984 resultados para Superior mesenteric artery flow


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the efficacy of superselective embolization therapy in the management of acute lower gastrointestinal (LGI) hemorrhage, including any bleeding distal to the ligament of Treitz. MATERIALS AND METHODS: Between June and August 2007, 20 patients with acute LGI bleeding underwent superselective transcatheter arterial embolization (TAE) at the authors' institution. The bleeding had different causes. All patients were treated with use of microcatheters. The following embolic agents were used: microcoils (n = 16), polyvinyl alcohol (PVA) particles (n = 2), and a combination of microcoils and PVA particles (n = 2). Outcome measures included technical success (complete cessation of bleeding as documented at completion angiography), clinical success (resolution of signs or symptoms of LGI bleeding within 30 days after TAE), and the rate of major and minor complications. RESULTS: The identified bleeding sources were as follows: jejunal branch, branch of middle colic artery, branch of ileocolic artery, ileal branch, branch of left colic artery, branch of sigmoid artery, branch of the superior rectal artery, and branch of the middle rectal artery. Technical success with effective control of active bleeding was achieved in all patients (100%). Clinical success attributed to TAE was documented in 18 of the 20 patients (90%). Major complications included death due to pulmonary embolism, heart infarction, and multiorgan failure in the 3rd week after TAE; a procedure-related colonic infarction occurred in one patient. A minor complication occurred in one patient who developed a groin hematoma. CONCLUSIONS: Superselective embolization may be used for effective, minimally invasive control of acute LGI bleeding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assisted reproductive technologies (ART) induce vascular dysfunction in humans and mice. In mice, ART-induced vascular dysfunction is related to epigenetic alteration of the endothelial nitric oxide synthase (eNOS) gene, resulting in decreased vascular eNOS expression and nitrite/nitrate synthesis. Melatonin is involved in epigenetic regulation, and its administration to sterile women improves the success rate of ART. We hypothesized that addition of melatonin to culture media may prevent ART-induced epigenetic and cardiovascular alterations in mice. We, therefore, assessed mesenteric-artery responses to acetylcholine and arterial blood pressure, together with DNA methylation of the eNOS gene promoter in vascular tissue and nitric oxide plasma concentration in 12-wk-old ART mice generated with and without addition of melatonin to culture media and in control mice. As expected, acetylcholine-induced mesenteric-artery dilation was impaired (P = 0.008 vs. control) and mean arterial blood pressure increased (109.5 ± 3.8 vs. 104.0 ± 4.7 mmHg, P = 0.002, ART vs. control) in ART compared with control mice. These alterations were associated with altered DNA methylation of the eNOS gene promoter (P < 0.001 vs. control) and decreased plasma nitric oxide concentration (10.1 ± 11.1 vs. 29.5 ± 8.0 μM) (P < 0.001 ART vs. control). Addition of melatonin (10(-6) M) to culture media prevented eNOS dysmethylation (P = 0.005, vs. ART + vehicle), normalized nitric oxide plasma concentration (23.1 ± 14.6 μM, P = 0.002 vs. ART + vehicle) and mesentery-artery responsiveness to acetylcholine (P < 0.008 vs. ART + vehicle), and prevented arterial hypertension (104.6 ± 3.4 mmHg, P < 0.003 vs. ART + vehicle). These findings provide proof of principle that modification of culture media prevents ART-induced vascular dysfunction. We speculate that this approach will also allow preventing ART-induced premature atherosclerosis in humans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED Obstructive sleep apnea (OSA) is a frequent syndrome characterized by intermittent hypoxemia and increased prevalence of arterial hypertension and cardiovascular morbidity. In OSA, the presence of patent foramen ovale (PFO) is associated with increased number of apneas and more severe oxygen desaturation. We hypothesized that PFO closure improves sleep-disordered breathing and, in turn, has favorable effects on vascular function and arterial blood pressure. In 40 consecutive patients with newly diagnosed OSA, we searched for PFO. After initial cardiovascular assessment, the 14 patients with PFO underwent initial device closure and the 26 without PFO served as control group. Conventional treatment