956 resultados para Scanline sampling technique
Resumo:
OBJECTIVES: Microneedle (MN) arrays could offer a pain-free, minimally invasive approach to monitoring. This is envisaged to be particularly beneficial for younger patients, but parents' views to date are unknown. The aim of this study was to explore parental perceptions of MN-mediated ISF monitoring, as an alternative to the use of conventional blood sampling, and to understand the important factors for technique approval.
METHODS: Semi-structured interviews were conducted with parents with recent experience of a premature birth. Recruitment was through the Northern Ireland premature infant charity, Tinylife. Interviews progressed until data saturation was reached and thematic analysis employed.
KEY FINDINGS: The study included 16 parents. Parental support for MN-mediated monitoring was evident, alongside the unpopularity of traditional blood sampling in neonates. Factors facilitating MN approval included the opportunity for pain reduction, the simplicity of the procedure, the potential for increased parental involvement and the more favourable appearance, owing to the minute size of MNs and similarities with a sticking plaster. Confirmation of correct application, a pain-free patch removal and endorsement from trusted healthcare professionals were important.
CONCLUSION: These findings will inform researchers in the field of MN development and enlighten practitioners regarding parental distress resulting from conventional blood sampling. Further work is necessary to understand MN acceptability among practitioners. This work should assist in the development of an acceptable MN device and facilitate the reduction of parental distress.
Resumo:
This paper introduces a novel method of estimating theFourier transform of deterministic continuous-time signals from a finite number N of their nonuniformly spaced measurements. These samples, located at a mixture of deterministic and random time instants, are collected at sub-Nyquist rates since no constraints are imposed on either the bandwidth or the spectral support of the processed signal. It is shown that the proposed estimation approach converges uniformly for all frequencies at the rate N^−5 or faster. This implies that it significantly outperforms its alias-free-sampling-based predecessors, namely stratified and antithetical stratified estimates, which are shown to uniformly convergence at a rate of N^−1. Simulations are presented to demonstrate the superior performance and low complexity of the introduced technique.
Resumo:
One of the most important measures to prevent wild forest fires is the use of prescribed and controlled burning actions as it reduce the fuel mass availability. The impact of these management activities on soil physical and chemical properties varies according to the type of both soil and vegetation. Decisions in forest management plans are often based on the results obtained from soil-monitoring campaigns. Those campaigns are often man-labor intensive and expensive. In this paper we have successfully used the multivariate statistical technique Robust Principal Analysis Compounds (ROBPCA) to investigate on the sampling procedure effectiveness for two different methodologies, in order to reflect on the possibility of simplifying and reduce the sampling collection process and its auxiliary laboratory analysis work towards a cost-effective and competent forest soil characterization.
Resumo:
The concentrations of the water-soluble inorganic aerosol species, ammonium (NH4+), nitrate (NO3-), chloride (Cl-), and sulfate (SO42-), were measured from September to November 2002 at a pasture site in the Amazon Basin (Rondnia, Brazil) (LBA-SMOCC). Measurements were conducted using a semi-continuous technique (Wet-annular denuder/Steam-Jet Aerosol Collector: WAD/SJAC) and three integrating filter-based methods, namely (1) a denuder-filter pack (DFP: Teflon and impregnated Whatman filters), (2) a stacked-filter unit (SFU: polycarbonate filters), and (3) a High Volume dichotomous sampler (HiVol: quartz fiber filters). Measurements covered the late dry season (biomass burning), a transition period, and the onset of the wet season (clean conditions). Analyses of the particles collected on filters were performed using ion chromatography (IC) and Particle-Induced X-ray Emission spectrometry (PIXE). Season-dependent discrepancies were observed between the WAD/SJAC system and the filter-based samplers. During the dry season, when PM2.5 (D-p <= 2.5 mu m) concentrations were similar to 100 mu g m(-3), aerosol NH4+ and SO42- measured by the filter-based samplers were on average two times higher than those determined by the WAD/SJAC. Concentrations of aerosol NO3- and Cl- measured with the HiVol during daytime, and with the DFP during day- and nighttime also exceeded those of the WAD/SJAC by a factor of two. In contrast, aerosol NO3- and Cl- measured with the SFU during the dry season were nearly two times lower than those measured by the WAD/SJAC. These differences declined markedly during the transition period and towards the cleaner conditions during the onset of the wet season (PM2.5 similar to 5 mu g m(-3)); when filter-based samplers measured on average 40-90% less than the WAD/SJAC. The differences were not due to consistent systematic biases of the analytical techniques, but were apparently a result of prevailing environmental conditions and different sampling procedures. For the transition period and wet season, the significance of our results is reduced by a low number of data points. We argue that the observed differences are mainly attributable to (a) positive and negative filter sampling artifacts, (b) presence of organic compounds and organosulfates on filter substrates, and (c) a SJAC sampling efficiency of less than 100%.
