976 resultados para Reactive power


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Large scale wind farms are subject to tripping, as a consequence of turbine failure, over-sensitive protection, turbines not equipped with low-voltage ride through (LVRT), and reactive power compensation device defects which can lead to voltage rises. This paper considers pertinent issues which render tripping based on a study of LVRT and wind farm protection, with methods to avoid large scale wind generator tripping proposed. The results of LVRT field tests in Jiuquan, China in December 2012 show that the proposed approaches are effective. The paper also presents work which proposes an early warning system to forecast the risk of wind power tripping.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Heat pumps can provide domestic heating at a cost that is competitive with oil heating in particular. If the electricity supply contains a significant amount of renewable generation, a move from fossil fuel heating to heat pumps can reduce greenhouse gas emissions. The inherent thermal storage of heat pump installations can also provide the electricity supplier with valuable flexibility. The increase in heat pump installations in the UK and Europe in the last few years poses a challenge for low-voltage networks, due to the use of induction motors to drive the pump compressors. The induction motor load tends to depress voltage, especially on starting. The paper includes experimental results, dynamic load modelling, comparison of experimental results and simulation results for various levels of heat pump deployment. The simulations are based on a generic test network designed to capture the main characteristics of UK distribution system practice. The simulations employ DIgSlILENT to facilitate dynamic simulations that focus on starting current, voltage variations, active power, reactive power and switching transients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper is concerned with the voltage and reactive power issues surrounding the connection of Distributed Generation (DG) on the low-voltage (LV) distribution network. The presented system-wide voltage control algorithm consists of three stages. Firstly available reactive power reserves are utilized. Then, if required, DG active power output is curtailed. Finally, curtailment of non-critical site demand is considered. The control methodology is tested on a variant of the 13-bus IEEE Node Radial Distribution Test Feeder. The presented control algorithm demonstrated that the distribution system operator (DSO) can maintain voltage levels within a desired statutory range by dispatching reactive power from DG or network devices. The practical application of the control strategy is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A PSS/E 32 model of a real section of the Northern Ireland electrical grid was dynamically controlled with Python 2.5. In this manner data from a proposed wide area monitoring system was simulated. The area is of interest as it is a weakly coupled distribution grid with significant distributed generation. The data was used to create an optimization and protection metric that reflected reactive power flow, voltage profile, thermal overload and voltage excursions. Step changes in the metric were introduced upon the operation of special protection systems and voltage excursions. A wide variety of grid conditions were simulated while tap changer positions and switched capacitor banks were iterated through; with the most desirable state returning the lowest optimization and protection metric. The optimized metric was compared against the metric generated from the standard system state returned by PSS/E. Various grid scenarios were explored involving an intact network and compromised networks (line loss) under summer maximum, summer minimum and winter maximum conditions. In each instance the output from the installed distributed generation is varied between 0 MW and 80 MW (120% of installed capacity). It is shown that in grid models the triggering of special protection systems is delayed by between 1 MW and 6 MW (1.5% to 9% of capacity), with 3.5 MW being the average. The optimization and protection metric gives a quantitative value for system health and demonstrates the potential efficacy of wide area monitoring for protection and control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The elastic behavior of the demand consumption jointly used with other available resources such as distributed generation (DG) can play a crucial role for the success of smart grids. The intensive use of Distributed Energy Resources (DER) and the technical and contractual constraints result in large-scale non linear optimization problems that require computational intelligence methods to be solved. This paper proposes a Particle Swarm Optimization (PSO) based methodology to support the minimization of the operation costs of a virtual power player that manages the resources in a distribution network and the network itself. Resources include the DER available in the considered time period and the energy that can be bought from external energy suppliers. Network constraints are considered. The proposed approach uses Gaussian mutation of the strategic parameters and contextual self-parameterization of the maximum and minimum particle velocities. The case study considers a real 937 bus distribution network, with 20310 consumers and 548 distributed generators. The obtained solutions are compared with a deterministic approach and with PSO without mutation and Evolutionary PSO, both using self-parameterization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de Mestrado para obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo Automação e Eletrónica Industrial

