949 resultados para Simple L-Modules
Resumo:
Patients with intractably diminished bladder storage function are encountered frequently by neurourologists, occasionally requiring reconstructive surgery for appropriate resolution. Although sacral neuromodulation is a recognized effective therapeutic modality, present techniques are technically demanding, invasive, and expensive. This study investigated the effect of non-invasive third sacral nerve (S3) stimulation on bladder activity during filling cystometry. One hundred forty-six patients underwent standard urodynamic filling cystometry that was then immediately repeated. Patients in the study group (n = 74) received antidromic transcutaneous sacral neurostimulation during the second fill and the control group (n = 72) underwent a second fill without neurostimulation. A statistically significant increase in bladder storage capacity without a corresponding rise in detrusor pressure was observed in the neurostimulated patients. This improvement in functional capacity is an encouraging finding that further supports the use of this non-invasive treatment modality in clinical practice. Neurourol. Urodynam. 20:73-84. 2001. (C) 2001 Wiley-Liss, Inc.
Resumo:
Insulated gate bipolar transistor (IGBT) modules are important safety critical components in electrical power systems. Bond wire lift-off, a plastic deformation between wire bond and adjacent layers of a device caused by repeated power/thermal cycles, is the most common failure mechanism in IGBT modules. For the early detection and characterization of such failures, it is important to constantly detect or monitor the health state of IGBT modules, and the state of bond wires in particular. This paper introduces eddy current pulsed thermography (ECPT), a nondestructive evaluation technique, for the state detection and characterization of bond wire lift-off in IGBT modules. After the introduction of the experimental ECPT system, numerical simulation work is reported. The presented simulations are based on the 3-D electromagnetic-thermal coupling finite-element method and analyze transient temperature distribution within the bond wires. This paper illustrates the thermal patterns of bond wires using inductive heating with different wire statuses (lifted-off or well bonded) under two excitation conditions: nonuniform and uniform magnetic field excitations. Experimental results show that uniform excitation of healthy bonding wires, using a Helmholtz coil, provides the same eddy currents on each, while different eddy currents are seen on faulty wires. Both experimental and numerical results show that ECPT can be used for the detection and characterization of bond wires in power semiconductors through the analysis of the transient heating patterns of the wires. The main impact of this paper is that it is the first time electromagnetic induction thermography, so-called ECPT, has been employed on power/electronic devices. Because of its capability of contactless inspection of multiple wires in a single pass, and as such it opens a wide field of investigation in power/electronic devices for failure detection, performance characterization, and health monitoring.
Resumo:
Two different mesoporous films of TiO2 were coated onto a QCM disc and fired at 450o C for 30 min. The first film was derived from a sol-gel paste that was popular in the early days of dye-sensitised solar cell, i.e. dssc, research, a TiO2(sg) film. The other was a commercial colloidal paste used to make examples of the current dssc cell; a TiO2(ds) film. A QCM was used to determine the mass of the TiO2 film deposited on each disc and the increase in the mass of the film when immersed in water/glycerol solutions with wt% values spanning the range 0-70%. The results of this work reveal that with both TiO2 mesoporous films the solution fills the film's pores and acts as a rigid mass, thereby allowing the porosity of each film to be calculated as: 59.1% and 71.6% for the TiO2(sg) and TiO2(ds) films, respectively. These results, coupled with surface area data, allowed the pore radii of the two films to be calculated as: 9.6 and 17.8 nm, respectively. This method is then simplified further, to just a few frequency measurements in water and only air to reveal the same porosity values. The value of the latter ‘one point’ method for making porosity measurements is discussed briefly.
Resumo:
Retrodirective, self-steering, antennas have the advantage of being able to automatically return a signal back in the direction along from which it originated. The tracking is real time and is carried out in the analogue domain which results in simple circuits which can be accommodated, planar-form, behind the antenna elements. The main objective of this paper is to detail the continuation of the work on L band retrodirective antennas which has the ambition of increasing the TRL such that a minimal viable product can be produced, suitable for type approval as an L band SATCOM user terminal. The focus will be the technical challenges that have arisen as the retrodirective antenna is moved up the TRL chain. Some of these aspects include the ability to track very weak modulated signals (S/N tending to 0dB), TX/RX filter and duplexer specifications, PA and LNA considerations. The resultant retrodirective architecture will be compared against typical specifications of L band satellite ground terminals, showing that the retrodirective antenna offers a simple and effective real time tracking antenna architecture.