Resumo:
The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the mu g m(-3) range) and their variations with sampling site and time In this work a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE) a quick separation technique that requires nothing more than some nanoliters of sample and when combined with capacitively coupled contactless conductometric detection (C(4)D) is particularly favorable for ionic species that do not absorb in the UV-vis region like the target analytes formaldehyde formic acid acetic acid and ammonium The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry s constant such as formaldehyde and carboxylic acids or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8 3 nLs(-1)) while the sample was aspirated through the annular gap of the concentric tubes at 25 mLs(-1) A second unit in all similar to the CMDS was operated as a capillary membrane diffusion emitter (CMDE) generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS The fluids of the system were driven with inexpensive aquarium air pumps and the collected samples were stored in vials cooled by a Peltier element Complete protocols were developed for the analysis in air of NH(3) CH(3)COOH HCOOH and with a derivatization setup CH(2)O by associating the CMDS collection with the determination by CE-C(4)D The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot s reaction Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW) All techniques and methods of this work are in line with the green analytical chemistry trends (C) 2010 Elsevier B V All rights reserved
Resumo:
In situ fusion on the boat-type graphite platform has been used as a sample pretreatment for the direct determination of Co, Cr and Mn in Portland cement by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS). The 3-field Zeeman technique was adopted for background correction to decrease the sensitivity during measurements. This strategy allowed working with up to 200 mu g of sample. The in situ fusion was accomplished using 10 mu L of a flux mixture 4.0% m/v Na(2)CO(3) + 4.0% m/v ZnO + 0.1% m/v Triton (R) X-100 added over the cement sample and heated at 800 degrees C for 20 s. The resulting mould was completely dissolved with 10 mu L of 0.1% m/v HNO(3). Limits of detection were 0.11 mu g g(-1) for Co, 1.1 mu g g(-1) for Cr and 1.9 mu g g(-1) for Mn. The accuracy of the proposed method has been evaluated by the analysis of certified reference materials. The values found presented no statistically significant differences compared to the certified values (Student`s t-test, p<0.05). In general, the relative standard deviation was lower than 12% (n = 5). (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
O objetivo deste trabalho foi analizar a distribuição espacial da compactação do solo e a influência da umidade do solo na resistência à penetração. Esta última variável foi descrita pelo índice de cone. O solo estudado foi Nitossolo e os dados de índice de cone foram obtidos usando um penetrômetro. A resistência do solo foi avaliada a 5 profundidades diferentes, 0-10 cm, 10-20 cm, 20-30 cm, 30-40 cm e mais de 40 cm, porém o conteúdo de umidade do solo foi medido a 0-20 cm e 20-40 cm. As condições hídricas do solo variaram nas diferentes amostragems. Os coeficientes de variação para o índice de cone foram 16,5% a 45,8% e os do conteúdo de umidade do solo variaram entre 8,96% e 21,38%. Os resultados sugeriram elevada correlação entre a resistência do solo, estimada pelo índice de cone e a profundidade do solo. Sem embargo, a relação esperada com a umidade do solo não foi apreciada. Observou-se dependência espacial em 31 de 35 séries de dados de índice de cone e umidade do solo. Esta dependência foi ajustada por modelos exponenciais com efeito pepita variável de 0 a 90% o valor do patamar. em séries de dados o comportamento foi aleatório. Portanto, a técnica das distâncias inversas foi utilizada para cartografar a distribuição das variáveis que não tiveram estrutura espacial. Na krigagem constatou-se uma suavização dos mapas comparados com esses das distâncias inversas. A krigagem indicadora foi utilizada para cartografar a variabilidade espacial do índice de cone e recomendar melhor manejo do solo.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work describes the foraging techniques, body positions and behavior of free-ranging Ingram's squirrel Guerlinguetus ingrami Thomas, 1901 in a region of the Araucaria moist forest, in the Atlantic Forest of southern Brazil. The animals were observed using the all occurrence sampling method with the aid of binoculars and a digital camcorder. All behaviors were described in diagrams and an ethogram. We recorded five basic body positions, 24 behaviors, two food choices, and three feeding strategies utilized to open fruits of Syagrus romanzoffiana (Cham.), the main food source of Ingram's squirrels. We also observed a variance in the animals' stance, which is possibly influenced by predation risk, and discuss the causes of some behaviors.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In the seed production system, genetic purity is one of the fundamental requirements for its commercialization. The present work had the goal of determined the sample size for genetic purity evaluation, in order to protect the seed consumer and the producer and to evaluate the sensitivity of microsatellite technique for discriminating hybrids from their respective relatives and for detecting mixtures when they are present in small amounts in the samples. For the sequential sampling, hybrid seeds were marked and mixed in with the seed lots, simulating the following levels of contamination: 0.25, 0.5, 1.0, 2.0, 4.0, and 6.0%. After this, groups of 40 seeds were taken in sequence, up to a maximum of 400 seeds, with the objective of determining the quantity of seeds necessary to detect the percentage of mixture mentioned above. The sensitivity of microsatellite technique was evaluated by mixing different proportions of DNA from the hybrids with their respective seed lines. For the level of mixture was higher than 1:8 (1P1:8P2; 8P1:1P2), the sensitivity of the marker in detecting different proportions of the mixture varied according to the primer used. In terms of the sequential sampling, it was verified that in order to detect mixture levels higher than 1% within the seed lot- with a risk level for both the producer and the consumer of 0.05- the size of the necessary sample was smaller than the size needed for the fixed sample size. This also made it possible to reduce costs, making it possible to use microsatellites to certify the genetic purity of corn seeds lots.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)