895 resultados para Solar Array, Shade, Power Output
Resumo:
The aim of this thesis is to describe hybrid drive design problems, the advantages and difficulties related to the drive. A review of possible hybrid constructions, benefits of parallel, series and series-parallel hybrids is done. In the thesis analytical and finite element calculations of permanent magnet synchronous machines with embedded magnets were done. The finite element calculations were done using Cedrat’s Flux 2D software. This machine is planned to be used as a motor-generator in a low power parallel hybrid vehicle. The boundary conditions for the design were found from Lucas-TVS Ltd., India. Design Requirements, briefly: • The system DC voltage level is 120 V, which implies Uphase = 49 V (RMS) in a three phase system. • The power output of 10 kW at base speed 1500 rpm (Torque of 65 Nm) is desired. • The maximum outer diameter should not be more than 250 mm, and the maximum core length should not exceed 40 mm. The main difficulties which the author met were the dimensional restrictions. After having designed and analyzed several possible constructions they were compared and the final design selected. Dimensioned and detailed design is performed. Effects of different parameters, such as the number of poles, number of turns and magnetic geometry are discussed. The best modification offers considerable reduction of volume.
Resumo:
Tämä diplomityö on osa FCEP hankkeen Lappeenrannan teknillisessä yliopistossa tehtävää tutkimusta polttomoottoreiden energiatehokkuuden parantamisesta. Työn tavoitteena on saada tutkimustietoa polttomoottoreiden ahtoilman hukkalämmön hyödyntämisestä sähköntuotannossa Rankine-prosessilla. Tavoitteena on myös suorittaa ahtoilman hukkalämpöä hyödyntävän koelaitteiston prosessitekninen mitoitus. Työssä kartoitetaan sovelluskohteeseen sopivimmat kiertoaineet sekä suoritetaan prosessin lämmönsiirtimien ja putkiston lämpö- ja virtaustekninen päämitoitus. Työssä tarkasteltavaksi moottoriksi valittiin Wärtsilä 4R32 – moottori. Laskennat suoritettiin moottorin valmistajan antamien arvojen perusteella. Laskennan perusperiaatteena oli vertailla vesihöyryprosessia ja ORC-prosessia keskilämpötilaisen ahtoilman hyödyntämisessä. Työssä vertailtiin 12 eri kiertoaineen prosessihyötysuhdetta, saatavaa sähkötehoa sekä prosessin painetasoja. Kiertoainevertailun perusteella koelaitteeseen valittiin neljä kohteeseen parhaiten soveltuvinta kiertoainetta, joille mitoitettiin höyrystin, lauhdutin, rekuperaattori ja putkisto. Diplomityön laskennan perusteella tutkimuksen kohteena olleen moottorin sähköntuotannon lisäykseksi saatiin 1,77 %, kun ahtoilman hukkalämpö muunnetaan Rankine-prosessilla sähköksi. Työssä saatiin arvokasta tietoa polttomoottorin ahtoilman hukkalämmön sähköksi muuntamisesta sekä vesihöyryprosessilla, että ORC-prosessilla.
Resumo:
Tämä diplomityö on osa Lappeenrannan teknillisessä yliopistossa tehtävää tutkimusta polttomoottoreiden energiatehokkuuden parantamisessa. Työn tavoitteena on saada tutkimustietoa polttomoottoreiden hukkalämpövirtojen hyödyntämisestä sähköntuotannossa. Tavoitteena on muodostaa näkemys Mikro-ORC energiamuuntimen mahdollisuuksista ja reunaehdoista osana työkoneluokan (150 kW… 400 kW) dieselmoottorikokonaisuutta, erityisesti maataloussektorilla. Työssä tarkasteltaviksi moottoreiksi valittiin kaksi eri AGCO Sisu Powerin dieselmoottoria. Laskennat suoritettiin moottorin valmistajan antamien hukkalämpövirtojen arvojen perusteella. Laskennan perusperiaatteena oli tutkia ORC-prosessin tuottamaa lisäsähkötehoa hyödyntämällä pakokaasujen lämpöenergiaa korkea-, keski- ja matalalämpötiloissa. Työssä vertailtiin kahden eri kiertoaineen prosessihyötysuhdetta, saatava sähkötehoa sekä prosessin sisäisiä parametreja. Lisäksi työssä tutkittiin ORC-prosessin laskentaa suunnittelupisteessä (design) ja suunnittelupisteen ulkopuolella (off-design), prosessisuureiden optimointia ja lämmönsiirtimien mitoitusta. Diplomityössä tarkasteltiin moottorin energiataseen mukaisten arvojen lisäksi moottorin parametrien muuttamisen vaikutusta hukkalämpövirroista saatavan tehoon. Työssä saatiin arvokasta tietoa polttomoottoreiden hukkalämpövirtojen muuntamisesta sähköksi ORC:lla sekä moottorin energiatehokkuuden parantamisesta.
