941 resultados para Spatially Offset Raman Spectrometer
Resumo:
There exist several researches and applications about laser welding monitoring and parameter control but not a single one have been created for controlling of laser scribing processes. Laser scribing is considered to be very fast and accurate process and thus it would be necessary to develop accurate turning and monitoring system for such a process. This research focuses on finding out whether it would be possible to develop real-time adaptive control for ultra-fast laser scribing processes utilizing spectrometer online monitoring. The thesis accurately presents how control code for laser parameter tuning is developed using National Instrument's LabVIEW and how spectrometer is being utilized in online monitoring. Results are based on behavior of the control code and accuracy of the spectrometer monitoring when scribing different steel materials. Finally control code success is being evaluated and possible development ideas for future are presented.
Resumo:
The purpose of this study was to identify the impact of stressors and offsetting satistiers, measured in this study with Stress Offset Score (SOS), on intentions to quit and examine the mediating and moderating effects of three facets of work satisfaction (job satisfaction, pay satisfaction, and satisfaction with supervisor) and two facets of organizational commitment (affective and nonnative commitment) on this relationship. The sample was composed of 2990 employees from 21 public and private organizations. The interaction of each type of work satisfaction and organizational commitment, with SOS, was tested using Ordinary Least Squares (OLS) procedures. Intentions to quit was the dependent variable. The research questions were determine: (1) Does SOS predict intentions to quit? (2) Does work satisfaction mediate the predictive relationship of SOS on intentions to quit? (3) Does organizational commitment mediate the predictive relationship of SOS on intent to quit? (4) Does work satisfaction moderate the predictive relationship of SOS on intentions to quit? and (5) Does organizational commitment moderate the predictive relationship of SOS on intentions to quit? The results indicated that SOS was negatively correlated with intentions to quit. Each of the types of work satisfaction and organizational commitment variables showed a partial mediated relationship with SOS and each relationship was highly significant, while normative commitment explained more of the relationship then other mediators. The study also tested for interactions but no statistical significant relationships where established between any of the interaction terms (e.g., SOSxJob Satisfaction and SOSxAffcctive Commitment) and intentions to quit.
Resumo:
Using the Physical Vapor Transport method, single crystals of Cd2Re207 have been grown, and crystals of dimensions up to 8x6x2 mm have been achieved. X-ray diffraction from a single crystal of Cd2Re207 has showed the crystal growth in the (111) plane. Powder X-ray diffraction measurements were performed on ^^O and ^^O samples, however no difference was observed. Assigning the space group Fd3m to Cd2Re207 at room temperature and using structure factor analysis, the powder X-ray diffraction pattern of the sample was explained through systematic reflection absences. The temperatiure dependence of the resistivity measurement of ^^O has revealed two structural phase transitions at 120 and 200 K, and the superconducting transition at 1.0 K. Using Factor Group Analysis on three different structiures of Cd2Re207, the number of IR and Raman active phonon modes close to the Brillouin zone centre have been determined and the results have been compared to the temperature-dependence of the Raman shifts of ^^O and ^*0 samples. After scaling (via removing Bose-Einstein and Rayleigh scattering factors from the scattered light) all spectra, each spectrum was fitted with a number of Lorentzian peaks. The temperature-dependence of the FWHM and Raman shift of mode Eg, shows the effects of the two structurjil phase transitions above Tc. The absolute reflectance of Cd2Re207 - '^O single crystals in the far-infrared spectral region (7-700 cm~^) has been measured in the superconducting state (0.5 K), right above the superconducting state (1.5 K), and in the normal state (4.2 K). Thermal reflectance of the sample at 0.5 K and 1.5 K indicates a strong absorption feature close to 10 cm~^ in the superconducting state with a reference temperature of 4.2 K. By means of Kramers-Kronig analysis, the absolute reflectance was used to calculate the optical conductivity and dielectric function. The real part of optical conductivity shows five distinct active phonon modes at 44, 200, 300, 375, and 575 cm~' at all temperatures including a Drude-like behavior at low frequencies. The imaginary part of the calculated dielectric function indicates a mode softening of the mode 44 cm~' below Tc.
