921 resultados para SENSORINEURAL HEARING LOSS


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conclusion: The extended retrolabyrinthine approach (RLA) is a safe and reliable approach for auditory brainstem placement in children. The surgical landmarks to reach cochlear nucleus are adequately exposed by this approach. Objective: To describe a new approach option for auditory brainstem implants (ABIs) in children, highlighting the anatomical landmarks to appropriately expose the foramen of Luschka. Methods: Three prelingually deafened children consecutively operated for ABIs via the RLA. Results: ABI placement via the RLA was successfully performed in all children without any further complications except multidirectional nystagmus in one child. The RLA we employed differed from that used for vestibular schwannoma only in the removal of the posterior semicircular canal. The lateral and superior semicircular canals and the vestibule remained intact, and there was no need to expose the dura of the internal auditory meatus. The jugular bulb was completely exposed to allow adequate visualization of the ninth cranial nerve and cerebellar flocculus.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Description for using stethoscopes adapted to hearing aids. Aim: To describe the adaptation of HAs to stethoscopes used by 2 students in the health field with bilateral hearing impairment. Case reports: Two subjects with hearing loss had their stethoscopes coupled to HAs because of the individual requirements of their professions (healthcare) to perform auscultation. Conclusion: The improvement was measured in situ, and satisfaction was evaluated using a subjective questionnaire. The use of a stethoscope coupled to an HA allowed students with hearing loss to perform auscultation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To portray the family experience when the discovery of hearing impairment in their child. METHODS: Qualitative research with Symbolic Interactionism and Grounded Theory as theoretical and methodological frameworks. Data collection instrument: semi-structured interview. The study included nine families (32 participants). RESULTS: The theme, "Seeing an idealized future collapse", shows that for the family, discovered the possibility of having a child with hearing loss is a moment that involves many negative feelings. CONCLUSION: Discover the hearing loss has a meaning of the expected loss of the perfect child, frustrated expectations and uncertain future. The family has been inadequately approached and the diagnosis has been made late, which requires immediate changes to the practices of professionals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Devido aos avanços na tecnologia dos implantes cocleares e das estratégias de processamento, indivíduos com surdez grave a profunda puderam ouvir sons e reconhecer fala em diferentes graus. A variabilidade nos resultados audiológicos em portadores de surdez pós-lingual tem sido grande e a indicação para o implante coclear tem se estendido e inclui uma população cada vez maior. OBJETIVO: Avaliar em quais pacientes portadores de surdez pós-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. MATERIAIS E MÉTODOS: consulta a artigos científicos por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Foram selecionadas publicações com força de evidência A ou B até a data da investigação, que comparassem aparelhos de amplificação sonora e implante coclear na população com surdez pós-lingual. Desenho do Estudo: revisão sistemática. RESULTADOS: Entre os 2169 artigos consultados, 11 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Seis estudos são do tipo coorte prospectivo, quatro são estudos transversais e um ensaio clinico. CONCLUSÃO: A avaliação dos benefícios obtidos por portadores de surdez pós-lingual reabilitados com o uso de implante coclear mostra que este dispositivo é efetivo e apresenta melhores resultados quando comparado aos aparelhos de amplificação sonora individual.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUÇÃO: A maioria dos pacientes com perda auditiva, incluindo casos de perdas severas, é beneficiada com o uso de aparelho de amplificação sonora individual. Acredita-se que o implante coclear estabeleça melhores resultados na reabilitação de uma criança com perda auditiva nos casos em que a gravidade da deficiência torna os aparelhos acústicos convencionais incapazes de fornecer informação sonora adequada, já que estes necessitam de reserva coclear suficiente para que ocorra detecção acústica. OBJETIVO: Avaliar se em pacientes portadores de surdez pré-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. SÍNTESE DOS DADOS: Revisão sistemática realizada a partir de consulta a artigos científicos selecionados por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Entre os 2169 artigos consultados, 12 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Entre os desenhos de estudos analisados na revisão, 7 são do tipo coorte prospectivo e 5 são estudos transversais. CONCLUSÃO: O implante coclear demonstrou, através de diversos estudos, ser atualmente, a melhor alternativa para os casos de perdas auditivas bilaterais severas ou profundas, atingindo resultados superiores em percepção e desenvolvimento de fala em crianças pré-linguais quando comparados aos aparelhos de amplificação sonora convencionais.