Resumo:
Physical exercise is associated with parasympathetic withdrawal and increased sympathetic activity resulting in heart rate increase. The rate of post-exercise cardiodeceleration is used as an index of cardiac vagal reactivation. Analysis of heart rate variability (HRV) and complexity can provide useful information about autonomic control of the cardiovascular system. The aim of the present study was to ascertain the association between heart rate decrease after exercise and HRV parameters. Heart rate was monitored in 17 healthy male subjects (mean age: 20 years) during the pre-exercise phase (25 min supine, 5 min standing), during exercise (8 min of the step test with an ascending frequency corresponding to 70% of individual maximal power output) and during the recovery phase (30 min supine). HRV analysis in the time and frequency domains and evaluation of a newly developed complexity measure - sample entropy - were performed on selected segments of heart rate time series. During recovery, heart rate decreased gradually but did not attain pre-exercise values within 30 min after exercise. On the other hand, HRV gradually increased, but did not regain rest values during the study period. Heart rate complexity was slightly reduced after exercise and attained rest values after 30-min recovery. The rate of cardiodeceleration did not correlate with pre-exercise HRV parameters, but positively correlated with HRV measures and sample entropy obtained from the early phases of recovery. In conclusion, the cardiodeceleration rate is independent of HRV measures during the rest period but it is related to early post-exercise recovery HRV measures, confirming a parasympathetic contribution to this phase.
Resumo:
Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 ± 2.63 years old) and 16 postmenopausal (57 ± 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg-1 min-1), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg-1 min-1) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (r s = 0.75) and VCO2 (r s = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.
Resumo:
We determined the response characteristics and functional correlates of the dynamic relationship between the rate (Δ) of oxygen consumption ( O2) and the applied power output (work rate = WR) during ramp-incremental exercise in patients with mitochondrial myopathy (MM). Fourteen patients (7 males, age 35.4 ± 10.8 years) with biopsy-proven MM and 10 sedentary controls (6 males, age 29.0 ± 7.8 years) took a ramp-incremental cycle ergometer test for the determination of the
O2 on-exercise mean response time (MRT) and the gas exchange threshold (GET). The Δ
O2/ΔWR slope was calculated up to GET (S1), above GET (S2) and over the entire linear portion of the response (S T). Knee muscle endurance was measured by isokinetic dynamometry. As expected, peak
O2 and muscle performance were lower in patients than controls (P < 0.05). Patients had significantly lower Δ
O2/ΔWR than controls, especially the S2 component (6.8 ± 1.5 vs 10.3 ± 0.6 mL·min-1·W-1, respectively; P < 0.001). There were significant relationships between Δ
O2/ΔWR (S T) and muscle endurance, MRT-
O2, GET and peak
O2 in MM patients (P < 0.05). In fact, all patients with Δ
O2/ΔWR below 8 mL·min-1·W-1 had severely reduced peak
O2 values (<60% predicted). Moreover, patients with higher cardiopulmonary stresses during exercise (e.g., higher Δ ventilation/carbon dioxide output and Δ heart rate/Δ
O2) had lower Δ
O2/ΔWR (P < 0.05). In conclusion, a readily available, effort-independent index of aerobic dysfunction during dynamic exercise (Δ
O2/ΔWR) is typically reduced in patients with MM, being related to increased functional impairment and higher cardiopulmonary stress.
