975 resultados para Skin temperature
Temperature variation and emergency hospital admissions for stroke in Brisbane, Australia, 1996-2005
Resumo:
Stroke is a leading cause of disability and death. This study evaluated the association between temperature variation and emergency admissions for stroke in Brisbane, Australia. Daily emergency admissions for stroke, meteorologic and air pollution data were obtained for the period of January 1996 to December 2005. The relative risk of emergency admissions for stroke was estimated with a generalized estimating equations (GEE) model. For primary intracerebral hemorrhage (PIH) emergency admissions, the average daily PIH for the group aged < 65 increased by 15% (95% Confidence Interval (CI): 5, 26%) and 12% (95% CI: 2, 22%) for a 1°C increase in daily maximum temperature and minimum temperature in summer, respectively, after controlling for potential confounding effects of humidity and air pollutants. For ischemic stroke (IS) emergency admissions, the average daily IS for the group aged ≥ 65 decreased by 3% (95% CI: -6, 0%) for a 1°C increase in daily maximum temperature in winter after adjustment for confounding factors. Temperature variation was significantly associated with emergency admissions for stroke, and its impact varied with different type of stroke. Health authorities should pay greater attention to possible increasing emergency care for strokes when temperature changes, in both summer and winter.
Resumo:
Survival from melanoma is strongly related to tumour thickness, thus earlier diagnosis has the potential to reduce mortality from this disease. However, in the absence of conclusive evidence that clinical skin examination reduces mortality, evidence-based assessments do not recommend population screening. We aimed to assess whether clinical whole-body skin examination is associated with a reduced incidence of thick melanoma and also whether screening is associated with an increased incidence of thin lesions (possible overdiagnosis). A population-based case-control study of all Queensland residents aged 20-75 years with a histologically confirmed first primary invasive cutaneous melanoma diagnosed between January 2000 and December 2003. Telephone interviews were completed by 3,762 eligible cases (78.0%) and 3,824 eligible controls (50.4%) Whole-body clinical skin examination in the three years before diagnosis was associated with a 14% lower risk of being diagnosed with a thick melanoma (>0.75mm) (OR= 0.86, 95% CI=0.75, 0.98). Risk decreased for melanomas of increasing thickness: the risk of being diagnosed with a melanoma 0.76-1.49mm was reduced by 7% (OR=0.93, 95% CI 0.79, 1.10), by 17% for melanomas 1.50-2.99mm (OR=0.83, 95% CI=0.65, 1.05) and by 40% for melanomas ≥3mm (OR=0.60, 95% CI=0.43, 0.83). Screening was associated with a 38% higher risk of being diagnosed with a thin invasive melanoma (≤0.75mm) (OR=1.38, 95% CI=1.22, 1.56). This is the strongest evidence to date that whole-body clinical skin examination reduces the incidence of thick melanoma. Because survival from melanoma is strongly related to tumour thickness, these results suggest that screening would reduce melanoma mortality.
Resumo:
Background: Incidence and mortality from skin cancers including melanoma are highest among men 50 years or older. Thorough skin self-examination may be beneficial to improve skin cancers outcomes.--------- Objectives: To develop and conduct a randomized-controlled trial of a video-based intervention to improve skin self-examination behavior among men 50 years or older.--------- Methods: Pilot work ascertained appropriate targeting of the 12-minute intervention video towards men 50 years or older. Overall, 968 men were recruited and 929 completed baseline telephone assessment. Baseline analysis assessed randomization balance and demographic, skin cancer risk and attitudinal factors associated with conducting a whole-body skin self-examination or receiving a whole-body clinical skin examination by a doctor during the past 12 months.--------- Results: Randomization resulted in well-balanced intervention and control groups. Overall 13% of men reported conducting a thorough skin self-examination using a mirror or the help of another person to check difficult to see areas, while 39% reported having received a whole-body skin examination by a doctor within the past 12 months. Confidence in finding time for and receiving advice or instructions by a doctor to perform a skin self-examination were among the factors associated with thorough skin self-examination at baseline.---------- Conclusions: Men 50 years or older can successfully be recruited to a video-based intervention trial with the aim reduce their burden through skin cancer. Randomization by computer generated randomization list resulted in good balance between control and intervention group and baseline analysis determined factors associated with skin cancer early detection behavior at baseline.
Resumo:
To assess the effects of any interventions which aim to prevent or manage radiation-induced skin reactions in people with cancer.