for OSA was postponed for 3 months in both groups, and polysomnographic and cardiovascular examinations were repeated at the end of the follow-up period. PFO closure significantly improved the apnea-hypopnea index (ΔAHI -7.9±10.4 versus +4.7±13.1 events/h, P=0.0009, PFO closure versus control), the oxygen desaturation index (ΔODI -7.6±16.6 versus +7.6±17.0 events/h, P=0.01), and the number of patients with severe OSA decreased significantly after PFO closure (79% versus 21%, P=0.007). The following cardiovascular parameters improved significantly in the PFO closure group, although remained unchanged in controls: brachial artery flow-mediated vasodilation, carotid artery stiffness, nocturnal systolic and diastolic blood pressure (-7 mm Hg, P=0.009 and -3 mm Hg, P=0.04, respectively), blood pressure dipping, and left ventricular diastolic function. In conclusion, PFO closure in OSA patients improves sleep-disordered breathing and nocturnal oxygenation. This translates into an improvement of endothelial function and vascular stiffening, a decrease of nighttime blood pressure, restoration of the dipping pattern, and improvement of left ventricular diastolic function. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01780207.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND We aimed to identify a group of patients with a low risk of seizure after surgery for unruptured intracranial aneurysms (UIA). OBJECTIVE To determine the risk of seizure after discharge from surgery for UIA. METHODS A consecutive prospectively collected cohort database was interrogated for all surgical UIA cases. There were 726 cases of UIA (excluding cases proximal to the superior cerebellar artery on the vertebrobasilar system) identified and analyzed. Cox proportional hazards regression models and Kaplan-Meier life table analyses were generated assessing risk factors. RESULTS Preoperative seizure history and complication of aneurysm repair were the only risk factors found to be significant. The risk of first seizure after discharge from hospital following surgery for patients with neither preoperative seizure, treated middle cerebral artery aneurysm, nor postoperative complications (leading to a modified Rankin Scale score >1) was <0.1% and 1.1% at 12 months and 7 years, respectively. The risk for those with preoperative seizures was 17.3% and 66% at 12 months and 7 years, respectively. The risk for seizures with either complications (leading to a modified Rankin Scale score >1) from surgery or treated middle cerebral artery aneurysm was 1.4% and 6.8% at 12 months and 7 years, respectively. These differences in the 3 Kaplan-Meier curves were significant (log-rank P < .001). CONCLUSION The risk of seizures after discharge from hospital following surgery for UIA is very low when there is no preexisting history of seizures. If this result can be supported by other series, guidelines that restrict returning to driving because of the risk of postoperative seizures should be reconsidered. ABBREVIATIONS MCA, middle cerebral arterymRS, modified Rankin ScaleUIA, unruptured intracranial aneurysms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In endothelial cells, stretch-activated cation channels have been proposed to act as mechanosensors for changes in hemodynamic forces. We have identified a novel mechanosensitive pressure-activated channel in intact endothelium from rat aorta and mesenteric artery. The 18-pS cation channel responded with a multifold increase in channel activity when positive pressure was applied to the luminal cell surface with the patch pipette and inactivated at negative pipette pressure. Channel permeability ratio for K+, Na+, and Ca2+ ions was 1:0.98:0.23. Ca2+ influx through the channel was sufficient to activate a neighboring Ca2(+)-dependent K+ channel. Hemodynamic forces are chronically disturbed in arterial hypertension. Endothelial cell dysfunction has been implicated in the pathogenesis of arterial hypertension. In two comparative studies, density of the pressure-activated channel was found to be significantly higher in spontaneously hypertensive rats and renovascular hypertensive rats compared with their respective normotensive controls. Channel activity presumably leads to mechanosensitive Ca2+ influx and induces cell hyperpolarization by K+ channel activity. Both Ca2+ influx and hyperpolarization are known to induce a vasodilatory endothelial response by stimulating endothelial nitric oxide (NO) production. Up-regulation of channel density in hypertension could, therefore, represent