Resumo:
La présente recherche porte sur la cohérence et la cohésion qu'il existe dans l'expression orale d'un jeune dysphasique du premier cycle du secondaire et dans la production écrite effectuée par celui-ci. Compte tenu du problème de langage parlé que présente entre autres la dysphasie, le risque de trouver le même problème est possiblement présent dans la production écrite. Cela a des répercussions au niveau scolaire dans l'expression de ses idées, l'apprentissage de l'écriture, peut-être même dans la compréhension de ce qu'il écoute et lit. Non seulement, cela a-t-il des conséquences dans les résultats académiques, mais aussi dans les relations sociales avec ses pairs et ses enseignants puisqu'il ne saisit pas certains énoncés du langage tels que des jeux de mots ou des métaphores. De plus, il a de la difficulté à exprimer clairement ses idées et ses opinions. Ces obstacles à l'expression orale et celle écrite peuvent éventuellement marginaliser le jeune dysphasique et le démotiver. Des études ont mis en évidence qu'il existe une relation entre le langage parlé et l'apprentissage de l'écriture : si le jeune dysphasique éprouve des difficultés à s'exprimer oralement, il en sera de même dans la production écrite. Toutefois, d'autres études démontrent que l'apprentissage de l'écriture aide à améliorer le langage oral. Toutes ces études ont été effectuées sur de jeunes enfants au niveau préscolaire ou au primaire; elles ont été faites à partir de textes narratifs restitués par des jeunes n'ayant par de problème de langage. Notre recherche, qui est exploratoire et descriptive, concerne des jeunes du premier cycle du secondaire et la collecte de données s'est faite à partir d'un texte courant. Elle visait deux objectifs spécifiques : premièrement, analyser la cohérence et la cohésion dans la restitution orale et celle écrite d'un sujet tout-venant et dans celles d'un jeune dysphasique; et deuxièmement, décrire les relations entre les restitutions des deux sujets. Pour ce faire, la collecte de données s'est déroulée de la manière suivante : nous avons demandé à deux jeunes de deuxième et troisième secondaires, l'un, tout-venant et l'autre, dysphasique, de restituer ce qu'ils se rappelaient de l'écoute d'un texte à dominante descriptive laquelle leur a été faite à tour de rôle. Dans un premier temps, ils devaient rappeler oralement le contenu du texte lu, et dans un deuxième temps, ils devaient écrire ce dont ils se souvenaient du même texte. Une fois les restitutions orales transcrites sous forme de Verbatim, elles ont été, tout comme les restitutions écrites, décrites et comparées entre elles selon les critères suivants : la cohérence (intégration et hiérarchisation et la cohésion (récurrence, coréférence, contiguïté sémantique et connecteurs). Les résultats obtenus montrent d'abord que les restitutions orales et écrites présentent des similitudes quant à la cohérence et la cohésion. Les restitutions écrites sont légèrement plus détaillées, c'est-à-dire quelques idées ont été ajoutées ou précisées. Par exemple, dans la restitution orale, comme dans celle écrite, le sujet tout-venant mentionne que les fourmis d'Argentine pourraient être "dangereuses pour les arbres fruitiers". Dans sa restitution écrite, il ajoute comme informations que ces insectes "aiment le sucre" et qu'elles "vont dans les maisons". Les observations montrent aussi une différence entre les restitutions du jeune toutvenant et celles du jeune dysphasique. Ce dernier rappelle les informations du texte de façon cohérente et presque complète alors que le sujet tout-venant ne restitue que les informations de la première partie, et ce, de la façon la plus simple, soit par l'énumération sans connecteurs autres que ceux de l'énumération. Par contre, le sujet tout-venant maîtrise les procédés cohésifs mieux que le sujet dysphasique. Quant à ce dernier, il semble mieux réussir à l'écrit qu'à l'oral. La compréhension des informations de façon globale et, peut-être, le type de texte influencent les résultats dans le rappel des informations. Le sujet dysphasique peut restituer les idées, et ce, de façon structurée s'il saisit bien l'idée globale du texte qu'il lui a été lu, mais la microstructure est moins maîtrisée, sauf l'utilisation des connecteurs qui a probablement un lien plus étroit - que les autres procédés cohésifs - avec la cohérence et la compréhension des idées. Donc, à partir de l'analyse des restitutions orale et écrite, il semble que le trouble de langage aurait des répercussions au niveau des procédés de la cohésion, sauf dans le cas des connecteurs. L'utilisation de ceux-ci et les procédés de cohérence sont maîtrisés par le jeune dysphasique qui a compris le contenu du texte qui lui a été lu.