Resumo:
Modifications to the commercial hydride generator, manufactured by Spectrametrics, resulted in improved operating procedure and enhancement of the arsenic and germanium signals. Experiments with arsenic(III) and arsenic(V) showed that identical reiults could be produced from both oxidation states. However, since arsenic(V) is reduced more slowly than arsenic(III), peak areas and not peak heights must be measured when the arsine is immediately stripped from the system (approximately 5 seconds reaction). When the reduction is allowed to proceed for 20 seconds before the arsine is stripped, peak heights may be used. For a 200 ng/mL solution, the relative standard deviation is 2.8% for As(III) and 3.8% for As(V). The detection limit for arsenic using the modified system is 0.50 ng/mL. Studies performed on As(V) standards show that the interferences from 1000 mg/L of nickel(II), cobalt(II), iron(III), copper(II), cadmium(II), and zinc(II) can be eliminated with the aid of 5 M Hel and 3% L-cystine. Conditions for the reduction of germanium to the corresponding hydride were investigated. The effect of different concentrations of HCl on the reduction of germanium to the covalent hydride in aqueous media by means of NaBH 4 solutions was assessed. Results show that the best response is accomplished at a pH of 1.7. The use of buffer solutions was similarly characterized. In both cases, results showed that the element is best reduced when the final pH of the solution after reaction is almost neutral. In addition, a more sensitive method, which includes the use of (NH4)2S208' has been developed. A 20% increase in the germanium signal is registered when compared to the signal achieved with Hel alone. Moreover, under these conditions, reduction of germanium could be accomplished, even when the solution's pH is neutral. For a 100 ng/mL germanium standard the rsd is 3%. The detection limit for germanium in 0.05 M Hel medium (pH 1.7) is 0.10 ng/mL and 0.09 ng/mL when ammonium persulphate is used in conjunction with Hel. Interferences from 1000 mg/L of iron(III), copper(II), cobalt(II), nickel(II), cadmium(II), lead(II), mercury(II), aluminum(III), tin(IV), arsenic(III), arsenic(V) and zinc(II) were studied and characterized. In this regard, the use of (NH4)ZS20S and Hel at a pH of 1.7 proved to be a successful mixture in the sbppression of the interferences caused by iron, copper, aluminum, tin, lead, and arsenic. The method was applied to the determination of germanium in cherts and iron ores. In addition, experiments with tin(IV) showed that a 15% increase in the tin signal can be accomplished in the presence of 1 mL of (NH4)2S20S 10% (m/V).
Resumo:
Improvements have been made on the currently available hydride generator system manufactured by SpectraMetrics Incorporated, because the system was found to be unsatisfactory with respect to the following: 1. the drying agent, anhydrous calcium chloride, 2. the special sample tube, 3. the direction of argon flow through the Buchner funnel when it came to dealing with real sample, that is, with reference only to aqueous extracts of soil samples. Changes that were made on the system included the replacement of anhydrous calcium chloride with anhydrous calcium sulphate and the replacement of the special sample tube with a modified one made from silica. Re-directing the flow of argon through the top of the Buchner funnel appeared to make the system compatible with aqueous extracts of soil samples. The interferences from 1000 ~g/mL of nickel(II) , cobalt(II), iron(III), copper(II) have been eliminated with the aid of 1.4 M hydrochloric acid and 1% (weight/volume) L-cystine. Greater than 90% recovery of 0.3 ~g/mL arsenic signal was achieved in each case. Furthermore, 103% of arsenic signal was accomplished in the presence of 1000 ~g/mL cadmium with 5 M Hel. tVhen each of the interferents was present in solution at 1000 ppm, a recovery of 85% was achieved by using 5 M hydrochloric acid and 3% (weight/volume) L-cystine. Without L-cystine and when 1.4 M hydrochloric acid was used, the recoveries were 0% (Ni), 0% (Co), 88% (Fe), 15% (Cu), 18% (Cd). Similarly, a solution containing 1000 ppm of each interferent gave a zero percent recovery of arsenic. The reduction of trivalent and pentavalent arsenic at a pH less than one has also been investigated and shown to be quantitative if peak areas are measured. The reproducibility determination of a 0.3 Vg/mL standard arsenic solution by hydride generation shows a relative standard deviation of 3.4%. The detection limits with and without Porapak Q have been found to be 0.6 ng/mL and 1.0 ng/mL, respectively.