a counterregulatory mechanism of vascular endothelium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The renin-angiotensin system plays a crucial role in the development and establishment of the hypertensive state in the spontaneously hypertensive (SH) rat. Interruption of this system's activity by pharmacological means results in the lowering of blood pressure (BP) and control of hypertension. However, such means are temporary and require the continuous use of drugs for the control of this pathophysiological state. Our objective in this investigation was to determine if a virally mediated gene-transfer approach using angiotensin type 1 receptor antisense (AT1R-AS) could be used to control hypertension on a long-term basis in the SH rat model of human essential hypertension. Injection of viral particles containing AT1R-AS (LNSV-AT1R-AS) in 5-day-old rats resulted in a lowering of BP exclusively in the SH rat and not in the Wistar Kyoto normotensive control. A maximal anti-hypertensive response of 33 +/- 5 mmHg was observed, was maintained throughout development, and still persisted 3 months after administration of LNSV-AT1R-AS. The lowering of BP was associated with the expression of AT1R-AS transcript and decreases in AT1-receptor in many peripheral angiotensin II target tissues such as mesenteric artery, adrenal gland, heart, and kidney. Attenuation of angiotensin II-stimulated physiological actions such as contraction of aortic rings and increase in BP was also observed in the LNSV-AT1R-AS-treated SH rat. These observations show that a single injection of LNSV-AT1R-AS normalizes BP in the SH rat on a long-term basis. They suggest that such a gene-transfer strategy can be successfully used to control the development of hypertension on a permanent basis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to identify guanine nucleotide-binding proteins (G proteins) involved in the agonist- and guanosine 5'-[gamma-thio]triphosphate (GTP[gamma-S])-induced increase in the Ca2+ sensitivity of 20-kDa myosin light chain (MLC20) phosphorylation and contraction in smooth muscle. A constitutively active, recombinant val14p21rhoA.GTP expressed in the baculovirus/Sf9 system, but not the protein expressed without posttranslational modification in Escherichia coli, induced at constant Ca2+ (pCa 6.4) a slow contraction associated with increased MLC20 phosphorylation from 19.8% to 29.5% (P < 0.05) in smooth muscle permeabilized with beta-esein. The effect of val14p21rhoA.GTP was inhibited by ADP-ribosylation of the protein and was absent in smooth muscle extensively permeabilized with Triton X-100. ADP-ribosylation of endogenous p21rho with epidermal cell differentiation inhibitor (EDIN) inhibited Ca2+ sensitization induced by GTP [in rabbit mesenteric artery (RMA) and rabbit ileum smooth muscles], by carbachol (in rabbit ileum), and by endothelin (in RMA), but not by phenylephrine (in RMA), and only slowed the rate without reducing the amplitude of contractions induced in RMA by 1 microM GTP[gamma-S] at constant Ca2+ concentrations. AlF(4-)-induced Ca2+ sensitization was inhibited by both guanosine 5'-[beta-thio]diphosphate (GDP[beta-S]) and by EDIN. EDIN also inhibited, to a lesser extent, contractions induced by Ca2+ alone (pCa 6.4) in both RMA and rabbit ileum. ADP-ribosylation of trimeric G proteins with pertussis toxin did not inhibit Ca2+ sensitization. We conclude that p21rho may play a role in physiological Ca2+ sensitization as a cofactor with other messengers, rather than as a sole direct inhibitor of smooth muscle MLC20 phosphatase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indirect immunofluorescence methods using a mouse monoclonal antibody raised to rat choline acetyltransferase (ChAT) revealed dense networks of ChAT-immunoreactive fibers in the superior cervical ganglion, the stellate ganglion, and the celiac superior mesenteric ganglion of the rat. Numerous and single ChAT-immunoreactive cell bodies were observed in the stellate and superior cervical ganglia, respectively. The majority of ChAT-immunoreactive fibers in the stellate and superior cervical ganglia were nitric oxide synthase (NOS) positive. Some ChAT-immunoreactive fibers contained enkephalin-like immunoreactivity. Virtually all ChAT-positive cell bodies in the stellate ganglion were vasoactive intestinal polypeptide (VIP)-positive, and some were calcitonin gene-related peptide (CGRP)-positive. After transection of the cervical sympathetic trunk almost all ChAT- and NOS-positive fibers and most enkephalin- and