963 resultados para Saturation Impulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study proton - anti-proton cross sections in the framework of an updated minijet eikonal model. We propose a different scheme for fixing the parameters, in which we make use of the measured minijet cross section. We compare the results obtained with the GRV98, MRST98, CTEQ6-L and KLN gluon distributions. The latter includes gluon saturation effects. We conclude that in the very high energy regime the use of the KLN distribution improves significantly the behavior of the cross sections. However this improvement is due to the shape of the KLN gluon density and has little to do with saturation effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There have been few studies on the mutations that cause heterozygous beta-thalassemia and how they affect the iron profile. One hundred and thirty-eight individuals were analyzed, 90 thalasemic β0 and 48 thalasemic β+, identified by classical and molecular methods. Mutations in the hemochromatosis (HFE) gene, detected using PCR-RFLP, were found in 30.4% of these beta-thalassemic patients; heterozygosity for H63D (20.3%) was the most frequent. Ferritin levels and transferrin saturation were similar in beta-thalassemics with and without mutations in the HFE gene. Ferritin concentrations were significantly higher in men and in individuals over 40 years of age. Transferrin saturation also was significantly higher in men, but only in those without HFE gene mutations. There was no significant difference in the iron profile among the β0 and β+ thalassemics, with and without HFE gene mutations. The frequency of ferritin values above 200 ng/mL in women and 300 ng/mL in men was also similar in β0 and β+ thalassemics (P > 0.72). Our conclusion is that ferritin levels are variable in the beta-thalassemia, trait regardless of the type of beta-globin mutation. Furthermore, HFE gene polymorphisms do not change the iron profile in these individuals. ©FUNPEC-RP www.funpecrp.com.br.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Early trauma care is dependent on subjective assessments and sporadic vital sign assessments. We hypothesized that near-infrared spectroscopy-measured cerebral oxygenation (regional oxygen saturation [rSO 2]) would provide a tool to detect cardiovascular compromise during active hemorrhage. We compared rSO 2 with invasively measured mixed venous oxygen saturation (SvO2), mean arterial pressure (MAP), cardiac output, heart rate, and calculated pulse pressure. Methods: Six propofol-anesthetized instrumented swine were subjected to a fixed-rate hemorrhage until cardiovascular collapse. rSO 2 was monitored with noninvasively measured cerebral oximetry; SvO2 was measured with a fiber optic pulmonary arterial catheter. As an assessment of the time responsiveness of each variable, we recorded minutes from start of the hemorrhage for each variable achieving a 5%, 10%, 15%, and 20% change compared with baseline. Results: Mean time to cardiovascular collapse was 35 minutes ± 11 minutes (54 ± 17% total blood volume). Cerebral rSO 2 began a steady decline at an average MAP of 78 mm Hg ± 17 mm Hg, well above the expected autoregulatory threshold of cerebral blood flow. The 5%, 10%, and 15% decreases in rSO 2 during hemorrhage occurred at a similar times to SvO2, but rSO 2 lagged 6 minutes behind the equivalent percentage decreases in MAP. There was a higher correlation between rSO 2 versus MAP (R =0.72) than SvO2 versus MAP (R =0.55). Conclusions: Near-infrared spectroscopy- measured rSO 2 provided reproducible decreases during hemorrhage that were similar in time course to invasively measured cardiac output and SvO2 but delayed 5 to 9 minutes compared with MAP and pulse pressure. rSO 2 may provide an earlier warning of worsening hemorrhagic shock for prompt interventions in patients with trauma when continuous arterial BP measurements are unavailable. © 2012 Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a class of functional differential equations subject to perturbations, which vary in time, and we study the exponential stability of solutions of these equations using the theory of generalized ordinary differential equations and Lyapunov functionals. We introduce the concept of variational exponential stability for generalized ordinary differential equations and we develop the theory in this direction by establishing conditions for the trivial solutions of generalized ordinary differential equations to be exponentially stable. Then, we apply the results to get corresponding ones for impulsive functional differential equations. We also present an example of a delay differential equation with Perron integrable right-hand side where we apply our result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface free energy of conditioned-dentin is one of the factors that interfere with monomeric infiltration of the interfibrillar spaces. Saturation of the tooth matrix with different substances may modulate this energy and, consequently, the wettability of the dentin. To evaluate the influence of different substances used to saturate conditioned-dentin on surface free energy (SFE) of