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para a obtenção de grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A eficiência energética tem um papel de importância crescente devido a questões ambientais e ao aumento dos custos energéticos. Recentemente foram tomadas medidas para regular o consumo e o fornecimento de energia reativa em Portugal, que tornaram mais rigorosas as condições de faturação. O custo crescente da energia e a implementação das smart grids apontam para um futuro de maior rigor sobre a utilização da energia reativa. Não será de estranhar que as regras de faturação sejam mais severas daqui a uns anos. O desenvolvimento tecnológico nas áreas da análise da energia e nas formas de controlo da compensação de energia reativa permitem resultados muito mais eficazes que aqueles apresentados pelos vulgares sistemas a contactores que constituem a maioria dos cenários. Apesar de terem um custo inicial superior, os sistemas de compensação do fator de potência com filtragem passiva de harmónicos, desde que projetados corretamente, trazem vantagens evidentes na sua exploração a longo prazo. Com este trabalho pretende-se promover a sensibilização para o uso de sistemas mais eficientes na compensação de energia reativa e para que estes sejam projetados mais à medida das necessidades de cada local. Também se demonstra a extrema importância da adequação destes sistemas à qualidade de energia do local, principalmente em termos de conteúdo harmónico. Desta forma, os sistemas serão mais flexíveis em termos de utilização e possibilitam a sua adaptação às necessidades mesmo que as regras de faturação de energia reativa se tornem mais rigorosas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Large-scale renewable energy (RE) integration into the distribution network (DN) causes uncertainties due to its intermittent nature and is a challenging task today. In general RE sources are mostly connected near the end user level, i.e., in the low voltage distribution network. RE integration introduces bi-directional power flows across distribution transformer (DT) and hence DN experiences with several potential problems that includes voltage fluctuations, reactive power compensation and poor power factor in the DN. This study identifies the potential effects causes due to large-scale integration of RE into the Berserker Street Feeder, Frenchville Substation under Rockhampton DN. From the model analyses, it has clearly evident that voltage of the Berserker Street Feeder fluctuates with the increased integration of RE and causes uncertainties in the feeder as well as the DN.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes an effective VAR planning based on reactive power margin for the enhancement of dynamic voltage stability in distribution networks with distributed wind generation. The analysis is carried over a distribution test system representative of the Kumamoto area in Japan. The detailed mathematical modeling of the system is also presented. Firstly, this paper provides simulation results showing the effects of composite load on voltage dynamics in the distribution network through an accurate time-domain analysis. Then, a cost-effective combination of shunt capacitor bank and distribution static synchronous compensator (D-STATCOM) is selected to ensure fast voltage recovery after a sudden disturbance. The analysis shows that the proposed approach can reduce the size of compensating devices, which in turn, reduces the cost. It also reduces power loss of the system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wind power generation is growing rapidly. However, maintaining the wind turbine connection to grid is a real challenge. Recent grid codes require wind turbines to maintain connected to the grid even during fault conditions which increases concerns about its sensitivity to external faults. So, researchers have given attention to investigating the impact of various external faults, and grid disturbances such as voltage sag and short circuit faults, on the fault ride through (FRT) capability of the doubly fed induction generator (DFIG). However, no attention has been given to the impact of internal faults on the dynamic performance of the machine when the fault occurs within the voltage source converters (VSCs) that interface the DFIG with the grid. This paper investigates the impact of the rotor side converter (RSC) IGBT flashover fault on the common coupling (PCC) reactive power and the FRT is proposed. The DFIG compliance with numerous and recently released FRT grid codes under the studied fault, with and without the STATCOM are examined and compared. Furthermore, the capability of a proposed controller to bring the voltage profile at the point of PCC to the nominal steady-state level; maintain the unity power factor operation; and, maintain the connection of the wind turbine to the grid are examined

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The advancement in solar photovoltaic (PV) technology, the cost and efficiency of PVs have encouraged users worldwide to adopt more and more PVs as it is free from greenhouse gas emissions and unlimited in nature. Integration of roof-top solar PV systems is currently emerging rapidly in Australia as the governments are giving attractive incentives and encouraging households to build a sustainable climate-friendly society for the future. The key major barriers to the integration of roof-top solar PV systems are the uncertainties in the performance of the low voltage distribution network due to the intermittent nature of solar PV sources. In this paper, a model was developed to investigate the potential technical impacts of integrating roof-top solar PV systems into the low voltage distribution network in a subtropical climate. The results show that integration of roof-top solar PV in the customer premises causes uncertainties such as voltage fluctuations, phase unbalance, distribution transformer overloading, reactive power compensation, and harmonic injections that detract the overall power quality of the typical distribution network. © 2014 AIP Publishing LLC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a distributed multi-agent scheme is presented for reactive power management with renewable energy sources (RESs). The multi-agent system (MAS) framework is developed for distribution systems to improve the stability which is mostly dominated by voltage and the agents in this framework coordinate among themselves using online information and energy flow. In this paper, the agents basically perform two tasks- reactive power estimation and necessary control actions. The topology of distribution network is used to estimate the required reactive power for maintaining voltage stability where distributed static synchronous compensators (DSTATCOMs) are used to supply this reactive power. The DSTATCOM is controlled by using a linear quadratic regulator (LQR) controller within the agent framework. The proposed scheme is further compared with the conventional approach to validate the simulation results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a nonlinear controller design for vehicle-to-grid (V2G) systems with LCL output filters. The V2G systems are modeled with LCL output filters in order to eliminate harmonics for improving power qualities and the nonlinear controller is designed based on the feedback linearization. The feasibility of using the appropriate feedback linearization approaches, either partial or exact, is also investigated through the feedback linearizability of V2G systems. In this paper, partial feedback linearization is used to design the controller with a capability of sharing both active and reactive power in V2G systems. The performance of the proposed controller controller is evaluated on a single-phase full-bridge converter-based V2G system with an LCL output filter and compared to that of without any filter. Simulation results clearly demonstrate the harmonic elimination capabilities of the proposed V2G structure with the proposed control scheme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)