186 resultados para TAPER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Analogue and finite element numerical models with frictional and viscous properties are used to model thrust wedge development. Comparison between model types yields valuable information about analogue model evolution, scaling laws and the relative strengths and limitations of the techniques. Both model types show a marked contrast in structural style between ‘frictional-viscous domains’ underlain by a thin viscous layer and purely ‘frictional domains’. Closely spaced thrusts form a narrow and highly asymmetric fold-and-thrust belt in the frictional domain, characterized by in-sequence propagation of forward thrusts. In contrast, the frictional-viscous domain shows a wide and low taper wedge and a thrust belt with a more symmetrical vergence, with both forward and back thrusts. The frictional-viscous domain numerical models show that the viscous layer initially simple shears as deformation propagates along it, while localized deformation resulting in the formation of a pop-up structure occurs in the overlying frictional layers. In both domains, thrust shear zones in the numerical model are generally steeper than the equivalent faults in the analogue model, because the finite element code uses a non-associated plasticity flow law. Nevertheless, the qualitative agreement between analogue and numerical models is encouraging. It shows that the continuum approximation used in numerical models can be used to model frictional materials, such as sand, provided caution is taken to properly scale the experiments, and some of the limitations are taken into account.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Texas State Department of Highways and Public Transportation, Transportation Planning Division, Austin

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Texas Department of Transportation, Austin

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Texas Department of Transportation, Austin

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Salivary cortisol (C) and DHEA concentrations were measured in 9 elite swimmers (4 female and 5 male) over a 37-week period, 5 to 12 times per swimmer, before 68 competitions. For female and male swimmers, no significant relationship was found between C, DHEA and performance. For the whole group, C was negatively correlated with week number of training (r = -0.31, p < 0.01). The incorporation of the cumulated distance swum as a second variable in the regression increased r to 0.56 (p < 0.01). The higher the cumulated distance swum, the higher C. No significant relationship was found between DHEA and distance swum. For individual swimmers, 3 of 4 females showed a significant negative relationship between C and cumulated dry-land training. No equivalent relationship was found for DHEA. The 2 males practicing dry-land training showed a significant and negative relationship between DHEA and cumulated dry-land training. No equivalent relationship was found for C. Thus, C and DHEA were not good predictors of swimming performance. C for individual females, and DHEA for individual males were considered useful markers for dry-land training stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A single long-period fibre grating was written in a biconical fibre taper made from standard communications step-index optical fibre, resulting in an interferometric fibre sensor device that provided a resolution of 1×10–4 for refractive indices in the range of 1.30 to 1.34, suggesting that these devices may be suitable for use with aqueous solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A single long-period fibre grating was written in a biconical fibre taper made from standard communications step-index optical fibre, resulting in an interferometric fibre sensor device that provided a resolution of 1 × 10-4 for refractive indices in the range of 1.30 to 1.34, suggesting that these devices may be suitable for use with aqueous solutions. © IEE 2005.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new fibre Mach-Zehnder type based on a single LPG written in a biconical fibre taper is presented alongside a theoretical model supporting the observed effect