Resumo:
It is common knowledge of the world’s dependency on fossil fuel for energy, its unsustainability on the long run and the changing trend towards renewable energy as an alternative energy source. This aims to cut down greenhouse gas emission and its impact on the rate of ecological and climatic change. Quite remarkably, wind energy has been one of many focus areas of renewable energy sources and has attracted lots of investment and technological advancement. The objective of this research is to explore wind energy and its application in household heating. This research aims at applying experimental approach in real time to study and verify a virtually simulated wind powered hydraulic house heating system. The hardware components comprise of an integrated hydraulic pump, flow control valve, hydraulic fluid and other hydraulic components. The system design and control applies hardware in-the-loop (HIL) simulation setup. Output signal from the semi-empirical turbine modelling controls the integrated motor to generate flow. Throttling the volume flow creates pressure drop across the valve and subsequently thermal power in the system to be outputted using a heat exchanger. Maximum thermal power is achieved by regulating valve orifice to achieve optimum system parameter. Savonius rotor is preferred for its low inertia, high starting torque and ease of design and maintenance characteristics, but lags in power efficiency. A prototype turbine design is used; with power output in range of practical Savonius turbine. The physical mechanism of the prototype turbine’s augmentation design is not known and will not be a focus in this study.
Resumo:
Energy scenarios are used as a tool to examine credible future states and pathways. The one who constructs a scenario defines the framework in which the possible outcomes exist. The credibility of a scenario depends on its compatibility with real world experiences, and on how well the general information of the study, methodology, and originality and processing of data are disclosed. In the thesis, selected global energy scenarios’ transparency and desirability from the society’s point of view were evaluated based on literature derived criteria. The global energy transition consists of changes to social conventions and economic development in addition to technological development. Energy solutions are economic and ethical choices due to far-reaching impacts of energy decision-making. Currently the global energy system is mostly based on fossil fuels, which is unsustainable over the long-term due to various reasons: negative climate change impacts, negative health impacts, depletion of fossil fuel reserves, resource-use conflicts with water management and food supply, loss of biodiversity, challenge to preserve ecosystems and resources for future generations, and inability of fossil fuels to provide universal access to modern energy services. Nuclear power and carbon capture and storage cannot be regarded as sustainable energy solutions due to their inherent risks and required long-term storage. The energy transition is driven by a growing energy demand, decreasing costs of renewables, modularity and scalability of renewable technologies, macroeconomic benefits of using renewables, investors’ risk awareness, renewable energy related attractive business opportunities, almost even distribution of solar and wind resources on the planet, growing awareness of the planet’s environmental status, environmental movements and tougher environmental legislation. Many of the investigated scenarios identified solar and wind power as a backbone for future energy systems. The scenarios, in which the solar and wind potentials were deployed in largest scale, met best the set out sustainability criteria. In future research, energy scenarios’ transparency can be improved by better disclosure on who has ordered the study, clarifying the funding, clearly referencing to used sources and indicating processed data, and by exploring how variations in cost assumptions and deployment of technologies influence on the outcomes of the study.
Resumo:
Central Governor Model (CGM) suggests that perturbations in the rate of heat storage (AS) are centrally integrated to regulate exercise intensity in a feed-forward fashion to prevent excessive thermal strain. We directly tested the CGM by manipulating ambient temperature (Tam) at 20-minute intervals from 20°C to 35°C, and returning to 20°C, while cycling at a set rate of perceived exertion (RPE). The synchronicity of power output (PO) with changes in HS and Tam were quantified using Auto-Regressive Integrated Moving Averages analysis. PO fluctuated irregularly but was not significantly correlated to changes in thermo physiological status. Repeated measures indicated no changes in lactate accumulation. In conclusion, real time dynamic sensation of Tam and integration of HS does not directly influence voluntary pacing strategies during sub-maximal cycling at a constant RPE while non-significant changes in blood lactate suggest an absence of peripheral fatigue.