Resumo:
The University of Worcester states in its most recent strategic plan (2013 – 2018) a set of enduring values that guide and direct the activities of the institution. The first listed, and perhaps the most important value is the striving to be “an outstanding university at which to be a student”. This is further supplemented by values such as “to inspire our students to reach their full potential through excellent, innovative teaching, scholarship and research” (University of Worcester 2013: p.4). One of the many ways in which the institution strives to provide this outstanding educational experience is through regular engagement, both formal and informal, with students at a number of points in each semester. Regular experiences of collating formal and informal feedback has led to the identification of a common theme amongst Higher National Diploma (HND) students in the Institute of Sport and Exercise Sciences (ISES), where they consistently request ‘more practicals’. The ISES modules however are designed to incorporate a high degree of interaction, practical activities and tasks. This is especially important for those studying at HND level as research suggests differences in learning preferences exist when compared to undergraduate students, the former preferring a more tactile style of learning (Peters et al. 2008). Using an introductory Sport Psychology HND module as an example, practical activities and tasks are fully embedded in the taught sessions to enable contextual links to be made between the learning outcomes and their subsequent use. Examples of these include: a. interviewing athletes to produce a performance profile (Butler & Hardy 1992); b. completing psychometric instruments such as the Competitive State Anxiety Inventory-2 (CSAI-2) to measure competitive anxiety in sport (Martens et al. 1990) and demonstrate data collection and construct measurement; c. performing relaxation interventions on the students to demonstrate how specific techniques (in this instance, decreasing somatic anxiety) might work in practice; d. demonstrating how observational learning facilitates skill acquisition by creating experimental conditions that the students participate in, in teaching a new skill. Nevertheless owing to the students' previously stated on-going requests for more practical activities, it became evident that assumptions about what students consider an effective means of experiential or active learning in the context of sport-related disciplines of study needed to be investigated. This is where the opportunity to undertake an action research project arose, this being a practical method commonly employed in pedagogical enquiry to aid reflection on teaching and assessment practice for the purposes of working towards continuous improvement.
Resumo:
The performance of an amperometric biosensor constructed by associating tyrosinase (Tyr) enzyme with the advantages of a 3D gold nanoelectrode ensemble (GNEE) is evaluated in a flow-injection analysis (FIA) system for the analysis of l-dopa. GNEEs were fabricated by electroless deposition of the metal within the pores of polycarbonate track-etched membranes. A simple solvent etching procedure based on the solubility of polycarbonate membranes is adopted for the fabrication of the 3D GNEE. Afterward, enzyme was immobilized onto preformed self-assembled monolayers of cysteamine on the 3D GNEEs (GNEE-Tyr) via cross-linking with glutaraldehyde. The experimental conditions of the FIA system, such as the detection potential (−0.200 V vs. Ag/AgCl) and flow rates (1.0 mL min−1) were optimized. Analytical responses for l-dopa were obtained in a wide concentration range between 1 × 10−8 mol L−1 and 1 × 10−2 mol L−1. The limit of quantification was found to be 1 × 10−8 mol L−1 with a resultant % RSD of 7.23% (n = 5). The limit of detection was found to be 1 × 10−9 mol L−1 (S/N = 3). The common interfering compounds, namely glucose (10 mmol L−1), ascorbic acid (10 mmol L−1), and urea (10 mmol L−1), were studied. The recovery of l-dopa (1 × 10−7 mol L−1) from spiked urine samples was found to be 96%. Therefore, the developed method is adequate to be applied in the clinical analysis.