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Long period grating was UV inscribed into a multicore fiber consisting of 120 single mode cores. The multicore fiber that hosts the grating was fusion spliced into a single mode fiber at both ends. The splice creates a taper transition between the two types of fiber that produces a nonadiabatic mode evolution; this results in the illumination of all the modes in the multicore fiber. The spectral characteristics of this fiber device as a function of curvature were investigated. The device yielded a significant spectral sensitivity as high as 1.23 nm/m-1 and 3.57 dB/m-1 to the ultra-low curvature values from 0 to 1 m-1. This fiber device can also distinguish the orientation of curvature experienced by the fiber as the long period grating attenuation bands producing either a blue or red wavelength shift. The finite element method (FEM) model was used to investigate the modal behavior in multicore fiber and to predict the phase-matching curves of the long period grating inscribed into multicore fiber. © 2014 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose and demonstrate a microfiber Fabry-Perot interferometer (MFPI) fabricated by taper-drawing microfiber at the center of a uniform fiber Bragg grating (FBG). The MFPI employing the two separated sections of FBG as reflectors and a length of microfiber as its cavity is derived. Theoretic study shows that the reflection spectrum of such MFPI is consisted of two parts-interference fringes induced by multi-beam interference and reflection spectrum envelope induced by FBGs. Temperature affects both interference fringes and reflection wavelength of FBGs while ambient refractive index (RI) only influences the interference fringes, i.e., MFPI has different response to temperature and RI. Therefore, MFPI for simultaneous sensing of RI and temperature is experimentally demonstrated by tracking a reflection peak of interference fringes and the Bragg wavelength of the FBGs, which are respectively assisted by frequency domain processing and Gaussian fitting of the optical spectrum. Consequently, wavelength measurement resolution of 0.5 pm is realized. © 1983-2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The general aim of this study was to evaluate the conical interface of pilar/implant. The specific aims were to evaluate the influence of hexagonal internal index in the microleakage and mechanical strength of Morse taper implants; the effect of axial loading on the deformation in cervical region of Morse taper implants of different diameters through strain gauge; the effect of axial loading in cervical deformation and sliding of abutment into the implant by tridimensional measurements; the integrity of conical interface before and after dynamic loading by microscopy and microleakage; and the stress distribution in tridimensional finite element models of Morse taper implants assembled with 2 pieces abutment. According to the obtained results, could be concluded that the diameter had influence in the cervical deformation of Morse taper implants; the presence of internal hexagonal index in the end of internal cone of implant didn´t influenced the bacterial microleakage under static loading neither reduced the mechanical strength of implants; one million cycles of vertical and off-center load had no negative influence in Morse taper implant integrity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Several theories, such as the biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, and the periimplant stress/strain concentration causing bone microdamage accumulation, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim: to evaluate clinical, bacteriological, and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Materials and methods: Twelve patients with totally edentulous mandibles received four custom made Ø 3.8 x 13 mm implants in the interforaminal region of the mandible, with the same design, but different prosthetic connections (two of them EH or MT, randomly placed based on a split-mouth design), and a immediate implant- supported prosthesis. Clinical parameters (periimplant probing pocket depth, modified gingival index and mucosal thickness) were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6 and 12 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tanerella forsythia, Porphyromonas gingivalis, Aggragatibacter actinomycetemcomitans, Prevotella intermedia and Fusobacterium nucleatum. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t- test. Further, 36 computer-tomographic based finite element (FE) models were accomplished, simulating each patient in 3 loading conditions. The results for the peak EQV strain in periimplant bone were interpreted by means of a general linear model (ANOVA). Results: The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P<0.001). Mean IT-FBIC was 1.17±0.44 mm for EH, and 0.17±0.54 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P=0.005) was found for EH (mean 3438.65 µ∑) compared to MT (mean 840.98 µ∑) connection. Conclusions: Varying implant-abutment connection type will result in diverse periimplant bone remodeling, regardless of clinical and microbiological conditions. This fact is more likely attributed to the singular loading transmission through different implant-abutment connections to the periimplant bone. The present findings suggest that Morse-taper connection is more efficient to prevent periimplant bone loss, compared to an external hexagon connection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho divide-se em duas partes distintas: uma longa e detalhada revisão bibliográfica acerca das temáticas anatomia peri-implantar, espaço biológico, osso alveolar, osteointegração, cone Morse e platform-switching e FEA (Finit Element Analisys) ; e um estudo sobre tensões peri-implantares em implantes do tipo cone Morse colocados infra e justa crestalmente. Foi possível concluir com este estudo laboratorial que os implantes colocados justacrestalmente apresentam melhores resultados biomecanicamente, ou seja, apresentam um menor volume de osso em tensão. Materiais e métodos: Foi realizada uma pesquisa bibliográfica na PubMed e Medline explorando os seguintes items: “osteointegração”, “saucerização”, “platform switching”, “cone Morse”, “osso alveolar”, “anatomina peri-implantar”, “espaço biológico”, “osteoclastos”, “osteoblastos”, “remodelação óssea”, “colocação de implantes justacrestalmente”, “colocação de implantes infra-crestalmente” e “análise de FEA”. Na bibliografia encontrada com as temáticas supra-citadas foi feita uma cuidadosa selecção de acordo com aquilo a que este trabalho se propunha. Simultaneamente, um modelo 3D de dois implantes, um de conexão externa hexagonal e outro de conexão interna do tipo cone Morse, exactamente iguais com exceção da já referida conexão, de 10mm de comprimento e 4mm de diâmetro, foram inseridos num bloco ósseo obtido através de uma CT e sujeitos a uma força axial de 150N e uma força oblíqua de 150N a 45º, tendo sido avaliados por uma análise de elementos finitos.