Resumo:
The electromyographic threshold (EMGTh), defined as an upward inflexion in the rising EMG signal during progressive exercise, is thought to reflect the onset of increased type-II MU recruitment. The study’s objective was to compare the relative exercise intensity at which the EMGTh occurs in boys vs. men. Participants included 21 men (23.4±4.1 yrs) and 23 boys (11.1±1.1 yrs). Ramped cycle-ergometry was conducted to volitional exhaustion with surface EMG recorded from the vastus lateralis muscles. The EMGTh was mathematically determined using a composite of both legs. EMGTh was detected in 95.2% of the men and in 78.3% of the boys (χ2(1, n=44) =2.69, p =.10). The boys’ EMGTh was significantly higher than the men’s (86.4±9.6 vs. 79.7±10.0% of peak power-output at exhaustion; p <.05). These findings suggest that boys activate their type-II MUs to a lesser extent than men during progressive exercise and support the hypothesis of differential child–adult MU activation.
Resumo:
Abstract Background Children have been shown to have higher lactate (LaTh) and ventilatory (VeTh) thresholds than adults, which might be explained by lower levels of type-II motor-unit (MU) recruitment. However, the electromyographic threshold (EMGTh), regarded as indicating the onset of accelerated type-II MU recruitment, has been investigated only in adults. Purpose To compare the relative exercise intensity at which the EMGTh occurs in boys versus men. Methods Participants were 21 men (23.4 ± 4.1 years) and 23 boys (11.1 ± 1.1 years), with similar habitual physical activity and peak oxygen consumption (VO2pk) (49.7 ± 5.5 vs. 50.1 ± 7.4 ml kg−1 min−1, respectively). Ramped cycle ergometry was conducted to volitional exhaustion with surface EMG recorded from the right and left vastus lateralis muscles throughout the test (~10 min). The composite right–left EMG root mean square (EMGRMS) was then calculated per pedal revolution. The EMGTh was then determined as the exercise intensity at the point of least residual sum of squares for any two regression line divisions of the EMGRMS plot. Results EMGTh was detected in 20/21 of the men (95.2 %) and only in 18/23 of the boys (78.3 %). The boys’ EMGTh was significantly higher than the men’s (86.4 ± 9.6 vs. 79.7 ± 10.0 % of peak power output at exhaustion; p < 0.05). The pattern was similar when EMGTh was expressed as percentage of VO2pk. Conclusions The boys’ higher EMGTh suggests delayed and hence lesser utilization of type-II MUs in progressive exercise, compared with men. The boys–men EMGTh differences were of similar magnitude as those shown for LaTh and VeTh, further suggesting a common underlying factor.
Resumo:
L’exercice en immersion dans l'eau peut générer des réponses hémodynamiques et cardiorespiratoires différentes à celles de l’exercice sur terraine sec. Cependant, aucune étude n’a comparé ces réponses sur vélo aquatique (VA) à celles sur vélo sur terrain sec (VS) à une même puissance mécanique externe (Pext). À cet égard, le premier travail de cette thèse visait, d’abord, à trouver les équivalences de Pext lors du pédalage sur VA en immersion à la poitrine par rapport au VS au laboratoire, en considérant que cela restait non déterminé à ce jour. Une équation de mécanique des fluides fut utilisée pour calculer la force déployée pour le système de pédalage (pales, leviers, pédales) et des jambes à chaque tour de pédale. Ensuite, cette force totale a été multipliée par la vitesse de pédalage pour estimer la Pext sur VA. Ayant trouvé les équivalences de Pext sur VA et VS, nous nous sommes fixés comme objectif dans la deuxième étude de comparer les réponses hémodynamiques et cardiorespiratoires lors d'un exercice maximal progressif sur VS par rapport au VA à une même Pext. Les résultats ont montré que le VO2 (p<0.0001) et la différence artério-veineuse (C(a-v)O2) (p<0.0001) étaient diminués lors de l’exercice sur VA comparativement à celui sur VS. Parmi les variables hémodynamiques, le volume d’éjection systolique (VES) (p˂0.05) et le débit cardiaque (Qc) (p˂0.05) étaient plus élevés sur VA. En plus, on nota une diminution significative de la fréquence cardiaque (FC) (p˂0.05). Étant donné qu’à une même Pext les réponses physiologiques sont différentes sur VA par rapport à celles sur VS, nous avons effectué une troisième étude pour établir la relation entre les différentes expressions de l'intensité relative de l'exercice (% du VO2max,% de la FCmax,% du VO2 de réserve (% de VO2R) et % de la FC réserve (% FCR)). Les résultats ont démontré que la relation % FCR vs % VO2R était la plus corrélée (régression linéaire) et la plus proche de la ligne d’identité. Ces résultats pourraient aider à mieux prescrire et contrôler l’intensité de l'exercice sur VA