Resumo:
Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.
A simple genetic basis for complex social behaviour mediates widespread gene expression differences.
Resumo:
A remarkable social polymorphism is controlled by a single Mendelian factor in the fire ant Solenopsis invicta. A genomic element marked by the gene Gp-9 determines whether workers tolerate one or many fertile queens in their colony. Gp-9 was recently shown to be part of a supergene with two nonrecombining variants, SB and Sb. SB/SB and SB/Sb queens differ in how they initiate new colonies, and in many physiological traits, for example odour and maturation rate. To understand how a single genetic element can affect all these traits, we used a microarray to compare gene expression patterns between SB/SB and SB/Sb queens of three different age classes: 1-day-old unmated queens, 11-day-old unmated queens and mated, fully reproductive queens collected from mature field colonies. The number of genes that were differentially expressed between SB/SB and SB/Sb queens of the same age class was smallest in 1-day-old queens, maximal in 11-day-old queens and intermediate in reproductive queens. Gene ontology analysis showed that SB/SB queens upregulate reproductive genes faster than SB/Sb queens. For all age classes, genes inside the supergene were overrepresented among the differentially expressed genes. Consistent with the hypothesized greater number of transposons in the Sb supergene, 13 transposon genes were upregulated in SB/Sb queens. Viral genes were also upregulated in SB/Sb mature queens, consistent with the known greater parasite load in colonies headed by SB/Sb queens compared with colonies headed by SB/SB queens. Eighteen differentially expressed genes between reproductive queens were involved in chemical signalling. Our results suggest that many genes in the supergene are involved in regulating social organization and queen phenotypes in fire ants.
Resumo:
La mesure de la fraction libre du magnésium circulant est désormais possible grâce aux électrodes sélectives. Lors d'une déplétion magnésique l'enquête étiologique est orientée par la comparaison de la magnésiurie et de la magnésémie. Les syndromes de Bortter, ou alcaloses hypokaliémiques d'origine rénale, sont des tubulopathies primitives définies par des signes simples: tension artérielle normale; alcalose hypokaliémiques; excrétion rénale conservée des chlorures et recherche de diurétiques négative dans les urines. Grâce à la mesure de la magnésémie et de la calciurie on distingue au moins deux alcaloses hypokaliémiques d'origine rénale, la maladie de Gitelman et le syndrome de Bartter au sens strict.
Resumo:
Geographical isolation and polyploidization are central concepts in plant evolution. The hierarchical organization of archipelagos in this study provides a framework for testing the evolutionary consequences for polyploid taxa and populations occurring in isolation. Using amplified fragment length polymorphism and simple sequence repeat markers, we determined the genetic diversity and differentiation patterns at three levels of geographical isolation in Olea europaea: mainland-archipelagos, islands within an archipelago, and populations within an island. At the subspecies scale, the hexaploid ssp. maroccana (southwest Morocco) exhibited higher genetic diversity than the insular counterparts. In contrast, the tetraploid ssp. cerasiformis (Madeira) displayed values similar to those obtained for the diploid ssp. guanchica (Canary Islands). Geographical isolation was associated with a high genetic differentiation at this scale. In the Canarian archipelago, the stepping-stone model of differentiation suggested in a previous study was partially supported. Within the western lineage, an east-to-west differentiation pattern was confirmed. Conversely, the easternmost populations were more related to the mainland ssp. europaea than to the western guanchica lineage. Genetic diversity across the Canarian archipelago was significantly correlated with the date of the last volcanic activity in the area/island where each population occurs. At the island scale, this pattern was not confirmed in older islands (Tenerife and Madeira), where populations were genetically homogeneous. In contrast, founder effects resulted in low genetic diversity and marked genetic differentiation among populations of the youngest island, La Palma.