this substrate. Dentin blocks (4 × 7 × 1 mm, n = 6/ group), obtained from the roots of bovine incisors, were etched using phosphoric acid for 15 seconds, rinsed and gently dried. The surfaces were treated for 60 seconds with: ultra-purified water (H20-control); ethanol (EtOH), acetone (ACT), chlorhexidine (CHX), ethylenediaminetetraacetic acid (EDTA); or sodium hypochlorite (NaOCl). The tooth surfaces were once again dried with absorbent paper and prepared for SFE evaluation using three standards: water, formamide and bromonaphthalene. Analysis of variance (ANOVA) and Dunnet's tests (a = 0.05) were applied to the data. Ethylenediaminetetraacetic acid was the only substance that caused a change to the contact angle for the standards water and formamide, while only EtOH influenced the angles formed between formamide and the dentin surface. None of the substances exerted a significant effect for bromonaphtha-lene. In comparison to the control, only EDTA and NaOCl altered both polar components of the SFE. Total SFE was increased by saturation of the collagen matrix by EDTA and reduced when NaOCl was used. Saturation of the collagen matrix by EDTA and EtOH changed the surface free energy of the dentin. In addition, the use of NaOCl negatively interfered with the properties evaluated. The increase of surface free energy and wettability of the dentin surface would allow higher penetration of the the adhesive system, which would be of importance to the clinical success of resin-dentin union.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a model that adequately describes the operation of the transformer at deep saturation, suitable for power-electronics applications, and a method for determining its parameters. Simulation and experimental results are presented to confirm the validity of the model and the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Dreispektrometeranlage der A1-Kollaboration am MainzerElektronenbeschleuniger MAMI wurde im Rahmen dieser Arbeitverwendet, um die Elektrodisintegration des Deuteronsmit Hilfe der Reaktion d(e,e'p)n zu untersuchen. Im ersten Teil der Untersuchungen wurde die longitudinaleund transversale Strukturfunktion aus denWirkungsquerschnitten extrahiert. Die Zentralwerte derkinematischen Parameter waren dabei wie folgt eingestellt:1) Der Impulsübertrag wurde für alle Messungen auf 450 MeV/c festgelegt.2) Das Proton wurde in Richtung des Impulsübertrags nachgewiesen (parallele Kinematik).3) Vier Einstellungen des Energieübertrags, und damit korrespondierend des fehlenden Impulses, wurden gemessen: Energieübertrag / MeV : 128, 226, 289, 360. Fehlender Impuls / (MeV/c): 50, 200, 275, 350.4) Für jede dieser vier Kinematiken wurden mindestens drei verschiedene Einschußenergien bzw. Elektronenstreuwinkel eingestellt, um die Strukturfunktionen mit Hilfe der Rosenbluth-Separation zu bestimmen. Im zweiten Teil der Untersuchungen wurde derWirkungsquerschnitt für hohe fehlende Impulse bestimmt.Dessen Zentralwerte wurden von 30 MeV/c bis 906 MeV/cvariiert, wobei für die hohen fehlenden Impulse das Protonweit außerhalb der Richtung des Impulsübertragesnachzuweisen war. Der Energieübertrag lag dabei zwischen180 MeV und 600 MeV und der Impulsübertrag zwischen608 MeV/c und 698 MeV/c.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Schroeder's backward integration method is the most used method to extract the decay curve of an acoustic impulse response and to calculate the reverberation time from this curve. In the literature the limits and the possible improvements of this method are widely discussed. In this work a new method is proposed for the evaluation of the energy decay curve. The new method has been implemented in a Matlab toolbox. Its performance has been tested versus the most accredited literature method. The values of EDT and reverberation time extracted from the energy decay curves calculated with both methods have been compared in terms of the values themselves and in terms of their statistical representativeness. The main case study consists of nine Italian historical theatres in which acoustical measurements were performed. The comparison of the two extraction methods has also been applied to a critical case, i.e. the structural impulse responses of some building elements. The comparison underlines that both methods return a comparable value of the T30. Decreasing the range of evaluation, they reveal increasing differences; in particular, the main differences are in the first part of the decay, where the EDT is evaluated. This is a consequence of the fact that the new method returns a “locally" defined energy decay curve, whereas the Schroeder's method accumulates energy from the tail to the beginning of the impulse response. Another characteristic of the new method for the energy decay extraction curve is its independence on the background noise estimation. Finally, a statistical analysis is performed on the T30 and EDT values calculated from the impulse responses measurements in the Italian historical theatres. The aim of this evaluation is to know whether a subset of measurements could be considered representative for a complete characterization of these opera houses.