pour des sujets sains. Finalement, une dernière étude comparant la réactivation parasympathique après un exercice maximal incrémental effectué sur VA et VS en immersion au niveau de la poitrine a montré que la réactivation parasympathique à court terme était plus prédominante sur VA (i,e. t, delta 10 à delta 60 et T30, p<0.05). Cela suggérait, qu’après un exercice maximal sur VA, la réactivation parasympathique à court terme était accélérée par rapport à celle après l'effort maximal sur VS chez de jeunes sujets sains. En conclusion, nous proposons une méthode de calcul de la puissance mécanique externe sur VA en fonction de la cadence de pédalage. Nous avons démontré que pendant l’exercice sur VA les réponses hémodynamiques et cardiorespiratoires sont différentes de celles sur VS à une même Pext et nous proposons des équations pour le calcul du VO2 dans l’eau ainsi qu’une méthode pour la prescription et le contrôle de l’exercice sur VA. Finalement, la réactivation parasympathique à court terme s’est trouvée accélérée après un effort maximal incrémental sur VA comparativement à celle sur VS.
Resumo:
La pratique d’activité physique fait partie intégrante des recommandations médicales pour prévenir et traiter les maladies coronariennes. Suivant un programme d’entraînement structuré, serait-il possible d’améliorer la réponse à l’exercice tout en offrant une protection cardiaque au patient? C’est ce que semblent démontrer certaines études sur le préconditionnement ischémique (PCI) induit par un test d’effort maximal. Les mêmes mécanismes physiologiques induits par le PCI sont également observés lorsqu’un brassard est utilisé pour créer des cycles d’ischémie/reperfusion sur un muscle squelettique. Cette méthode est connue sous l’appellation : préconditionnement ischémique à distance (PCID). À l’autre extrémité du spectre de l’activité physique, des sportifs ont utilisé le PCDI durant leur échauffement afin d’améliorer leurs performances. C’est dans l’objectif d’étudier ces prémisses que se sont construits les projets de recherches suivants. La première étude porte sur les effets du PCID sur des efforts supra maximaux de courte durée. Les sujets (N=16) ont exécuté un test alactique (6 * 6 sec. supra maximales) suivi d’un test lactique (30 secondes supra maximales) sur ergocycle. Les sujets avaient été aléatoirement assignés à une intervention PCID ou à une intervention contrôle (CON) avant d’entreprendre les efforts. La procédure PCID consiste à effectuer quatre cycles d’ischémie de cinq minutes à l’aide d’un brassard insufflé à 50 mm Hg de plus que la pression artérielle systolique sur le bras. Les résultats de ce projet démontrent que l’intervention PCID n’a pas d’effets significatifs sur l’amélioration de performance provenant classiquement du « système anaérobie », malgré une légère hausse de la puissance maximal en faveur du PCID sur le test de Wingate de trente secondes (795 W vs 777 W) et sur le test de force-vitesse de six secondes (856 W vs 847 W). Le deuxième essai clinique avait pour objectif d’étudier les effets du PCID, selon la méthode élaborée dans le premier projet, lors d’un effort modéré de huit minutes (75 % du seuil ventilatoire) et un effort intense de huit minutes (115 % du seuil ventilatoire) sur les cinétiques de consommation d’oxygène. Nos résultats démontrent une accélération significative des cinétiques de consommation d’oxygène lors de l’intervention PCID par rapport au CON aux deux intensités d’effort (valeur de τ1 à effort modéré : 27,2 ± 4,6 secondes par rapport à 33,7 ± 6,2, p < 0,01 et intense : 29,9 ± 4,9 secondes par rapport à 33,5 ± 4,1, p < 0,001) chez les sportifs amateurs (N=15). Cela se traduit par une réduction du déficit d’oxygène en début d’effort et une atteinte plus rapide de l’état stable. Le troisième projet consistait à effectuer une revue systématique et une méta-analyse sur la thématique du préconditionnement ischémique (PCI) induit par un test d’effort chez les patients coronariens utilisant les variables provenant de l’électrocardiogramme et des paramètres d’un test d’effort. Notre recherche bibliographique a identifié 309 articles, dont 34 qui ont été inclus dans la méta-analyse, qui représente un lot de 1 053 patients. Nos analyses statistiques démontrent que dans un effort subséquent, les patients augmentent leur temps avant d’atteindre 1 mm de sous-décalage du segment ST de 91 secondes (p < 0,001); le sous-décalage maximal diminue de 0,38 mm (p < 0,01); le double produit à 1 mm de sous-décalage du segment ST augmente de 1,80 x 103 mm Hg (p < 0,001) et le temps total d’effort augmente de 50 secondes (p < 0,001). Nos projets de recherches ont favorisé l’avancement des connaissances en sciences de l’activité physique quant à l’utilisation d’un brassard comme stimulus au PCID avant un effort physique. Nous avons évalué l’effet du PCID sur différentes voies métaboliques à l’effort pour conclure que la méthode pourrait accélérer les cinétiques de consommation d’oxygène et ainsi réduire la plage du déficit d’oxygène. Nos découvertes apportent donc un éclaircissement quant à l’amélioration des performances de type contre-la-montre étudié par d’autres auteurs. De plus, nous avons établi des paramètres cliniques permettant d’évaluer le PCI induit par un test d’effort chez les patients coronariens.
