta vantagens nesse aspeto. No entanto, contrariamente aos gliders o interesse está na possibilidade de subir e descer na vertical. Para controlar a flutuabilidade e ao mesmo tempo analisar a profundidade do veículo em tempo real, foi necessario o uso de um sistema de processamento central que adquirisse a informação do sensor de pressão e comunicasse com o sistema de variação de lastro, de modo a fazer o controlo de posicionamento vertical desejado. Do ponto de vista tecnológico procurou-se desenvolver e avaliar soluções de variação de volume intermédias entre as dos gliders (poucas gramas) e as dos ROV’s workclass (dezenas ou centenas de kilogramas). Posteriormente, foi desenvolvido um simulador em matlab (Simulink) que reflete o comportamento da descida do veículo, permitindo alterar parâmetros do veículo e analisar os seus resultados práticos, de modo a poder ajustar o veículo real. Nos resultados simulados verificamos o cálculo das velocidades limite atingidas pelo veículo com diferentes coeficientes de atrito, bem como o comportamento da variação de lastro do veículo no seu deslocamento vertical. Sistema de Variação de Lastro para Controlo de Movimento Vertical de Veículo Subaquático Por fim, verificou-se ainda a capacidade de controlo do veículo para uma determinada profundiade, e foi feita a comparação entre estas simulações executadas com parâmetros muito próximos do ensaio real e os respetivos ensaios reais.
Resumo:
To determine the rabies antibody level of twenty-four hyperimmune equine sera, Standard Mouse Neutralization (SMN) and Couterimmunoelectrophoresis (CIE) tests were carried out, both at the Instituto Butantan (IB) and Instituto Panamericano de Protección de Alimentos y Zoonosis (INPPAZ). Statistical analysis has shown a correlation (r) of 0.9317 between the SMN and CIE performed at the IB, while at the INPPAZ it scored 0.974. Comparison of CIE data of both laboratories yielded a correlation of 0.845. The CIE technique has shown to be as sensitive and efficient as the SMN in titrating antirabies hyperimmune equine sera. Based on CIE results, a simple, rapid and inexpensive technique, tilers of sera antibody can be reliably estimated in SMN test.
Resumo:
Crude Toxoplasma gondii antigens represent raw material used to prepare reagents to be employed in different serologic tests for the diagnosis of toxoplasmosis, including the IgM and IgG indirect hemagglutination (IgG-HA and IgM-HA) tests. So far, the actual antigenic molecules of the parasite involved in the interaction with agglutinating anti-T. gondii antibodies in these tests are unknown. The absorption process of serum samples from toxoplasmosis patients with the IgG-HA reagent (G-toxo-HA) demonstrated that red cells from this reagent were coated with T. gondii antigens with Mr of 39, 35, 30, 27, 22 and 14 kDa. The immune-absorption process with the IgM-HA reagent (M-toxo-HA), in turn, provided antibody eluates which recognized antigenic bands of the parasite corresponding to Mr of 54, 35 and 30 kDa, implying that these antigens are coating red cells from this reagent. The identification of most relevant antigens for each type of HA reagent seems to be useful for the inspection of the raw antigenic material, as well as of reagent batches routinely produced. Moreover the present findings can be used to modify these reagents in order to improve the performance of HA tests for the diagnosis of toxoplasmosis