Resumo:
Raman scattering in the region 20 to 100 cm -1 for fused quartz, "pyrex" boro-silicate glass, and soft soda-lime silicate glass was investigated. The Raman spectra for the fused quartz and the pyrex glass were obtained at room temperature using the 488 nm exciting line of a Coherent Radiation argon-ion laser at powers up to 550 mW. For the soft soda-lime glass the 514.5 nm exciting line at powers up to 660 mW was used because of a weak fluorescence which masked the Stokes Raman spectrum. In addition it is demonstrated that the low-frequency Raman coupling constant can be described by a model proposed by Martin and Brenig (MB). By fitting the predicted spectra based on the model with a Gaussian, Poisson, and Lorentzian forms of the correlation function, the structural correlation radius (SCR) was determined for each glass. It was found that to achieve the best possible fit· from each of the three correlation functions a value of the SCR between 0.80 and 0.90 nm was required for both quartz and pyrex glass but for the soft soda-lime silicate glass the required value of the SCR. was between 0.50 and 0.60 nm .. Our results support the claim of Malinovsky and Sokolov (1986) that the MB model based on a Poisson correlation function provides a universal fit to the experimental VH (vertical and horizontal polarizations) spectrum for any glass regardless of its chemical composition. The only deficiency of the MB model is its failure to fit the experimental depolarization spectra.
Resumo:
A new Ultra-High Vacuum (UHV) reflectance spectrometer was successfully designed, making use of a Janis Industries ST-400 sample cryostat, IR Labs bolometer, and Briiker IFS 66 v/S spectrometer. Two of the noteworthy features include an in situ gold evaporator and internal reference path, both of which allow for the experiment to progress with a completely undisturbed sample position. As tested, the system was designed to operate between 4.2 K and 325 K over a frequency range of 60 - 670 cm~^. This frequency range can easily be extended through the addition of appUcable detectors. Tests were performed on SrTiOa, a highly ionic incipient ferroelectric insulator with a well known reflectance. The presence and temperatmre dependence of the lowest frequency "soft" mode were measured, as was the presence of the other two infrared modes. During the structural phase transition from cubic to tetragonal perovskite, the splitting of the second phonon mode was also observed. All of the collected data indicate good agreement with previous measurements, with a minor discrepency between the actual and recorded sample temperatures.