Resumo:
Carbapenemases should be accurately and rapidly detected, given their possible epidemiological spread and their impact on treatment options. Here, we developed a simple, easy and rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based assay to detect carbapenemases and compared this innovative test with four other diagnostic approaches on 47 clinical isolates. Tandem mass spectrometry (MS-MS) was also used to determine accurately the amount of antibiotic present in the supernatant after 1 h of incubation and both MALDI-TOF and MS-MS approaches exhibited a 100% sensitivity and a 100% specificity. By comparison, molecular genetic techniques (Check-MDR Carba PCR and Check-MDR CT103 microarray) showed a 90.5% sensitivity and a 100% specificity, as two strains of Aeromonas were not detected because their chromosomal carbapenemase is not targeted by probes used in both kits. Altogether, this innovative MALDI-TOF-based approach that uses a stable 10-μg disk of ertapenem was highly efficient in detecting carbapenemase, with a sensitivity higher than that of PCR and microarray.
Resumo:
Introduction : Les fractures du membre inférieur (MI) de l'enfant traitées par immobilisation plâtrée engendrent une modification significative de la mobilité exacerbée en cas d'obésité. L'accéléromètre est un outil d'évaluation du degré d'activité physique (AP) de l'enfant scientifiquement validé. Il n'a jamais fait l'objet d'étude chez un enfant ayant souffert d'une fracture du MI. Le but de ce travail était d'identifier les problèmes dans l'utilisation d'un accéléromètre comme moyen de mesure de l'AP après fracture nécessitant une décharge du MI. Une adaptation de la réhabilitation post-traumatique en fonction du BMI pourrait alors être proposée. Méthode : Identification d'enfants âgés de 8 et 15 ans, victimes d'une fracture du membre inférieur, consultant aux urgences de l'Hôpital de l'Enfance d'octobre 2013 à mai 2014 et nécessitant une décharge post-traumatique. Etaient exclus les enfants polytraumatisés ou souffrants d'un déficit mental. Données pré-requises des patients: âge, poids, taille, sexe, mécanisme de l'accident, type de fracture et traitement. Proposition de port d'un Actiwatch® Spectrum au poignet et cheville pour la période de remobilisation en décharge. Identification des avantages et problèmes liés à l'usage de l'appareil durant les premiers 30 jours de la période de réhabilitation. Importance : L'absence totale d'étude sur la mobilité post-fracture, la complexité des problèmes liés à la marche en décharge, les contraintes de l'immobilisation plâtrée et la prévalence grandissante de l'obésité pédiatrique justifient la recherche d'un moyen fiable pour quantifier la mobilité d'un enfant en décharge après traumatisme du MI. Résultats : Sur 43 fractures du MI traitées à l'HEL durant la période de l'étude, 13 enfants identifiés, dont 1 exclu pour maladie psychiatrique, 1 refus de participation, 2 transferts immédiats, 2 non inclus pour causes pratiques. Sept garçons âgés de 11 à 16 ans ont accepté le port de l'Actiwatch® pour une durée variant entre 7 et 27 jours (moyenne 15). Nombre d'activités (NA) médians de 5 enfants: 171,79 ±105,37 [cpm]* à J1 et 219,48 ±145,52 [cpm] à J5. NA totales médianes sur 24h : 114'072±44'791 [cpm] à J1 et 234'452 ±134'775 [cpm] à J5. Une dynamique de regain de mobilité est mise en évidence avec intensités maximales et minimales du nombre d'activités pour chacun. La médiane du temps de sommeil des 5 enfants était de 716± 45,5 [mn]. Les problèmes rencontrés ont été d'ordre mécanique (Un Actiwatch® fut défectueux), d'ordre pratique (un perdu et rendu tardivement, un port intermittent, une réaction allergique au bracelet à 4j de port). Conclusions La compliance à l'utilisation de l'Actiwatch® sur toute la durée de la décharge n'était pas optimale. La mobilité moyenne des enfants était objectivable de par leur dynamique, leur intensité maximale et minimale et comparables vis-à-vis de certaines études. Une différence avec les sujets en surpoids est observable. La durée de sommeil de chaque enfant suggère que l'antalgie administrée en cours de traitement est suffisante. Utiliser ce capteur de manière prolongée et sur un grand collectif d'enfants serait un moyen fiable et simple d'objectiver la dynamique de reprise de l'activité physique chez ces patients. Profil de l'étude : observation de cas.