CGRP-positive fibers disappeared in the superior cervical ganglion. The results suggest that most preganglionic fibers are cholinergic and that the majority of these in addition can release nitric oxide, some enkephalin, and a few CGRP. Acetylcholine, VIP, and CGRP are coexisting messenger molecules in some postganglionic sympathetic neurons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The devastating impact of Type 2 Diabetes Mellitus (T2DM) -related morbidity and mortality on global healthcare is escalating with higher prevalences of obesity, poor diet, and sedentary lifestyles. Therefore, the clinical need for early diagnosis and prevention in groups of high-risk individuals is necessary. The purpose of this thesis was to investigate the use of surrogate markers, namely retinal vascular function, to determine future vascular endothelial dysfunction, atherosclerosis, large vessel disease and cardiovascular risk in certain groups. This namely covered normoglycaemic and normotensive South Asians (SAs), those with Impaired-Glucose Tolerance (IGT) and individuals with a familial history (FH) of T2DM. Additionally the effect of overweight and obesity was studied. The techniques and modified protocols adopted for this thesis involved the investigation of endothelial function by means of vascular reactivity at the ocular and systemic level. Furthermore, the relationships between retinal and systemic function with circulating markers for endothelial cell function and cardiovascular risk markers were explored. The principal studies and findings of the research were: Vascular Function in Normoglycaemic Individuals with and without a FH of T2DM WE FH individuals exhibited higher levels of total cholesterol levels that correlated well with the retinal arterial dilation amplitude to flicker light stimulus. However this did not extend to noticeable differences in markers for endothelial cell damage and impaired retinal and systemic function. Vascular Function in Normoglycaemic South-Asians vs. White-Europeans without a FH and Vascular Disturbances Compared to healthy WEs (normo -glycaemic and -tensive), SA participants exhibited levels of dyslipidaemia and a state of oxidative stress that extended to impaired vascular function as detected by reduced brachial artery flow-mediated dilation, slower retinal arterial vessel dilation reaction times (Appendix 3) and steeper constriction profiles. Furthermore, gender sub-group analysis presented in a sub-chapter shows that SA males demonstrated 24-hour systemic blood pressure (BP) and heart rate variability (HRV) abnormalities and heightened cardiovascular disease (CVD) risk. Vascular Function in Individuals Newly Diagnosed with IGT as compared to Normoglycaemic Healthy Controls Newly-diagnosed WE and SA IGT patients showed a greater risk for CVD and T2DM progression by means of 24-hour BP abnormalities, dyslipidaemia, increased carotid artery intimal-media thickness (c-IMT), Framingham scores and cholesterol ratios. Additionally, pre-clinical markers for oxidative stress and endothelial dysfunction, as evident by significantly lower levels of plasma glutathione and increased levels of von-Willebrand factor in IGT individuals, extended to impaired vascular systemic and retinal function compared to normal controls. This originally shows retinal, systemic and biochemical disturbances in newly-diagnosed IGT not previously reported before. Vascular Function in Normal, Overweight and Obese Individuals of SA and WE Ethnicity In addition to the intended study chapters, the thesis also investigated the influence of obesity and overweight on vascular function. Most importantly, it was found for the first time that compared to lean individuals it was overweight and not obese individuals that exhibited signs of vascular systemic and ocular dysfunction that was evident alongside markers of atherosclerosis, CVD risk and endothelial damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contractile response of rat aorta, mesenteric artery and femoral artery to noradrenaline and potassium chloride were studied under standard and hypoxic conditions and the effect of hypoxia was dependent upon both the vessel and the stimulant. Hypoxia had less effect upon contractions to potassium chloride than those to noradrenaline. The effects of hypoxia on potassium chloride induced responses in different vessels were relatively similar although responses to noradrenaline were vessel dependent. Noradrenaline induced contractions of the femoral artery were most affected by hypoxia