Resumo:
Les transitions de spin provoquent des changements de propriétés physiques des complexes de métaux du bloc d les subissant, notamment de leur structure et propriétés spectroscopiques. Ce mémoire porte sur la spectroscopie Raman de composés du fer(II) et du fer(III), pour lesquels on induit une transition de spin par variation de la température ou de la pression. Trois complexes de fer(II) de type FeN4(NCS)2 avec des comportements de transition de spin différents ont été étudiés : Fe(Phen)2(NCS)2 (Phen : 1,10-Phénanthroline), Fe(Btz)2(NCS)2 (Btz : 2,2’-bi-4,5-dihydrothiazine) et Fe(pyridine)4(NCS)2. Un décalage de l’ordre de 50 cm-1 est observable pour la fréquence d’étirement C-N du ligand thiocyanate des complexes FeN4(NCS)2, lors de la transition de spin induite par variation de la température ou de la pression. Il est possible d’utiliser cette variation de fréquence afin de tracer un profil de transition. Quatre complexes isomères de type FeL222(CN)2 (L222 : 2,13- diméthyl-6,9-dioxa-3,12,18-triazabicyclo[12.3.1]-octadéca-1(18),2,12,14,16-pentaène) ont également été étudiés. Un taux de décalage de l’ordre d’environ 0,03 cm-1/K est observé pour plusieurs bandes du complexe FeL222(CN)2. La bande à 1415 cm-1 disparaît à plus haute température au profit d’une bande à 1400 cm-1. Pour le complexe de chiralité R,R’, les bandes à 1008 cm-1 et 1140 cm-1 se déplacent vers des fréquences plus élevées à partir de 223 K. Les transitions de spin sont observées dans certains complexes de fer(III). Dans cette famille de composés, le complexe Fe(EtDTC)3 (EtDTC : N,N-diéthyldithiocarbamate) a été étudié . Aucun changement n’a été observé dans l’intensité des bandes d’étirement fer-soufre sur les spectres à température variable. Cependant, la bande Fe-S associée à la forme bas-spin à 530 cm-1 augmente en intensité au profit de la bande associée à la forme haut-spin à 350 cm-1 lors des mesures à haute pression, passant d’un rapport d’amplitude de 50% à pression ambiante à 80% à 21 kbar. Un dédoublement de la bande d’étirement C-N du ligand dithiocarbamate à 1495 cm-1 est également observé à des pressions supérieures à 5 kbar. Une comparaison des changements des fréquences de vibration de tous les complexes est effectuée.
Resumo:
La concentration locale des messagers chimiques sécrétés par les cellules peut être mesurée afin de mieux comprendre les mécanismes moléculaires liés à diverses maladies, dont les métastases du cancer. De nouvelles techniques analytiques sont requises pour effectuer ces mesures locales de marqueurs biologiques à proximité des cellules. Ce mémoire présentera le développement d’une nouvelle technique basée sur la réponse plasmonique sur des leviers AFM, permettant d’étudier les réactions chimiques et biologiques à la surface des leviers grâce au phénomène de résonance des plasmons de surface (SPR), ainsi qu’à la diffusion Raman exaltée par effet de pointe (TERS). En effet, il est possible de localiser l’amplification du signal Raman à la pointe d’un levier AFM, tout comme le principe de la diffusion Raman exaltée par effet de surface (SERS) basée sur la diffusion de la lumière par des nanoparticules métalliques, et permettant une large amplification du signal Raman. La surface du levier est recouverte d’une nano-couche métallique d’or, suivi par des réactions biologiques pour l’immobilisation d’un récepteur moléculaire, créant ainsi un biocapteur sur la pointe du levier. Une détection secondaire utilisant des nanoparticules d’or conjuguées à un anticorps secondaire permet également une amplification du signal SPR et Raman lors de la détection d’antigène. Ce mémoire démontrera le développement et la validation de la détection de l’immunoglobuline G (IgG) sur la pointe du levier AFM.Dans des projets futurs, cette nouvelle technique d’instrumentation et d’imagerie sera optimisée grâce à la création d’un micro-détecteur protéique généralement adapté pour l’étude de la communication cellulaire. En intégrant le signal SPR à la microscopie AFM, il sera alors possible de développer des biocapteurs SPR couplés à une sonde à balayage, ce qui permettra d’effectuer une analyse topographique et de l’environnement chimique d’échantillons cellulaires en temps réel, pour la mesure des messagers moléculaires sécrétés dans la matrice extracellulaire, lors de la communication cellulaire.