Resumo:
The thesis mainly focuses on material characterization in different environments: freely available samples taken in planar fonn, biological samples available in small quantities and buried objects.Free space method, finds many applications in the fields of industry, medicine and communication. As it is a non-contact method, it can be employed for monitoring the electrical properties of materials moving through a conveyor belt in real time. Also, measurement on such systems at high temperature is possible. NID theory can be applied to the characterization of thin films. Dielectric properties of thin films deposited on any dielectric substrate can be determined. ln chemical industry, the stages of a chemical reaction can be monitored online. Online monitoring will be more efficient as it saves time and avoids risk of sample collection.Dielectric contrast is one of the main factors, which decides the detectability of a system. lt could be noted that the two dielectric objects of same dielectric constant 3.2 (s, of plastic mine) placed in a medium of dielectric constant 2.56 (er of sand) could even be detected employing the time domain analysis of the reflected signal. This type of detection finds strategic importance as it provides solution to the problem of clearance of non-metallic mines. The demining of these mines using the conventional techniques had been proved futile. The studies on the detection of voids and leakage in pipes find many applications.The determined electrical properties of tissues can be used for numerical modeling of cells, microwave imaging, SAR test etc. All these techniques need the accurate determination of dielectric constant. ln the modem world, the use of cellular and other wireless communication systems is booming up. At the same time people are concemed about the hazardous effects of microwaves on living cells. The effect is usually studied on human phantom models. The construction of the models requires the knowledge of the dielectric parameters of the various body tissues. lt is in this context that the present study gains significance. The case study on biological samples shows that the properties of normal and infected body tissues are different. Even though the change in the dielectric properties of infected samples from that of normal one may not be a clear evidence of an ailment, it is an indication of some disorder.ln medical field, the free space method may be adapted for imaging the biological samples. This method can also be used in wireless technology. Evaluation of electrical properties and attenuation of obstacles in the path of RF waves can be done using free waves. An intelligent system for controlling the power output or frequency depending on the feed back values of the attenuation may be developed.The simulation employed in GPR can be extended for the exploration of the effects due to the factors such as the different proportion of water content in the soil, the level and roughness of the soil etc on the reflected signal. This may find applications in geological explorations. ln the detection of mines, a state-of-the art technique for scanning and imaging an active mine field can be developed using GPR. The probing antenna can be attached to a robotic arm capable of three degrees of rotation and the whole detecting system can be housed in a military vehicle. In industry, a system based on the GPR principle can be developed for monitoring liquid or gas through a pipe, as pipe with and without the sample gives different reflection responses. lt may also be implemented for the online monitoring of different stages of extraction and purification of crude petroleum in a plant.Since biological samples show fluctuation in the dielectric nature with time and other physiological conditions, more investigation in this direction should be done. The infected cells at various stages of advancement and the normal cells should be analysed. The results from these comparative studies can be utilized for the detection of the onset of such diseases. Studying the properties of infected tissues at different stages, the threshold of detectability of infected cells can be determined.