Resumo:
Zeolite N was produced from a variety of kaolinites and montmorillonites at low temperature (b100 °C) in a constantly stirred reactor using potassic and potassic+sodic mother liquors with chloride or hydroxyl anions. Reactions were complete (N95% product) in less than 20 h depending on initial batch composition and type of clay minerals. Zeolite N with 1.0bSi/Alb2.2 was produced under these conditions using KOH in the presence of KCl, NaCl, KCl+NaCl and KCl+NaOH. Zeolite N was also formed under high potassium molarities in the absence of KCl. Zeolite synthesis was more sensitive to water content and temperature when sodium was used in initial batch compositions. Syntheses of zeolite N by these methods were undertaken at bench, pilot and industrial scales.
Resumo:
Hot and cold temperatures significantly increase mortality rates around the world, but which measure of temperature is the best predictor of mortality is not known. We used mortality data from 107 US cities for the years 1987–2000 and examined the association between temperature and mortality using Poisson regression and modelled a non-linear temperature effect and a non-linear lag structure. We examined mean, minimum and maximum temperature with and without humidity, and apparent temperature and the Humidex. The best measure was defined as that with the minimum cross-validated residual. We found large differences in the best temperature measure between age groups, seasons and cities, and there was no one temperature measure that was superior to the others. The strong correlation between different measures of temperature means that, on average, they have the same predictive ability. The best temperature measure for new studies can be chosen based on practical concerns, such as choosing the measure with the least amount of missing data.
Resumo:
Cold-formed steel beams are increasingly used as floor joists and bearers in residential, industrial and commercial buildings. Their structural behaviour and moment capacities are influenced by lateral-torsional buckling and hence a research study was undertaken to investigate the lateral-torsional buckling behaviour of cold-formed steel lipped channel beams at ambient and elevated temperatures. For this purpose a finite element model of a simply supported cold-formed steel lipped channel beam under uniform bending was developed first and validated using available numberical and experimental results. It was then used in a detailed parametric study to simulate the lateral-torsional behaviour of cold-formed steel beams under varying conditions. The moment capacity results were then compared with the predictions from the current ambient temperature design rules in Australia, New Zealand, American and European codes for cold-formed steel structures. Some very interesting results have been obtained. European design rules are found to be conservative while Australian and American design rules are unsafe. This paper presents the results of finite element analyses for ambient temperature conditions, and the comparison with the current design rules.
Resumo:
Smart materials, such as thin-film piezoelectric polymers, are interesting for potential applications on Gossamer spacecraft. This investigation aims to predict the performance and long-term stability of the piezoelectric properties of poly(vinylidene fluoride) (PVDF) and its copolymers under conditions simulating the low-Earthorbit environment. To examine the effects of temperature on the piezoelectric properties of PVDF, poly(vinylidenefluoride-co-trifluoroethylene), and poly(vinylidenefluoride-cohexafluoropropylene), the d33 piezoelectric coefficients were measured up to 160 8C, and the electric displacement/electric field (D–E) hysteresis loops were measured from �80 to þ110 8C. The room-temperature d33 coefficient of PVDF homopolymer films, annealed at 50, 80, and 125 8C, dropped rapidly within a few days of thermal exposure and then remained unchanged. In contrast, the TrFE copolymer exhibited greater thermal stability than the homopolymer, with d33 remaining almost unchanged up to 125 8C. The HFP copolymer exhibited poor retention of d33 at temperatures above 80 8C. In situ D–E loop measurements from �80 to þ110 8C showed that the remanent polarization of the TrFE copolymer was more stable than that of the PVDF homopolymer. D–E hysteresis loop and d33 results were also compared with the deflection of the PVDF homopolymer and TrFE copolymer bimorphs tested over a wide temperature range.
Resumo:
Current-voltage (I-V) curves of Poly(3-hexyl-thiophene) (P3HT) diodes have been collected to investigate the polymer hole-dominated charge transport. At room temperature and at low electric fields the I-V characteristic is purely Ohmic whereas at medium-high electric fields, experimental data shows that the hole transport is Trap Dominated - Space Charge Limited Current (TD-SCLC). In this regime, it is possible to extract the I-V characteristic of the P3HT/Al junction showing the ideal Schottky diode behaviour over five orders of magnitude. At high-applied electric fields, holes’ transport is found to be in the trap free SCLC regime. We have measured and modelled in this regime the holes’ mobility to evaluate its dependence from the electric field applied and the temperature of the device.