whilst those of the mesenteric artery were least affected. Hypoxia changed the well maintained response of the femoral artery to noradrenaline to a transient form; this effect of hypoxia was not evident in the aorta or the mesenteric artery. The aorta and mesenteric artery contracted in calcium free EGTA PSS suggesting that these vessels displayed a release component. Hypoxia reduced the magnitude of this component. The effects of verapamil on noradrenaline and potassium chloride induced responses were investigated and were found to be different to those of hypoxia. Verapamil exerted a greater effect on contractions to potassium chloride than on those to noradrenaline. The effects of hypoxia on 45calcium flux were also vessel dependent. In the mesenteric and femoral arteries hypoxia increased basal 45calcium accumulation. However, the magnitude of noradrenaline stimulated 45calcium accumulation was reduced in the femoral artery and aorta but was unchanged in the mesenteric artery. The effects of hypoxia on 45calcium accumulation were similar to verapamil only in the aorta. The results provide evidence that the effects of hypoxia may arise from alterations in calcium mobilisation processes and that differences between vessels in these processes accounts for the heterogeneity between vessels in their response to hypoxia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Background: One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. Methods: A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Results: Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). Conclusion: The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND: Recently, a compact cardiopulmonary support (CPS) system designed for quick set-up for example, during emergency cannulation, has been introduced. Traditional rectilinear percutaneous cannulas are standard for remote vascular access with the original design. The present study was designed to assess the potential of performance increase by the introduction of next-generation, self-expanding venous cannulas, which can take advantage of the luminal width of the venous vasculature despite a relatively small access orifice. METHODS: Veno-arterial bypass was established in three bovine experiments (69+/-10 kg). The Lifebridge (Lifebridge GmbH, Munich, Germany) system was connected to the right atrium in a trans-jugular fashion with various venous cannulas; and the oxygenated blood was returned through the carotid artery with a 17 F percutaneous cannula. Two different venous cannulas were studied, and the correlation between the centrifugal pump speed (1500-3900 RPM), flow and the required negative pressure on the venous side was established: (A) Biomedicus 19 F (Medtronic, Tolochenaz, Switzerland); (B) Smart canula 18 F/36 F (Smartcanula LLC, Lausanne, Switzerland). RESULTS: At 1500 RPM, the blood flow was 0.44+/-0.26 l min(-1) for the 19 F rectilinear cannula versus 0.73+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 2500 RPM the blood flow was 1.63+/-0.62 l min(-1) for the 19F rectilinear cannula versus 2.13+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 3500 RPM, the blood flow was 2.78+/-0.47 l min(-1) for the 19 F rectilinear cannula versus 3.64+/-0.39 l min(-1) for the 18/36 F self-expanding cannula (p<0.01 for 18/36 F vs 19 F). At 1500 RPM, the venous line pressure was 18+/-8 mmHg for the 19F rectilinear cannula versus 19+/-5 mmHg for the 18/36 F self-expanding cannula. At 2500 RPM the venous line pressure accounted for -22+/-32 mmHg for the 19 F rectilinear cannula versus 2+/-5 mmHg for the 18/36 F self-expanding cannula. At 3500 RPM, the venous line pressure was -112+/-42 mmHg for the rectilinear cannula versus 28+/-7 mmHg for the 18/36 F self-expanding cannula (p<0.01 for 18 F/36 F vs 19 F). Conclusions: The negative pressure required to achieve adequate venous drainage with the self-expanding venous cannula accounts for approximately 31% of the pressure necessary with the 19 F rectilinear cannula. In addition, a pump flow of more than 4 l min(-1) can be achieved with the self-expanding design and a well-accepted negative inlet pressure for minimal blood trauma of less than 50 mmHg.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Endovascular treatment is an increasingly used therapeutic option in patients with chronic atherosclerotic occlusive mesenteric disease. Purpose of this study was evaluation of patency and mortality in patients treated with visceral artery percutaneous transluminal angioplasty (PTA) or stenting including follow-up.