Resumo:
Die Maßnahmen zur Förderung der Windenergie in Deutschland haben wichtige Anstöße zur technologischen Weiterentwicklung geliefert und die Grundlagen für den enormen Anlagenzubau geschaffen. Die installierte Windleistung hat heute eine beachtliche Größenordnung erreicht und ein weiteres Wachstum in ähnlichen Dimensionen ist auch für die nächsten Jahre zu erwarten. Die aus Wind erzeugte elektrische Leistung deckt bereits heute in einigen Netzbereichen die Netzlast zu Schwachlastzeiten. Dies zeigt, dass die Windenergie ein nicht mehr zu vernachlässigender Faktor in der elektrischen Energieversorgung geworden ist. Im Rahmen der Kraftwerkseinsatzplanung sind Betrag und Verlauf der Windleistung des folgenden Tages mittlerweile zu wichtigen und zugleich schwierig zu bestimmenden Variablen geworden. Starke Schwankungen und falsche Prognosen der Windstromeinspeisung verursachen zusätzlichen Bedarf an Regel- und Ausgleichsleistung durch die Systemführung. Das im Rahmen dieser Arbeit entwickelte Prognosemodell liefert die zu erwartenden Windleistungen an 16 repräsentativen Windparks bzw. Gruppen von Windparks für bis zu 48 Stunden im Voraus. Aufgrund von prognostizierten Wetterdaten des deutschen Wetterdienstes (DWD) werden die Leistungen der einzelnen Windparks mit Hilfe von künstlichen neuronalen Netzen (KNN) berechnet. Diese Methode hat gegenüber physikalischen Verfahren den Vorteil, dass der komplexe Zusammenhang zwischen Wettergeschehen und Windparkleistung nicht aufwendig analysiert und detailliert mathematisch beschrieben werden muss, sondern anhand von Daten aus der Vergangenheit von den KNN gelernt wird. Das Prognosemodell besteht aus zwei Modulen. Mit dem ersten wird, basierend auf den meteorologischen Vorhersagen des DWD, eine Prognose für den Folgetag erstellt. Das zweite Modul bezieht die online gemessenen Leistungsdaten der repräsentativen Windparks mit ein, um die ursprüngliche Folgetagsprognose zu verbessern und eine sehr genaue Kurzzeitprognose für die nächsten drei bis sechs Stunden zu berechnen. Mit den Ergebnissen der Prognosemodule für die repräsentativen Standorte wird dann über ein Transformationsmodell, dem so genannten Online-Modell, die Gesamteinspeisung in einem größeren Gebiet berechnet. Das Prognoseverfahren hat seine besonderen Vorzüge in der Genauigkeit, den geringen Rechenzeiten und den niedrigen Betriebskosten, da durch die Verwendung des bereits implementierten Online-Modells nur eine geringe Anzahl von Vorhersage- und Messstandorten benötigt wird. Das hier vorgestellte Prognosemodell wurde ursprünglich für die E.ON-Netz GmbH entwickelt und optimiert und ist dort seit Juli 2001 im Einsatz. Es lässt sich jedoch auch leicht an andere Gebiete anpassen. Benötigt werden dazu nur die Messdaten der Leistung ausgewählter repräsentativer Windparks sowie die dazu gehörenden Wettervorhersagen, um die KNN entsprechend zu trainieren.