Resumo:
Targeted peptide methods generally use HPLC-MS/MRM approaches. Although dependent on the instrumental resolution, interferences may occur while performing analysis of complex biological matrices. HPLC-MS/MRM3 is a technique, which provides a significantly better selectivity, compared with HPLC-MS/MRM assay. HPLC-MS/MRM3 allows the detection and quantitation by enriching standard MRM with secondary product ions that are generated within the linear ion trap. Substance P (SP) and neurokinin A (NKA) are tachykinin peptides playing a central role in pain transmission. The objective of this study was to verify whether HPLC-HPLCMS/ MRM3 could provide significant advantages over a more traditional HPLC-MS/MRM assay for the quantification of SP and NKA in rat spinal cord. The results suggest that reconstructed MRM3 chromatograms display significant improvements with the nearly complete elimination of interfering peaks but the sensitivity (i.e. signal-to-noise ratio) was severely reduced. The precision (%CV) observed was between 3.5% - 24.1% using HPLC-MS/MRM and in the range of 4.3% - 13.1% with HPLC-MS/MRM3, for SP and NKA. The observed accuracy was within 10% of the theoretical concentrations tested. HPLC-MS/MRM3 may improve the assay sensitivity to detect difference between samples by reducing significantly the potential of interferences and therefore reduce instrumental errors.
Resumo:
The present work is mainly concentrated on setting up a NIR tunable diode laser absorption (TDLA) spectrometer for high-resolution molecular spectroscopic studies. For successfully recording the high-resolution tunable diode laser spectrum, various experimental considerations are to be taken into account like the setup should be free from mechanical vibrations, sample should be kept at a low pressure, laser should be in a single mode operation etc. The present experimental set up considers all these factors. It is to be mentioned here that the setting up of a high resolution NIR TDLA spectrometer is a novel experiment requiring much effort and patience. The analysis of near infrared (NIR) vibrational overtone spectra of some substituted benzene compounds using local mode model forms another part of the present work. An attempt is made to record the pulsed laser induced fluorescence/Raman spectra of some organic compounds. A Q-switched Nd:YAG laser is used as the excitation source. A TRIAX monochromator and CCD detector is used for the spectral recording. The observed fluorescence emission for carbon disulphide is centered at 680 nm; this is assigned as due to the n, p* transition. Aniline also shows a broad fluorescence emission centered at 725 nm, which is due to the p,p* transition. The pulsed laser Raman spectra of some organic compounds are also recorded using the same experimental setup. The calibration of the set up is done using the laser Raman spectra of carbon tetrachloride and carbon disulphide. The observed laser Raman spectra for aniline, o-chloroaniline and m-chlorotoluene show peaks characteristics of the aromatic ring in common and the characteristics peaks due to the substitutuent groups. Some new peaks corresponding to low-lying vibrations of these molecules are also assigned
Resumo:
A technique for improving the coupling between a feed horn and reflector by using corrugated metallic flanges is presented. Experimental data for flanges of varying parameters are given and theoretical explanation is supplemented
Resumo:
Polymethyl methacrylate (PMMA) optical fibres are fabricated by a preform drawing process. The Raman spectra of PMMA fibres are recorded using a diode pumped solid state laser emitting at 532 nm and a CCD-spectrograph in the 400–3800 cm−1 range. The variation of the Raman intensity with the length of the optical fibre is studied. Investigations are carried out on the variation of FWHM of the Raman peak at 2957 cm−1 with the length of the optical fibre and pump power. The differential scattering cross section and gain coefficient of the Raman peak at 2957 cm−1 in PMMA are calculated in relation to that of toluene.
Resumo:
Polymethyl methacrylate (PMMA) optical fibres are fabricated by a preform drawing process. The Raman spectra of PMMA fibres are recorded using a diode pumped solid state laser emitting at 532 nm and a CCD-spectrograph in the 400–3800 cm−1 range. The variation of the Raman intensity with the length of the optical fibre is studied. Investigations are carried out on the variation of FWHM of the Raman peak at 2957 cm−1 with the length of the optical fibre and pump power. The differential scattering cross section and gain coefficient of the Raman peak at 2957 cm−1 in PMMA are calculated in relation to that of toluene