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUÇÃO: O BAHA (Bone Ancored Hearing Aid) é um dispositivo auditivo de condução óssea que propaga o som diretamente à orelha interna, utilizado principalmente em pacientes com perda auditiva condutiva associada a atresia aural, mas atualmente também em perdas mistas e neurossensoriais. OBJETIVO: Revisar as principais indicações do BAHA, analisar os resultados audiométricos e os benefícios proporcionados aos pacientes, e compará-los com outras modalidades de tratamento além de comparar os dados da literatura com nossa casuística de 13 pacientes. MÉTODO: A pesquisa foi realizada em bases de dados abrangendo trabalhos em inglês, espanhol e português, sem limites de intervalos de anos, comparando com os resultados dos nossos 13 pacientes submetidos a esse procedimento, no período de 2000 a 2009. RESULTADOS: A maioria dos trabalhos mostrou vantagens do BAHA em comparação à cirurgia reconstrutiva, tanto pelos resultados audiológicos quanto em relação a complicações e recidiva. Os resultados pós-operatórios nos 13 pacientes operados por nossa equipe foi satisfatório e compatível com os da literatura, com fechamento do gap aéreo-ósseo em 7 pacientes e gap aéreo-ósseo de até 10 dB em 6 pacientes. Não houve complicações pós-operatórias. CONCLUSÃO: O BAHA é uma ótima opção de tratamento para pacientes com surdez condutiva bilateral, fato demonstrado pelos bons resultados audiológicos e por se tratar de um procedimento cirúrgico relativamente simples e com baixa taxa de complicações. Os estudos mais recentes vêm abordando seu uso para surdez condutiva e neurossensorial unilateral.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To identify the prevalence of hearing loss for the population in the urban area. METHODS: A cross-sectional household survey based on the World Health Organization Ear and Hearing Disorders Survey Protocol was conducted in 298 households in the urban area of Monte Negro, Rondonia, Northern Brazil, from 2005 to 2007. Ear examinations, behavioral audiometry and pure tone audiometry were conducted on 577 individuals. RESULTS: The results showed that 3.8% (95%CI 2.17;5.45) of population were classifi ed in the disabling hearing impairment category. The prevalence of moderate hearing impairment was 3.4%; severe impairment was 0.4%; and profound hearing impairment was not found. CONCLUSIONS: The impairing hearing loss prevalence found in this study is within of the international prevalence for this level of hearing loss and smaller than observed in a previous study in the South region of Brazil.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new implantable hearing system, the direct acoustic cochlear stimulator (DACS) is presented. This system is based on the principle of a power-driven stapes prosthesis and intended for the treatment of severe mixed hearing loss due to advanced otosclerosis. It consists of an implantable electromagnetic transducer, which transfers acoustic energy directly to the inner ear, and an audio processor worn externally behind the implanted ear. The device is implanted using a specially developed retromeatal microsurgical approach. After removal of the stapes, a conventional stapes prosthesis is attached to the transducer and placed in the oval window to allow direct acoustical coupling to the perilymph of the inner ear. In order to restore the natural sound transmission of the ossicular chain, a second stapes prosthesis is placed in parallel to the first one into the oval window and attached to the patient's own incus, as in a conventional stapedectomy. Four patients were implanted with an investigational DACS device. The hearing threshold of the implanted ears before implantation ranged from 78 to 101 dB (air conduction, pure tone average, 0.5-4 kHz) with air-bone gaps of 33-44 dB in the same frequency range. Postoperatively, substantial improvements in sound field thresholds, speech intelligibility as well as in the subjective assessment of everyday situations were found in all patients. Two years after the implantations, monosyllabic word recognition scores in quiet at 75 dB improved by 45-100 percent points when using the DACS. Furthermore, hearing thresholds were already improved by the second stapes prosthesis alone by 14-28 dB (pure tone average 0.5-4 kHz, DACS switched off). No device-related serious medical complications occurred and all patients have continued to use their device on a daily basis for over 2 years. Copyright (c) 2008 S. Karger AG, Basel.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The pathogenetic mechanism of hearing loss in patients with vestibular schwannomas (VS) remains unclear. Our aim was to determine the radiological and clinical parameters that might be related to hearing. The radiological images and charts of 99 patients were reviewed. Image processing software was used to analyse the maximal tumor diameter in three planes; its volume; its extension cranially, caudally, anteriorly and posteriorly; the width and length of the intrameatal tumor portion, its shape and consistency; and the tumor-fundus distance. These parameters were correlated with the patient's pre-operative hearing range. The degree of hearing correlated significantly with the tumor size, volume and coronal diameter, the degree of intrameatal tumor growth, and the distance between the lateral tumor end and the fundus (p < 0.05). No correlation was found regarding tumor extension, shape and consistency, the presence of hydrocephalus, or the extent of erosion of the internal auditory canal. Loss of hearing in the VS appears to be multifactorial. Determining the radiological parameters related to the hearing level can help to clarify the pathophysiological mechanisms involved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss. INTERVENTIONS In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed. MAIN OUTCOME MEASURES Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor. RESULTS Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso. CONCLUSION Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.